M. Saravanabalaji
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
M. Saravanabalaji has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
N. Sivakumaran
Department of Electronics and instrumentation Engineering, Kumaraguru college of Technology, Coimbatore, India
2 shared publicationsV. Athappan
Department of Electronics and instrumentation Engineering, Kumaraguru college of Technology, Coimbatore, India
2 shared publicationsC. Mathan
Department of Electronics and instrumentation Engineering, Mahendra Engineering College, Coimbatore, India
1 shared publication- C. Mathan
Sri Ramakrishna Engineering College
1 shared publication D. Arun Nehru
Department of Electrical and Electronics Engineering, Indus college of Engineering, Coimbatore, India
1 shared publicationE. Muthuramalingam
Department of Electronics and instrumentation Engineering, Kumaraguru college of Technology Coimbatore, India
1 shared publication
Latest Publications
- 14 November 2026
- Published by IWA Publishing in Water Supply
Machine learning-based leak detection and predefined leak-location classification in water distribution systems using experimental pressure and vibration data
Leakage in water distribution systems can cause substantial water loss, infrastructure deterioration, and operational challenges, motivating data-driven detection and localization methods. This study investigates experimentally acquired pressure and vibration measurements from a laboratory water-distribution pipeline using a unified machine-learning framework. The approximately 6.0-m test loop used nominal 1-inch pipeline sections, a 1.3-kW, 2,700-rpm circulation pump, an inlet valve maintained at approximately 70% open, and an observed no-leak operating pressure of approximately 1 bar. Three artificial leakage locations used 8-mm openings. Three sensing configurations – pressure-only, vibration-only, and pressure–vibration fusion – were evaluated using Random Forest, XGBoost, LightGBM, and Multi-Layer Perceptron models with engineered time- and frequency-domain features. Binary leak detection and predefined single-leak-location classification were evaluated separately using fixed held-out test partitions. The majority-class baseline achieved 85.0% accuracy, demonstrating that accuracy alone can be misleading under class imbalance. Localization was substantially more challenging, with a maximum accuracy of 40.0% and macro-F1 of 38.89%. Statistical comparisons did not identify significant pairwise differences after correction. The study provides an offline experimental proof-of-concept requiring independent-run and field-scale validation.
- 14 November 2026
- Published by IWA Publishing in Water Supply
Machine learning-based leak detection and predefined leak-location classification in water distribution systems using experimental pressure and vibration data
Leakage in water distribution systems can cause substantial water loss, infrastructure deterioration, and operational challenges, motivating data-driven detection and localization methods. This study investigates experimentally acquired pressure and vibration measurements from a laboratory water-distribution pipeline using a unified machine-learning framework. The approximately 6.0-m test loop used nominal 1-inch pipeline sections, a 1.3-kW, 2,700-rpm circulation pump, an inlet valve maintained at approximately 70% open, and an observed no-leak operating pressure of approximately 1 bar. Three artificial leakage locations used 8-mm openings. Three sensing configurations – pressure-only, vibration-only, and pressure–vibration fusion – were evaluated using Random Forest, XGBoost, LightGBM, and Multi-Layer Perceptron models with engineered time- and frequency-domain features. Binary leak detection and predefined single-leak-location classification were evaluated separately using fixed held-out test partitions. The majority-class baseline achieved 85.0% accuracy, demonstrating that accuracy alone can be misleading under class imbalance. Localization was substantially more challenging, with a maximum accuracy of 40.0% and macro-F1 of 38.89%. Statistical comparisons did not identify significant pairwise differences after correction. The study provides an offline experimental proof-of-concept requiring independent-run and field-scale validation.
- 13 February 2025
- Published by Springer Nature
- p. 233-242
Smart Soil Nutrient Prediction System
- 12 February 2025
- Published by Springer Nature
- p. 963-973
Experimental Approach for Water Distribution Network to Compensate the Unequal Discharge Using Dual Pumping System
- 12 February 2025
- Published by Springer Nature
- p. 963-973
Experimental Approach for Water Distribution Network to Compensate the Unequal Discharge Using Dual Pumping System
- 1 August 2023
- Published by Taylor & Francis in Urban Water Journal
- Vol. 20 (9) , 1123-1139
Acoustic signal based water leakage detection system using hybrid machine learning model
- 1 August 2023
- Published by Taylor & Francis in Urban Water Journal
- Vol. 20 (9) , 1123-1139
Acoustic signal based water leakage detection system using hybrid machine learning model
- 24 April 2019
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series B
- Vol. 100 (5) , 405-415
Dynamic Compensation of Acoustic Resonance for Water Flow System
- 24 April 2019
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series B
- Vol. 100 (5) , 405-415
Dynamic Compensation of Acoustic Resonance for Water Flow System
- 21 December 2018
- Published by Springer Nature
- p. 834-844
Level Plant Automation Using Yokogawa DCS Centum-VP - A Case Study
- 21 December 2018
- Published by Springer Nature
- p. 834-844
Level Plant Automation Using Yokogawa DCS Centum-VP - A Case Study
- 1 November 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Online estimation of pulp mixing in paper industries
Paper industries are using manual chemical control methods to apply the chemicals to the digester. The main objective of the project is to increase the quality of the paper by increasing the brightness of the pulp. The brightness of the pulp is inversely proportional to the pH value. Hence, the pH value should be maintained in the range of (2-4) to achieve the maximum brightness range 85%. Initially, concentrated sulphuric acid is pumped from the filtrate to the stand pipe in which the pulp is present. This mixture is mixed with the bleaching agent (ClO2 solution) in a D0 mixer. The acidity is controlled by the brightness given by a device. The industries are facing difficulty in calculating the accurate amount of acid to be supplied. The brightness shows fluctuations and makes it more difficult. In order to solve this problem, we are introducing pH meter(to detect the acidity of the solution) parallelly to the mixer. Due to this, the wastage of the pulp and chemicals is reduced and the quality of the paper is increased.
- 1 November 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Online estimation of pulp mixing in paper industries
Paper industries are using manual chemical control methods to apply the chemicals to the digester. The main objective of the project is to increase the quality of the paper by increasing the brightness of the pulp. The brightness of the pulp is inversely proportional to the pH value. Hence, the pH value should be maintained in the range of (2-4) to achieve the maximum brightness range 85%. Initially, concentrated sulphuric acid is pumped from the filtrate to the stand pipe in which the pulp is present. This mixture is mixed with the bleaching agent (ClO2 solution) in a D0 mixer. The acidity is controlled by the brightness given by a device. The industries are facing difficulty in calculating the accurate amount of acid to be supplied. The brightness shows fluctuations and makes it more difficult. In order to solve this problem, we are introducing pH meter(to detect the acidity of the solution) parallelly to the mixer. Due to this, the wastage of the pulp and chemicals is reduced and the quality of the paper is increased.