Francielly Moura de Souza Soares
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Francielly Moura de Souza Soares has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Carlos Nelson Elias
3 shared publications- Ana Isabel de Carvalho Santana
Universidade do Estado do Rio de Janeiro, Brasil
2 shared publications - Carlos Nelson Elias
Materials Science Department, Instituto Militar de Engenharia, Rio de Janeiro 22290-270, Brazil
2 shared publications - Dyanni Manhães Barbosa
Instituto Militar de Engenharia—IME, Department of Materials Science, Praça General Tibúrcio, 80, Praia Vermelha, Urca, CEP 22290-270, Rio de Janeiro, RJ, Brazil
2 shared publications - Emília dos Santos Monteiro
Instituto Militar de Engenharia (IME), Material Science Department, Pr Gen Tiburcio 90, Rio de Janeiro 22290-270, Brazil
2 shared publications - Hazel Paloma Reis Corado
Instituto Militar de Engenharia—IME, Department of Materials Science, Praça General Tibúrcio, 80, Praia Vermelha, Urca, CEP 22290-270, Rio de Janeiro, RJ, Brazil
2 shared publications
Latest Publications
- Open Access
- 30 November 2022
- Published by Wiley in International Journal of Biomaterials
- Vol. 2022, 1-11
Titanium Coated with Graphene and Niobium Pentoxide for Biomaterial Applications
Graphene and niobium oxide are used in biomaterial coatings. In this work, commercially pure titanium (cp Ti) was coated with graphene oxide (GO), niobium pentoxide (Nb2O5), and a mixture of both materials (NbGO) by the electrochemical deposition method. The surface morphology, roughness, wettability, and degradation of coated and uncoated samples were analyzed by scanning electron microscopy, interferometry, and contact angle. The results showed that the specimens coated with NbGO (cp Ti-NbGO) showed the highest surface roughness (Ra=0.64μm) and were hydrophobic. The contact (θ) angle between water and the surface of uncoated specimens (cp Ti), coated with GO (cp Ti-GO), coated with a mixture with GO and Nb2O5) (cp Ti-NbGO), and coated with Nb2O5 were 50.74°, 44.35°, 55.86°, and 100.35°, respectively. The electrochemical corrosion tests showed that coating with graphene oxide increased the corrosion resistance and coating with Nb2O5 decreased the corrosion resistance. The negative effect of the effect of Nb2O5 coating in corrosion resistance compensated for the release of Nb2O5, which helps osseointegration, increasing cell viability, and proliferation of osteoblasts. The NbGO coating may be a good way to combine the bactericidal effect of graphene oxide with the osseointegration effect of Nb2O5.
- 30 November 2022
- Published by Wiley in International Journal of Biomaterials
- Vol. 2022, 1-11
Open AccessTitanium Coated with Graphene and Niobium Pentoxide for Biomaterial Applications
Graphene and niobium oxide are used in biomaterial coatings. In this work, commercially pure titanium (cp Ti) was coated with graphene oxide (GO), niobium pentoxide (Nb2O5), and a mixture of both materials (NbGO) by the electrochemical deposition method. The surface morphology, roughness, wettability, and degradation of coated and uncoated samples were analyzed by scanning electron microscopy, interferometry, and contact angle. The results showed that the specimens coated with NbGO (cp Ti-NbGO) showed the highest surface roughness (Ra=0.64μm) and were hydrophobic. The contact (θ) angle between water and the surface of uncoated specimens (cp Ti), coated with GO (cp Ti-GO), coated with a mixture with GO and Nb2O5) (cp Ti-NbGO), and coated with Nb2O5 were 50.74°, 44.35°, 55.86°, and 100.35°, respectively. The electrochemical corrosion tests showed that coating with graphene oxide increased the corrosion resistance and coating with Nb2O5 decreased the corrosion resistance. The negative effect of the effect of Nb2O5 coating in corrosion resistance compensated for the release of Nb2O5, which helps osseointegration, increasing cell viability, and proliferation of osteoblasts. The NbGO coating may be a good way to combine the bactericidal effect of graphene oxide with the osseointegration effect of Nb2O5.
- Open Access
- 1 November 2022
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 21, 3844-3855
Surface morphology, roughness, and corrosion resistance of dental implants produced by additive manufacturing
- 1 November 2022
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 21, 3844-3855
Open AccessSurface morphology, roughness, and corrosion resistance of dental implants produced by additive manufacturing
- Open Access
- 1 August 2022
- Published by Walter de Gruyter GmbH in Materials Science-Poland
- Vol. 40 (2) , 196-205
Study of synthesis parameters on the physical properties and morphology of smart PNIPAAm hydrogels
Bone loss is common in human old age and new materials that promote bone regeneration are an active line of research. In the present work, seven smart hydrogels based on PNIPAAm were synthesized with the prospective to be used in tissue engineering as a scaffold for bone growth. By changing the stoichiometric concentrations of the reagents and the synthesis parameters, hydrogels with different physical properties and morphology were obtained. Swelling, degradation properties, and crystallinity were analyzed. Physical properties were characterized using 1H-NMR, FTIR, and TGA. The results showed that the swelling degree (degree of mass expansion) varied at room temperature from 1,400% for less rigid hydrogels to 550% for stiffer hydrogels. With heating to body temperature, swelling decreases to 300% and 200%, respectively. The samples presented three-dimensional morphology, but they acquired different structures according to the magnetic stirring during the synthesis process. The crosslink and initiator concentrations have an important effect on the polymeric structure and thermal stability of the hydrogels. The PNIPAAm synthesized using 8.9 and 15.7 mol % of MBA are the most promising compounds to be used in the future as a scaffold for biomedical applications due to their high thermal stability, satisfactory 3D surface morphology, and shrinking-swelling property.
- 1 August 2022
- Published by Walter de Gruyter GmbH in Materials Science-Poland
- Vol. 40 (2) , 196-205
Open AccessStudy of synthesis parameters on the physical properties and morphology of smart PNIPAAm hydrogels
Bone loss is common in human old age and new materials that promote bone regeneration are an active line of research. In the present work, seven smart hydrogels based on PNIPAAm were synthesized with the prospective to be used in tissue engineering as a scaffold for bone growth. By changing the stoichiometric concentrations of the reagents and the synthesis parameters, hydrogels with different physical properties and morphology were obtained. Swelling, degradation properties, and crystallinity were analyzed. Physical properties were characterized using 1H-NMR, FTIR, and TGA. The results showed that the swelling degree (degree of mass expansion) varied at room temperature from 1,400% for less rigid hydrogels to 550% for stiffer hydrogels. With heating to body temperature, swelling decreases to 300% and 200%, respectively. The samples presented three-dimensional morphology, but they acquired different structures according to the magnetic stirring during the synthesis process. The crosslink and initiator concentrations have an important effect on the polymeric structure and thermal stability of the hydrogels. The PNIPAAm synthesized using 8.9 and 15.7 mol % of MBA are the most promising compounds to be used in the future as a scaffold for biomedical applications due to their high thermal stability, satisfactory 3D surface morphology, and shrinking-swelling property.
- Open Access
- 22 October 2021
- Published by Wiley in International Journal of Biomaterials
- Vol. 2021, 1-11
Galvanic Corrosion of Ti Dental Implants Coupled to CoCrMo Prosthetic Component
Dental implant systems are composed of an implant, prosthetic components, and a crown. Since the implants are made of commercially pure Ti (cp Ti) and prosthetic components are often made of Ti and CoCrMo alloys, a galvanic couple between these two devices may lead to galvanic corrosion, ions release, and even loss of the implant. This study aimed to investigate the corrosion resistance and measure the galvanic potential between cp Ti alloys (annealed microstructured cp Ti G4 and cold-worked nanostructured cp Ti G4) and a CoCrMo alloy. The corrosion resistance has been characterized by measuring the open circuit potential, the potentiodynamic polarization, the potentiostatic polarization, and the zero-resistance current. The cp Ti has been tested before and after a surface acid treatment. The samples’ surfaces have been examined by scanning electron microscopy, and their surface roughness has been measured by a 3D optical profilometer. The polarization results showed that the CoCrMo alloy showed lower corrosion resistance than cp Ti. The surface acid treatment improves dental implant corrosion resistance. The galvanic analysis showed that the cp Ti without surface treatment behaved as an anode and after the acid treatment has a cathodic behavior in relation to the CrCoMo alloy. The highest value of galvanic current was cp TiG4 acid etched in contact with CoCrMo, in pH 2 solution. The galvanic couple with the lowest current has been the nanostructured cp Ti in contact with CoCrMo alloy.
- 22 October 2021
- Published by Wiley in International Journal of Biomaterials
- Vol. 2021, 1-11
Open AccessGalvanic Corrosion of Ti Dental Implants Coupled to CoCrMo Prosthetic Component
Dental implant systems are composed of an implant, prosthetic components, and a crown. Since the implants are made of commercially pure Ti (cp Ti) and prosthetic components are often made of Ti and CoCrMo alloys, a galvanic couple between these two devices may lead to galvanic corrosion, ions release, and even loss of the implant. This study aimed to investigate the corrosion resistance and measure the galvanic potential between cp Ti alloys (annealed microstructured cp Ti G4 and cold-worked nanostructured cp Ti G4) and a CoCrMo alloy. The corrosion resistance has been characterized by measuring the open circuit potential, the potentiodynamic polarization, the potentiostatic polarization, and the zero-resistance current. The cp Ti has been tested before and after a surface acid treatment. The samples’ surfaces have been examined by scanning electron microscopy, and their surface roughness has been measured by a 3D optical profilometer. The polarization results showed that the CoCrMo alloy showed lower corrosion resistance than cp Ti. The surface acid treatment improves dental implant corrosion resistance. The galvanic analysis showed that the cp Ti without surface treatment behaved as an anode and after the acid treatment has a cathodic behavior in relation to the CrCoMo alloy. The highest value of galvanic current was cp TiG4 acid etched in contact with CoCrMo, in pH 2 solution. The galvanic couple with the lowest current has been the nanostructured cp Ti in contact with CoCrMo alloy.
- Open Access
- 1 January 2019
- Published by FapUNIFESP (SciELO) in Materials Research
- Vol. 22 (suppl 1)
Influence of oral pH Environment in the Corrosion Resistance of Cr-Co-Mo alloy Used for Dentistry Prosthetic Components
The Cr-Co-Mo alloys are commonly used in dentistry for prosthetic components and dental implant supported prosthesis. These alloys present high corrosion resistance owing to a passive oxide film on the surface. However, the oral environment is an aggressive system, due to pH variation, chloride and fluoride ions presence, that can decrease the metal alloy corrosion resistance. Although Cr-Co-Mo alloys have been used for a long time, their electrochemical properties on different pH have not been studied yet. This study aimed to evaluate the electrochemical properties of Cr-Co-Mo alloy in NaCl 0.9% solution in different pH and mouthwash solution. To imitate the oral environment, electrolytes with a pH equal to 2, 3, and 6 were used. Corrosion studies were performed by open circuit potential observation, potentiodynamic polarization curve, chronoamperometry and electrochemical impedance. The results showed that the analyzed alloy has good corrosion resistance under experimental conditions, although the acidified NaCl 0.9% solution increased the corrosion current, particularly in cathodic potentials.
- 1 January 2019
- Published by FapUNIFESP (SciELO) in Materials Research
- Vol. 22 (suppl 1)
Open AccessInfluence of oral pH Environment in the Corrosion Resistance of Cr-Co-Mo alloy Used for Dentistry Prosthetic Components
The Cr-Co-Mo alloys are commonly used in dentistry for prosthetic components and dental implant supported prosthesis. These alloys present high corrosion resistance owing to a passive oxide film on the surface. However, the oral environment is an aggressive system, due to pH variation, chloride and fluoride ions presence, that can decrease the metal alloy corrosion resistance. Although Cr-Co-Mo alloys have been used for a long time, their electrochemical properties on different pH have not been studied yet. This study aimed to evaluate the electrochemical properties of Cr-Co-Mo alloy in NaCl 0.9% solution in different pH and mouthwash solution. To imitate the oral environment, electrolytes with a pH equal to 2, 3, and 6 were used. Corrosion studies were performed by open circuit potential observation, potentiodynamic polarization curve, chronoamperometry and electrochemical impedance. The results showed that the analyzed alloy has good corrosion resistance under experimental conditions, although the acidified NaCl 0.9% solution increased the corrosion current, particularly in cathodic potentials.