Douglas George Tasker
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Douglas George Tasker has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
Henn Oona
Los Alamos National Laboratory, Los Alamos, NM, USA
4 shared publicationsDennis H. Herrera
Los Alamos National Laboratory, Los Alamos, New Mexico, 87545, USA
3 shared publicationsChristopher J. Trujillo
Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
2 shared publicationsClarence M. Fowler
Los Alamos National Laboratory, Los Alamos, New Mexico, 87545, USA
2 shared publicationsDalton Smith
Detonator Technology Group, MS C925, Los Alamos National Laboratory, Los Alamos, NM, USA 87545
2 shared publicationsEdward L. Ruden
Directed Energy Directorate, Air Force Research Laboratory, Kirtland AFB, NM 87117 USA
2 shared publications
Latest Publications
- Open Access
- 1 July 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (7)
An updated technique to obtain explosive kinetics data on microsecond timescales
There are few techniques available for chemists to obtain time-to-explosion data with known temperature inputs at the early stages of the design and synthesis of new explosives. In the 1960s, a technique was developed to rapidly heat milligram-quantities of confined explosives to ∼1000 K on microsecond timescales. Wenograd [Trans. Faraday Soc. 57, 1612 (1961)] loaded explosives inside stainless steel hypodermic needles, connected them to a fireset and rapidly discharged a capacitor through the steel. He obtained the temperature by measuring the needle resistance in a Wheatstone bridge arrangement and the time to explosion from a needle rupture. However, owing to the narrow-gauge needles used in the original research, the experiment was only possible with melt-castable explosives; it was never replicated, and modern diagnostics are now available with advances beyond the 1960s. Here, we report the development of the High Explosives Initiation Time (HEIT) test, which utilizes a 250 J pulsed power system to heat the needles. This work extends the Wenograd approach by using optical diagnostics, computational modeling, and advanced techniques to measure needle resistance and needle rupture. Preliminary rate information for pentaerythritol tetranitrate (PETN) will be presented.
- 1 July 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (7)
Open AccessAn updated technique to obtain explosive kinetics data on microsecond timescales
There are few techniques available for chemists to obtain time-to-explosion data with known temperature inputs at the early stages of the design and synthesis of new explosives. In the 1960s, a technique was developed to rapidly heat milligram-quantities of confined explosives to ∼1000 K on microsecond timescales. Wenograd [Trans. Faraday Soc. 57, 1612 (1961)] loaded explosives inside stainless steel hypodermic needles, connected them to a fireset and rapidly discharged a capacitor through the steel. He obtained the temperature by measuring the needle resistance in a Wheatstone bridge arrangement and the time to explosion from a needle rupture. However, owing to the narrow-gauge needles used in the original research, the experiment was only possible with melt-castable explosives; it was never replicated, and modern diagnostics are now available with advances beyond the 1960s. Here, we report the development of the High Explosives Initiation Time (HEIT) test, which utilizes a 250 J pulsed power system to heat the needles. This work extends the Wenograd approach by using optical diagnostics, computational modeling, and advanced techniques to measure needle resistance and needle rupture. Preliminary rate information for pentaerythritol tetranitrate (PETN) will be presented.
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2844 (1)
Improving manganin gauge measurements near radiographic fiducials
In dynamic experiments diagnosed with radiography and stress gauges, the gauges are often placed adjacent to radio-graphic fiducials, such as Ta foil, which perturbs the stress measurement. We conducted experiments to test the performance of different arrangements of manganin stress gauges and Ta foils. Three different gauge/foil configurations were tested, as well as a solitary gauge as control. Gauge/foil layers were placed between high-density polyethylene (HDPE) discs and impacted by a projectile in a gas gun, a simplification of a dynamic, high explosive experiment configuration. The stress measurements were minimally perturbed when a section of foil was removed near the active element of the gauge, as expected. A follow-up experiment showed that the modification to the foil has minimal impact on the radiographic measurement of the dynamic flow.
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2844 (1)
Improving manganin gauge measurements near radiographic fiducials
In dynamic experiments diagnosed with radiography and stress gauges, the gauges are often placed adjacent to radio-graphic fiducials, such as Ta foil, which perturbs the stress measurement. We conducted experiments to test the performance of different arrangements of manganin stress gauges and Ta foils. Three different gauge/foil configurations were tested, as well as a solitary gauge as control. Gauge/foil layers were placed between high-density polyethylene (HDPE) discs and impacted by a projectile in a gas gun, a simplification of a dynamic, high explosive experiment configuration. The stress measurements were minimally perturbed when a section of foil was removed near the active element of the gauge, as expected. A follow-up experiment showed that the modification to the foil has minimal impact on the radiographic measurement of the dynamic flow.
- 1 April 2022
- Published by Office of Scientific and Technical Information (OSTI)
Manganin gauges: Methods, calibrations and use in explosive experiments [Slides]
The U.S. Department of Energy's Office of Scientific and Technical Information
- 1 April 2022
- Published by Office of Scientific and Technical Information (OSTI)
Manganin gauges: Methods, calibrations and use in explosive experiments [Slides]
The U.S. Department of Energy's Office of Scientific and Technical Information
- 8 April 2020
- Published by Office of Scientific and Technical Information (OSTI)
LANL studies of ESD spark energy discharge through September 2019
The U.S. Department of Energy's Office of Scientific and Technical Information
- 8 April 2020
- Published by Office of Scientific and Technical Information (OSTI)
LANL studies of ESD spark energy discharge through September 2019
The U.S. Department of Energy's Office of Scientific and Technical Information
- Open Access
- 14 April 2019
- Published by ASME International
Voitenko experiments with novel diagnostics detect velocities of 89 km/s
Using a Voitenko accelerator [1-3], a series of experiments were performed with the goal of attaining shock velocities in gases approaching 90 km/s. Typically, the basic apparatus comprises a hemispherical bowl filled with a gas at atmospheric pressure; a metal piston across its diameter; and a small bore evacuated shock tube at its apex, Fig. 1. The evacuated shock tube is separated from the gas bowl by a thin diaphragm. A combination of a plane wave explosive lens and a high explosive pad accelerates the piston to a velocity of the order of 4 km/s and subsequently compresses the gas in the bowl. The thin diaphragm at the other end of the bowl then ruptures and the high pressure (shock compressed) gas escapes into the shock tube.
- 14 April 2019
- Published by ASME International
Open AccessVoitenko experiments with novel diagnostics detect velocities of 89 km/s
Using a Voitenko accelerator [1-3], a series of experiments were performed with the goal of attaining shock velocities in gases approaching 90 km/s. Typically, the basic apparatus comprises a hemispherical bowl filled with a gas at atmospheric pressure; a metal piston across its diameter; and a small bore evacuated shock tube at its apex, Fig. 1. The evacuated shock tube is separated from the gas bowl by a thin diaphragm. A combination of a plane wave explosive lens and a high explosive pad accelerates the piston to a velocity of the order of 4 km/s and subsequently compresses the gas in the bowl. The thin diaphragm at the other end of the bowl then ruptures and the high pressure (shock compressed) gas escapes into the shock tube.
- 3 July 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1979 (1) , 150016
Novel uses of detonator diagnostics
A novel combination of diagnostics is being used to research the physics of detonator initiation. The explosive PETN (Pentaerythritol tetranitrate) commonly used in detonators, is also a piezo-electric material that, when sufficiently shocked, emits an electromagnetic field in the radio frequency (RF) range, along crystal fracture planes. In an effort to capture this RF signal, a new diagnostic was created. A copper foil, used as an RF antenna, was wrapped around a foam fixture encompassing a PETN pellet. Rogowski coils were used to obtain the change in current with respect to time (di/dt) the detonator circuit, in and polyvinylidene difluoride (PVDF) stress sensors were used to capture shockwave arrival time. The goal of these experiments is to use these diagnostics to study the reaction response of a PETN pellet of known particle size to shock loading with various diagnostics including an antenna to capture RF emissions. Our hypothesis is that RF feedback may signify the rate of deflagration to detonation transition (DDT) or lack thereof. The new diagnostics and methods will be used to determine the timing of start of current, bridge burst, detonator breakout timing and RF generated from detonation. These data will be compared to those of currently used diagnostics in order to validate the accuracy of these new methods. Future experiments will incorporate other methods of validation including dynamic radiography, optical initiation and use of magnetic field sensors.
- 3 July 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1979 (1) , 150016
Novel uses of detonator diagnostics
A novel combination of diagnostics is being used to research the physics of detonator initiation. The explosive PETN (Pentaerythritol tetranitrate) commonly used in detonators, is also a piezo-electric material that, when sufficiently shocked, emits an electromagnetic field in the radio frequency (RF) range, along crystal fracture planes. In an effort to capture this RF signal, a new diagnostic was created. A copper foil, used as an RF antenna, was wrapped around a foam fixture encompassing a PETN pellet. Rogowski coils were used to obtain the change in current with respect to time (di/dt) the detonator circuit, in and polyvinylidene difluoride (PVDF) stress sensors were used to capture shockwave arrival time. The goal of these experiments is to use these diagnostics to study the reaction response of a PETN pellet of known particle size to shock loading with various diagnostics including an antenna to capture RF emissions. Our hypothesis is that RF feedback may signify the rate of deflagration to detonation transition (DDT) or lack thereof. The new diagnostics and methods will be used to determine the timing of start of current, bridge burst, detonator breakout timing and RF generated from detonation. These data will be compared to those of currently used diagnostics in order to validate the accuracy of these new methods. Future experiments will incorporate other methods of validation including dynamic radiography, optical initiation and use of magnetic field sensors.
- 3 July 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1979 (1) , 160028
Rogowski coils for studies of detonator initiation and other diagnostics
Detonators are fundamental to most explosive systems, yet the detonators themselves are rarely diagnosed to determine how well they function or why they fail. To remedy this, various electrical diagnostics were explored, including: Rogowski coils for high fidelity detection of changes in electrical current in explosive bridgewires and how they relate to detonator performance; and radio frequency (RF) antennas to detect any electromagnetic emissions associated with reaction and growth in the explosives. A new type of Rogowski coil is described and some interesting phenomena were detected with the radio frequency antenna.
- 3 July 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1979 (1) , 160028
Rogowski coils for studies of detonator initiation and other diagnostics
Detonators are fundamental to most explosive systems, yet the detonators themselves are rarely diagnosed to determine how well they function or why they fail. To remedy this, various electrical diagnostics were explored, including: Rogowski coils for high fidelity detection of changes in electrical current in explosive bridgewires and how they relate to detonator performance; and radio frequency (RF) antennas to detect any electromagnetic emissions associated with reaction and growth in the explosives. A new type of Rogowski coil is described and some interesting phenomena were detected with the radio frequency antenna.
- 3 July 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1979 (1) , 160009
Initiation of insensitive high explosives using multiple wave interactions
Insensitive High Explosives (IHEs) increase safety in many types of uses. However, the safety comes at the cost of performance. Initiation of IHE requires large boosters and powerful detonators as well. Multipoint initiation is being utilized to exploit explosive wave interactions to create overdriven states, greatly facilitating the initiation of IHEs. This concept builds from recent explosive experiments where the minimum spot size for single-point initiation in PBX 9502 was determined. Below this threshold, PBX 9502 could not be initiated. This was then expanded to three initiation points, which were smaller than this threshold. Measurements of the velocity and pressure of the wave interactions were collected using Photon Doppler Velocimetry (PDV). Not only was initiation observed, but the resulting pressures at the double and triple points were found to be above the CJ state for PBX 9502. Based on these results, further tests were conducted to isolate and measure the longevity and pressure of this phenomenon using a series of cutback tests.
- 3 July 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1979 (1) , 160009
Initiation of insensitive high explosives using multiple wave interactions
Insensitive High Explosives (IHEs) increase safety in many types of uses. However, the safety comes at the cost of performance. Initiation of IHE requires large boosters and powerful detonators as well. Multipoint initiation is being utilized to exploit explosive wave interactions to create overdriven states, greatly facilitating the initiation of IHEs. This concept builds from recent explosive experiments where the minimum spot size for single-point initiation in PBX 9502 was determined. Below this threshold, PBX 9502 could not be initiated. This was then expanded to three initiation points, which were smaller than this threshold. Measurements of the velocity and pressure of the wave interactions were collected using Photon Doppler Velocimetry (PDV). Not only was initiation observed, but the resulting pressures at the double and triple points were found to be above the CJ state for PBX 9502. Based on these results, further tests were conducted to isolate and measure the longevity and pressure of this phenomenon using a series of cutback tests.
- 1 January 2017
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1793, 060023
The interaction of explosively generated plasma with explosives
It has been shown that the temperature of explosively generated plasma (EGP) is of the order of 1 eV and plasma ejecta can be focused to achieve velocities as high as 25 km/s. Proof-of-principle tests were performed to determine if EGP could be used for explosive ordnance demolition and other applications. The goals were: to benignly disable ordnance containing relatively sensitive high performance explosives (PBX-9501); and to investigate the possibility of interrupting an ongoing detonation in a powerful high explosive (again PBX-9501) with EGP. Experiments were performed to establish the optimum sizes of plasma generators for the benign deactivation of high explosives, i.e., the destruction of the ordnance without initiating a detonation or comparable violent event. These experiments were followed by attempts to interrupt an ongoing detonation by the benign disruption of the unreacted explosive in its path. The results were encouraging. First, it was demonstrated that high explosives could be destroyed without the initiation of a detonation or high order reaction. Second, ongoing detonations were successfully interrupted with EGP. [LA-UR-15-25350]
- 1 January 2017
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1793, 060023
The interaction of explosively generated plasma with explosives
It has been shown that the temperature of explosively generated plasma (EGP) is of the order of 1 eV and plasma ejecta can be focused to achieve velocities as high as 25 km/s. Proof-of-principle tests were performed to determine if EGP could be used for explosive ordnance demolition and other applications. The goals were: to benignly disable ordnance containing relatively sensitive high performance explosives (PBX-9501); and to investigate the possibility of interrupting an ongoing detonation in a powerful high explosive (again PBX-9501) with EGP. Experiments were performed to establish the optimum sizes of plasma generators for the benign deactivation of high explosives, i.e., the destruction of the ordnance without initiating a detonation or comparable violent event. These experiments were followed by attempts to interrupt an ongoing detonation by the benign disruption of the unreacted explosive in its path. The results were encouraging. First, it was demonstrated that high explosives could be destroyed without the initiation of a detonation or high order reaction. Second, ongoing detonations were successfully interrupted with EGP. [LA-UR-15-25350]
- Open Access
- 1 June 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21584915,p. 1516-1521
Isentropic compression studies at the Los Alamos National High Magnetic Field Laboratory
A single-turn magnet pulsed power system at the National High Magnetic Field Laboratory (NHMFL) at Los Alamos was originally designed to study actinide samples in extremes of high magnetic field (to 300 Tesla) [1, 2]. A simple modification to the single-turn magnet has converted it to a fast turnaround dynamic high pressure measurement system for Isentropic Compression Experiments (ICE). This paper details the work done including design, theory, modeling and results. The NHMFL system has the advantage of a relatively long-duration current with a ~2.3-μs rise time, which allows for large sample dimensions, i.e., up to 5 mm thickness, see II.D. The maximum stress is ~50GPa (0.5 Mbar) at the maximum bank voltage (60 kV); higher stresses may be obtained with modifications to the load design. For the design and predictions of performance of the NHMFL-ICE experiment it is important to have good numerical models. A novel SPICE code simulation was chosen to model all aspects of the experiment, electrical and physical. To this end, accurate dynamic load models were developed to simulate the compression and expansion of the dynamic load at high pressures using shock physics principles. In this study feasibility of adapting the existing NHMFL capacitor bank for ICE experiments up to 100 GPa is demonstrated. The adaptation saved the expense of building a dedicated capacitor bank yet this new system produces high quality ICE data with a rapid turnaround and very low cost per experiment. A series of proof-of-principle experiments [3] demonstrated the feasibility of the NHMFL-ICE technique; some of the results will be shown here to illustrate the effectiveness of the new technique.
- 1 June 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21584915,p. 1516-1521
Open AccessIsentropic compression studies at the Los Alamos National High Magnetic Field Laboratory
A single-turn magnet pulsed power system at the National High Magnetic Field Laboratory (NHMFL) at Los Alamos was originally designed to study actinide samples in extremes of high magnetic field (to 300 Tesla) [1, 2]. A simple modification to the single-turn magnet has converted it to a fast turnaround dynamic high pressure measurement system for Isentropic Compression Experiments (ICE). This paper details the work done including design, theory, modeling and results. The NHMFL system has the advantage of a relatively long-duration current with a ~2.3-μs rise time, which allows for large sample dimensions, i.e., up to 5 mm thickness, see II.D. The maximum stress is ~50GPa (0.5 Mbar) at the maximum bank voltage (60 kV); higher stresses may be obtained with modifications to the load design. For the design and predictions of performance of the NHMFL-ICE experiment it is important to have good numerical models. A novel SPICE code simulation was chosen to model all aspects of the experiment, electrical and physical. To this end, accurate dynamic load models were developed to simulate the compression and expansion of the dynamic load at high pressures using shock physics principles. In this study feasibility of adapting the existing NHMFL capacitor bank for ICE experiments up to 100 GPa is demonstrated. The adaptation saved the expense of building a dedicated capacitor bank yet this new system produces high quality ICE data with a rapid turnaround and very low cost per experiment. A series of proof-of-principle experiments [3] demonstrated the feasibility of the NHMFL-ICE technique; some of the results will be shown here to illustrate the effectiveness of the new technique.