Takamitsu Iwaya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Takamitsu Iwaya has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Hideyuki Fukushi
Tohoku Univ, Ball Wave Inc, Business Incubator T Biz 501, Aoba Ku, 6-6-40 Aza Aoba, Sendai, Miyagi 98908579, Japan
2 shared publications- Kazushi Yamanaka
Ball Wave Inc., Tohoku University Business Incubator T-Biz 501 1 , 6-6-40, Aza Aoba, Aramaki, Aoba, Sendai, Miyagi 980-8579
2 shared publications Maki Sugawara
Tohoku Univ, Ball Wave Inc, Business Incubator T Biz 501, Aoba Ku, 6-6-40 Aza Aoba, Sendai, Miyagi 98908579, Japan
2 shared publicationsNobuo Takeda
Tohoku Univ, Ball Wave Inc, Business Incubator T Biz 501, Aoba Ku, 6-6-40 Aza Aoba, Sendai, Miyagi 98908579, Japan
2 shared publicationsShingo Akao
Tohoku Univ, Ball Wave Inc, Business Incubator T Biz 501, Aoba Ku, 6-6-40 Aza Aoba, Sendai, Miyagi 98908579, Japan
2 shared publicationsTatsuhiro Okano
Tohoku Univ, Ball Wave Inc, Business Incubator T Biz 501, Aoba Ku, 6-6-40 Aza Aoba, Sendai, Miyagi 98908579, Japan
2 shared publications
Latest Publications
- Open Access
- 1 February 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (2)
Development of a large volume injection technique for a portable gas chromatograph with a ball surface acoustic wave sensor
Most portable gas chromatographs (GCs) were designed exclusively for gas samples. If they can handle liquid samples too, the range of application is expected to expand substantially. However, in general, the injection volume of liquid samples in GCs is limited to about 1 μl or less to prevent the loss of analytical precision and instrument contamination. Therefore, it is difficult to achieve sufficient sensitivity with the limited resources of the portable GCs. In this study, we developed a large volume injection (LVI) technique applicable to portable GCs, fabricated a compact LVI–GC using a spherical surface acoustic wave (SAW) sensor (the ball SAW sensor) as the detector, and confirmed its basic operation. Using a sample mixture of linear alkanes with 7–13 carbons in a pentane solvent, we evaluated measurement conditions without the loss of analyte in a sample volume range of ∼5–50 μl and confirmed the linearity of the response with respect to the sample volume. In addition, 1,2-methylenedioxybenzene, a simulant of a hallucinogen, 3,4-methylenedioxymethamphetamine (MDMA), was analyzed for an application in drug analysis in urine, and a detection limit of ∼23 ng/ml, well below the cutoff value of ∼250 ng/ml for MDMA, was achieved. Furthermore, we found a correlation between the response of the ball SAW sensor and the retention index and investigated the possibility of quantitative analysis using retention indices.
- 1 February 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (2)
Open AccessDevelopment of a large volume injection technique for a portable gas chromatograph with a ball surface acoustic wave sensor
Most portable gas chromatographs (GCs) were designed exclusively for gas samples. If they can handle liquid samples too, the range of application is expected to expand substantially. However, in general, the injection volume of liquid samples in GCs is limited to about 1 μl or less to prevent the loss of analytical precision and instrument contamination. Therefore, it is difficult to achieve sufficient sensitivity with the limited resources of the portable GCs. In this study, we developed a large volume injection (LVI) technique applicable to portable GCs, fabricated a compact LVI–GC using a spherical surface acoustic wave (SAW) sensor (the ball SAW sensor) as the detector, and confirmed its basic operation. Using a sample mixture of linear alkanes with 7–13 carbons in a pentane solvent, we evaluated measurement conditions without the loss of analyte in a sample volume range of ∼5–50 μl and confirmed the linearity of the response with respect to the sample volume. In addition, 1,2-methylenedioxybenzene, a simulant of a hallucinogen, 3,4-methylenedioxymethamphetamine (MDMA), was analyzed for an application in drug analysis in urine, and a detection limit of ∼23 ng/ml, well below the cutoff value of ∼250 ng/ml for MDMA, was achieved. Furthermore, we found a correlation between the response of the ball SAW sensor and the retention index and investigated the possibility of quantitative analysis using retention indices.
- Open Access
- 30 May 2022
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 61 (SG) , SG1051
Development of ball surface acoustic wave gas chromatograph for environmental monitoring in spacecraft and its application on the ground
For on-site analysis of surface materials on the Moon, planets, and small bodies and for the monitoring of air quality in crewed spacecraft, we have developed a portable gas chromatograph (GC) equipped with a ball surface acoustic wave (SAW) sensor. In this study, we fabricated a 10 cm cube GC that implements the forward flush method using two metal micro-electro-mechanical-system columns coated with different stationary phases in microchannels fabricated by wet etching and diffusion bonding of stainless-steel plates. Using this GC, we succeeded in analyzing 10 kinds of gas within 10 min. In addition, for the application of the ball SAW GC on the ground, we also developed a palm-sized GC with a single metal capillary column and used it in the analysis of the headspace gas of sake. We showed that the ratio of peak areas differed among odorants depending on the brand and brewing process of sake.
- 30 May 2022
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 61 (SG) , SG1051
Open AccessDevelopment of ball surface acoustic wave gas chromatograph for environmental monitoring in spacecraft and its application on the ground
For on-site analysis of surface materials on the Moon, planets, and small bodies and for the monitoring of air quality in crewed spacecraft, we have developed a portable gas chromatograph (GC) equipped with a ball surface acoustic wave (SAW) sensor. In this study, we fabricated a 10 cm cube GC that implements the forward flush method using two metal micro-electro-mechanical-system columns coated with different stationary phases in microchannels fabricated by wet etching and diffusion bonding of stainless-steel plates. Using this GC, we succeeded in analyzing 10 kinds of gas within 10 min. In addition, for the application of the ball SAW GC on the ground, we also developed a palm-sized GC with a single metal capillary column and used it in the analysis of the headspace gas of sake. We showed that the ratio of peak areas differed among odorants depending on the brand and brewing process of sake.
- Open Access
- 17 April 2020
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 31 (9) , 094003
Dynamic calibration method for a trace moisture analyzer based on the quick response of a ball surface acoustic wave sensor
Measurement of trace moisture is important in industry to maintain the quality and yield of products, such as semiconductors, lithium-ion batteries, and organic electroluminescence devices. In the field, on-site calibration of a trace moisture analyzer is required to maintain its reliability. Given these circumstances, we previously developed a ball surface acoustic wave (SAW) sensor using SAW on spherical piezoelectric elements and reported its quick response as its advantage over other trace moisture analyzers. However, the ultimately short response time of less than 1 s has not been verified, and it has not yet been calibrated on-site. In this study, we developed a system for the injection of saturated water vapor to evaluate the quick response of a trace moisture analyzer, and we verified the quick response time of as short as 0.64 s. It is the shortest response time reported so far. In addition, to realize its on-site calibration, we developed a dynamic calibration method, which takes only 10 min, by the injection of saturated water vapor, in contrast to the presently available static calibration method that takes 10 h. Since this system consists of simple components, it can be downsized. Moreover, because it uses a small amount of saturated water vapor as the calibration gas, it is easy to prepare calibration gases in the field and may be applied to on-site calibration.
- 17 April 2020
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 31 (9) , 094003
Open AccessDynamic calibration method for a trace moisture analyzer based on the quick response of a ball surface acoustic wave sensor
Measurement of trace moisture is important in industry to maintain the quality and yield of products, such as semiconductors, lithium-ion batteries, and organic electroluminescence devices. In the field, on-site calibration of a trace moisture analyzer is required to maintain its reliability. Given these circumstances, we previously developed a ball surface acoustic wave (SAW) sensor using SAW on spherical piezoelectric elements and reported its quick response as its advantage over other trace moisture analyzers. However, the ultimately short response time of less than 1 s has not been verified, and it has not yet been calibrated on-site. In this study, we developed a system for the injection of saturated water vapor to evaluate the quick response of a trace moisture analyzer, and we verified the quick response time of as short as 0.64 s. It is the shortest response time reported so far. In addition, to realize its on-site calibration, we developed a dynamic calibration method, which takes only 10 min, by the injection of saturated water vapor, in contrast to the presently available static calibration method that takes 10 h. Since this system consists of simple components, it can be downsized. Moreover, because it uses a small amount of saturated water vapor as the calibration gas, it is easy to prepare calibration gases in the field and may be applied to on-site calibration.