Guangjun Tan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Guangjun Tan has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Xiaofeng Sun
Key Laboratory of Power Electronics for Energy Conversion and Motor Drive of Hebei Province, Department of Electrical Engineering, Yanshan University, Qinhuangdao, China
6 shared publications - Lei Qi
Key Laboratory of Power Electronics for Energy Conservation and Motor Drive of Hebei Province, Yanshan University, Qinhuangdao 066004, China
3 shared publications - Wei Zhao
Key Lab of Power Electronics for Energy Conservation and Motor Drive of Hebei Province, Department of Electrical Engineering, Yanshan University, Qinhuangdao, China
3 shared publications - Jinlong Wei
Key Lab of Power Electronics for Energy Conservation and Motor Drive of Hebei Province, Department of Electrical Engineering, Yanshan University, Qinhuangdao, China
2 shared publications - Chunan Zong
School of Electrical Engineering, Yanshan University, Qinhuangdao 066004, China
1 shared publication Chunjiang Zhang
1 shared publication
Latest Publications
- 17 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (8) , 11088-11106
Second Harmonic Suppression for DC Output Voltage of Three-Phase Four-Leg PWM Rectifier Under Unbalanced Grid Voltage Conditions
This article proposes a control strategy for three-phase four-leg PWM rectifier under unbalanced grid voltage conditions, which aims at achieving not only no second harmonic in dc output voltage, but also unity power factor operation for each phase. First, the amplitude-phase-locked loop is designed based on three-dimensional unbalanced coordinate transformation to detect the phases of three-phase unbalanced grid voltages, which can be selected as the reference phases of three-phase currents to achieve unity power factor operation for each phase. The second harmonic in dc output voltage can be detected based on Fourier transform principle, and the linear control laws of current amplitude ratios can be designed to suppress second-harmonic ripple completely. The above control objectives for four-leg PWM rectifier can both be achieved with a small dc-link capacitor and without the introduction of an active power compensator, which helps simplify circuit structure and improve power density. The simulation and experimental results are provided in the end to verify the feasibility and effectiveness of the proposed control strategy.
- 17 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (8) , 11088-11106
Second Harmonic Suppression for DC Output Voltage of Three-Phase Four-Leg PWM Rectifier Under Unbalanced Grid Voltage Conditions
This article proposes a control strategy for three-phase four-leg PWM rectifier under unbalanced grid voltage conditions, which aims at achieving not only no second harmonic in dc output voltage, but also unity power factor operation for each phase. First, the amplitude-phase-locked loop is designed based on three-dimensional unbalanced coordinate transformation to detect the phases of three-phase unbalanced grid voltages, which can be selected as the reference phases of three-phase currents to achieve unity power factor operation for each phase. The second harmonic in dc output voltage can be detected based on Fourier transform principle, and the linear control laws of current amplitude ratios can be designed to suppress second-harmonic ripple completely. The above control objectives for four-leg PWM rectifier can both be achieved with a small dc-link capacitor and without the introduction of an active power compensator, which helps simplify circuit structure and improve power density. The simulation and experimental results are provided in the end to verify the feasibility and effectiveness of the proposed control strategy.
- 16 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (12) , 15831-15844
Droop Control of Three- and Four-Leg Hybrid Parallel Inverters Based on Three-Phase Generalized Coordinate Transformation
In recent years, widespread adoption of three-leg inverters has been observed. However, there is often a need for three-phase four-wire inverters to provide a neutral connection for asymmetrical loads within microgrid contexts. This article proposes a three- and four-leg hybrid inverter parallel structure to address the above issues. The aim is to fulfill the four-wire requirement under asymmetrical load conditions and mitigate the voltage unbalance problem. The article begins by investigating the output voltage balance control of three- and four-leg inverters and the control techniques of the hybrid parallel system. Deficiencies in traditional power droop control and virtual impedance control under unbalanced conditions are identified by calculating the inverter's output power under asymmetric load conditions. To address these issues, the article adopts average power droop and proposes a novel virtual impedance method. This method considers the impact of line impedance differences on the distribution accuracy of active power and unbalanced load current, effectively improving their distribution accuracy. Connecting three- and four-leg inverters in parallel, the four-leg inverter is capable of significantly reducing the zero-sequence voltage of the common load terminal and enhances three-phase voltage balance. Finally, experimental results validate the feasibility and effectiveness of the improved virtual impedance control.
- 16 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (12) , 15831-15844
Droop Control of Three- and Four-Leg Hybrid Parallel Inverters Based on Three-Phase Generalized Coordinate Transformation
In recent years, widespread adoption of three-leg inverters has been observed. However, there is often a need for three-phase four-wire inverters to provide a neutral connection for asymmetrical loads within microgrid contexts. This article proposes a three- and four-leg hybrid inverter parallel structure to address the above issues. The aim is to fulfill the four-wire requirement under asymmetrical load conditions and mitigate the voltage unbalance problem. The article begins by investigating the output voltage balance control of three- and four-leg inverters and the control techniques of the hybrid parallel system. Deficiencies in traditional power droop control and virtual impedance control under unbalanced conditions are identified by calculating the inverter's output power under asymmetric load conditions. To address these issues, the article adopts average power droop and proposes a novel virtual impedance method. This method considers the impact of line impedance differences on the distribution accuracy of active power and unbalanced load current, effectively improving their distribution accuracy. Connecting three- and four-leg inverters in parallel, the four-leg inverter is capable of significantly reducing the zero-sequence voltage of the common load terminal and enhances three-phase voltage balance. Finally, experimental results validate the feasibility and effectiveness of the improved virtual impedance control.
- 10 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (10) , 11686-11703
Application of Three-Dimensional Unbalanced Coordinate Transformation to Stand-Alone Four-Leg Voltage-Source Inverter
Three-phase four-leg voltage-source inverter has been extensively investigated in recent years for its compactness, small size, and high efficiency, and it has been proved to be the best solution for providing transformer-less neutral connection to three-phase asymmetric loads. The main purpose of this article is to apply 3-D unbalanced coordinate transformation to the four-leg inverter, which supplies stand-alone asymmetric loads, to maintain the balance of the output capacitor voltages, and obtain simpler control structure and better control performance. First, a double closed-loop PI control structure can be designed based on the Clarke and Park transformations. Second, the phases and amplitudes of the capacitor voltages are locked based on the 3-D unbalanced coordinate transformation. Furthermore, the Clarke transformation oriented on the inductor currents is replaced by a 3-D unbalanced coordinate transformation, and the corresponding unbalance indices are continuously adjusted according to the unbalance indices of the capacitor voltages, so as to recover the capacitor voltages to the balanced condition. The simulation and experimental results of the whole control system for the four-leg inverter are provided in the end, so as to verify the feasibility and effectiveness of the 3-D unbalanced coordinate transformation for application to the power electronic systems.
- 10 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (10) , 11686-11703
Application of Three-Dimensional Unbalanced Coordinate Transformation to Stand-Alone Four-Leg Voltage-Source Inverter
Three-phase four-leg voltage-source inverter has been extensively investigated in recent years for its compactness, small size, and high efficiency, and it has been proved to be the best solution for providing transformer-less neutral connection to three-phase asymmetric loads. The main purpose of this article is to apply 3-D unbalanced coordinate transformation to the four-leg inverter, which supplies stand-alone asymmetric loads, to maintain the balance of the output capacitor voltages, and obtain simpler control structure and better control performance. First, a double closed-loop PI control structure can be designed based on the Clarke and Park transformations. Second, the phases and amplitudes of the capacitor voltages are locked based on the 3-D unbalanced coordinate transformation. Furthermore, the Clarke transformation oriented on the inductor currents is replaced by a 3-D unbalanced coordinate transformation, and the corresponding unbalance indices are continuously adjusted according to the unbalance indices of the capacitor voltages, so as to recover the capacitor voltages to the balanced condition. The simulation and experimental results of the whole control system for the four-leg inverter are provided in the end, so as to verify the feasibility and effectiveness of the 3-D unbalanced coordinate transformation for application to the power electronic systems.
- 28 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Three-Dimensional Coordinate Transformation Theory for Three-Phase Four-Wire Unbalanced Power Electronic System
This paper proposes a three-dimensional coordinate transformation theory, which can convert three-phase unbalanced ac quantities into balanced two-phase orthogonal ac quantities and one constant dc quantity, and these three quantities can be further converted into three constant dc quantities by using three-dimensional Park coordinate transformation. By applying the proposed three-dimensional coordinate transformation along with three-dimensional Park coordinate transformation to three-phase four-wire or four-leg unbalanced ac power electronic systems, these ac power electronic systems can be directly converted into dc power electronic systems, so the proportional-integral controllers can be employed to realize the error-free control of the three-phase unbalanced currents for these ac power electronic systems.
- 28 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Three-Dimensional Coordinate Transformation Theory for Three-Phase Four-Wire Unbalanced Power Electronic System
This paper proposes a three-dimensional coordinate transformation theory, which can convert three-phase unbalanced ac quantities into balanced two-phase orthogonal ac quantities and one constant dc quantity, and these three quantities can be further converted into three constant dc quantities by using three-dimensional Park coordinate transformation. By applying the proposed three-dimensional coordinate transformation along with three-dimensional Park coordinate transformation to three-phase four-wire or four-leg unbalanced ac power electronic systems, these ac power electronic systems can be directly converted into dc power electronic systems, so the proportional-integral controllers can be employed to realize the error-free control of the three-phase unbalanced currents for these ac power electronic systems.
- Open Access
- 20 April 2020
- Published by MDPI AG in Electronics
- Vol. 9 (4) , 674
Tan-Sun Transformation-Based Phase-Locked Loop in Detection of the Grid Synchronous Signals under Distorted Grid Conditions
When three-phase voltages are polluted with unbalance, DC offsets, or higher harmonics, it is a challenge to quickly detect their parameters such as phases, frequency, and amplitudes. This paper proposes a phase-locked loop (PLL) for the three-phase non-ideal voltages based on the decoupling network composed of two submodules. One submodule is used to detect the parameters of the fundamental and direct-current voltages based on Tan-Sun transformation, and the other is used to detect the parameters of the higher-harmonic voltages based on Clarke transformation. By selecting the proper decoupling vector by mapping Hilbert space to Euclidean space, the decoupling control for each estimated parameter can be realized. The settling time of the control law can be set the same for each estimated parameter to further improve the response speed of the whole PLL system. The system order equals the number of the estimated parameters in each submodule except that a low-pass filter is required to estimate the average amplitude of the fundamental voltages, so the whole PLL structure is very simple. The simulation and experimental results are provided in the end to validate the effectiveness of the proposed PLL technique in terms of the steady and transient performance.
- 20 April 2020
- Published by MDPI AG in Electronics
- Vol. 9 (4) , 674
Open AccessTan-Sun Transformation-Based Phase-Locked Loop in Detection of the Grid Synchronous Signals under Distorted Grid Conditions
When three-phase voltages are polluted with unbalance, DC offsets, or higher harmonics, it is a challenge to quickly detect their parameters such as phases, frequency, and amplitudes. This paper proposes a phase-locked loop (PLL) for the three-phase non-ideal voltages based on the decoupling network composed of two submodules. One submodule is used to detect the parameters of the fundamental and direct-current voltages based on Tan-Sun transformation, and the other is used to detect the parameters of the higher-harmonic voltages based on Clarke transformation. By selecting the proper decoupling vector by mapping Hilbert space to Euclidean space, the decoupling control for each estimated parameter can be realized. The settling time of the control law can be set the same for each estimated parameter to further improve the response speed of the whole PLL system. The system order equals the number of the estimated parameters in each submodule except that a low-pass filter is required to estimate the average amplitude of the fundamental voltages, so the whole PLL structure is very simple. The simulation and experimental results are provided in the end to validate the effectiveness of the proposed PLL technique in terms of the steady and transient performance.