NRNik Rajic

Nik Rajic

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nik Rajic has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Stress visualization in geometrically complex structures using Thermoelastic Stress Analysis and Augmented Reality

    by Ayman Mukhaimar, Ruwan Tennakoon, Nik Rajic, Fabio Zambetta, Pier Marzocca, Reza Hoseinnezhad, Chris Brooks, Stephen Van Der Velden, Kheang Khauv

  • Open Access

    Thermographic Monitoring of Scum Accumulation beneath Floating Covers

    by Yue Ma, Francis Rose, Leslie Wong, Benjamin Steven Vien, Thomas Kuen, Nik Rajic, Jayantha Kodikara, Wing Kong Chiu

    Large sheets of high-density polyethene geomembrane are used as floating covers on some of the wastewater treatment lagoons at the Melbourne Water Corporation’s Western Treatment Plant. These covers provide an airtight seal for the anaerobic digestion of sewage and allow for harvesting the methane-rich biogas, which is then used to generate electricity. There is a potential for scum to develop under the covers during the anaerobic digestion of the raw sewage by microorganisms. Due to the nature of the operating environment of the lagoons and the vast size (450 m × 170 m) of these covers, a safe non-contact method to monitor the development and movement of the scum is preferred. This paper explores the potential of using a new thermographic approach to identify and monitor the scum under the covers. The approach exploits naturally occurring variations in solar intensity as a trigger for generating a transient thermal response that is then fitted to an exponential decay law to determine a cooling constant. This approach is investigated experimentally using a laboratory-scale test rig. A finite element (FE) model is constructed and shown to reliably predict the experimentally observed thermal transients and cooling constants. This FE model is then set up to simulate progressive scum accumulation with time, using a specified scumberg geometry and a stepwise change in thermal properties. The results indicate a detectable change in the cooling constant at different locations on the cover, thereby providing a quantitative basis for characterising the scum accumulation beneath the cover. The practical application and limitations of these results are briefly discussed.


  • Open Access

    Detection of Defects in Geomembranes Using Quasi-Active Infrared Thermography

    by Yue Ma, Francis Rose, Leslie Wong, Benjamin Steven Vien, Thomas Kuen, Nik Rajic, Jayantha Kodikara, Wingkong Chiu

    High-density polyethylene geomembranes are employed as covers for the sewage treatment lagoons at Melbourne Water Corporation’s Western Treatment Plant, to harvest the biogas produced during anaerobic degradation, which is then used to generate electricity. Due to its size, inspecting the cover for defects, particularly subsurface defects, can be challenging, as well as the potential for the underside of the membrane to come into contact with different substrates, viz. liquid sewage, scum (consolidated solid matter), and biogas. This paper presents the application of a novel quasi-active thermography inspection method for subsurface defect detection in the geomembrane. The proposed approach utilises ambient sunlight as the input thermal energy and cloud shading as the trigger for thermal transients. Outdoor laboratory-scale experiments were conducted to study the proposed inspection technique. A pyranometer was used to measure the intensity of solar radiation, and an infrared thermal camera was used to measure the surface temperature of the geomembrane. The measured temperature profile was analysed using three different algorithms for thermal transient analysis, based on (i) the cooling constant from Newton’s law of cooling, (ii) the peak value of the logarithmic second derivative, and (iii) a frame subtraction method. The outcomes from each algorithm were examined and compared. The results show that, while each algorithm has some limitations, when used in combination the three algorithms could be used to distinguish between different substrates and to determine the presence of subsurface defects.


  • In situ wavenumber–frequency modal decomposition of acoustic emissions

    by Nik Rajic, Cedric Rosalie, Benjamin Steven Vien, Stephen van der Velden, Lr Francis Rose, Joel Smithard, Wing Kong Chiu

    A new acoustic sensing capability, consisting of a flexible high-density linear piezoelectric sensor array coupled to a high-bandwidth interrogation device, is developed and applied to in situ wavenumber–frequency modal decomposition of acoustic emissions in plates. An experimental assessment of the capability is undertaken using acoustic emissions generated by a ball-drop impact on aluminium and composite panels. A new method for acoustic source localisation based on this new sensor array is described, and it is shown to be more accurate than a conventional multilateration technique using single-point piezoelectric receivers. The potential of this new capability for acoustic emission detection, location and possible quantification is discussed.


  • In situ thermoelastic stress analysis – an improved approach to airframe structural model validation

    by Nik Rajic, David McSwiggen, Marcus McDonald, Don Whiteley

    The recent adaptation of uncooled infrared imaging technology to thermoelastic stress analysis (TSA) offers an opportunity to improve the validation basis for structural finite element modelling of complex airframe components. Uncertainties in modelling can lead to inaccurate airframe lifing predictions and premature test failures that delay and add cost to aircraft full-scale durability test programs. Traditional model validation practice relies on data drawn primarily from discrete strain gauge, structural deflection and load-cell measurements. Supplementing this data with full-field stress imagery is shown to lead to a significantly improved model validation capability. After reviewing the fundamentals of TSA and its application using uncooled infrared detectors this article describes an experimental study conducted on an F-35 full-scale durability test airframe. It is shown that small low-cost microbolometers installed on the airframe provide a rapid and unobtrusive means of obtaining high-fidelity full-field stress imagery of complex airframe components. Such data enables a direct and rapid assessment of model accuracy in areas of potentially life-limiting stress concentration where predictive accuracy needs to be most assured but has traditionally been difficult to verify using the established model validation approach. Issues of general relevance to the application of TSA to full-scale durability testing are also discussed.


  • Remote Sensing of Lamb Waves Using Optical Fibres—An Investigation of Modal Composition

    by Claire Davis, Cedric Rosalie, Patrick Norman, Nik Rajic, Joe Habel, Martin Bernier

    This paper reports on an experimental investigation into the differences between directly and remotely bonded optical Fibre Bragg Grating (FBG) sensors when measuring Lamb waves in an aluminium plate. A sensor array comprising 16 individual short gauge-length FBG sensing elements is used to decompose the wave into its constituent modes for the directly bonded case where the array is attached directly to the plate and for the remotely bonded case where the same array is located in a suspended fibre 250 mm downstream from the fibre/plate contact region. The experimental results were consistent with model predictions and show that while the directly bonded fibre array can resolve the full multimodal Lamb wave spectrum in the plate, the remotely bonded sensor measures only a single non-dispersive longitudinal acoustic mode predicted by the analytical solution for a cylindrical waveguide. The inability of remote sensing to distinguish between different modes of Lamb wave propagation represents a significant limitation with respect to the diagnostic utility of this sensing approach.