Sheik Mohammad Mohiuddin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sheik Mohammad Mohiuddin has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Wei Du
Pacific Northwest National Laboratory, Richland, WA, USA
5 shared publications - Junjian Qi
McComish Department of Electrical Engineering and Computer Science, South Dakota State University, Brookings, SD 57007, USA
4 shared publications - Xue Lyu
Pacific Northwest National Laboratory, Richland, WA, USA
4 shared publications - Jun Zhang
McComish Department of Electrical Engineering and Computer Science, South Dakota State University, Brookings, SD, USA
2 shared publications - Quan Nguyen
Pacific Northwest National Laboratory, Richland, WA, USA
2 shared publications A.M.O Haruni
School of Engineering and Information Technology, The University of New South Wales Canberra, ACT 2610, Australia
1 shared publication
Latest Publications
- Top Cited PapersOpen Access
- 23 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 29250-29259
Using Grid-Forming Energy Storage Systems to Provide Dynamic Active Power Support for Hyperscale Data Center
Large artificial intelligence (AI) training data centers are emerging as significant, highly dynamic digital loads that pose numerous challenges to power system stability. Methods to study and assess their impact are still being developed and have been the focus of numerous industry interest groups. Intended to contribute to bridging this gap, this paper develops a credible impact study for data centers, presenting a dynamic data‑center model that includes an uninterruptible power supply (UPS), co‑generator, cooling system, and a grid-forming (GFM) controlled energy storage system (ESS), with explicit converter and control dynamics. Using electromagnetic transient simulations, two stress scenarios are studied: low‑voltage faults and fast load fluctuations characteristic of AI training. The results show that an adequately tuned and controlled GFM ESS can significantly improve the large load response by reducing frequency overshoot, raising the nadir, shortening settling time, and enhancing post‑fault recovery. Under fast fluctuation AI training load profiles, the ESS also damps active‑power oscillations and reduces torsional shaft‑torque oscillations in the generator train to safe levels. These findings support ESS‑based control as an effective tool for integrating large AI data centers without compromising grid stability.
- 23 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 29250-29259
Top Cited PapersOpen AccessUsing Grid-Forming Energy Storage Systems to Provide Dynamic Active Power Support for Hyperscale Data Center
Large artificial intelligence (AI) training data centers are emerging as significant, highly dynamic digital loads that pose numerous challenges to power system stability. Methods to study and assess their impact are still being developed and have been the focus of numerous industry interest groups. Intended to contribute to bridging this gap, this paper develops a credible impact study for data centers, presenting a dynamic data‑center model that includes an uninterruptible power supply (UPS), co‑generator, cooling system, and a grid-forming (GFM) controlled energy storage system (ESS), with explicit converter and control dynamics. Using electromagnetic transient simulations, two stress scenarios are studied: low‑voltage faults and fast load fluctuations characteristic of AI training. The results show that an adequately tuned and controlled GFM ESS can significantly improve the large load response by reducing frequency overshoot, raising the nadir, shortening settling time, and enhancing post‑fault recovery. Under fast fluctuation AI training load profiles, the ESS also damps active‑power oscillations and reduces torsional shaft‑torque oscillations in the generator train to safe levels. These findings support ESS‑based control as an effective tool for integrating large AI data centers without compromising grid stability.
- 3 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automation Science and Engineering
- Vol. 23 (15455955) , 4833-4847
Distributed Optimal Control for Grid-Forming and Grid-Feeding Converters in DC Microgrid
This paper proposes a distributed optimal control for grid-forming (GFM) and grid-feeding (GFE) converters in an islanded direct current (DC) microgrid. An optimization problem is first formulated: 1) The GFM converters’ voltages and GFE converters’ currents are taken as the control variables; 2) The trade-off between voltage regulation and current sharing is selected as the objective; and 3) The converters’ technical constraints on voltage limits and current capacities are considered. Then, to solve the formulated optimization problem, a distributed primal-dual gradient-based algorithm is developed to estimate the global average voltage, gradients, and inequality constraint function values. Proof of the optimality and stability of the proposed algorithm is provided. Finally, simulation results on a DC microgrid with eight distributed generators using OPAL-RT real-time simulator validate the proposed control’s convergence, optimality, advantages over an existing method, and robustness to non-ideal communication network, measurement uncertainties, and nonlinear load conditions.
- 3 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automation Science and Engineering
- Vol. 23 (15455955) , 4833-4847
Distributed Optimal Control for Grid-Forming and Grid-Feeding Converters in DC Microgrid
This paper proposes a distributed optimal control for grid-forming (GFM) and grid-feeding (GFE) converters in an islanded direct current (DC) microgrid. An optimization problem is first formulated: 1) The GFM converters’ voltages and GFE converters’ currents are taken as the control variables; 2) The trade-off between voltage regulation and current sharing is selected as the objective; and 3) The converters’ technical constraints on voltage limits and current capacities are considered. Then, to solve the formulated optimization problem, a distributed primal-dual gradient-based algorithm is developed to estimate the global average voltage, gradients, and inequality constraint function values. Proof of the optimality and stability of the proposed algorithm is provided. Finally, simulation results on a DC microgrid with eight distributed generators using OPAL-RT real-time simulator validate the proposed control’s convergence, optimality, advantages over an existing method, and robustness to non-ideal communication network, measurement uncertainties, and nonlinear load conditions.
- 21 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (4) , 6472-6483
A Two-Stage Current Limiting Control Strategy for Direct-Droop-Controlled Grid-Forming Inverters
This paper presents a two-stage current limiting control strategy with fault ride-through capability for direct-droop-controlled grid-forming (GFM) inverters. The proposed two-stage approach comprises two current limiting controls in Stages 1 and 2. During faults, the Stage 1 current limiting control instantly clamps the inverter output current magnitude to its maximum transient limit by blocking the switching pulses to the insulated-gate bipolar transistors (IGBTs) with the help of a hysteresis loop control. The Stage 2 current limiting control limits the inverter output current magnitude to its steady-state limit by regulating the amplitude and angular frequency of the modulating waveform utilizing the active and reactive current limiting control loops. By implementing the current limiting actions in two stages, this approach can effectively limit the over-current within a few PWM cycles after the fault occurrence and ensure synchronism to the grid after long-term fault events. The efficacy of the proposed control approach is validated through results obtained from electromagnetic transient (EMT) simulation conducted on a single GFM inverter-based test system and the IEEE 39- bus test system with multiple GFM inverters in the PSCAD platform.
- 21 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (4) , 6472-6483
A Two-Stage Current Limiting Control Strategy for Direct-Droop-Controlled Grid-Forming Inverters
This paper presents a two-stage current limiting control strategy with fault ride-through capability for direct-droop-controlled grid-forming (GFM) inverters. The proposed two-stage approach comprises two current limiting controls in Stages 1 and 2. During faults, the Stage 1 current limiting control instantly clamps the inverter output current magnitude to its maximum transient limit by blocking the switching pulses to the insulated-gate bipolar transistors (IGBTs) with the help of a hysteresis loop control. The Stage 2 current limiting control limits the inverter output current magnitude to its steady-state limit by regulating the amplitude and angular frequency of the modulating waveform utilizing the active and reactive current limiting control loops. By implementing the current limiting actions in two stages, this approach can effectively limit the over-current within a few PWM cycles after the fault occurrence and ensure synchronism to the grid after long-term fault events. The efficacy of the proposed control approach is validated through results obtained from electromagnetic transient (EMT) simulation conducted on a single GFM inverter-based test system and the IEEE 39- bus test system with multiple GFM inverters in the PSCAD platform.
- Open Access
- 20 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 15825-15839
Virtual Agents-Based Attack-Resilient Distributed Control for Islanded AC Microgrid
Due to its dependence on a communication network, distributed secondary control of microgrids is susceptible to denial-of-service (DoS) attacks in channel shutdown mode, which may negatively impact the network connectivity and thus deteriorate the coordination and power sharing among distributed generators (DGs). Honeypot is a common method for cyber deception by introducing fake targets. However, in the context of microgrid, the misleading information spread by honeypots will also impact the system performance. This paper proposes an attack-resilient distributed control for AC microgrids utilizing virtual agents (VAs) to counteract both DoS edge and node attacks. The VAs are designed to not impact the system’s steady state during normal operation but to share information among neighboring real agents and serve as dummy targets for DoS attacks. The control with VAs is implemented by a primal-dual gradient-based distributed algorithm to efficiently obtain a practical solution for voltage/frequency regulation and power sharing. The simulation results on a 4-DG test system and a modified IEEE 34-bus system show that 1) VAs do not impact the normal functionality of the test system, and 2) deploying VAs can enhance the resilience of the microgrid control against DoS edge and node attacks.
- 20 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 15825-15839
Open AccessVirtual Agents-Based Attack-Resilient Distributed Control for Islanded AC Microgrid
Due to its dependence on a communication network, distributed secondary control of microgrids is susceptible to denial-of-service (DoS) attacks in channel shutdown mode, which may negatively impact the network connectivity and thus deteriorate the coordination and power sharing among distributed generators (DGs). Honeypot is a common method for cyber deception by introducing fake targets. However, in the context of microgrid, the misleading information spread by honeypots will also impact the system performance. This paper proposes an attack-resilient distributed control for AC microgrids utilizing virtual agents (VAs) to counteract both DoS edge and node attacks. The VAs are designed to not impact the system’s steady state during normal operation but to share information among neighboring real agents and serve as dummy targets for DoS attacks. The control with VAs is implemented by a primal-dual gradient-based distributed algorithm to efficiently obtain a practical solution for voltage/frequency regulation and power sharing. The simulation results on a 4-DG test system and a modified IEEE 34-bus system show that 1) VAs do not impact the normal functionality of the test system, and 2) deploying VAs can enhance the resilience of the microgrid control against DoS edge and node attacks.
- Top Cited Papers
- 9 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 40 (2) , 1997-2000
Critical Clearing Time for Droop-Controlled Grid-Forming Inverters With Circular Current Limiting and Virtual Impedance Current Limiting
The critical clearing time is a crucial parameter for assessing the large-signal stability of grid-forming (GFM) inverters. Variations in current limiters can significantly impact an inverter's transient behavior during large disturbances. This letter introduces a method based on the power-angle relationship to evaluate the fault recovery of a droop-controlled GFM inverter under a three-phase bolted fault scenario, considering both the circular current limiter and the virtual impedance method. High-fidelity simulations validate the accuracy of the proposed formulas in estimating the critical clearing time of the GFM inverter
- 9 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 40 (2) , 1997-2000
Top Cited PapersCritical Clearing Time for Droop-Controlled Grid-Forming Inverters With Circular Current Limiting and Virtual Impedance Current Limiting
The critical clearing time is a crucial parameter for assessing the large-signal stability of grid-forming (GFM) inverters. Variations in current limiters can significantly impact an inverter's transient behavior during large disturbances. This letter introduces a method based on the power-angle relationship to evaluate the fault recovery of a droop-controlled GFM inverter under a three-phase bolted fault scenario, considering both the circular current limiter and the virtual impedance method. High-fidelity simulations validate the accuracy of the proposed formulas in estimating the critical clearing time of the GFM inverter
- 24 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 16 (2) , 1897-1910
Resilient Control of Networked Microgrids Using Vertical Federated Reinforcement Learning: Designs and Real-Time Test-Bed Validations
Improving system-level resiliency of networked microgrids against adversarial cyber-attacks is an important aspect in the current regime of increased inverter-based resources (IBRs). To achieve that, this paper contributes in designing a hierarchical control layer, in conjunction with the existing control layers, resilient to adversarial attack signals. Considering model complexities, unknown dynamical behaviors of IBRs, and privacy issues regarding data sharing in multi-party-owned microgrids, designing such a control layer is non-trivial. Here, to tackle these issues, a novel federated reinforcement learning (Fed-RL) method is proposed. To grasp the interconnected dynamics of networked microgrids, the paper develops Federated Soft Actor-Critic (FedSAC) algorithm following the vertical structure of implementing Fed-RL. Next, utilizing the OpenAI Gym interface, we built a custom set-up in GridLAB-D/HELICS co-simulation platform, named Resilient RL Co-simulation (ResRLCoSIM), to train the RL agents with IEEE 123-bus benchmark comprising 3 interconnected microgrids. Finally, the learned policies in the simulation are transferred to the real-time hardware-in-the-loop (HIL) test-bed developed using the high-fidelity Hypersim platform. Experiments show that the simulator-trained RL controllers achieve desirable performance with the test-bed platform, validating the minimization of the sim-to-real gap.
- 24 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 16 (2) , 1897-1910
Resilient Control of Networked Microgrids Using Vertical Federated Reinforcement Learning: Designs and Real-Time Test-Bed Validations
Improving system-level resiliency of networked microgrids against adversarial cyber-attacks is an important aspect in the current regime of increased inverter-based resources (IBRs). To achieve that, this paper contributes in designing a hierarchical control layer, in conjunction with the existing control layers, resilient to adversarial attack signals. Considering model complexities, unknown dynamical behaviors of IBRs, and privacy issues regarding data sharing in multi-party-owned microgrids, designing such a control layer is non-trivial. Here, to tackle these issues, a novel federated reinforcement learning (Fed-RL) method is proposed. To grasp the interconnected dynamics of networked microgrids, the paper develops Federated Soft Actor-Critic (FedSAC) algorithm following the vertical structure of implementing Fed-RL. Next, utilizing the OpenAI Gym interface, we built a custom set-up in GridLAB-D/HELICS co-simulation platform, named Resilient RL Co-simulation (ResRLCoSIM), to train the RL agents with IEEE 123-bus benchmark comprising 3 interconnected microgrids. Finally, the learned policies in the simulation are transferred to the real-time hardware-in-the-loop (HIL) test-bed developed using the high-fidelity Hypersim platform. Experiments show that the simulator-trained RL controllers achieve desirable performance with the test-bed platform, validating the minimization of the sim-to-real gap.
- 16 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 39 (4) , 6107-6110
Criteria for Grid-Forming Inverters Transitioning Between Current Limiting Mode and Normal Operation
This letter focuses on the fault recovery analysis of inverters using multi-loop droop based grid-forming control, taking into account different current limiting strategies. A criterion is proposed to determine when the inverter can exit the current limiting mode after fault clearance. The theoretical findings are verified through electromagnetic transient simulations using the direct ( $d$ )-axis priority-based current limiting method, circular current limiting method, and virtual impedance method.
- 16 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 39 (4) , 6107-6110
Criteria for Grid-Forming Inverters Transitioning Between Current Limiting Mode and Normal Operation
This letter focuses on the fault recovery analysis of inverters using multi-loop droop based grid-forming control, taking into account different current limiting strategies. A criterion is proposed to determine when the inverter can exit the current limiting mode after fault clearance. The theoretical findings are verified through electromagnetic transient simulations using the direct ( $d$ )-axis priority-based current limiting method, circular current limiting method, and virtual impedance method.
- 9 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
A Current Limiting Control Strategy for Single-Loop Droop-Controlled Grid-Forming Inverters Under Balanced and Unbalanced Faults
Existing studies reporting current limiting control strategies for grid-forming inverters primarily focus on grid-forming inverters that use a multi-loop control structure. This study reports a current limiting control for grid-forming inverters that uses a single-loop control structure. The proposed current limiting control was implemented at the pulse width modulation (PWM) control layer to guarantee a rapid response. Once an overcurrent caused by severe faults is detected, the proposed control strategy immediately blocks relevant insulated-gate bipolar transistors (IGBTs) using a hysteresis loop, ensuring that the overcurrent is limited within a few PWM cycles. After the fault is cleared, the inverter seamlessly transfers back to droop control mode to maintain stability. The current limiting control has been tested in a microgrid environment operating in the OPAL-RT platform. Study results show that the control strategy can effectively limit the overcurrent under both balanced and unbalanced faults and can maintain system transient stability after the fault is cleared.
- 9 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
A Current Limiting Control Strategy for Single-Loop Droop-Controlled Grid-Forming Inverters Under Balanced and Unbalanced Faults
Existing studies reporting current limiting control strategies for grid-forming inverters primarily focus on grid-forming inverters that use a multi-loop control structure. This study reports a current limiting control for grid-forming inverters that uses a single-loop control structure. The proposed current limiting control was implemented at the pulse width modulation (PWM) control layer to guarantee a rapid response. Once an overcurrent caused by severe faults is detected, the proposed control strategy immediately blocks relevant insulated-gate bipolar transistors (IGBTs) using a hysteresis loop, ensuring that the overcurrent is limited within a few PWM cycles. After the fault is cleared, the inverter seamlessly transfers back to droop control mode to maintain stability. The current limiting control has been tested in a microgrid environment operating in the OPAL-RT platform. Study results show that the control strategy can effectively limit the overcurrent under both balanced and unbalanced faults and can maintain system transient stability after the fault is cleared.
- 18 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Droop-Free Distributed Control of DC Microgrids with Voltage Profile Guarantees and Relaxed Current Sharing
This paper presents a droop-free distributed secondary control for DC microgrids with admissible voltage profile guarantees. The control objectives are achieved through an average voltage regulator, voltage variance regulator, and a relaxed current sharing regulator. Regulations of the global average voltage to the microgrid rated voltage is ensured by the average voltage regulator and regulations of the global voltage variance to a predetermined reference is enabled by the voltage variance regulator. In order to achieve the objectives of voltage regulation, the current sharing from one of the DGs which may be owned by the microgrid community is relaxed. The global dynamic model of the DC microgrid with the proposed control is derived. Besides, steady-state analysis is performed to show that all objectives can be achieved. Finally, simulations on a 4-DG DC microgrid test system are performed to validate the efficacy of the proposed control.
- 18 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Droop-Free Distributed Control of DC Microgrids with Voltage Profile Guarantees and Relaxed Current Sharing
This paper presents a droop-free distributed secondary control for DC microgrids with admissible voltage profile guarantees. The control objectives are achieved through an average voltage regulator, voltage variance regulator, and a relaxed current sharing regulator. Regulations of the global average voltage to the microgrid rated voltage is ensured by the average voltage regulator and regulations of the global voltage variance to a predetermined reference is enabled by the voltage variance regulator. In order to achieve the objectives of voltage regulation, the current sharing from one of the DGs which may be owned by the microgrid community is relaxed. The global dynamic model of the DC microgrid with the proposed control is derived. Besides, steady-state analysis is performed to show that all objectives can be achieved. Finally, simulations on a 4-DG DC microgrid test system are performed to validate the efficacy of the proposed control.
- 4 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 11 (3) , 1956-1967
Droop-Free Distributed Control for AC Microgrids With Precisely Regulated Voltage Variance and Admissible Voltage Profile Guarantees
In this paper, we propose a droop-free distributed cooperative control with precisely regulated voltage variance and admissible voltage profile guarantees for AC microgrids. First a distributed voltage variance observer is proposed and proven to be able to converge to global voltage variance using only local measurements and information from neighboring distributed generators (DGs). A droop-free distributed control with average voltage regulator, voltage variance regulator, and relaxed reactive power regulator is then designed and shown to be able to achieve the regulation of average voltage and voltage variance and relaxed reactive power sharing in steady-state. For relaxed reactive power sharing, one special DG that could be a community-owned or utility-owned DG will not participate in reactive power sharing and this flexibility is utilized to regulate the voltage profile. The small-signal stability of the system with the proposed control is evaluated by measurement-based Prony analysis, which can also guide the control parameter selection. It is also shown that the steady-state solution of the proposed control can be obtained by solving a set of nonlinear equations, which allows more efficient evaluation of the control performance under different operating conditions and various controller settings. To validate the performance of the proposed control, extensive real-time simulation studies are performed in OPAL-RT on a four-DG test microgrid.
- 4 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 11 (3) , 1956-1967
Droop-Free Distributed Control for AC Microgrids With Precisely Regulated Voltage Variance and Admissible Voltage Profile Guarantees
In this paper, we propose a droop-free distributed cooperative control with precisely regulated voltage variance and admissible voltage profile guarantees for AC microgrids. First a distributed voltage variance observer is proposed and proven to be able to converge to global voltage variance using only local measurements and information from neighboring distributed generators (DGs). A droop-free distributed control with average voltage regulator, voltage variance regulator, and relaxed reactive power regulator is then designed and shown to be able to achieve the regulation of average voltage and voltage variance and relaxed reactive power sharing in steady-state. For relaxed reactive power sharing, one special DG that could be a community-owned or utility-owned DG will not participate in reactive power sharing and this flexibility is utilized to regulate the voltage profile. The small-signal stability of the system with the proposed control is evaluated by measurement-based Prony analysis, which can also guide the control parameter selection. It is also shown that the steady-state solution of the proposed control can be obtained by solving a set of nonlinear equations, which allows more efficient evaluation of the control performance under different operating conditions and various controller settings. To validate the performance of the proposed control, extensive real-time simulation studies are performed in OPAL-RT on a four-DG test microgrid.