Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Lisheng Zhong has a total of 190 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Robust Machine Learning Framework for Condition Monitoring and Health Index Prediction of Medium Voltage XLPE Cables

    by Muhammad Yaqoob, Li Fei, Muhammad Huzaif, Muneeb Ahmed, Roland Dongping Zhang, Lisheng Zhong, Jinghui Gao

    Ondition monitoring of medium voltage (MV) XLPE cables is increasingly critical for the sustainable and secure operation of power systems. Conventional data-driven methods face limitations in voltage specificity, sensitivity to degraded conditions, and reliability under real-world circumstances. This paper introduces a robust machine learning (ML) framework for accurately predicting the health index (HI) of MV XLPE cables. A multi-source dataset is developed, comprising 11, 15, and 20 kV XLPE cables with diverse aging and operational conditions. 30 ML models from 10 algorithmic families are benchmarked, with Bayesian Optimization (BO) chosen from six techniques utilized to determine optimal parameters for selected models. The Gradient Boosting classifier emerges as the top performer, achieving a Macro F1-score of 99.29% with minimal computational latency. More importantly, the proposed framework demonstrates strong cross-dataset generalization on the previously unseen 18 kV XLPE cable data with Macro F1-scores up to 94.98%, indicating its practical adaptability for real-world deployment. Robustness studies under label noise, missing feature conditions and class imbalance further validate the stability and resilience of the proposed approach, especially for severely degraded cable states. The framework demonstrates a macro-average AUC of 0.9996, indicating its effectiveness in prioritizing cables by degradation severity across various conditions. Compared to previous studies, the proposed framework offers a more scalable, user-friendly, and reliable solution for intelligent cable condition monitoring and predictive maintenance in future power systems.

  • Ultraviolet aging and electrical properties of the ZnO/HDPE/LDPE nanocomposites

    by Jing Chen, Chongjun Tian, Jinghui Gao, Lisheng Zhong

    To determine the influences of ultraviolet aging on the insulation materials of outdoor power cables and overhead insulated cables, the 0.1 wt% ZnO/HDPE/LDPE nanocomposites were prepared and the HDPE/LDPE blends were used as comparison. Both nanocomposites and blends were aged for 0 d, 2 d, 5 d, 10 d and 15 d under ultraviolet irradiation. The Fourier transform infrared spectra were tested, and electrical performances including volume conductivity, breakdown strength and space charge distribution were measured. Experimental results show that the ultraviolet aging causes greater increase in carbonyl groups in HDPE/LDPE blends than in ZnO/HDPE/LDPE nanocomposites. The latter shows superior resistance to ultraviolet aging than the former. After being aged for 15 d, the ZnO/HDPE/LDPE nanocomposites are 68% lower in conductivity, 25.2% higher in characteristic breakdown strength, and 19.9% smaller in average volume space charge density, in comparison with the HDPE/LDPE blends aged for 15 d. This work is beneficial for the development and application of environmentally friendly insulating materials for outdoor power cables and overhead insulated cables.

  • Structure–Property Relationship of Polypropylene‐Modified EPDM Composites for High‐Performance Cable Accessory Insulation

    by Hongchuan Zhu, Jing Xu, Zirui Huang, Yongbin Liu, Fei Li, Xueting Gao, He Li, Lisheng Zhong, Ming Wu, Jinghui Gao

    Cable accessories are weak points in high‐voltage systems, imposing stringent requirements on insulation materials. In this work, EPDM was modified with polypropylene (PP) of different molecular structures and contents to clarify structure–property relationships. Among random‐copolymer PP (R‐PP), block‐copolymer PP (B‐PP), and homopolymer PP (H‐PP) compared at the same content, H‐PP exhibited the highest crystallinity and showed superior electrical performance, particularly at elevated temperatures. Meanwhile, H‐PP also enhanced tensile strength, elastic modulus, and thermal conductivity while retaining a high elongation at break. Increasing the H‐PP content from 0 to 15 wt% further increased the crystallinity from approximately 0.3% to 6.1%, with only minor changes in crosslinking density. As a result, the AC breakdown strength, volume resistivity, tensile strength, and thermal conductivity were progressively improved, while the relative permittivity and dielectric loss remained comparatively stable. However, high H‐PP contents markedly increased the elastic modulus and reduced the elongation at break, revealing a trade‐off between reinforcement and mechanical compliance. Among the investigated formulations, 5 wt% H‐PP provided the most balanced combination of electrical performance, mechanical strength, and deformability. These results demonstrate that optimizing PP structure and content provides an effective approach for improving the comprehensive properties of EPDM for cable accessory insulation.

  • Open Access

    Non-monotonic Effect of Residual Vinyl on Thermo-Oxidative Aging Lifetime of High-Efficiency Crosslinked Polyethylene

    by Rui Sui, Haijing Zhao, Zhuxin Ma, Lin Cheng, Lisheng Zhong

    Controlling residual crosslinking byproducts in crosslinked polyethylene (XLPE) insulation is critical for the development of higher-voltage HVDC cables. High‐efficiency crosslinked polyethylene (HE‐XLPE) achieves high crosslinking degree with less DCP, but the incorporated liquid polybutadiene (LPB) introduces residual vinyl groups whose effect on thermo‐oxidative aging resistance is unclear. In this study, the effects of residual vinyl groups on the shortterm (210-220 °C) and longterm (135 °C) thermooxidative aging behavior of HEXLPE are investigated. Results indicate that residual vinyl groups participate in radical reactions even during the physical aging stage, accelerating oxidation, and such acceleration is more pronounced at lower temperatures, owing to the lower activation energies of the involved radical pathways. At experimental temperatures, the aging lifespan first increases and then decreases with increasing LPB, peaking at 1.5 phr. This non‐monotonic aging behavior can be contributed to the competition between vinyl‐induced acceleration and the inhibition from residual antioxidants (negatively correlated with DCP content). Considering aging resistance and byproduct reduction, LPB addition above 1.5 phr is not recommended. At this optimal dosage, DCP usage and total byproducts decrease by up to 25% and 30%, while aging resistance remains excellent. This study reveals the non‐monotonic regulation mechanism, providing a theoretical foundation for designing reliable HE-XLPE insulation.

  • Multiparameter Detection Technology for Temperature and Partial Discharge in Liquid–Solid Composite Dielectrics Based on DFB-FL

    by Jixian Qiao, Chao Du, Weichao Zhang, Lisheng Zhong, Qibing Shao, Hong Zhao

    Traditional fiber optic sensors used for operation and maintenance inspection of power equipment face challenges in achieving multi-parameter detection due to factors such as sensitivity, safety, detection range, reusability, and difficulty in spatial separation from the demodulation system. Distributed feedback fiber laser (DFB-FL) exhibit extremely high detection sensitivity to strain due to its ultra-narrow emission linewidth. Moreover, its small size, high safety, excellent reusability, and independent demodulation systems can effectively solve the aforementioned problems. Based on the ultimate frequency noise and acoustic pressure model, the minimum measurable acoustic pressure of DFB-FL in the partial discharge (PD) acoustic emission frequency band is derived. The relationship between the center wavelength of DFB-FL and external temperature changes is explored based on the temperature sensitivity characteristics of DFB-FL. A multi-parameter detection system for PD acoustic emission and temperature based on DFB-FL is developed. The results of 80 kVA oil-immersed transformer temperature and PD detection show that the developed DFB-FL multi-parameter detection system can be effectively applied to measure the top oil temperature and hot spot temperature of oil-immersed transformers. Meanwhile, under the same PD ultrasonic excitation source, the average maximum response SNR of the system is 13.71 dB higher than that of a piezoelectric transducer.

  • Open Access

    Experiments and Simulations on the Equivalence of Pre‐Cross‐Linking in Cable Insulation Material Extrusion

    by Zhuxin Ma, Kun Wang, Peng Cheng, Tianpeng Yang, Weikang Li, Bo Qiao, Wei Yang, Ming Wu, Lisheng Zhong

    The rheological properties of cable insulation materials are critical to the long‐term continuous extrusion performance of high‐voltage cables, with the pre‐cross‐linking effect playing a key role in determining the rheological behaviour of the insulation material during extrusion. Considering the pre‐cross‐linking effect, this study investigates the influence of molecular structure on the extrusion temperature, viscosity and shear rate distribution of insulation materials through equivalence experiments and simulations. The results indicate that the maximum temperature of 143°C occurs at the extrusion die land, where pressure and shear rate are highest. Furthermore, based on the optimised simulation model with experimental results, an empirical formula was established for predicting the maximum extrusion temperature of different insulation materials. This study reveals that although an increased terminal double‐bond content in low‐density polyethylene (LDPE) enhances the reactivity of insulation materials and reduces their shelf life, it also allows for a reduction in cross‐linking agent content, thereby mitigating pre‐cross‐linking. Insulation materials with a higher long‐chain branching degree and terminal double‐bond content in LDPE, combined with a lower cross‐linking agent content, are less susceptible to pre‐cross‐linking, which are more suitable for long‐length submarine cables, whereas the reduced by‐products also benefit the manufacture of DC cables; high‐speed shear promotes the diffusion of the cross‐linking agent dicumyl peroxide and enhances its interaction with the polyethylene chains. This research elucidates the influence of pre‐cross‐linking on the extrusion performance of insulation materials and develops an insulation material formulation more suitable for long‐duration extrusion.

  • Open Access

    Implantable ultrasonic sensor for partial discharge monitoring in large generator stator windings

    by Yiming Zhao, Yunfei Zhang, Yankai Cui, Zongqiang Ren, Hongxin Gong, Lisheng Zhong, Ming Wu, Xiaojie Lou, Jinghui Gao

    Corona discharge at the end of stator windings in large hydro-generators can lead to severe insulation degradation, threatening operational reliability. Accurate detection of such discharge is thus critical. Ultrasonic detection, known for its strong immunity to electromagnetic interference, is a promising technique. However, conventional sensors mounted on the generator casing suffer from significant signal attenuation and reflection due to spatial limitations, resulting in reduced sensitivity and accuracy. In this work, a structural component—namely the stator notch block—is modified to function as an implantable ultrasonic sensor without compromising its mechanical support role. The sensor utilizes PZT-5A piezoelectric ceramic and exhibits a peak sensitivity of 64 dB in the 30–650 kHz range. Experimental tests on a full-scale stator bar prototype confirm that the sensor can reliably detect corona discharge signals, with dominant frequency components below 150 kHz. These results establish a viable approach for improving the sensitivity and accuracy of partial discharge monitoring in large hydro-generators.