Loretta A. Fernandez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Loretta A. Fernandez has a total of 85 co-authors. Here are the top co-authors by number of shared publications:
Philip M. Gschwend
RM Parsons Laboratory, Department of Civil and Environmental Engineering , Massachusetts Institute of Technology , Cambridge , Massachusetts 02139 , United States
5 shared publications- Robert M. Burgess
U.S. Environmental Protection Agency, ORD/CEMM Atlantic Coastal Environmental Sciences Division, 27 Tarzwell Drive, Narragansett, RI 02882, USA
4 shared publications Keith A. Maruya
Southern California Coastal Water Research Project Authority. 3535 Harbor Boulevard, Suite 110 , Costa Mesa , California 92626 , United States
3 shared publicationsRobert M. Burgess
Atlantic Ecology Division, Office of Research and Development , U.S. Environmental Protection Agency , Narragansett , Rhode Island 02882 , United States
3 shared publicationsWenjian Lao
Southern California Coastal Water Research Project Authority. 3535 Harbor Boulevard, Suite 110 , Costa Mesa , California 92626 , United States
3 shared publicationsAlice P. Wang
Department of Civil and Environmental Engineering, Northeastern University, Boston, Massachusetts, USA
2 shared publications
Latest Publications
- Open Access
- 28 May 2021
- Published by American Chemical Society (ACS)
Degradation of dissolved RDX, NQ, and DNAN by cathodic processes in an electrochemical flow-through reactor
- 28 May 2021
- Published by American Chemical Society (ACS)
Open AccessDegradation of dissolved RDX, NQ, and DNAN by cathodic processes in an electrochemical flow-through reactor
- 12 July 2020
- Published by Taylor & Francis in Environmental Forensics
- Vol. 21 (3-4) , 319-333
A forensic approach for distinguishing PFAS materials
The widespread detection of per- and polyfluoroalkyl substances (PFAS) throughout the world and the ongoing proliferation of environmental regulations has prompted the need for a forensic approach for the source attribution of PFAS. Current LC-MS/MS standard methods are sensitive and robust, but only characterize a small fraction of the total potential PFAS signature. Other, more powerful analytical tools such as HRMS exist, and have been used to characterize some of the unknown or “non-target” fraction of PFAS, but these methods are expensive and not widely available. This paper presents a tiered approach to PFAS forensics based on standard methods and/or other relatively inexpensive methodologies. The approach outlined herein is broken into three tiers, including (1) a screening method to assess the general characteristics of the bulk PFAS signature; (2) a standard method to sensitively measure PFAS compounds of regulatory interest; and (3) a method for resolving the isomer patterns of select PFAS compounds. The combination of these readily accessible methods is illustrated herein with different source materials, including aqueous film forming foam (AFFF) concentrate samples and food contact materials (FCMs). The tiered PFAS forensic approach bridges the gap between ground breaking academic methods and production laboratory throughput for the purpose of identifying valuable forensic information available in PFAS source materials.
- 12 July 2020
- Published by Taylor & Francis in Environmental Forensics
- Vol. 21 (3-4) , 319-333
A forensic approach for distinguishing PFAS materials
The widespread detection of per- and polyfluoroalkyl substances (PFAS) throughout the world and the ongoing proliferation of environmental regulations has prompted the need for a forensic approach for the source attribution of PFAS. Current LC-MS/MS standard methods are sensitive and robust, but only characterize a small fraction of the total potential PFAS signature. Other, more powerful analytical tools such as HRMS exist, and have been used to characterize some of the unknown or “non-target” fraction of PFAS, but these methods are expensive and not widely available. This paper presents a tiered approach to PFAS forensics based on standard methods and/or other relatively inexpensive methodologies. The approach outlined herein is broken into three tiers, including (1) a screening method to assess the general characteristics of the bulk PFAS signature; (2) a standard method to sensitively measure PFAS compounds of regulatory interest; and (3) a method for resolving the isomer patterns of select PFAS compounds. The combination of these readily accessible methods is illustrated herein with different source materials, including aqueous film forming foam (AFFF) concentrate samples and food contact materials (FCMs). The tiered PFAS forensic approach bridges the gap between ground breaking academic methods and production laboratory throughput for the purpose of identifying valuable forensic information available in PFAS source materials.
- 12 May 2020
- Published by Oxford University Press (OUP) in Environmental Toxicology and Chemistry
- Vol. 39 (6) , 1165-1173
In Situ Investigation of Performance Reference Compound-Based Estimates of PCB Equilibrated Passive Sampler Concentrations and Cfree in the Marine Water Column
Low‐Density polyethylene (PE) sheets are used as passive samplers for aquatic environmental monitoring to measure the freely dissolved concentration (Cfree) of hydrophobic organic contaminants (HOCs). Freely dissolved HOCs in water will partition into the PE until a thermodynamic equilibrium is achieved; that is, the HOC's activity in the passive sampler is the same as its activity in the surrounding environment. One way to evaluate the equilibrium status or estimate the uptake kinetics is by using performance reference compounds (PRCs). A fractional equilibrium (feq) can be determined for target HOCs, under the assumption that PRC desorption from the passive sampler occurs at the same rate as the unlabeled target HOCs. However, few investigations have evaluated how effectively and accurately PRCs estimate target contaminant Cfree under in situ conditions. In this study, PE passive samplers were pre‐loaded with six, 13C‐labelled PCBs as PRCs, and deployed in New Bedford Harbor, MA, USA and were collected after 30, 56, 99, and 129‐day deployments. Using this unique temporal sampling design, PRC results from each deployment were fit to a diffusion model to estimate the Cfree of 27 PCB congeners and compare the results between the different deployment times. Smaller PCBs had variable concentrations over the four deployments while mid‐molecular weight PCBs had consistent Cfree measurements for all deployments (relative standard deviation < 20%). High molecular weight PCBs had the largest Cfree estimates after 30 days, these estimates and their standard deviations decreased with longer deployment times. These findings suggest when targeting PCBs with more than six chlorines or contaminants with a log KOW ≥ 6.5, a deployment time longer than 30 days may be prudent.
- 12 May 2020
- Published by Oxford University Press (OUP) in Environmental Toxicology and Chemistry
- Vol. 39 (6) , 1165-1173
In Situ Investigation of Performance Reference Compound-Based Estimates of PCB Equilibrated Passive Sampler Concentrations and Cfree in the Marine Water Column
Low‐Density polyethylene (PE) sheets are used as passive samplers for aquatic environmental monitoring to measure the freely dissolved concentration (Cfree) of hydrophobic organic contaminants (HOCs). Freely dissolved HOCs in water will partition into the PE until a thermodynamic equilibrium is achieved; that is, the HOC's activity in the passive sampler is the same as its activity in the surrounding environment. One way to evaluate the equilibrium status or estimate the uptake kinetics is by using performance reference compounds (PRCs). A fractional equilibrium (feq) can be determined for target HOCs, under the assumption that PRC desorption from the passive sampler occurs at the same rate as the unlabeled target HOCs. However, few investigations have evaluated how effectively and accurately PRCs estimate target contaminant Cfree under in situ conditions. In this study, PE passive samplers were pre‐loaded with six, 13C‐labelled PCBs as PRCs, and deployed in New Bedford Harbor, MA, USA and were collected after 30, 56, 99, and 129‐day deployments. Using this unique temporal sampling design, PRC results from each deployment were fit to a diffusion model to estimate the Cfree of 27 PCB congeners and compare the results between the different deployment times. Smaller PCBs had variable concentrations over the four deployments while mid‐molecular weight PCBs had consistent Cfree measurements for all deployments (relative standard deviation < 20%). High molecular weight PCBs had the largest Cfree estimates after 30 days, these estimates and their standard deviations decreased with longer deployment times. These findings suggest when targeting PCBs with more than six chlorines or contaminants with a log KOW ≥ 6.5, a deployment time longer than 30 days may be prudent.
- Open Access
Quantitative Method for Comparative Assessment of Particle Filtration Efficiency of Fabric Masks as Alternatives to Standard Surgical Masks for PPE
Summary: In response to the COVID-19 pandemic, cloth masks are being used to control the spread of virus, but the efficacy of these loose-fitting masks is not well known. Here, tools and methods typically used to assess tight-fitting respirators were modified to quantify the efficacy of community- and commercially-produced fabric masks as PPE. Two particle counters concurrently sample ambient air and air inside the masks; mask performance is evaluated by mean particle removal efficiency and statistical variability when worn as designed and with a nylon overlayer, to independently assess fit and material. Worn as designed both commercial surgical masks and cloth masks had widely varying effectiveness (53-75% and 28-90% filtration efficiency, respectively). Most surgical-style masks improved with the nylon overlayer, indicating poor fit. This rapid testing method uses widely available hardware, requires only a few calculations from collected data, and provides both a holistic and aspect-wise evaluation of mask performance.
Open AccessQuantitative Method for Comparative Assessment of Particle Filtration Efficiency of Fabric Masks as Alternatives to Standard Surgical Masks for PPE
Summary: In response to the COVID-19 pandemic, cloth masks are being used to control the spread of virus, but the efficacy of these loose-fitting masks is not well known. Here, tools and methods typically used to assess tight-fitting respirators were modified to quantify the efficacy of community- and commercially-produced fabric masks as PPE. Two particle counters concurrently sample ambient air and air inside the masks; mask performance is evaluated by mean particle removal efficiency and statistical variability when worn as designed and with a nylon overlayer, to independently assess fit and material. Worn as designed both commercial surgical masks and cloth masks had widely varying effectiveness (53-75% and 28-90% filtration efficiency, respectively). Most surgical-style masks improved with the nylon overlayer, indicating poor fit. This rapid testing method uses widely available hardware, requires only a few calculations from collected data, and provides both a holistic and aspect-wise evaluation of mask performance.
- 1 December 2019
- Published by Elsevier in Water Research
- Vol. 167, 115109
Side-stream enhanced biological phosphorus removal (S2EBPR) process improves system performance - A full-scale comparative study
- 1 December 2019
- Published by Elsevier in Water Research
- Vol. 167, 115109
Side-stream enhanced biological phosphorus removal (S2EBPR) process improves system performance - A full-scale comparative study
- 24 June 2019
- Published by Oxford University Press (OUP) in Environmental Toxicology and Chemistry
- Vol. 38 (10) , 2326-2336
Bioaccumulation in Functionally Different Species: Ongoing Input of PCBs with Sediment Deposition to Activated Carbon Remediated Bed Sediments
Activated carbon‐amended bed sediments reduced total polychlorinated biphenyl (PCB) accumulation in 3 functionally different marine species, sandworms (Alitta virens), hard clams (Mercenaria mercenaria), and sheepshead minnows (Cyprinodon variegatus), during both clean and contaminated ongoing sediment inputs. Mesocosm experiments were conducted for 90 d to evaluate native, field‐aged bed sediment PCBs, and ongoing input PCBs added 3 times a week. Simulated in situ remediation applied an activated carbon dose equal to the native organic carbon content that was premixed into the bed sediment for 1 mo. The highest bioaccumulation of native PCBs was in worms that remained in and directly ingested the sediment, whereas the highest bioaccumulation of the input PCBs was in fish that were exposed to the water column. When periodic PCB‐contaminated sediment inputs were introduced to the water column, the activated carbon remedy had minimal effect on the input PCBs, whereas the native bed PCBs still dominated bioaccumulation in the control (no activated carbon). Therefore, remediation of only the local bedded sediment in environmental systems with ongoing contaminant inputs may have lower efficacy for fish and other pelagic and epibenthic organisms. While ongoing inputs continue to obscure remedial outcomes at contaminated sediment sites, the present study showed clear effectiveness of activated carbon amendment remediation on native PCBs despite these inputs but no remediation effectiveness for the input‐associated PCBs (at least within the present study duration). Environ Toxicol Chem 2019;38:2326–2336. Published 2019 Wiley Periodicals Inc. on behalf of SETAC. This article is a US government work and, as such, is in the public domain in the United States of America.
- 24 June 2019
- Published by Oxford University Press (OUP) in Environmental Toxicology and Chemistry
- Vol. 38 (10) , 2326-2336
Bioaccumulation in Functionally Different Species: Ongoing Input of PCBs with Sediment Deposition to Activated Carbon Remediated Bed Sediments
Activated carbon‐amended bed sediments reduced total polychlorinated biphenyl (PCB) accumulation in 3 functionally different marine species, sandworms (Alitta virens), hard clams (Mercenaria mercenaria), and sheepshead minnows (Cyprinodon variegatus), during both clean and contaminated ongoing sediment inputs. Mesocosm experiments were conducted for 90 d to evaluate native, field‐aged bed sediment PCBs, and ongoing input PCBs added 3 times a week. Simulated in situ remediation applied an activated carbon dose equal to the native organic carbon content that was premixed into the bed sediment for 1 mo. The highest bioaccumulation of native PCBs was in worms that remained in and directly ingested the sediment, whereas the highest bioaccumulation of the input PCBs was in fish that were exposed to the water column. When periodic PCB‐contaminated sediment inputs were introduced to the water column, the activated carbon remedy had minimal effect on the input PCBs, whereas the native bed PCBs still dominated bioaccumulation in the control (no activated carbon). Therefore, remediation of only the local bedded sediment in environmental systems with ongoing contaminant inputs may have lower efficacy for fish and other pelagic and epibenthic organisms. While ongoing inputs continue to obscure remedial outcomes at contaminated sediment sites, the present study showed clear effectiveness of activated carbon amendment remediation on native PCBs despite these inputs but no remediation effectiveness for the input‐associated PCBs (at least within the present study duration). Environ Toxicol Chem 2019;38:2326–2336. Published 2019 Wiley Periodicals Inc. on behalf of SETAC. This article is a US government work and, as such, is in the public domain in the United States of America.
- 27 December 2018
- Published by Oxford University Press (OUP) in Integrated Environmental Assessment and Management
- Vol. 15 (1) , 163-164
Demographics near waste-to-energy plants: Poverty-level changes from 2000 to 2015
- 27 December 2018
- Published by Oxford University Press (OUP) in Integrated Environmental Assessment and Management
- Vol. 15 (1) , 163-164
Demographics near waste-to-energy plants: Poverty-level changes from 2000 to 2015
- Open Access
- 28 February 2018
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 52 (6) , 3574-3582
Advancing the Use of Passive Sampling in Risk Assessment and Management of Sediments Contaminated with Hydrophobic Organic Chemicals: Results of an International Ex Situ Passive Sampling Interlaboratory Comparison
This work presents the results of an international interlaboratory comparison on ex situ passive sampling in sediments. The main objectives were to map the state of the science in passively sampling sediments, identify sources of variability, provide recommendations and practical guidance for standardized passive sampling, and advance the use of passive sampling in regulatory decision making by increasing confidence in the use of the technique. The study was performed by a consortium of 11 laboratories and included experiments with 14 passive sampling formats on 3 sediments for 25 target chemicals (PAHs and PCBs). The resulting overall interlaboratory variability was large (a factor of ∼10), but standardization of methods halved this variability. The remaining variability was primarily due to factors not related to passive sampling itself, i.e., sediment heterogeneity and analytical chemistry. Excluding the latter source of variability, by performing all analyses in one laboratory, showed that passive sampling results can have a high precision and a very low intermethod variability (<factor of 1.7). It is concluded that passive sampling, irrespective of the specific method used, is fit for implementation in risk assessment and management of contaminated sediments, provided that method setup and performance, as well as chemical analyses are quality-controlled.
- 28 February 2018
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 52 (6) , 3574-3582
Open AccessAdvancing the Use of Passive Sampling in Risk Assessment and Management of Sediments Contaminated with Hydrophobic Organic Chemicals: Results of an International Ex Situ Passive Sampling Interlaboratory Comparison
This work presents the results of an international interlaboratory comparison on ex situ passive sampling in sediments. The main objectives were to map the state of the science in passively sampling sediments, identify sources of variability, provide recommendations and practical guidance for standardized passive sampling, and advance the use of passive sampling in regulatory decision making by increasing confidence in the use of the technique. The study was performed by a consortium of 11 laboratories and included experiments with 14 passive sampling formats on 3 sediments for 25 target chemicals (PAHs and PCBs). The resulting overall interlaboratory variability was large (a factor of ∼10), but standardization of methods halved this variability. The remaining variability was primarily due to factors not related to passive sampling itself, i.e., sediment heterogeneity and analytical chemistry. Excluding the latter source of variability, by performing all analyses in one laboratory, showed that passive sampling results can have a high precision and a very low intermethod variability (<factor of 1.7). It is concluded that passive sampling, irrespective of the specific method used, is fit for implementation in risk assessment and management of contaminated sediments, provided that method setup and performance, as well as chemical analyses are quality-controlled.
- Open Access
- 2 August 2017
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 51 (17) , 9996-10004
Cross Validation of Two Partitioning-Based Sampling Approaches in Mesocosms Containing PCB Contaminated Field Sediment, Biota, and Activated Carbon Amendment
The Gold Standard for determining freely dissolved concentrations (Cfree) of hydrophobic organic compounds in sediment interstitial water would be in situ deployment combined with equilibrium sampling, which is generally difficult to achieve. In the present study, ex situ equilibrium sampling with multiple thicknesses of silicone and in situ pre-equilibrium sampling with low density polyethylene (LDPE) loaded with performance reference compounds were applied independently to measure polychlorinated biphenyls (PCBs) in mesocosms with (1) New Bedford Harbor sediment (MA, U.S.A.), (2) sediment and biota, and (3) activated carbon amended sediment and biota. The aim was to cross validate the two different sampling approaches. Around 100 PCB congeners were quantified in the two sampling polymers, and the results confirmed the good precision of both methods and were in overall good agreement with recently published LDPE to silicone partition ratios. Further, the methods yielded Cfree in good agreement for all three experiments. The average ratio between Cfree determined by the two methods was factor 1.4 ± 0.3 (range: 0.6–2.0), and the results thus cross-validated the two sampling approaches. For future investigations, specific aims and requirements in terms of application, data treatment, and data quality requirements should dictate the selection of the most appropriate partitioning-based sampling approach.
- 2 August 2017
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 51 (17) , 9996-10004
Open AccessCross Validation of Two Partitioning-Based Sampling Approaches in Mesocosms Containing PCB Contaminated Field Sediment, Biota, and Activated Carbon Amendment
The Gold Standard for determining freely dissolved concentrations (Cfree) of hydrophobic organic compounds in sediment interstitial water would be in situ deployment combined with equilibrium sampling, which is generally difficult to achieve. In the present study, ex situ equilibrium sampling with multiple thicknesses of silicone and in situ pre-equilibrium sampling with low density polyethylene (LDPE) loaded with performance reference compounds were applied independently to measure polychlorinated biphenyls (PCBs) in mesocosms with (1) New Bedford Harbor sediment (MA, U.S.A.), (2) sediment and biota, and (3) activated carbon amended sediment and biota. The aim was to cross validate the two different sampling approaches. Around 100 PCB congeners were quantified in the two sampling polymers, and the results confirmed the good precision of both methods and were in overall good agreement with recently published LDPE to silicone partition ratios. Further, the methods yielded Cfree in good agreement for all three experiments. The average ratio between Cfree determined by the two methods was factor 1.4 ± 0.3 (range: 0.6–2.0), and the results thus cross-validated the two sampling approaches. For future investigations, specific aims and requirements in terms of application, data treatment, and data quality requirements should dictate the selection of the most appropriate partitioning-based sampling approach.