Jie Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jie Zhang has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Guoping Shan
Department of Radiation Physics Zhejiang Cancer Hospital Hangzhou Zhejiang China
6 shared publications- Xue Bai
Zhejiang Cancer Hospital, Hangzhou, China
4 shared publications - Binbing Wang
Zhejiang Cancer Hospital, Hangzhou, China
3 shared publications Kainan Shao
Institute of Cancer and Medicine, Chinese Academy of Sciences, Hangzhou, China
3 shared publicationsMin Fang
Institute of Cancer and Medicine, Chinese Academy of Sciences, Hangzhou, China
2 shared publicationsMing Chen
Department of Radiation Physics, Cancer Hospital of the University of Chinese Academy of Sciences (Zhejiang Cancer Hospital), China
2 shared publications
Latest Publications
- Open Access
- 19 February 2026
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 119
Enhance four-dimensional cone-beam computed tomography (4D-CBCT) from sparse view acquisitions using a novel deep learning model
- 19 February 2026
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 119
Open AccessEnhance four-dimensional cone-beam computed tomography (4D-CBCT) from sparse view acquisitions using a novel deep learning model
- Open Access
- 5 April 2025
- Published by Wiley in Medical Physics
- Vol. 52 (7)
Deep learning‐based estimation of respiration‐induced deformation from surface motion: A proof‐of‐concept study on 4D thoracic image synthesis
Background: Four‐dimension computed tomography (4D‐CT) provides important respiration‐related information for thoracic radiotherapy. Its quality is challenged by various respiratory patterns. Its acquisition gives rise to the risk of higher radiation exposure. Based on a continuously estimated deformation, a 4D synthesis by warping a high‐quality volumetric image is a possible solution. Purpose: To propose a non‐patient‐specific cascaded ensemble model (CEM) to estimate respiration‐induced thoracic tissue deformation from surface motion. Methods: The CEM is cascaded by three deep learning‐based models. By inputting the surface motion, CEM outputs a deformation vector field (DVF) inside thorax. In our work, the surface motion was simulated using the body contours derived from 4D‐CT. The CEM was trained on our private database including 62 4D‐CT sets, and was tested on a public database encompassing 80 4D‐CT sets. To evaluate CEM, we employed the model output DVF to generate a few series of synthesized CTs, and compared them with the ground truth. CEM was also compared with other published works. Results: CEM synthesized CT with an mRMSE (average root mean square error) of 61.06 ± 10.43HU (average ± standard deviation), an mSSIM (average structural similarity index measure) of 0.990 ± 0.004, and an mMAE (average mean absolute error) of 26.80 ± 5.65HU. Compared with other works, CEM showed the best result. Conclusions: The results demonstrated the effectiveness of CEM on estimating tissue DVF inside thorax. CEM requires no patient‐specific breathing data sampling and no additional training before treatment. It shows potential for broad applications.
- 5 April 2025
- Published by Wiley in Medical Physics
- Vol. 52 (7)
Open AccessDeep learning‐based estimation of respiration‐induced deformation from surface motion: A proof‐of‐concept study on 4D thoracic image synthesis
Background: Four‐dimension computed tomography (4D‐CT) provides important respiration‐related information for thoracic radiotherapy. Its quality is challenged by various respiratory patterns. Its acquisition gives rise to the risk of higher radiation exposure. Based on a continuously estimated deformation, a 4D synthesis by warping a high‐quality volumetric image is a possible solution. Purpose: To propose a non‐patient‐specific cascaded ensemble model (CEM) to estimate respiration‐induced thoracic tissue deformation from surface motion. Methods: The CEM is cascaded by three deep learning‐based models. By inputting the surface motion, CEM outputs a deformation vector field (DVF) inside thorax. In our work, the surface motion was simulated using the body contours derived from 4D‐CT. The CEM was trained on our private database including 62 4D‐CT sets, and was tested on a public database encompassing 80 4D‐CT sets. To evaluate CEM, we employed the model output DVF to generate a few series of synthesized CTs, and compared them with the ground truth. CEM was also compared with other published works. Results: CEM synthesized CT with an mRMSE (average root mean square error) of 61.06 ± 10.43HU (average ± standard deviation), an mSSIM (average structural similarity index measure) of 0.990 ± 0.004, and an mMAE (average mean absolute error) of 26.80 ± 5.65HU. Compared with other works, CEM showed the best result. Conclusions: The results demonstrated the effectiveness of CEM on estimating tissue DVF inside thorax. CEM requires no patient‐specific breathing data sampling and no additional training before treatment. It shows potential for broad applications.
- Open Access
- 1 April 2024
- Published by SAGE Publications in Dose-Response
- Vol. 22 (2)
A Review of Artificial Intelligence Application for Radiotherapy
Background and Purpose: Artificial intelligence (AI) is a technique which tries to think like humans and mimic human behaviors. It has been considered as an alternative in a lot of human-dependent steps in radiotherapy (RT), since the human participation is a principal uncertainty source in RT. The aim of this work is to provide a systematic summary of the current literature on AI application for RT, and to clarify its role for RT practice in terms of clinical views. Materials and Methods: A systematic literature search of PubMed and Google Scholar was performed to identify original articles involving the AI applications in RT from the inception to 2022. Studies were included if they reported original data and explored the clinical applications of AI in RT. Results: The selected studies were categorized into three aspects of RT: organ and lesion segmentation, treatment planning and quality assurance. For each aspect, this review discussed how these AI tools could be involved in the RT protocol. Conclusions: Our study revealed that AI was a potential alternative for the human-dependent steps in the complex process of RT.
- 1 April 2024
- Published by SAGE Publications in Dose-Response
- Vol. 22 (2)
Open AccessA Review of Artificial Intelligence Application for Radiotherapy
Background and Purpose: Artificial intelligence (AI) is a technique which tries to think like humans and mimic human behaviors. It has been considered as an alternative in a lot of human-dependent steps in radiotherapy (RT), since the human participation is a principal uncertainty source in RT. The aim of this work is to provide a systematic summary of the current literature on AI application for RT, and to clarify its role for RT practice in terms of clinical views. Materials and Methods: A systematic literature search of PubMed and Google Scholar was performed to identify original articles involving the AI applications in RT from the inception to 2022. Studies were included if they reported original data and explored the clinical applications of AI in RT. Results: The selected studies were categorized into three aspects of RT: organ and lesion segmentation, treatment planning and quality assurance. For each aspect, this review discussed how these AI tools could be involved in the RT protocol. Conclusions: Our study revealed that AI was a potential alternative for the human-dependent steps in the complex process of RT.
- Open Access
- 22 September 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (19) , 195009
Extracting lung contour deformation features with deep learning for internal target motion tracking: a preliminary study
Objective . To propose lung contour deformation features (LCDFs) as a surrogate to estimate the thoracic internal target motion, and to report their performance by correlating with the changing body using a cascade ensemble model (CEM). LCDFs, correlated to the respiration driver, are employed without patient-specific motion data sampling and additional training before treatment. Approach . LCDFs are extracted by matching lung contours via an encoder–decoder deep learning model. CEM estimates LCDFs from the currently captured body, and then uses the estimated LCDFs to track internal target motion. The accuracy of the proposed LCDFs and CEM were evaluated using 48 targets’ motion data, and compared with other published methods. Main results . LCDFs estimated the internal targets with a localization error of 2.6 ± 1.0 mm (average ± standard deviation). CEM reached a localization error of 4.7 ± 0.9 mm and a real-time performance of 256.9 ± 6.0 ms. With no internal anatomy knowledge, they achieved a small accuracy difference (of 0.34∼1.10 mm for LCDFs and of 0.43∼1.75 mm for CEM at the 95% confidence level) with a patient-specific lung biomechanical model and the deformable image registration models. Significance . The results demonstrated the effectiveness of LCDFs and CEM on tracking target motion. LCDFs and CEM are non-invasive, and require no patient-specific training before treatment. They show potential for broad applications.
- 22 September 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (19) , 195009
Open AccessExtracting lung contour deformation features with deep learning for internal target motion tracking: a preliminary study
Objective . To propose lung contour deformation features (LCDFs) as a surrogate to estimate the thoracic internal target motion, and to report their performance by correlating with the changing body using a cascade ensemble model (CEM). LCDFs, correlated to the respiration driver, are employed without patient-specific motion data sampling and additional training before treatment. Approach . LCDFs are extracted by matching lung contours via an encoder–decoder deep learning model. CEM estimates LCDFs from the currently captured body, and then uses the estimated LCDFs to track internal target motion. The accuracy of the proposed LCDFs and CEM were evaluated using 48 targets’ motion data, and compared with other published methods. Main results . LCDFs estimated the internal targets with a localization error of 2.6 ± 1.0 mm (average ± standard deviation). CEM reached a localization error of 4.7 ± 0.9 mm and a real-time performance of 256.9 ± 6.0 ms. With no internal anatomy knowledge, they achieved a small accuracy difference (of 0.34∼1.10 mm for LCDFs and of 0.43∼1.75 mm for CEM at the 95% confidence level) with a patient-specific lung biomechanical model and the deformable image registration models. Significance . The results demonstrated the effectiveness of LCDFs and CEM on tracking target motion. LCDFs and CEM are non-invasive, and require no patient-specific training before treatment. They show potential for broad applications.
- Open Access
- 9 October 2021
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 20 (1) , 1-15
Sharp loss: a new loss function for radiotherapy dose prediction based on fully convolutional networks
Background: Neural-network methods have been widely used for the prediction of dose distributions in radiotherapy. However, the prediction accuracy of existing methods may be degraded by the problem of dose imbalance. In this work, a new loss function is proposed to alleviate the dose imbalance and achieve more accurate prediction results. The U-Net architecture was employed to build a prediction model. Our study involved a total of 110 patients with left-breast cancer, who were previously treated by volumetric-modulated arc radiotherapy. The patient dataset was divided into training and test subsets of 100 and 10 cases, respectively. We proposed a novel ‘sharp loss’ function, and a parameter γ was used to adjust the loss properties. The mean square error (MSE) loss and the sharp loss with different γ values were tested and compared using the Wilcoxon signed-rank test. Results: The sharp loss achieved superior dose prediction results compared to those of the MSE loss. The best performance with the MSE loss and the sharp loss was obtained when the parameter γ was set to 100. Specifically, the mean absolute difference values for the planning target volume were 318.87 ± 30.23 for the MSE loss versus 144.15 ± 16.27 for the sharp loss with γ = 100 (p < 0.05). The corresponding values for the ipsilateral lung, the heart, the contralateral lung, and the spinal cord were 278.99 ± 51.68 versus 198.75 ± 61.38 (p < 0.05), 216.99 ± 44.13 versus 144.86 ± 43.98 (p < 0.05), 125.96 ± 66.76 versus 111.86 ± 47.19 (p > 0.05), and 194.30 ± 14.51 versus 168.58 ± 25.97 (p < 0.05), respectively. Conclusions: The sharp loss function could significantly improve the accuracy of radiotherapy dose prediction.
- 9 October 2021
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 20 (1) , 1-15
Open AccessSharp loss: a new loss function for radiotherapy dose prediction based on fully convolutional networks
Background: Neural-network methods have been widely used for the prediction of dose distributions in radiotherapy. However, the prediction accuracy of existing methods may be degraded by the problem of dose imbalance. In this work, a new loss function is proposed to alleviate the dose imbalance and achieve more accurate prediction results. The U-Net architecture was employed to build a prediction model. Our study involved a total of 110 patients with left-breast cancer, who were previously treated by volumetric-modulated arc radiotherapy. The patient dataset was divided into training and test subsets of 100 and 10 cases, respectively. We proposed a novel ‘sharp loss’ function, and a parameter γ was used to adjust the loss properties. The mean square error (MSE) loss and the sharp loss with different γ values were tested and compared using the Wilcoxon signed-rank test. Results: The sharp loss achieved superior dose prediction results compared to those of the MSE loss. The best performance with the MSE loss and the sharp loss was obtained when the parameter γ was set to 100. Specifically, the mean absolute difference values for the planning target volume were 318.87 ± 30.23 for the MSE loss versus 144.15 ± 16.27 for the sharp loss with γ = 100 (p < 0.05). The corresponding values for the ipsilateral lung, the heart, the contralateral lung, and the spinal cord were 278.99 ± 51.68 versus 198.75 ± 61.38 (p < 0.05), 216.99 ± 44.13 versus 144.86 ± 43.98 (p < 0.05), 125.96 ± 66.76 versus 111.86 ± 47.19 (p > 0.05), and 194.30 ± 14.51 versus 168.58 ± 25.97 (p < 0.05), respectively. Conclusions: The sharp loss function could significantly improve the accuracy of radiotherapy dose prediction.
- Open Access
- 1 July 2021
- Published by SAGE Publications in Science Progress
- Vol. 104 (3)
Comparing of two dimensional and three dimensional fully convolutional networks for radiotherapy dose prediction in left-sided breast cancer
Fully convolutional networks were developed for predicting optimal dose distributions for patients with left-sided breast cancer and compared the prediction accuracy between two-dimensional and three-dimensional networks. Sixty cases treated with volumetric modulated arc radiotherapy were analyzed. Among them, 50 cases were randomly chosen to conform the training set, and the remaining 10 were to construct the test set. Two U-Net fully convolutional networks predicted the dose distributions, with two-dimensional and three-dimensional convolution kernels, respectively. Computed tomography images, delineated regions of interest, or their combination were considered as input data. The accuracy of predicted results was evaluated against the clinical dose. Most types of input data retrieved a similar dose to the ground truth for organs at risk (p > 0.05). Overall, the two-dimensional model had higher performance than the three-dimensional model (p < 0.05). Moreover, the two-dimensional region of interest input provided the best prediction results regarding the planning target volume mean percentage difference (2.40 ± 0.18%), heart mean percentage difference (4.28 ± 2.02%), and the gamma index at 80% of the prescription dose are with tolerances of 3 mm and 3% (0.85 ± 0.03), whereas the two-dimensional combined input provided the best prediction regarding ipsilateral lung mean percentage difference (4.16 ± 1.48%), lung mean percentage difference (2.41 ± 0.95%), spinal cord mean percentage difference (0.67 ± 0.40%), and 80% Dice similarity coefficient (0.94 ± 0.01). Statistically, the two-dimensional combined inputs achieved higher prediction accuracy regarding 80% Dice similarity coefficient than the two-dimensional region of interest input (0.94 ± 0.01 vs 0.92 ± 0.01, p < 0.05). The two-dimensional data model retrieves higher performance than its three-dimensional counterpart for dose prediction, especially when using region of interest and combined inputs.
- 1 July 2021
- Published by SAGE Publications in Science Progress
- Vol. 104 (3)
Open AccessComparing of two dimensional and three dimensional fully convolutional networks for radiotherapy dose prediction in left-sided breast cancer
Fully convolutional networks were developed for predicting optimal dose distributions for patients with left-sided breast cancer and compared the prediction accuracy between two-dimensional and three-dimensional networks. Sixty cases treated with volumetric modulated arc radiotherapy were analyzed. Among them, 50 cases were randomly chosen to conform the training set, and the remaining 10 were to construct the test set. Two U-Net fully convolutional networks predicted the dose distributions, with two-dimensional and three-dimensional convolution kernels, respectively. Computed tomography images, delineated regions of interest, or their combination were considered as input data. The accuracy of predicted results was evaluated against the clinical dose. Most types of input data retrieved a similar dose to the ground truth for organs at risk (p > 0.05). Overall, the two-dimensional model had higher performance than the three-dimensional model (p < 0.05). Moreover, the two-dimensional region of interest input provided the best prediction results regarding the planning target volume mean percentage difference (2.40 ± 0.18%), heart mean percentage difference (4.28 ± 2.02%), and the gamma index at 80% of the prescription dose are with tolerances of 3 mm and 3% (0.85 ± 0.03), whereas the two-dimensional combined input provided the best prediction regarding ipsilateral lung mean percentage difference (4.16 ± 1.48%), lung mean percentage difference (2.41 ± 0.95%), spinal cord mean percentage difference (0.67 ± 0.40%), and 80% Dice similarity coefficient (0.94 ± 0.01). Statistically, the two-dimensional combined inputs achieved higher prediction accuracy regarding 80% Dice similarity coefficient than the two-dimensional region of interest input (0.94 ± 0.01 vs 0.92 ± 0.01, p < 0.05). The two-dimensional data model retrieves higher performance than its three-dimensional counterpart for dose prediction, especially when using region of interest and combined inputs.
- Open Access
- 1 April 2021
- Published by SAGE Publications in Science Progress
- Vol. 104 (2)
Fully convolutional network-based multi-output model for automatic segmentation of organs at risk in thorax
To propose a multi-output fully convolutional network (MOFCN) to segment bilateral lung, heart and spinal cord in the planning thoracic computed tomography (CT) slices automatically and simultaneously. The MOFCN includes two components: one main backbone and three branches. The main backbone extracts the features about lung, heart and spinal cord. The extracted features are transferred to three branches which correspond to three organs respectively. The longest branch to segment spinal cord is nine layers, including input and output layers. The MOFCN was evaluated on 19,277 CT slices from 966 patients with cancer in the thorax. In these slices, the organs at risk (OARs) were delineated and validated by experienced radiation oncologists, and served as ground truth for training and evaluation. The data from 61 randomly chosen patients were used for training and validation. The remaining 905 patients’ slices were used for testing. The metric used to evaluate the similarity between the auto-segmented organs and their ground truth was Dice. Besides, we compared the MOFCN with other published models. To assess the distinct output design and the impact of layer number and dilated convolution, we compared MOFCN with a multi-label learning model and its variants. By analyzing the not good performances, we suggested possible solutions. MOFCN achieved Dice of 0.95 ± 0.02 for lung, 0.91 ± 0.03 for heart and 0.87 ± 0.06 for spinal cord. Compared to other models, MOFCN could achieve a comparable accuracy with the least time cost. The results demonstrated the MOFCN’s effectiveness. It uses less parameters to delineate three OARs simultaneously and automatically, and thus shows a relatively low requirement for hardware and has potential for broad application.
- 1 April 2021
- Published by SAGE Publications in Science Progress
- Vol. 104 (2)
Open AccessFully convolutional network-based multi-output model for automatic segmentation of organs at risk in thorax
To propose a multi-output fully convolutional network (MOFCN) to segment bilateral lung, heart and spinal cord in the planning thoracic computed tomography (CT) slices automatically and simultaneously. The MOFCN includes two components: one main backbone and three branches. The main backbone extracts the features about lung, heart and spinal cord. The extracted features are transferred to three branches which correspond to three organs respectively. The longest branch to segment spinal cord is nine layers, including input and output layers. The MOFCN was evaluated on 19,277 CT slices from 966 patients with cancer in the thorax. In these slices, the organs at risk (OARs) were delineated and validated by experienced radiation oncologists, and served as ground truth for training and evaluation. The data from 61 randomly chosen patients were used for training and validation. The remaining 905 patients’ slices were used for testing. The metric used to evaluate the similarity between the auto-segmented organs and their ground truth was Dice. Besides, we compared the MOFCN with other published models. To assess the distinct output design and the impact of layer number and dilated convolution, we compared MOFCN with a multi-label learning model and its variants. By analyzing the not good performances, we suggested possible solutions. MOFCN achieved Dice of 0.95 ± 0.02 for lung, 0.91 ± 0.03 for heart and 0.87 ± 0.06 for spinal cord. Compared to other models, MOFCN could achieve a comparable accuracy with the least time cost. The results demonstrated the MOFCN’s effectiveness. It uses less parameters to delineate three OARs simultaneously and automatically, and thus shows a relatively low requirement for hardware and has potential for broad application.
- Open Access
- 23 April 2020
- Published by Springer Nature in Research Square
A Unet-based Research on the Multi-Output Convolution Neural Network's Ability of Decreasing Mis-identification: Automatic Segmentation of Organs at Risk in Thorax
Background To study a multi-output convolution neural network (CNN)’s capability of reducing mis-identification. Material and Methods To guarantee that the CNN’s output number was the only experiment variable, we used Unet as research object. By modifying it into a multi-output (MO) one, we got a MO-Unet and the conventional single-output Unet (SO-Uent) as a comparing object. All images involved in this study were computed tomography (CT) scans coming from 105 patients with thoracic tumor. 3 organs at risk (OARs), i.e. lung, heart and spinal cord, were delineated by experienced radiation oncologists and were used as ground truth. The two models were both trained with 1240 CTs (856 images for learning and 384 images for monitor) and under the same learning settings. They were both tested on other 886 images. Dice and mis-identification pixels’ number(n) were 2 metrics for evaluation. Results MO-Unet and SO-Unet achieved Dice of 0.9400 ± 0.0612 (average ± standard deviation) and 0.9451 ± 0.0618 for lung, 0.9143 ± 0.1119 and 0.9160 ± 0.1071 for heart, 0.8988 ± 0.0657 and 0.9020 ± 0.0624 for spinal cord respectively. The two models’ all average Dices were ≤ 0.005. For the normalized number of cases with n = 0, MO-Unet and SO-Unet had 97.29% and 96.84% for spinal cord, 88.49% and 90.86% for heart, 81.26% and 77.09% for lung respectively. Compared to SO-Unet, the mis-identification cases of MO-Unet mainly felled in the range of small n. Conclusions The Dice results showed that the two models had comparable overlap. The n results suggested that the MO-Unet was better in decreasing mis-identification. Besides, a MO network is light-weighted to implement more delineation under the same computing source. Therefore, a MO network is promising in segmenting OARs and has the potential for a widespread application in China.
- 23 April 2020
- Published by Springer Nature in Research Square
Open AccessA Unet-based Research on the Multi-Output Convolution Neural Network's Ability of Decreasing Mis-identification: Automatic Segmentation of Organs at Risk in Thorax
Background To study a multi-output convolution neural network (CNN)’s capability of reducing mis-identification. Material and Methods To guarantee that the CNN’s output number was the only experiment variable, we used Unet as research object. By modifying it into a multi-output (MO) one, we got a MO-Unet and the conventional single-output Unet (SO-Uent) as a comparing object. All images involved in this study were computed tomography (CT) scans coming from 105 patients with thoracic tumor. 3 organs at risk (OARs), i.e. lung, heart and spinal cord, were delineated by experienced radiation oncologists and were used as ground truth. The two models were both trained with 1240 CTs (856 images for learning and 384 images for monitor) and under the same learning settings. They were both tested on other 886 images. Dice and mis-identification pixels’ number(n) were 2 metrics for evaluation. Results MO-Unet and SO-Unet achieved Dice of 0.9400 ± 0.0612 (average ± standard deviation) and 0.9451 ± 0.0618 for lung, 0.9143 ± 0.1119 and 0.9160 ± 0.1071 for heart, 0.8988 ± 0.0657 and 0.9020 ± 0.0624 for spinal cord respectively. The two models’ all average Dices were ≤ 0.005. For the normalized number of cases with n = 0, MO-Unet and SO-Unet had 97.29% and 96.84% for spinal cord, 88.49% and 90.86% for heart, 81.26% and 77.09% for lung respectively. Compared to SO-Unet, the mis-identification cases of MO-Unet mainly felled in the range of small n. Conclusions The Dice results showed that the two models had comparable overlap. The n results suggested that the MO-Unet was better in decreasing mis-identification. Besides, a MO network is light-weighted to implement more delineation under the same computing source. Therefore, a MO network is promising in segmenting OARs and has the potential for a widespread application in China.
- Open Access
- 1 January 2020
- Published by SAGE Publications in Technology in Cancer Research & Treatment
- Vol. 19
Automatic Planning for Nasopharyngeal Carcinoma Based on Progressive Optimization in RayStation Treatment Planning System
To evaluate and quantify the planning performance of automatic planning (AP) with manual planning (MP) for nasopharyngeal carcinoma in the RayStation treatment planning system (TPS). A progressive and effective design method for AP of nasopharyngeal carcinoma was realized through automated scripts in this study. A total of 30 patients with nasopharyngeal carcinoma with initial treatment was enrolled. The target coverage, conformity index (CI), homogeneity index (HI), organs at risk sparing, and the efficiency of design and execution were compared between automatic and manual volumetric modulated arc therapy (VMAT) plans. The results of the 2 design methods met the clinical dose requirement. The differences in D95 between the 2 groups in PTV1 and PTV2 showed statistical significance, and the MPs are higher than APs, but the difference in absolute dose was only 0.21% and 0.16%. The results showed that the conformity index of planning target volumes (PTV1, PTV2, PTVnd and PGTVnx+rpn [PGTVnx and PGTVrpn]), homogeneity index of PGTVnx+rpn, and HI of PTVnd in APs are better than that in MPs. For organs at risk, the APs are lower than the MPs, and the difference was statistically significant (P < .05). The manual operation time in APs was 83.21% less than that in MPs, and the computer processing time was 34.22% more. IronPython language designed by RayStation TPS has clinical application value in the design of automatic radiotherapy plan for nasopharyngeal carcinoma. The dose distribution of tumor target and organs at risk in the APs was similar or better than those in the MPs. The time of manual operation in the plan design showed a sharp reduction, thus significantly improving the work efficiency in clinical application.
- 1 January 2020
- Published by SAGE Publications in Technology in Cancer Research & Treatment
- Vol. 19
Open AccessAutomatic Planning for Nasopharyngeal Carcinoma Based on Progressive Optimization in RayStation Treatment Planning System
To evaluate and quantify the planning performance of automatic planning (AP) with manual planning (MP) for nasopharyngeal carcinoma in the RayStation treatment planning system (TPS). A progressive and effective design method for AP of nasopharyngeal carcinoma was realized through automated scripts in this study. A total of 30 patients with nasopharyngeal carcinoma with initial treatment was enrolled. The target coverage, conformity index (CI), homogeneity index (HI), organs at risk sparing, and the efficiency of design and execution were compared between automatic and manual volumetric modulated arc therapy (VMAT) plans. The results of the 2 design methods met the clinical dose requirement. The differences in D95 between the 2 groups in PTV1 and PTV2 showed statistical significance, and the MPs are higher than APs, but the difference in absolute dose was only 0.21% and 0.16%. The results showed that the conformity index of planning target volumes (PTV1, PTV2, PTVnd and PGTVnx+rpn [PGTVnx and PGTVrpn]), homogeneity index of PGTVnx+rpn, and HI of PTVnd in APs are better than that in MPs. For organs at risk, the APs are lower than the MPs, and the difference was statistically significant (P < .05). The manual operation time in APs was 83.21% less than that in MPs, and the computer processing time was 34.22% more. IronPython language designed by RayStation TPS has clinical application value in the design of automatic radiotherapy plan for nasopharyngeal carcinoma. The dose distribution of tumor target and organs at risk in the APs was similar or better than those in the MPs. The time of manual operation in the plan design showed a sharp reduction, thus significantly improving the work efficiency in clinical application.