Kunhua Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kunhua Wu has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
Qiu Bi
Department of MRI, the First People’s Hospital of Yunnan Province, Kunming, China
8 shared publicationsYuchen Deng
Department of MRI, the Affiliated Hospital of Kunming University of Science and Technology, Kunming, China
4 shared publicationsJie Zhang
Department of MRI, The First People's Hospital of Yunnan Province, The Affiliated Hospital of Kunming University of Science and Technology, Kunming, China
3 shared publicationsJunna Wang
Center of Infectious Diseases, West China Hospital of Sichuan University, No. 37 Guoxue Lane, Wuhou District, Chengdu 610041, Sichuan, China
3 shared publicationsYunzhu Wu
Institute for AI in Medicine, School of Artificial Intelligence, Nanjing University of Information Science and Technology, Nanjing, China
3 shared publicationsGuoli Bi
Department of MRI, the First People' s Hospital of Yunnan Province, the Affiliated Hospital of Kunming University of Science and Technology, No. 157 Jinbi Road, Kunming 650032, Yunnan, China
2 shared publications
Latest Publications
- Open Access
- 5 November 2025
- Published by Springer Nature in Cancer Imaging
- Vol. 25 (1) , 1-10
The performance of DWI and ADC values with different b-values for the diagnosis and staging of endometrial carcinoma at 3T
To evaluate the efficiency of diffusion weighted imaging (DWI), the mean apparent diffusion coefficient (ADCmean) and the minimum apparent diffusion coefficient (ADCmin) values with different b-values (800 s/mm² and 1000 s/mm²) in the diagnosis and staging of endometrial carcinoma (EC). Preoperative DWI images of 412 patients with EC and 134 patients with benign endometrial lesions were analyzed retrospectively. The performance of DWI images, ADCmean and ADCmin values with different b-values (800 s/mm² and 1000 s/mm²) for the diagnosis and staging (deep myometrial invasion, cervical stromal invasion and lymph node metastasis) of EC was assessed by using receiver operating characteristic curve (ROC). The comparison between AUCs was performed using the DeLong test, and a P value < 0.05 was considered statistically significant. The area under the curves (AUCs) of DWI protocol with b = 1000 s/mm2 for qualitative assessment of EC diagnosis and staging (0.850, 0.837, 0.906, and 0.820 for diagnosis, deep myometrial invasion, cervical stromal invasion and lymph node metastasis, respectively) were higher than those of b = 800 s/mm2 (0.821, 0.795, 0.860 and 0.814, respectively) (all p < 0.05). The AUCs for the quantitative assessment of EC diagnosis and staging with ADCmean and ADCmin values with b = 1000 s/mm2 were higher than those of b = 800 s/mm2 (all p < 0.05). DWI images, ADCmean and ADCmin values with b = 1000 s/mm2 had higher performance than those of b = 800 s/mm2 in the assessment of EC diagnosis and staging. This study highlights the potential of using b = 1000 s/mm² as an optimized protocol for EC assessment in clinical practice.
- 5 November 2025
- Published by Springer Nature in Cancer Imaging
- Vol. 25 (1) , 1-10
Open AccessThe performance of DWI and ADC values with different b-values for the diagnosis and staging of endometrial carcinoma at 3T
To evaluate the efficiency of diffusion weighted imaging (DWI), the mean apparent diffusion coefficient (ADCmean) and the minimum apparent diffusion coefficient (ADCmin) values with different b-values (800 s/mm² and 1000 s/mm²) in the diagnosis and staging of endometrial carcinoma (EC). Preoperative DWI images of 412 patients with EC and 134 patients with benign endometrial lesions were analyzed retrospectively. The performance of DWI images, ADCmean and ADCmin values with different b-values (800 s/mm² and 1000 s/mm²) for the diagnosis and staging (deep myometrial invasion, cervical stromal invasion and lymph node metastasis) of EC was assessed by using receiver operating characteristic curve (ROC). The comparison between AUCs was performed using the DeLong test, and a P value < 0.05 was considered statistically significant. The area under the curves (AUCs) of DWI protocol with b = 1000 s/mm2 for qualitative assessment of EC diagnosis and staging (0.850, 0.837, 0.906, and 0.820 for diagnosis, deep myometrial invasion, cervical stromal invasion and lymph node metastasis, respectively) were higher than those of b = 800 s/mm2 (0.821, 0.795, 0.860 and 0.814, respectively) (all p < 0.05). The AUCs for the quantitative assessment of EC diagnosis and staging with ADCmean and ADCmin values with b = 1000 s/mm2 were higher than those of b = 800 s/mm2 (all p < 0.05). DWI images, ADCmean and ADCmin values with b = 1000 s/mm2 had higher performance than those of b = 800 s/mm2 in the assessment of EC diagnosis and staging. This study highlights the potential of using b = 1000 s/mm² as an optimized protocol for EC assessment in clinical practice.
- Open Access
- 1 January 2025
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 15 (1) , 121-134
Differentiation of early-stage endometrial carcinoma from benign endometrial lesions: a comparative study of six diffusion models
Background: Accurate differentiation between benign and malignant endometrial lesions holds substantial clinical importance. This study aimed to evaluate the efficacy of various diffusion models in the preoperative diagnosis of early-stage endometrial carcinoma (EC). Methods: A total of 72 consecutive patients with benign or malignant endometrial lesions from the First People’s Hospital of Yunnan Province were prospectively enrolled between April 2021 and July 2023. Fourteen diffusion parameters derived from monoexponential diffusion-weighted imaging (DWI), diffusion kurtosis imaging (DKI), intravoxel incoherent motion (IVIM), stretched exponential model (SEM), continuous-time random walk (CTRW), and fractional order calculus (FROC) models were calculated and compared. Independent predictors of early-stage EC were identified using logistic regression analysis. The performance of the diffusion parameters, both individually and in combination with effective clinical indicators, for differentiating benign and malignant endometrial lesions was evaluated. Results: This study consisted of 17 patients with benign endometrial lesions and 55 patients with EC. Significant differences in age and menopausal status were observed between the benign and malignant endometrial groups (P=0.015 and P=0.011, respectively). With the exception of the pseudodiffusion coefficient (D*) and perfusion fraction (f), all other parameters exhibited significant differences between the benign and malignant groups (PCTRW) were identified as independent predictors of early-stage EC, achieving an area under the curve (AUC) of 0.903 [95% confidence interval (CI): 0.824–0.982], surpassing that of any individual diffusion parameter. The combination of these independent predictors with menopausal status yielded the highest AUC (0.922, 95% CI: 0.845–0.999), accuracy (93.1%), and sensitivity (100.0%). Conclusions: MK, D, and αCTRW have the potential to serve as independent predictors in predicting early-stage EC, and the performance can be enhanced when combined with menopausal status.
- 1 January 2025
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 15 (1) , 121-134
Open AccessDifferentiation of early-stage endometrial carcinoma from benign endometrial lesions: a comparative study of six diffusion models
Background: Accurate differentiation between benign and malignant endometrial lesions holds substantial clinical importance. This study aimed to evaluate the efficacy of various diffusion models in the preoperative diagnosis of early-stage endometrial carcinoma (EC). Methods: A total of 72 consecutive patients with benign or malignant endometrial lesions from the First People’s Hospital of Yunnan Province were prospectively enrolled between April 2021 and July 2023. Fourteen diffusion parameters derived from monoexponential diffusion-weighted imaging (DWI), diffusion kurtosis imaging (DKI), intravoxel incoherent motion (IVIM), stretched exponential model (SEM), continuous-time random walk (CTRW), and fractional order calculus (FROC) models were calculated and compared. Independent predictors of early-stage EC were identified using logistic regression analysis. The performance of the diffusion parameters, both individually and in combination with effective clinical indicators, for differentiating benign and malignant endometrial lesions was evaluated. Results: This study consisted of 17 patients with benign endometrial lesions and 55 patients with EC. Significant differences in age and menopausal status were observed between the benign and malignant endometrial groups (P=0.015 and P=0.011, respectively). With the exception of the pseudodiffusion coefficient (D*) and perfusion fraction (f), all other parameters exhibited significant differences between the benign and malignant groups (PCTRW) were identified as independent predictors of early-stage EC, achieving an area under the curve (AUC) of 0.903 [95% confidence interval (CI): 0.824–0.982], surpassing that of any individual diffusion parameter. The combination of these independent predictors with menopausal status yielded the highest AUC (0.922, 95% CI: 0.845–0.999), accuracy (93.1%), and sensitivity (100.0%). Conclusions: MK, D, and αCTRW have the potential to serve as independent predictors in predicting early-stage EC, and the performance can be enhanced when combined with menopausal status.
- Open Access
- 13 June 2024
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 14, 1392343
Different MRI-based radiomics models for differentiating misdiagnosed or ambiguous pleomorphic adenoma and Warthin tumor of the parotid gland: a multicenter study
Purpose: To evaluate the effectiveness of MRI-based radiomics models in distinguishing between Warthin tumors (WT) and misdiagnosed or ambiguous pleomorphic adenoma (PA).Methods: Data of patients with PA and WT from two centers were collected. MR images were used to extract radiomic features. The optimal radiomics model was found by running nine machine learning algorithms after feature reduction and selection. To create a clinical model, univariate logistic regression (LR) analysis and multivariate LR were used. The independent clinical predictors and radiomics were combined to create a nomogram. Two integrated models were constructed by the ensemble and stacking algorithms respectively based on the clinical model and the optimal radiomics model. The models’ performance was evaluated using the area under the curve (AUC).Results: There were 149 patients included in all. Gender, age, and smoking of patients were independent clinical predictors. With the greatest average AUC (0.896) and accuracy (0.839) in validation groups, the LR model was the optimal radiomics model. In the average validation group, the radiomics model based on LR did not have a higher AUC (0.795) than the clinical model (AUC = 0.909). The nomogram (AUC = 0.953) outperformed the radiomics model in terms of discrimination performance. The nomogram in the average validation group had a highest AUC than the stacking model (0.914) or ensemble model (0.798).Conclusion: Misdiagnosed or ambiguous PA and WT can be non-invasively distinguished using MRI-based radiomics models. The nomogram exhibited excellent and stable diagnostic performance. In daily work, it is necessary to combine with clinical parameters for distinguishing between PA and WT.
- 13 June 2024
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 14, 1392343
Open AccessDifferent MRI-based radiomics models for differentiating misdiagnosed or ambiguous pleomorphic adenoma and Warthin tumor of the parotid gland: a multicenter study
Purpose: To evaluate the effectiveness of MRI-based radiomics models in distinguishing between Warthin tumors (WT) and misdiagnosed or ambiguous pleomorphic adenoma (PA).Methods: Data of patients with PA and WT from two centers were collected. MR images were used to extract radiomic features. The optimal radiomics model was found by running nine machine learning algorithms after feature reduction and selection. To create a clinical model, univariate logistic regression (LR) analysis and multivariate LR were used. The independent clinical predictors and radiomics were combined to create a nomogram. Two integrated models were constructed by the ensemble and stacking algorithms respectively based on the clinical model and the optimal radiomics model. The models’ performance was evaluated using the area under the curve (AUC).Results: There were 149 patients included in all. Gender, age, and smoking of patients were independent clinical predictors. With the greatest average AUC (0.896) and accuracy (0.839) in validation groups, the LR model was the optimal radiomics model. In the average validation group, the radiomics model based on LR did not have a higher AUC (0.795) than the clinical model (AUC = 0.909). The nomogram (AUC = 0.953) outperformed the radiomics model in terms of discrimination performance. The nomogram in the average validation group had a highest AUC than the stacking model (0.914) or ensemble model (0.798).Conclusion: Misdiagnosed or ambiguous PA and WT can be non-invasively distinguished using MRI-based radiomics models. The nomogram exhibited excellent and stable diagnostic performance. In daily work, it is necessary to combine with clinical parameters for distinguishing between PA and WT.
- Open Access
- 5 August 2022
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 12, 939930
Different multiparametric MRI-based radiomics models for differentiating stage IA endometrial cancer from benign endometrial lesions: A multicenter study
Purpose: The aim of this study was to evaluate the value of different multiparametric MRI-based radiomics models in differentiating stage IA endometrial cancer (EC) from benign endometrial lesions.Methods: The data of patients with endometrial lesions from two centers were collected. The radiomics features were extracted from T2-weighted imaging (T2WI), diffusion-weighted imaging (DWI), apparent diffusion coefficient (ADC) map, and late contrast-enhanced T1-weighted imaging (LCE-T1WI). After data dimension reduction and feature selection, nine machine learning algorithms were conducted to determine which was the optimal radiomics model for differential diagnosis. The univariate analyses and logistic regression (LR) were performed to reduce valueless clinical parameters and to develop the clinical model. A nomogram using the radscores combined with clinical parameters was developed. Two integrated models were obtained respectively by the ensemble strategy and stacking algorithm based on the clinical model and optimal radiomics model. The area under the curve (AUC), clinical decisive curve (CDC), net reclassification index (NRI), and integrated discrimination index (IDI) were used to evaluate the performance and clinical benefits of the models.Results: A total of 371 patients were incorporated. The LR model was the optimal radiomics model with the highest average AUC (0.854) and accuracy (0.802) in the internal and external validation groups (AUC = 0.910 and 0.798, respectively), and outperformed the clinical model (AUC = 0.739 and 0.592, respectively) or the radiologist (AUC = 0.768 and 0.628, respectively). The nomogram (AUC = 0.917 and 0.802, respectively) achieved better discrimination performance than the optimal radiomics model in two validation groups. The stacking model (AUC = 0.915) and ensemble model (AUC = 0.918) had a similar performance compared with the nomogram in the internal validation group, whereas the AUCs of the stacking model (AUC = 0.792) and ensemble model (AUC = 0.794) were lower than those of the nomogram and radiomics model in the external validation group. According to the CDC, NRI, and IDI, the optimal radiomics model, nomogram, stacking model, and ensemble model achieved good net benefits.Conclusions: Multiparametric MRI-based radiomics models can non-invasively differentiate stage IA EC from benign endometrial lesions, and LR is the best machine learning algorithm. The nomogram presents excellent and stable diagnostic efficiency.
- 5 August 2022
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 12, 939930
Open AccessDifferent multiparametric MRI-based radiomics models for differentiating stage IA endometrial cancer from benign endometrial lesions: A multicenter study
Purpose: The aim of this study was to evaluate the value of different multiparametric MRI-based radiomics models in differentiating stage IA endometrial cancer (EC) from benign endometrial lesions.Methods: The data of patients with endometrial lesions from two centers were collected. The radiomics features were extracted from T2-weighted imaging (T2WI), diffusion-weighted imaging (DWI), apparent diffusion coefficient (ADC) map, and late contrast-enhanced T1-weighted imaging (LCE-T1WI). After data dimension reduction and feature selection, nine machine learning algorithms were conducted to determine which was the optimal radiomics model for differential diagnosis. The univariate analyses and logistic regression (LR) were performed to reduce valueless clinical parameters and to develop the clinical model. A nomogram using the radscores combined with clinical parameters was developed. Two integrated models were obtained respectively by the ensemble strategy and stacking algorithm based on the clinical model and optimal radiomics model. The area under the curve (AUC), clinical decisive curve (CDC), net reclassification index (NRI), and integrated discrimination index (IDI) were used to evaluate the performance and clinical benefits of the models.Results: A total of 371 patients were incorporated. The LR model was the optimal radiomics model with the highest average AUC (0.854) and accuracy (0.802) in the internal and external validation groups (AUC = 0.910 and 0.798, respectively), and outperformed the clinical model (AUC = 0.739 and 0.592, respectively) or the radiologist (AUC = 0.768 and 0.628, respectively). The nomogram (AUC = 0.917 and 0.802, respectively) achieved better discrimination performance than the optimal radiomics model in two validation groups. The stacking model (AUC = 0.915) and ensemble model (AUC = 0.918) had a similar performance compared with the nomogram in the internal validation group, whereas the AUCs of the stacking model (AUC = 0.792) and ensemble model (AUC = 0.794) were lower than those of the nomogram and radiomics model in the external validation group. According to the CDC, NRI, and IDI, the optimal radiomics model, nomogram, stacking model, and ensemble model achieved good net benefits.Conclusions: Multiparametric MRI-based radiomics models can non-invasively differentiate stage IA EC from benign endometrial lesions, and LR is the best machine learning algorithm. The nomogram presents excellent and stable diagnostic efficiency.
- 28 June 2022
- Published by Elsevier in Academic Radiology
- Vol. 30 (4) , 668-679
Development and Validation of an MRI-based Radiomics Nomogram for Assessing Deep Myometrial Invasion in Early Stage Endometrial Adenocarcinoma
- 28 June 2022
- Published by Elsevier in Academic Radiology
- Vol. 30 (4) , 668-679
Development and Validation of an MRI-based Radiomics Nomogram for Assessing Deep Myometrial Invasion in Early Stage Endometrial Adenocarcinoma
- Open Access
- 1 January 2021
- Published by Ivyspring International Publisher in Journal of Cancer
- Vol. 12 (3) , 754-764
Diagnostic Accuracy of MRI for Detecting Cervical Invasion in Patients with Endometrial Carcinoma: A Meta-Analysis
Objectives: To evaluate the diagnostic accuracy of magnetic resonance imaging (MRI) in the preoperative assessment of cervical invasion and to analyse the influence of different imaging protocols in patients with endometrial carcinoma.
- 1 January 2021
- Published by Ivyspring International Publisher in Journal of Cancer
- Vol. 12 (3) , 754-764
Open AccessDiagnostic Accuracy of MRI for Detecting Cervical Invasion in Patients with Endometrial Carcinoma: A Meta-Analysis
Objectives: To evaluate the diagnostic accuracy of magnetic resonance imaging (MRI) in the preoperative assessment of cervical invasion and to analyse the influence of different imaging protocols in patients with endometrial carcinoma.
- 1 July 2020
- Published by Elsevier in Academic Radiology
- Vol. 27 (7) , 960-968
The Diagnostic Value of MRI for Preoperative Staging in Patients with Endometrial Cancer: A Meta-Analysis
- 1 July 2020
- Published by Elsevier in Academic Radiology
- Vol. 27 (7) , 960-968
The Diagnostic Value of MRI for Preoperative Staging in Patients with Endometrial Cancer: A Meta-Analysis
- Open Access
- 16 April 2020
- Published by Springer Nature in Research Square
Diagnostic accuracy of MRI for detecting cervical invasion in patients with endometrial carcinoma: A meta-analysis
Background: Clinical management and the prognosis of endometrial cancer is closely related to cervical invasion. The diagnostic performance of MRI for detecting cervical invasion has not been comprehensively assessed. We aim to evaluate the diagnostic accuracy of magnetic resonance imaging (MRI) in the preoperative assessment of cervical invasion and to analyze the influence of different imaging protocols in patients with endometrial carcinoma.Methods: An extensive search of articles about MRI in assessing cervical invasion in patients with endometrial carcinoma was performed in PubMed, Embase, Web of Science, Cochrane Library, and Clinical Trials from January 2000 to July 2019. Two reviewers independently evaluated the methodological quality of each study by using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2). Diagnostic accuracy results and additional useful information were extracted. Pooled estimation data was obtained by statistical analysis. Results: A total of 42 eligible studies were included in the meta-analysis. Significant evidence of heterogeneity was found for detecting cervical invasion (I2 = 74.1%, P = 0.00 for sensitivity and I2 = 56.2%, P = 0.00 for specificity). And the pooled sensitivity and specificity of MRI were 0.58 and 0.95 respectively. The use of higher field strength (3.0 T) demonstrated higher pooled sensitivity (0.74). Using diffusion-weighted imaging (DWI) alone presented higher pooled sensitivity (0.86) than using other sequences. Studies that used dynamic contrast-enhanced MRI (DCE-MRI) alone showed higher sensitivity (0.80) and specificity (0.96) than that used T2-weighted image (T2WI) alone.Conclusions: MRI shows high specificity for detecting cervical infiltration in endometrial carcinoma. Using DWI or a 3.0-T device may improve the pooled sensitivity. The use of DCE-MRI demonstrate higher pooled sensitivity and specificity than T2WI.
- 16 April 2020
- Published by Springer Nature in Research Square
Open AccessDiagnostic accuracy of MRI for detecting cervical invasion in patients with endometrial carcinoma: A meta-analysis
Background: Clinical management and the prognosis of endometrial cancer is closely related to cervical invasion. The diagnostic performance of MRI for detecting cervical invasion has not been comprehensively assessed. We aim to evaluate the diagnostic accuracy of magnetic resonance imaging (MRI) in the preoperative assessment of cervical invasion and to analyze the influence of different imaging protocols in patients with endometrial carcinoma.Methods: An extensive search of articles about MRI in assessing cervical invasion in patients with endometrial carcinoma was performed in PubMed, Embase, Web of Science, Cochrane Library, and Clinical Trials from January 2000 to July 2019. Two reviewers independently evaluated the methodological quality of each study by using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2). Diagnostic accuracy results and additional useful information were extracted. Pooled estimation data was obtained by statistical analysis. Results: A total of 42 eligible studies were included in the meta-analysis. Significant evidence of heterogeneity was found for detecting cervical invasion (I2 = 74.1%, P = 0.00 for sensitivity and I2 = 56.2%, P = 0.00 for specificity). And the pooled sensitivity and specificity of MRI were 0.58 and 0.95 respectively. The use of higher field strength (3.0 T) demonstrated higher pooled sensitivity (0.74). Using diffusion-weighted imaging (DWI) alone presented higher pooled sensitivity (0.86) than using other sequences. Studies that used dynamic contrast-enhanced MRI (DCE-MRI) alone showed higher sensitivity (0.80) and specificity (0.96) than that used T2-weighted image (T2WI) alone.Conclusions: MRI shows high specificity for detecting cervical infiltration in endometrial carcinoma. Using DWI or a 3.0-T device may improve the pooled sensitivity. The use of DCE-MRI demonstrate higher pooled sensitivity and specificity than T2WI.