Robert Poel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Robert Poel has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
Mauricio Reyes
ARTORG Center for Biomedical Research, University of Bern, Bern, Switzerland
2 shared publicationsPeter Manser
Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, SWITZERLAND
2 shared publicationsAntony John Lomax
Department of Radiation Medicine, Paul Scherrer Institute, CH-5232 Villigen PSI, Villigen, SWITZERLAND
1 shared publicationArmando Gisep
Icotec ag, Altstätten, Sankt Gallen, SWITZERLAND
1 shared publicationChristina Schröder
Department of Radiation Oncology, Cantonal Hospital Winterthur, Winterthur, Switzerland
1 shared publicationChristoph Oehler
Department of Radiation Oncology, Cantonal Hospital Winterthur, Winterthur, Switzerland
1 shared publication
Latest Publications
- Open Access
- 26 November 2025
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 214, 111308
Evaluation of compartmentalized automatic segmentation for definition of the GTV in glioblastoma radiotherapy
- 26 November 2025
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 214, 111308
Open AccessEvaluation of compartmentalized automatic segmentation for definition of the GTV in glioblastoma radiotherapy
- Open Access
- 31 July 2025
- Published by Springer Nature in Communications Medicine
- Vol. 5 (1) , 1-11
A comprehensive multifaceted technical evaluation framework for implementation of auto-segmentation models in radiotherapy
Background Manual contouring of organs at risk in radiotherapy is time-consuming, taking 1-4 hours per case. Automatic segmentation using deep learning has emerged as a promising solution, with many commercial options now available. However, these methods require rigorous validation before clinical use, and current evaluation approaches lack consistency and comprehensive assessment across publications. Methods We developed the Comprehensive Multifaceted Technical Evaluation framework, which integrates four key assessment components: quantitative geometric measures, qualitative expert evaluation, time efficiency analysis, and dosimetric evaluation. We demonstrated this framework using an in-house automatic segmentation model for brain organs at risk, trained on 100 cases and evaluated by 8 radiation oncology experts from 4 institutions. The evaluation included geometric accuracy measurements, expert ratings of clinical acceptability, time-saving assessments, and dosimetric impact analysis comparing treatment plans. Results Here we show that our automatic segmentation model achieved an overall geometric accuracy of 0.78 and outperformed manual inter-rater variability. Expert evaluation revealed that 88% of automatically segmented structures were clinically acceptable with only minor adjustments needed. The evaluation and adjustment process averaged 22 minutes compared to 69 minutes for manual contouring. Dosimetric analysis showed minimal impact on treatment plans, with average dose differences of 0.30 Gray for mean dose and 0.23 Gray for maximum dose. Conclusions The framework provides a robust method for validating automatic segmentation models in radiotherapy. However, establishing standardized benchmarks and consensus guidelines within the radiotherapy community remains essential for proper clinical implementation and comparison of different segmentation tools.
- 31 July 2025
- Published by Springer Nature in Communications Medicine
- Vol. 5 (1) , 1-11
Open AccessA comprehensive multifaceted technical evaluation framework for implementation of auto-segmentation models in radiotherapy
Background Manual contouring of organs at risk in radiotherapy is time-consuming, taking 1-4 hours per case. Automatic segmentation using deep learning has emerged as a promising solution, with many commercial options now available. However, these methods require rigorous validation before clinical use, and current evaluation approaches lack consistency and comprehensive assessment across publications. Methods We developed the Comprehensive Multifaceted Technical Evaluation framework, which integrates four key assessment components: quantitative geometric measures, qualitative expert evaluation, time efficiency analysis, and dosimetric evaluation. We demonstrated this framework using an in-house automatic segmentation model for brain organs at risk, trained on 100 cases and evaluated by 8 radiation oncology experts from 4 institutions. The evaluation included geometric accuracy measurements, expert ratings of clinical acceptability, time-saving assessments, and dosimetric impact analysis comparing treatment plans. Results Here we show that our automatic segmentation model achieved an overall geometric accuracy of 0.78 and outperformed manual inter-rater variability. Expert evaluation revealed that 88% of automatically segmented structures were clinically acceptable with only minor adjustments needed. The evaluation and adjustment process averaged 22 minutes compared to 69 minutes for manual contouring. Dosimetric analysis showed minimal impact on treatment plans, with average dose differences of 0.30 Gray for mean dose and 0.23 Gray for maximum dose. Conclusions The framework provides a robust method for validating automatic segmentation models in radiotherapy. However, establishing standardized benchmarks and consensus guidelines within the radiotherapy community remains essential for proper clinical implementation and comparison of different segmentation tools.
- 10 December 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (24) , 245031
Assessing the advantages of CFR-PEEK over titanium spinal stabilization implants in proton therapy—a phantom study
High-density materials, such as titanium, used for spinal stabilization, introduces several critical issues in proton therapy (PT). Artefacts affect both contouring and dose calculation. Subsequently, artefacts need to be corrected which is a time-consuming process. Besides, titanium causes proton interactions that are unaccounted for in dose calculation. The result is a suboptimal treatment plan, and indeed decreased local controls have been reported for these patients. Carbon fiber reinforced polyetheretherketone (CFR-PEEK) implant material, which is of low density, potentially solves these issues. For this study, we designed a unique phantom to compare the effects of titanium and CFR-PEEK implants in PT. The phantom contains four interchangeable spinal inserts representing a native spine, and three different spinal stabilizations consisting of titanium only, CFR-PEEK only, and a combination of titanium and CFR-PEEK. All phantom scenarios received the standard treatment workup. Two planning approaches were investigated: a single field plan and a multi-field optimized plan with spinal cord sparing. For both plans we analyzed the following aspects: total volume of artefacts on CT images, time required for artefact correction, effect of planning CT correction on dose calculation, plan robustness to range and set up uncertainties, and finally the discrepancy between the calculated dose and the delivered dose with Gafchromic® film. The CFR-PEEK implant had a 90% reduction of artefacts on CT images and subsequently severely reduced the time for artefact correction with respect to the titanium-only implant. Furthermore, the CFR-PEEK as opposed to titanium did not influence the robustness of the plan. Finally, the titanium implants led to hardware-related discrepancies between the planned and the measured dose while the CFR-PEEK implant showed good agreement. As opposed to titanium, CFR-PEEK has none to minor effects on PT. The use of CFR-PEEK is expected to optimize treatment and possibly improve outcomes for patients that require spinal stabilization.
- 10 December 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (24) , 245031
Assessing the advantages of CFR-PEEK over titanium spinal stabilization implants in proton therapy—a phantom study
High-density materials, such as titanium, used for spinal stabilization, introduces several critical issues in proton therapy (PT). Artefacts affect both contouring and dose calculation. Subsequently, artefacts need to be corrected which is a time-consuming process. Besides, titanium causes proton interactions that are unaccounted for in dose calculation. The result is a suboptimal treatment plan, and indeed decreased local controls have been reported for these patients. Carbon fiber reinforced polyetheretherketone (CFR-PEEK) implant material, which is of low density, potentially solves these issues. For this study, we designed a unique phantom to compare the effects of titanium and CFR-PEEK implants in PT. The phantom contains four interchangeable spinal inserts representing a native spine, and three different spinal stabilizations consisting of titanium only, CFR-PEEK only, and a combination of titanium and CFR-PEEK. All phantom scenarios received the standard treatment workup. Two planning approaches were investigated: a single field plan and a multi-field optimized plan with spinal cord sparing. For both plans we analyzed the following aspects: total volume of artefacts on CT images, time required for artefact correction, effect of planning CT correction on dose calculation, plan robustness to range and set up uncertainties, and finally the discrepancy between the calculated dose and the delivered dose with Gafchromic® film. The CFR-PEEK implant had a 90% reduction of artefacts on CT images and subsequently severely reduced the time for artefact correction with respect to the titanium-only implant. Furthermore, the CFR-PEEK as opposed to titanium did not influence the robustness of the plan. Finally, the titanium implants led to hardware-related discrepancies between the planned and the measured dose while the CFR-PEEK implant showed good agreement. As opposed to titanium, CFR-PEEK has none to minor effects on PT. The use of CFR-PEEK is expected to optimize treatment and possibly improve outcomes for patients that require spinal stabilization.