Paras Savla
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Paras Savla has a total of 80 co-authors. Here are the top co-authors by number of shared publications:
- Dan Miulli
Arrowhead Reg Med Ctr, Dept Neurosurg, Colton, CA USA
19 shared publications - James Brazdzionis
Neurosurgery, Riverside University Health System Medical Center, Moreno Valley, USA
11 shared publications - Tye Patchana
Neurosurgery, Riverside University Health System Medical Center, Moreno Valley, USA
11 shared publications - James Wiginton
Neurosurgery, Riverside University Health System Medical Center, Moreno Valley, USA
10 shared publications - Saman Farr
Neurosurgery, Riverside University Health System Medical Center, Moreno Valley, USA
8 shared publications - Samir Kashyap
Mayo Clinic, Jacksonville, FL, USA
6 shared publications
Latest Publications
- Open Access
- 16 August 2024
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 15, 287
Symptomatic central nervous system tuberculosis and human herpesvirus-6 coinfection with associated hydrocephalus managed with endoscopic third ventriculostomy: A case report and review of human herpesvirus-6 neuropathology
Background: Human herpesvirus 6 (HHV-6) is a double-stranded DNA virus well established in the clinical literature to cause the near-universal childhood infection roseola infantum (exanthema subitum/sixth disease). Primary HHV-6 infection has been reported to cause meningoencephalitis in pediatric patients, although generally in the immunocompromised. Case Description: The authors treated an immunocompetent 18-month-old female who transferred to our institution for a higher level of care given concerns for meningitis in the setting of decreased level of arousal (Glasgow Coma Scale 12), and bradycardia 9 days after the onset of nasal congestion, fatigue, and repeated bouts of emesis. Outside hospital cerebrospinal fluid (CSF) studies were notable for hypoglycorrhachia, elevated protein, elevated nucleated cells with a mononuclear predominance, and a meningitis polymerase chain reaction panel that was positive only for HHV-6. Brain magnetic resonance imaging with and without contrast revealed a basal cistern predominant leptomeningeal enhancement pattern as well as moderate ventriculomegaly with associated periventricular edema concerning acute communicating hydrocephalus. Considering the CSF studies, neuroimaging, and recent travel history to Mexico, central nervous system (CNS) tuberculosis (TB) was the leading suspicion, and antimicrobial therapy was initiated for this presumptive diagnosis with culture data only proving the TB suspicion correct after nearly 2 months in culture. Anti-viral therapy was initially not felt to be necessary as the HHV-6 was interpreted as incidental and not a cause of symptomatic meningitis in our immunocompetent host. The patient’s hydrocephalus was treated with temporary CSF diversion followed by performance of an endoscopic third ventriculostomy. Despite appropriate hydrocephalus management, clinical improvement ultimately seemed to correlate with the initiation of antiviral therapy. Conclusion: The authors present this case and review the literature on HHV-6-associated CNS infections with the goal of informing the neurosurgeon about this often clinically underestimated pathogen.
- 16 August 2024
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 15, 287
Open AccessSymptomatic central nervous system tuberculosis and human herpesvirus-6 coinfection with associated hydrocephalus managed with endoscopic third ventriculostomy: A case report and review of human herpesvirus-6 neuropathology
Background: Human herpesvirus 6 (HHV-6) is a double-stranded DNA virus well established in the clinical literature to cause the near-universal childhood infection roseola infantum (exanthema subitum/sixth disease). Primary HHV-6 infection has been reported to cause meningoencephalitis in pediatric patients, although generally in the immunocompromised. Case Description: The authors treated an immunocompetent 18-month-old female who transferred to our institution for a higher level of care given concerns for meningitis in the setting of decreased level of arousal (Glasgow Coma Scale 12), and bradycardia 9 days after the onset of nasal congestion, fatigue, and repeated bouts of emesis. Outside hospital cerebrospinal fluid (CSF) studies were notable for hypoglycorrhachia, elevated protein, elevated nucleated cells with a mononuclear predominance, and a meningitis polymerase chain reaction panel that was positive only for HHV-6. Brain magnetic resonance imaging with and without contrast revealed a basal cistern predominant leptomeningeal enhancement pattern as well as moderate ventriculomegaly with associated periventricular edema concerning acute communicating hydrocephalus. Considering the CSF studies, neuroimaging, and recent travel history to Mexico, central nervous system (CNS) tuberculosis (TB) was the leading suspicion, and antimicrobial therapy was initiated for this presumptive diagnosis with culture data only proving the TB suspicion correct after nearly 2 months in culture. Anti-viral therapy was initially not felt to be necessary as the HHV-6 was interpreted as incidental and not a cause of symptomatic meningitis in our immunocompetent host. The patient’s hydrocephalus was treated with temporary CSF diversion followed by performance of an endoscopic third ventriculostomy. Despite appropriate hydrocephalus management, clinical improvement ultimately seemed to correlate with the initiation of antiviral therapy. Conclusion: The authors present this case and review the literature on HHV-6-associated CNS infections with the goal of informing the neurosurgeon about this often clinically underestimated pathogen.
- Open Access
- 5 April 2024
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 15, 123
Extradural spinal cyst in a pediatric patient: A case report
Extradural spinal cysts (arachnoid) comprise <1% of all spinal lesions and are rare findings in pediatric patients.
- 5 April 2024
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 15, 123
Open AccessExtradural spinal cyst in a pediatric patient: A case report
Extradural spinal cysts (arachnoid) comprise <1% of all spinal lesions and are rare findings in pediatric patients.
- Open Access
- 25 August 2022
- Published by Springer Nature in Cureus
- Vol. 14  (8) , e28409
Radiographic Predictors of Shunt Dependency in Intracranial Hemorrhage With Intraventricular Extension
Intracranial hemorrhage (ICH) may be complicated by intraventricular hemorrhage (IVH) and hydrocephalus, which can require the placement of a ventriculoperitoneal shunt (VPS). ICH and IVH risk scores using radiographic and clinical characteristics have been developed but utilization for assessment of future need for VPS placement is limited. This is a single-institution retrospective review for patients with primary ICH with IVH from 2018-2020. Initial CTs and charts were analyzed to determine ICH, IVH, LeRoux and Graeb scores, Evans’ index, ICH and IVH volumes, and comorbidities. Outcomes including Glasgow coma scale (GCS), National Institute of Health Stroke Scale (NIHSS), length of stay, and shunt placement were evaluated with bivariate correlations, t-tests, chi-squared tests, and receiver operating characteristic (ROC) curves (p=0.05). A total of 130 patients were included of which 102 underwent full treatment beyond hospital day one. VPS placement was significantly associated with longer length of stay (p<0.001), discharge NIHSS (p=0.001), arrival Evans’ index (p<0.001), IVH (p=0.033), LeRoux (p=0.049), but not comorbidities, ICH score, or admission GCS. When treated beyond hospital day one, Evans’ index (p<0.001), IVH volume (p=0.029), Graeb (p=0.0029), IVH (p=0.004), Slice (p=0.015), and Leroux scores (p=0.006) were associated with shunt placement of which an Evans’ index of 0.31 or greater had highest sensitivity and specificity (area under the ROC curve (AUC) 0.81, sensitivity 81%, specificity 0.76). The higher the Evans’ index, Graeb, IVH, Slice, and LeRoux scores on admission, the higher the risk of shunt dependency in patients undergoing full treatment beyond hospital day one. Admission imaging scores significantly predict the development of shunt dependence and may be considered in treatment.
- 25 August 2022
- Published by Springer Nature in Cureus
- Vol. 14  (8) , e28409
Open AccessRadiographic Predictors of Shunt Dependency in Intracranial Hemorrhage With Intraventricular Extension
Intracranial hemorrhage (ICH) may be complicated by intraventricular hemorrhage (IVH) and hydrocephalus, which can require the placement of a ventriculoperitoneal shunt (VPS). ICH and IVH risk scores using radiographic and clinical characteristics have been developed but utilization for assessment of future need for VPS placement is limited. This is a single-institution retrospective review for patients with primary ICH with IVH from 2018-2020. Initial CTs and charts were analyzed to determine ICH, IVH, LeRoux and Graeb scores, Evans’ index, ICH and IVH volumes, and comorbidities. Outcomes including Glasgow coma scale (GCS), National Institute of Health Stroke Scale (NIHSS), length of stay, and shunt placement were evaluated with bivariate correlations, t-tests, chi-squared tests, and receiver operating characteristic (ROC) curves (p=0.05). A total of 130 patients were included of which 102 underwent full treatment beyond hospital day one. VPS placement was significantly associated with longer length of stay (p<0.001), discharge NIHSS (p=0.001), arrival Evans’ index (p<0.001), IVH (p=0.033), LeRoux (p=0.049), but not comorbidities, ICH score, or admission GCS. When treated beyond hospital day one, Evans’ index (p<0.001), IVH volume (p=0.029), Graeb (p=0.0029), IVH (p=0.004), Slice (p=0.015), and Leroux scores (p=0.006) were associated with shunt placement of which an Evans’ index of 0.31 or greater had highest sensitivity and specificity (area under the ROC curve (AUC) 0.81, sensitivity 81%, specificity 0.76). The higher the Evans’ index, Graeb, IVH, Slice, and LeRoux scores on admission, the higher the risk of shunt dependency in patients undergoing full treatment beyond hospital day one. Admission imaging scores significantly predict the development of shunt dependence and may be considered in treatment.
- Open Access
- 15 August 2022
- Published by Springer Nature in Cureus
- Vol. 14  (8) , e28014
External Ventricular Drain (EVD) Placement Using a Hands-On Training Session on a Simple Three-Dimensional (3D) Model
Neurosurgery is a demanding field with small margins of error within the operative field. Small errors can yield devastating consequences. Simulation has been proposed as a methodology for improving surgical skills within the neurosurgical realm. This study was conducted to investigate a novel realistic design for a clinical simulation based, low-cost alternative of external ventricular drain (EVD) placement, an essential basic neurosurgical procedure that is necessary for clinicians to master. A low-cost three-dimensional (3D) printed head using thermoplastic polylactic acid was designed with the tactile feedback of outer table, cancellous bone, and inner tables for drilling with replaceable frontal bones pieces for multi-use purposes. An agar gel filled with water was designed to simulate tactile passage through the cortex and into the ventricles. Neurosurgical and emergency resident physicians participated in a didactic session and then attempted placement of an EVD using the model to gauge the simulated model for accuracy and realism. Positioning, procedural time, and realism was evaluated. Improvements in procedural time and positioning were identified for both neurosurgical and emergency medicine (EM) residents. Catheter placement was within ideal position for all participants by the third attempt. All residents stated they felt more comfortable with placement with subsequent attempts. Neurosurgical residents subjectively noted similarities in tactile feedback during drilling compared to in-vivo. A low-cost realistic 3D printed model simulating basic neurosurgical procedures demonstrated improved procedural times and precision with neurosurgical and EM residents. Further, similarities between in-vivo tactile feedback and the low-cost simulation technology was noted. This low cost-model may be used as an adjunct for teaching to promote early procedural competency in neurosurgical techniques to promote learning without predisposition to patient morbidity.
- 15 August 2022
- Published by Springer Nature in Cureus
- Vol. 14  (8) , e28014
Open AccessExternal Ventricular Drain (EVD) Placement Using a Hands-On Training Session on a Simple Three-Dimensional (3D) Model
Neurosurgery is a demanding field with small margins of error within the operative field. Small errors can yield devastating consequences. Simulation has been proposed as a methodology for improving surgical skills within the neurosurgical realm. This study was conducted to investigate a novel realistic design for a clinical simulation based, low-cost alternative of external ventricular drain (EVD) placement, an essential basic neurosurgical procedure that is necessary for clinicians to master. A low-cost three-dimensional (3D) printed head using thermoplastic polylactic acid was designed with the tactile feedback of outer table, cancellous bone, and inner tables for drilling with replaceable frontal bones pieces for multi-use purposes. An agar gel filled with water was designed to simulate tactile passage through the cortex and into the ventricles. Neurosurgical and emergency resident physicians participated in a didactic session and then attempted placement of an EVD using the model to gauge the simulated model for accuracy and realism. Positioning, procedural time, and realism was evaluated. Improvements in procedural time and positioning were identified for both neurosurgical and emergency medicine (EM) residents. Catheter placement was within ideal position for all participants by the third attempt. All residents stated they felt more comfortable with placement with subsequent attempts. Neurosurgical residents subjectively noted similarities in tactile feedback during drilling compared to in-vivo. A low-cost realistic 3D printed model simulating basic neurosurgical procedures demonstrated improved procedural times and precision with neurosurgical and EM residents. Further, similarities between in-vivo tactile feedback and the low-cost simulation technology was noted. This low cost-model may be used as an adjunct for teaching to promote early procedural competency in neurosurgical techniques to promote learning without predisposition to patient morbidity.
- Open Access
- 27 May 2022
- Published by Springer Nature in Cureus
- Vol. 14  (5) , e25406
Changing Frequency of the Use of Intraoperative Equipment Among Neurosurgeons, Neurosurgery Residency Faculty, and Neurosurgery Residents
Neurosurgical procedures have relied on the use of various intraoperative equipment since its advent. These include an operative microscope, ultrasound, and loupes with a headlight. The necessity of these pieces of equipment makes them vital in the training of residents as well. A national survey utilizing a Likert scale to determine how often loupes, microscopes, and ultrasound were used for various neurosurgeries was created. This was then compared to a single program’s responses, and it identified that the practice parameters of residents closely modeled those behaviors portrayed by their attending mentors. It appears that the higher frequency of use by residents when compared to faculty and neurosurgeons nationwide highlights the importance of this equipment in training neurosurgical residents. As such, they should be available to residents from the onset of training to promote the highest quality of learning. Faculty should encourage the use of this equipment by leading by example, and residents, in turn, should use all the available equipment as often as possible to maximize the quality of their training. Modulating the use of learning technologies can be accomplished if it is a nationally accepted practice, discussed in an academic setting with the residents, and modeled by the faculty.
- 27 May 2022
- Published by Springer Nature in Cureus
- Vol. 14  (5) , e25406
Open AccessChanging Frequency of the Use of Intraoperative Equipment Among Neurosurgeons, Neurosurgery Residency Faculty, and Neurosurgery Residents
Neurosurgical procedures have relied on the use of various intraoperative equipment since its advent. These include an operative microscope, ultrasound, and loupes with a headlight. The necessity of these pieces of equipment makes them vital in the training of residents as well. A national survey utilizing a Likert scale to determine how often loupes, microscopes, and ultrasound were used for various neurosurgeries was created. This was then compared to a single program’s responses, and it identified that the practice parameters of residents closely modeled those behaviors portrayed by their attending mentors. It appears that the higher frequency of use by residents when compared to faculty and neurosurgeons nationwide highlights the importance of this equipment in training neurosurgical residents. As such, they should be available to residents from the onset of training to promote the highest quality of learning. Faculty should encourage the use of this equipment by leading by example, and residents, in turn, should use all the available equipment as often as possible to maximize the quality of their training. Modulating the use of learning technologies can be accomplished if it is a nationally accepted practice, discussed in an academic setting with the residents, and modeled by the faculty.
- Open Access
- 13 April 2022
- Published by Springer Nature in Cureus
- Vol. 14  (4) , e24107
Measuring the Electromagnetic Field of Human Subjects Using Induction Sensors and a Shielded Helmet Without the Need for a Shielded Room
Neurologic activity is mediated by electrochemical signaling pathways that generate an electric charge. These electrical signals generate electromagnetic fields (EMF) that have been found to be measurable through magnetoencephalography and induction sensors. These technologies typically rely on expensive shielding via shielded rooms to remove influence from the external environment. We aimed to investigate the effects of a lightweight shielded helmet constructed of Mu-metal and interlaced copper mesh and Mu-metal EMF “channels” on shielding externally mediated EMF when measuring cortically generated EMF during human activity. Non-contact, non-invasive, proprietary induction sensors were utilized with a combination of a dual-layer Mu-metal and interlaced copper mesh helmet with sensors placed within EMF channels connected to the helmet. Five human volunteers participated in motor activities, verbalization activities, and visual object naming to evaluate the effectiveness of shielding solely via the helmet and EMF channel construct on generated EMF without placement of individuals within a shielded room. Background data without a subject were obtained. Differences in fast Fourier transformed data were noted in the background compared to rest and various activities throughout all trials. There were differences in rest phases and activity phases in each individual identifying active measurement of differences in cortically generated EMF during each activity. It appears that eliminating a Mu-metal shielded room is possible when shielding is isolated to the helmet and EMF channels with induction sensors. The external EMF was appropriately excluded with differences in background data in all trials. During the activity, differences were noted between rest phases and activity phases in all activities noting the discernibility of these induction sensors in measuring cortically generated EMF. Measured activity through motor tapping with changes between 4 and 6 Hz appeared to correlate with previously documented changes during motor activity using these sensors in conjunction with shielded rooms.
- 13 April 2022
- Published by Springer Nature in Cureus
- Vol. 14  (4) , e24107
Open AccessMeasuring the Electromagnetic Field of Human Subjects Using Induction Sensors and a Shielded Helmet Without the Need for a Shielded Room
Neurologic activity is mediated by electrochemical signaling pathways that generate an electric charge. These electrical signals generate electromagnetic fields (EMF) that have been found to be measurable through magnetoencephalography and induction sensors. These technologies typically rely on expensive shielding via shielded rooms to remove influence from the external environment. We aimed to investigate the effects of a lightweight shielded helmet constructed of Mu-metal and interlaced copper mesh and Mu-metal EMF “channels” on shielding externally mediated EMF when measuring cortically generated EMF during human activity. Non-contact, non-invasive, proprietary induction sensors were utilized with a combination of a dual-layer Mu-metal and interlaced copper mesh helmet with sensors placed within EMF channels connected to the helmet. Five human volunteers participated in motor activities, verbalization activities, and visual object naming to evaluate the effectiveness of shielding solely via the helmet and EMF channel construct on generated EMF without placement of individuals within a shielded room. Background data without a subject were obtained. Differences in fast Fourier transformed data were noted in the background compared to rest and various activities throughout all trials. There were differences in rest phases and activity phases in each individual identifying active measurement of differences in cortically generated EMF during each activity. It appears that eliminating a Mu-metal shielded room is possible when shielding is isolated to the helmet and EMF channels with induction sensors. The external EMF was appropriately excluded with differences in background data in all trials. During the activity, differences were noted between rest phases and activity phases in all activities noting the discernibility of these induction sensors in measuring cortically generated EMF. Measured activity through motor tapping with changes between 4 and 6 Hz appeared to correlate with previously documented changes during motor activity using these sensors in conjunction with shielded rooms.
- Open Access
- 29 March 2022
- Published by Springer Nature in Cureus
- Vol. 14  (3) , e23626
Measuring the Electromagnetic Field of the Human Brain at a Distance Using a Shielded Electromagnetic Field Channel
The electromagnetic field (EMF) of the human brain generated by the movement of ions in the brain can be measured in a novel manner. The measurement can be completed through the skull, in a non-contact, non-invasive, continuous manner using a lightweight helmet. This investigation was conducted to determine if brain activity from movement and thoughts of movement can be measured at a distance and if that measurement can be readily evaluated at a distance using shielding with a shielded helmet and a shielded EMF channel surrounding a sensor. Non-clinical human subject volunteers donned a lightweight sensor helmet and performed a variety of specific tasks synchronized with an audible tone generated by a metronome. Constructs were created to determine if the human subjects’ brain EMF can be recorded at a distance using sensors surrounded by shielding acting similar to a waveguide in an EMF channel connected to a shielded helmet. The EMF sensors appeared to record brain electromagnetic activity as it is funneled into a shielded channel acting as a waveguide at a considerable distance including distances as far as 63 cm away. Specific brain EMFs from movement, thoughts of movement, and emotional thought can be continuously measured in a non-contact fashion at a distance using an EMF waveguide approach with an EMF channel and shielded helmet.
- 29 March 2022
- Published by Springer Nature in Cureus
- Vol. 14  (3) , e23626
Open AccessMeasuring the Electromagnetic Field of the Human Brain at a Distance Using a Shielded Electromagnetic Field Channel
The electromagnetic field (EMF) of the human brain generated by the movement of ions in the brain can be measured in a novel manner. The measurement can be completed through the skull, in a non-contact, non-invasive, continuous manner using a lightweight helmet. This investigation was conducted to determine if brain activity from movement and thoughts of movement can be measured at a distance and if that measurement can be readily evaluated at a distance using shielding with a shielded helmet and a shielded EMF channel surrounding a sensor. Non-clinical human subject volunteers donned a lightweight sensor helmet and performed a variety of specific tasks synchronized with an audible tone generated by a metronome. Constructs were created to determine if the human subjects’ brain EMF can be recorded at a distance using sensors surrounded by shielding acting similar to a waveguide in an EMF channel connected to a shielded helmet. The EMF sensors appeared to record brain electromagnetic activity as it is funneled into a shielded channel acting as a waveguide at a considerable distance including distances as far as 63 cm away. Specific brain EMFs from movement, thoughts of movement, and emotional thought can be continuously measured in a non-contact fashion at a distance using an EMF waveguide approach with an EMF channel and shielded helmet.
- Open Access
- 20 March 2022
- Published by Springer Nature in Cureus
- Vol. 14  (3) , e23332
Measuring Electromagnetic Field Activity Generated by Neurons In Vivo by Humans With Thoughts of Repetitive Motor Activities and Emotional Thoughts
In this study, a novel method of electromagnetic field (EMF) measurements of the human brain has been performed to evaluate neuronal activity. This measurement in a non-contact, non-invasive, continuous manner through the human skull and scalp in the standard environment is completed through a lightweight inexpensive helmet. We sought to further delineate whether specific activities of complex thought can be identified using this non-invasive technique. Non-clinical human subject volunteers donned a lightweight helmet with attached sensors and performed activities of motor movement, specific motor imagery, and specific emotional imagery synchronized to an audible tone for consistency. The human subjects’ brain EMF was recorded and analyzed. The novel method of continuously recording real-time human brain EMF was able to determine differing brain activity between individuals performing motor movement, motor imagery, and emotional imagery in a non-contact manner at different distances from the scalp. It may be possible to measure specific human brain activity using EMF in a non-invasive fashion. Emotional imagery, motor imagery, and motor movement generate different EMFs that have different discernible forms compared to baseline activity.
- 20 March 2022
- Published by Springer Nature in Cureus
- Vol. 14  (3) , e23332
Open AccessMeasuring Electromagnetic Field Activity Generated by Neurons In Vivo by Humans With Thoughts of Repetitive Motor Activities and Emotional Thoughts
In this study, a novel method of electromagnetic field (EMF) measurements of the human brain has been performed to evaluate neuronal activity. This measurement in a non-contact, non-invasive, continuous manner through the human skull and scalp in the standard environment is completed through a lightweight inexpensive helmet. We sought to further delineate whether specific activities of complex thought can be identified using this non-invasive technique. Non-clinical human subject volunteers donned a lightweight helmet with attached sensors and performed activities of motor movement, specific motor imagery, and specific emotional imagery synchronized to an audible tone for consistency. The human subjects’ brain EMF was recorded and analyzed. The novel method of continuously recording real-time human brain EMF was able to determine differing brain activity between individuals performing motor movement, motor imagery, and emotional imagery in a non-contact manner at different distances from the scalp. It may be possible to measure specific human brain activity using EMF in a non-invasive fashion. Emotional imagery, motor imagery, and motor movement generate different EMFs that have different discernible forms compared to baseline activity.
- Open Access
- 14 March 2022
- Published by Springer Nature in Cureus
- Vol. 14  (3) , e23161
Magnesium Levels and Diastolic Blood Pressure (DBP) as a Vasospasm Prediction Metric in Patients With Aneurysmal Subarachnoid Hemorrhage (SAH)
Vasospasm is a significant cause of morbidity and mortality in patients with aneurysmal subarachnoid hemorrhage (SAH). The purpose of this study is to evaluate a possible link between vasospasm in patients with aneurysmal SAH and magnesium and blood pressure levels. Subjects were selected based on chart review of patients presenting to a comprehensive stroke center in Southern California with aneurysmal SAH. 27 were included based on the following criteria: patients greater than 18 years of age, aneurysmal SAH, clinically symptomatic vasospasms and at least one diagnostic confirmation - either from a transcranial doppler (TCD) or digital subtraction angiogram (DSA). The following exclusion criteria also applied: 1) incomplete documentation in the medical record; 2) patients <18 years of age; and 3) patients without TCD measurements. In an overall analysis of all patients with or without vasospasm, it was found that the presence of vasospasm was significantly correlated with diastolic blood pressures (DBPs) on day of vasospasm with an r value of 0.418 and p<0.001. Average daily DBPs throughout hospital stay were also correlated with vasospasm with an r-value of 0.455 and p<0.001. Changes in magnesium overall were also significantly related to left Lindegaard ratios with an r value of -0.201 and p value of 0.032. Lindegaard ratios were significantly correlated with age with r values of 0.510, p<0.001, and r=-0.482, p<0.001 for left and right, respectively. A change in magnesium was inversely correlated to the left Lindegaard ratio with an n of 31 and p value of 0.014 (r= -0.439) in patients with vasospasm. We also found a lower incidence of vasospasm in patients older than 65. Monitoring magnesium and increases in DBP might be effective as a prophylactic adjunct method in patients with SAH in an effort to predict clinical vasospasm.
- 14 March 2022
- Published by Springer Nature in Cureus
- Vol. 14  (3) , e23161
Open AccessMagnesium Levels and Diastolic Blood Pressure (DBP) as a Vasospasm Prediction Metric in Patients With Aneurysmal Subarachnoid Hemorrhage (SAH)
Vasospasm is a significant cause of morbidity and mortality in patients with aneurysmal subarachnoid hemorrhage (SAH). The purpose of this study is to evaluate a possible link between vasospasm in patients with aneurysmal SAH and magnesium and blood pressure levels. Subjects were selected based on chart review of patients presenting to a comprehensive stroke center in Southern California with aneurysmal SAH. 27 were included based on the following criteria: patients greater than 18 years of age, aneurysmal SAH, clinically symptomatic vasospasms and at least one diagnostic confirmation - either from a transcranial doppler (TCD) or digital subtraction angiogram (DSA). The following exclusion criteria also applied: 1) incomplete documentation in the medical record; 2) patients <18 years of age; and 3) patients without TCD measurements. In an overall analysis of all patients with or without vasospasm, it was found that the presence of vasospasm was significantly correlated with diastolic blood pressures (DBPs) on day of vasospasm with an r value of 0.418 and p<0.001. Average daily DBPs throughout hospital stay were also correlated with vasospasm with an r-value of 0.455 and p<0.001. Changes in magnesium overall were also significantly related to left Lindegaard ratios with an r value of -0.201 and p value of 0.032. Lindegaard ratios were significantly correlated with age with r values of 0.510, p<0.001, and r=-0.482, p<0.001 for left and right, respectively. A change in magnesium was inversely correlated to the left Lindegaard ratio with an n of 31 and p value of 0.014 (r= -0.439) in patients with vasospasm. We also found a lower incidence of vasospasm in patients older than 65. Monitoring magnesium and increases in DBP might be effective as a prophylactic adjunct method in patients with SAH in an effort to predict clinical vasospasm.
- Open Access
- 9 March 2022
- Published by Springer Nature in Cureus
- Vol. 14  (3) , e23006
Evaluating the Intrinsic Electromagnetic Field Generated by Neurons From Repetitive Motor Activities in Humans With a Non-contact Non-invasive Electromagnetic Helmet
The actions of neurons are dependent on electrochemical signal pathways mediated by neurotransmitters and create measurable electrical charges. These charges have been found to be measurable through neuroimaging technologies and now through a novel non-contact non-invasive sensor without supercooling. Identifying whether this technology can be appropriately interpreted with synchronized motor well-defined activities in vivo may allow for further clinical applications. A non-contact, non-invasive helmet constructed and modified using shielding technology with proprietary magnetic field sensors was utilized to measure the brain’s electromagnetic field (EMF). Human volunteers donned helmets and were asked to perform repetitive tapping exercises in order to identify waves consistent with tapping from the left and right hemispheres. A gyroscope was utilized to ensure that measured waves were not from micro-movement but were from neuronal firing. Multiple individuals were tested to evaluate the reproducibility of tapping and commonalities between individuals Right and left-sided tapping generated discernible wave changes from baseline measurements obtained by the helmet without a subject as well as differed from when the subject was at rest. Wave patterns varied from person to person but were overall similar in each subject individually. Shielding was necessary to identify signals but EMF was identified when shielding was transitioned from around the helmet to within the helmet design. It is possible to measure in-vivo electromagnetic fields generated by the human brain generated by stereotyped tasks in a non-contact non-invasive manner. These waves were reliably obtained within each individual with some variability in morphology from subject to subject however were similar in each subject. Signals varied based on activity and stereotyped motor activities were identified. A helmet using shielding technology within the helmet itself was able to effectively identify EMF signals. Future analysis may focus on translating these waves into functional mapping for clinical applications.
- 9 March 2022
- Published by Springer Nature in Cureus
- Vol. 14  (3) , e23006
Open AccessEvaluating the Intrinsic Electromagnetic Field Generated by Neurons From Repetitive Motor Activities in Humans With a Non-contact Non-invasive Electromagnetic Helmet
The actions of neurons are dependent on electrochemical signal pathways mediated by neurotransmitters and create measurable electrical charges. These charges have been found to be measurable through neuroimaging technologies and now through a novel non-contact non-invasive sensor without supercooling. Identifying whether this technology can be appropriately interpreted with synchronized motor well-defined activities in vivo may allow for further clinical applications. A non-contact, non-invasive helmet constructed and modified using shielding technology with proprietary magnetic field sensors was utilized to measure the brain’s electromagnetic field (EMF). Human volunteers donned helmets and were asked to perform repetitive tapping exercises in order to identify waves consistent with tapping from the left and right hemispheres. A gyroscope was utilized to ensure that measured waves were not from micro-movement but were from neuronal firing. Multiple individuals were tested to evaluate the reproducibility of tapping and commonalities between individuals Right and left-sided tapping generated discernible wave changes from baseline measurements obtained by the helmet without a subject as well as differed from when the subject was at rest. Wave patterns varied from person to person but were overall similar in each subject individually. Shielding was necessary to identify signals but EMF was identified when shielding was transitioned from around the helmet to within the helmet design. It is possible to measure in-vivo electromagnetic fields generated by the human brain generated by stereotyped tasks in a non-contact non-invasive manner. These waves were reliably obtained within each individual with some variability in morphology from subject to subject however were similar in each subject. Signals varied based on activity and stereotyped motor activities were identified. A helmet using shielding technology within the helmet itself was able to effectively identify EMF signals. Future analysis may focus on translating these waves into functional mapping for clinical applications.