Ayobami S. Edun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ayobami S. Edun has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Cynthia Furse
Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, UT 84112, USA
13 shared publications - Joel B. Harley
Department of Electrical and Computer Engineering, University of Florida, Gainesville, FL, USA
13 shared publications - Michael A. Scarpulla
University of Utah
10 shared publications - Evan Benoit
Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, UT, USA
8 shared publications - Cody LaFlamme
Department of Electrical and Computer Engineering, University of Florida, Gainesville, FL, USA
5 shared publications - Mashad Uddin Saleh
Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, UT 84112 USA
3 shared publications
Latest Publications
- 29 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Photovoltaics
- Vol. 15 (6) , 915-924
A Statistical Analysis of Fault Detection in Photovoltaics Using Reflectometry
Spread spectrum time domain reflectometry (SSTDR) has been used to detect different kinds of faults in cables, aircraft wiring, and photovoltaic (PV) setups. One significant problem is that, since most methods that use reflectometry are based on a comparison with a known baseline, variations in the baseline caused by system or environmental variations can overshadow the reflections produced by faults and reduce the probability of detection. The effects of these variations are exacerbated for faults far from the test device. The objective of this work is to statistically estimate the probability that a reflection from a PV array is or is not a fault amid environmental variations, system variations, and at different locations along the line. Our results show the probability of detecting fault presence at different distances from the test device when there are partial and full disconnects over a range of signal-to-noise ratio (SNR). At a distance of 97.54 m (320 ft) from the tester, the probability of detection of a full disconnect is as high as 0.75 with an SNR of about 9 dB, while the probability of detection is nearly zero for partial faults at the same location. We also present scenarios where faults can no longer be detected and how averaging could help improve the probability of detection.
- 29 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Photovoltaics
- Vol. 15 (6) , 915-924
A Statistical Analysis of Fault Detection in Photovoltaics Using Reflectometry
Spread spectrum time domain reflectometry (SSTDR) has been used to detect different kinds of faults in cables, aircraft wiring, and photovoltaic (PV) setups. One significant problem is that, since most methods that use reflectometry are based on a comparison with a known baseline, variations in the baseline caused by system or environmental variations can overshadow the reflections produced by faults and reduce the probability of detection. The effects of these variations are exacerbated for faults far from the test device. The objective of this work is to statistically estimate the probability that a reflection from a PV array is or is not a fault amid environmental variations, system variations, and at different locations along the line. Our results show the probability of detecting fault presence at different distances from the test device when there are partial and full disconnects over a range of signal-to-noise ratio (SNR). At a distance of 97.54 m (320 ft) from the tester, the probability of detection of a full disconnect is as high as 0.75 with an SNR of about 9 dB, while the probability of detection is nearly zero for partial faults at the same location. We also present scenarios where faults can no longer be detected and how averaging could help improve the probability of detection.
- 15 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (16) , 26181-26189
Reducing the Effects of Rain and Moisture on Spread Spectrum Time-Domain Reflectometry Monitoring of Photovoltaics
This paper addresses the challenges resulting from the effects of moisture and rain on the velocity of propagation (VOP) in a spread spectrum time domain reflectometry (SSTDR) monitoring system for detecting and locating faults within a photovoltaic string. A change in the VOP results in shifts of the SSTDR reflection peaks and prevents accurate localization of faults by the monitoring system. Two algorithms, the scale transform and dynamic time warping, are studied as solutions to mitigate these VOP variations. The scale transform algorithm uniformly stretches signals to align with the baseline, while dynamic time warping allows for variable stretching and contracting factors. Both transforms are used to adjust for the changes in VOP to better align data with a known baseline signal, allowing the difference to be used for fault detection and localization. Experimental results demonstrate the influence of rain on VOP within photovoltaic (PV) systems and compare the performance of the scale transform and dynamic time warping algorithms. Both algorithms significantly reduce variability in the data and improve the ability to detect and locate faults within the PV cabling. The scale transform is shown to be generally more robust to the variations.
- 15 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (16) , 26181-26189
Reducing the Effects of Rain and Moisture on Spread Spectrum Time-Domain Reflectometry Monitoring of Photovoltaics
This paper addresses the challenges resulting from the effects of moisture and rain on the velocity of propagation (VOP) in a spread spectrum time domain reflectometry (SSTDR) monitoring system for detecting and locating faults within a photovoltaic string. A change in the VOP results in shifts of the SSTDR reflection peaks and prevents accurate localization of faults by the monitoring system. Two algorithms, the scale transform and dynamic time warping, are studied as solutions to mitigate these VOP variations. The scale transform algorithm uniformly stretches signals to align with the baseline, while dynamic time warping allows for variable stretching and contracting factors. Both transforms are used to adjust for the changes in VOP to better align data with a known baseline signal, allowing the difference to be used for fault detection and localization. Experimental results demonstrate the influence of rain on VOP within photovoltaic (PV) systems and compare the performance of the scale transform and dynamic time warping algorithms. Both algorithms significantly reduce variability in the data and improve the ability to detect and locate faults within the PV cabling. The scale transform is shown to be generally more robust to the variations.
- 6 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (4) , 3484-3492
Anomaly Detection of Disconnects Using SSTDR and Variational Autoencoders
This article utilizes variational autoencoder (VAE) and spread spectrum time domain reflectometry (SSTDR) to detect, isolate, and characterize anomalous data (or faults) in a photovoltaic (PV) array. The goal is to learn the distribution of non-faulty input signals, inspect the reconstruction error of test signals, flag anomalies, and then locate or characterize the anomalous data using a predicted baseline rather than a fixed baseline that might be too rigid. The use of VAE handles imbalanced data better than other methods used for classification of PV faults because of its unsupervised nature. We consider only disconnects in this work, and our results show an overall accuracy of 96% for detecting true negatives (non-faulty data), a 99% true positive rate of detecting anomalies, 0.997 area under the ROC curve, 0.99 area under the precision-recall curve, and a maximum percentage absolute relative error of 0.40% in locating the faults on a 5-panel setup with a 59.13 m leader cable.
- 6 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (4) , 3484-3492
Anomaly Detection of Disconnects Using SSTDR and Variational Autoencoders
This article utilizes variational autoencoder (VAE) and spread spectrum time domain reflectometry (SSTDR) to detect, isolate, and characterize anomalous data (or faults) in a photovoltaic (PV) array. The goal is to learn the distribution of non-faulty input signals, inspect the reconstruction error of test signals, flag anomalies, and then locate or characterize the anomalous data using a predicted baseline rather than a fixed baseline that might be too rigid. The use of VAE handles imbalanced data better than other methods used for classification of PV faults because of its unsupervised nature. We consider only disconnects in this work, and our results show an overall accuracy of 96% for detecting true negatives (non-faulty data), a 99% true positive rate of detecting anomalies, 0.997 area under the ROC curve, 0.99 area under the precision-recall curve, and a maximum percentage absolute relative error of 0.40% in locating the faults on a 5-panel setup with a 59.13 m leader cable.
- 30 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Photovoltaics
- Vol. 12 (1) , 381-387
Quantifying the Environmental Sensitivity of SSTDR Signals for Monitoring PV Strings
Current spread spectrum time-domain reflectometry (SSTDR) fault detection methods in photovoltaics compare measurements with a fault-free baselin. Yet, environmental factors, such as illuminance, temperature, and humidity, affect these signals and can negatively affect our ability to detect and locate faults. This article explains and quantifies the effects of environmental factors on SSTDR measurements. We demonstrate that illuminance, temperature, and humidity each significantly affect reflections from photovoltaic panels, which require the use of up to 240 baselines to prevent environmental variation from obscuring faults. We present a method to determine the number of required baselines in any given climate and motivate future work in baseline prediction.
- 30 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Photovoltaics
- Vol. 12 (1) , 381-387
Quantifying the Environmental Sensitivity of SSTDR Signals for Monitoring PV Strings
Current spread spectrum time-domain reflectometry (SSTDR) fault detection methods in photovoltaics compare measurements with a fault-free baselin. Yet, environmental factors, such as illuminance, temperature, and humidity, affect these signals and can negatively affect our ability to detect and locate faults. This article explains and quantifies the effects of environmental factors on SSTDR measurements. We demonstrate that illuminance, temperature, and humidity each significantly affect reflections from photovoltaic panels, which require the use of up to 240 baselines to prevent environmental variation from obscuring faults. We present a method to determine the number of required baselines in any given climate and motivate future work in baseline prediction.
- 18 October 2021
- Published by Springer Nature in SN Computer Science
- Vol. 2 (6) , 1-16
Dynamic Scheduling for Heterogeneous Multicores
- 18 October 2021
- Published by Springer Nature in SN Computer Science
- Vol. 2 (6) , 1-16
Dynamic Scheduling for Heterogeneous Multicores
- 1 September 2021
- Published by Elsevier in Applied Energy
- Vol. 298
Unsupervised azimuth estimation of solar arrays in low-resolution satellite imagery through semantic segmentation and Hough transform
- 1 September 2021
- Published by Elsevier in Applied Energy
- Vol. 298
Unsupervised azimuth estimation of solar arrays in low-resolution satellite imagery through semantic segmentation and Hough transform
- Open Access
A SSTDR Methodology, Implementations, and Challenges
Sequence time-domain reflectometry (STDR) and spread spectrum time-domain reflectometry (SSTDR) detect, locate, and diagnose faults in live (energized) electrical systems. In this paper, we survey the present SSTDR literature for discussions on theory, algorithms used in its analysis, and its more prominent implementations and applications. Our review includes both scientific litera-ture and selected patents. We also discuss future applications of SSTDR.
Open AccessA SSTDR Methodology, Implementations, and Challenges
Sequence time-domain reflectometry (STDR) and spread spectrum time-domain reflectometry (SSTDR) detect, locate, and diagnose faults in live (energized) electrical systems. In this paper, we survey the present SSTDR literature for discussions on theory, algorithms used in its analysis, and its more prominent implementations and applications. Our review includes both scientific litera-ture and selected patents. We also discuss future applications of SSTDR.
- Open Access
- 16 July 2021
- Published by ASME International
Spread Spectrum Time Domain Reflectometry for Health Monitoring of Solar Arrays
This abstract describes the capabilities of spread spectrum time domain reflectometry (SSTDR) technology for whole-system (cells/modules, wiring, interconnections, etc.) fault detection, localization, and monitoring on energized and de-energized solar arrays. Electrical faults (e.g., disconnects, ground faults, and arc faults) remain an extremely challenging problem for the solar
- 16 July 2021
- Published by ASME International
Open AccessSpread Spectrum Time Domain Reflectometry for Health Monitoring of Solar Arrays
This abstract describes the capabilities of spread spectrum time domain reflectometry (SSTDR) technology for whole-system (cells/modules, wiring, interconnections, etc.) fault detection, localization, and monitoring on energized and de-energized solar arrays. Electrical faults (e.g., disconnects, ground faults, and arc faults) remain an extremely challenging problem for the solar
- 2 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Photovoltaics
- Vol. 11 (4) , 1097-1104
Detection and Localization of Disconnections in a Large-Scale String of Photovoltaics Using SSTDR
In this article, we explore the possibility of using spread spectrum time domain reflectometry (SSTDR) for detecting disconnections in a large-scale photovoltaic (PV) array. We discuss the importance, role, and trade-offs of SSTDR resolution, frequency, and attenuation in detecting disconnects in the system. Our results show that if the proper system parameters are chosen, disconnections can be detected in a 1-kV system consisting of twenty-six 60-cell PV panels and located within 1.52 m for the first 22 modules.
- 2 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Photovoltaics
- Vol. 11 (4) , 1097-1104
Detection and Localization of Disconnections in a Large-Scale String of Photovoltaics Using SSTDR
In this article, we explore the possibility of using spread spectrum time domain reflectometry (SSTDR) for detecting disconnections in a large-scale photovoltaic (PV) array. We discuss the importance, role, and trade-offs of SSTDR resolution, frequency, and attenuation in detecting disconnects in the system. Our results show that if the proper system parameters are chosen, disconnections can be detected in a 1-kV system consisting of twenty-six 60-cell PV panels and located within 1.52 m for the first 22 modules.
- Open Access
- 16 March 2021
- Published by River Publishers in Applied Computational Electromagnetics Society Journal (ACES)
- Vol. 36 (2) , 190-198
Spread Spectrum Time Domain Reflectometry and Steepest Descent Inversion Spread Spectrum Time Domain Reflectometry and Steepest Descent Inversion
In this paper, we present a method for estimating complex impedances using reflectometry and a modified steepest descent inversion algorithm. We simulate spread spectrum time domain reflectometry (SSTDR), which can measure complex impedances on energized systems for an experimental setup with resistive and capacitive loads. A parametric function, which includes both a misfit function and stabilizer function, is created. The misfit function is a least squares estimate of how close the model data matches observed data. The stabilizer function prevents the steepest descent algorithm from becoming unstable and diverging. Steepest descent iteratively identifies the model parameters that minimize the parametric function. We validate the algorithm by correctly identifying the model parameters (capacitance and resistance) associated with simulated SSTDR data, with added 3 dB white Gaussian noise. With the stabilizer function, the steepest descent algorithm estimates of the model parameters are bounded within a specified range. The errors for capacitance (220pF to 820pF) and resistance (50 Ω to 270 Ω) are < 10%, corresponding to a complex impedance magnitude |R +1/jωC| of 53 Ω to 510 Ω.
- 16 March 2021
- Published by River Publishers in Applied Computational Electromagnetics Society Journal (ACES)
- Vol. 36 (2) , 190-198
Open AccessSpread Spectrum Time Domain Reflectometry and Steepest Descent Inversion Spread Spectrum Time Domain Reflectometry and Steepest Descent Inversion
In this paper, we present a method for estimating complex impedances using reflectometry and a modified steepest descent inversion algorithm. We simulate spread spectrum time domain reflectometry (SSTDR), which can measure complex impedances on energized systems for an experimental setup with resistive and capacitive loads. A parametric function, which includes both a misfit function and stabilizer function, is created. The misfit function is a least squares estimate of how close the model data matches observed data. The stabilizer function prevents the steepest descent algorithm from becoming unstable and diverging. Steepest descent iteratively identifies the model parameters that minimize the parametric function. We validate the algorithm by correctly identifying the model parameters (capacitance and resistance) associated with simulated SSTDR data, with added 3 dB white Gaussian noise. With the stabilizer function, the steepest descent algorithm estimates of the model parameters are bounded within a specified range. The errors for capacitance (220pF to 820pF) and resistance (50 Ω to 270 Ω) are < 10%, corresponding to a complex impedance magnitude |R +1/jωC| of 53 Ω to 510 Ω.