Ying Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ying Zhou has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Chengyi Li
College of Water Conservancy and Hydropower Engineering, Hohai University, Nanjing 210098, China
1 shared publication - Emmanuel Fernandez-Rodriguez
Technological Institute of Merida, Technological Avenue, Merida 97118, Mexico
1 shared publication - Junhui Xu
College of Energy and Electrical Engineering, Hohai University, Nanjing 210098, China
1 shared publication - Tao Jiang
Management Division of Qinhuai River Hydraulic Engineering of Jiangsu Province, Nanjing 210001, China
1 shared publication - Xiaocui Chen
School of Electrical and Power Engineering, Hohai University, Nanjing 211100, China
1 shared publication - Yuan Zheng
School of Electrical and Power Engineering, Hohai University, Nanjing 211100, China
1 shared publication
Latest Publications
- Open Access
Fatigue Life Study of Francis Pump under Reverse Generation Condition Based on Fluid Solid Coupling
In non-design conditions, severe hydraulic instability can affect the stability of a pump station and even shorten its service life. A Francis pump station in the South-to-North Water Transfer Project was examined to carry out a numerical simulation of the entire flow passage using a bidirectional fluid–solid method for static and fatigue life. Due to the inlet setting, reverse power generation exhibited a more distorted flow pattern that resulted in higher energy loss than the pump condition. The radial force acting on the blades in reverse power generation was 39.1% higher. Runner stress was mainly concentrated at the leading edge and blade edge. The maximum stress in reverse power generation was 35.7 MPa, which was about 28.5% higher than in the pump condition. While the maximum deformation was 0.035 mm, almost 94.4% more severe than in the pump condition, mainly concentrated at the leading edge. Based on the fatigue analysis, a minimum safety factor obtained numerically was 8.238 in the pump condition and 6.343 in the reverse power condition, respectively. The safety factors satisfy the safety standard of the runner material and meet requirements of safety and stability in the reverse power generation condition.
Open AccessFatigue Life Study of Francis Pump under Reverse Generation Condition Based on Fluid Solid Coupling
In non-design conditions, severe hydraulic instability can affect the stability of a pump station and even shorten its service life. A Francis pump station in the South-to-North Water Transfer Project was examined to carry out a numerical simulation of the entire flow passage using a bidirectional fluid–solid method for static and fatigue life. Due to the inlet setting, reverse power generation exhibited a more distorted flow pattern that resulted in higher energy loss than the pump condition. The radial force acting on the blades in reverse power generation was 39.1% higher. Runner stress was mainly concentrated at the leading edge and blade edge. The maximum stress in reverse power generation was 35.7 MPa, which was about 28.5% higher than in the pump condition. While the maximum deformation was 0.035 mm, almost 94.4% more severe than in the pump condition, mainly concentrated at the leading edge. Based on the fatigue analysis, a minimum safety factor obtained numerically was 8.238 in the pump condition and 6.343 in the reverse power condition, respectively. The safety factors satisfy the safety standard of the runner material and meet requirements of safety and stability in the reverse power generation condition.