Barry L. Sharp
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Barry L. Sharp has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Helen J. Reid
Centre for Analytical Science, Department of Chemistry, Loughborough University, Loughborough, UK
2 shared publicationsBarrie J. Masters
1 shared publicationChristopher P. Ingle
Department of Chemistry, Loughborough University, LoughboroughUK
1 shared publication- Grant Craig
Thermo Fisher Scientific (Bremen) GmbH, Bremen, Germany
1 shared publication Jonathan H. Batey
Thermo Elemental, Ion Path, Road Three,Winsford,UK
1 shared publication- Matthew A. Dexter
P S Analytical, Arthur House, Crayfields Industrial Estate, Main Road, Orpington, Kent BR5 3Hp, UK
1 shared publication
Latest Publications
- 17 April 2020
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 35 (5) , 1011-1021
‘Blind time’ – current limitations on laser ablation multi-collector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS) for ultra-transient signal isotope ratio analysis and application to individual sub-micron sized uranium particles
The application of laser ablation multi-collector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS) to the isotope ratio analysis of UOx particles has the potential to improve the isotopic determination of these particles when compared to currently utilised ICP-MS techniques. To investigate this a high-speed, integrated ablation cell and dual concentric injector design was tested in the expectation that the resulting increase in signal to noise ratio and sample ion yield would improve the determination of 234U/238U, 235U/238U and 236U/238U for such materials. However, when compared to a slower washout, more established low-volume cell design, the highly transient signals of the new design proved challenging for the mixed detector array of the multi-collector mass spectrometer, introducing a new bias. We describe a major component of this bias, referred to as ‘blind time’, and model its impact on UOx particle analysis. After accounting for blind time, average precisions for the uranium isotopic composition of sub-micron sized UOx particles using LA-MC-ICP-MS were 3% 1RSD for 235U/238U and 8% 1RSD for 234U/238U. When ablating a glass rather than a UOx particle, uncertainties of 1.3% 1RSD for 235U/238U were achieved for 150 nm equivalent particle sizes using LA-MC-ICP-MS.
- 17 April 2020
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 35 (5) , 1011-1021
‘Blind time’ – current limitations on laser ablation multi-collector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS) for ultra-transient signal isotope ratio analysis and application to individual sub-micron sized uranium particles
The application of laser ablation multi-collector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS) to the isotope ratio analysis of UOx particles has the potential to improve the isotopic determination of these particles when compared to currently utilised ICP-MS techniques. To investigate this a high-speed, integrated ablation cell and dual concentric injector design was tested in the expectation that the resulting increase in signal to noise ratio and sample ion yield would improve the determination of 234U/238U, 235U/238U and 236U/238U for such materials. However, when compared to a slower washout, more established low-volume cell design, the highly transient signals of the new design proved challenging for the mixed detector array of the multi-collector mass spectrometer, introducing a new bias. We describe a major component of this bias, referred to as ‘blind time’, and model its impact on UOx particle analysis. After accounting for blind time, average precisions for the uranium isotopic composition of sub-micron sized UOx particles using LA-MC-ICP-MS were 3% 1RSD for 235U/238U and 8% 1RSD for 234U/238U. When ablating a glass rather than a UOx particle, uncertainties of 1.3% 1RSD for 235U/238U were achieved for 150 nm equivalent particle sizes using LA-MC-ICP-MS.
- 13 February 2002
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 17 (3) , 183-188
The effect of adventitious water in hexapole collision cell inductively coupled plasma mass spectrometry
This paper considers several aspects of the role of water in collision cell inductively coupled plasma mass spectrometry. Studies with water and deuterium oxide, employed both as samples and as impurities in the cell gas, were used to investigate the origins of the polyatomic ions. It was found that no new species were formed in the cell as water from the plasma provides the basic reactive components; however, some were greatly enhanced when the cell gas was deliberately wetted. The reactivity of the water/deuterium oxide dominated the cell chemistry when an unreactive gas such as He was used, indicating a need for careful control of water content, but the effects were greatly reduced when a reactive gas such as hydrogen was also employed. It is concluded that water could be a useful reagent molecule, if its partial pressure can be adequately controlled. Seeking complete removal of water from the reagent gas is unnecessary as there is a baseline contribution from the plasma and, in any case, when reactive reagent gases are used its effect is minimal.
- 13 February 2002
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 17 (3) , 183-188
The effect of adventitious water in hexapole collision cell inductively coupled plasma mass spectrometry
This paper considers several aspects of the role of water in collision cell inductively coupled plasma mass spectrometry. Studies with water and deuterium oxide, employed both as samples and as impurities in the cell gas, were used to investigate the origins of the polyatomic ions. It was found that no new species were formed in the cell as water from the plasma provides the basic reactive components; however, some were greatly enhanced when the cell gas was deliberately wetted. The reactivity of the water/deuterium oxide dominated the cell chemistry when an unreactive gas such as He was used, indicating a need for careful control of water content, but the effects were greatly reduced when a reactive gas such as hydrogen was also employed. It is concluded that water could be a useful reagent molecule, if its partial pressure can be adequately controlled. Seeking complete removal of water from the reagent gas is unnecessary as there is a baseline contribution from the plasma and, in any case, when reactive reagent gases are used its effect is minimal.
- 1 January 1997
- Published by Royal Society of Chemistry (RSC) in Analytical Communications
- Vol. 34 (9) , 237-239
Universal Calibration Strategy for Laser Ablation Inductively Coupled Plasma Mass Spectrometry Based on the Use of Aqueous Standards With Modified Absorption Coefficients
This paper describes a calibration strategy for laser ablation ICP-MS based on the use of aqueous standards with modified absorption coefficients. The design of the ablation system and standard operating conditions are described. Initial studies were performed to characterise the behaviour of the calibration standards. Validation of the calibration procedure was performed using certified NIST reference materials. Future work will involve application of the calibration procedure to the analysis of biological materials.
- 1 January 1997
- Published by Royal Society of Chemistry (RSC) in Analytical Communications
- Vol. 34 (9) , 237-239
Universal Calibration Strategy for Laser Ablation Inductively Coupled Plasma Mass Spectrometry Based on the Use of Aqueous Standards With Modified Absorption Coefficients
This paper describes a calibration strategy for laser ablation ICP-MS based on the use of aqueous standards with modified absorption coefficients. The design of the ablation system and standard operating conditions are described. Initial studies were performed to characterise the behaviour of the calibration standards. Validation of the calibration procedure was performed using certified NIST reference materials. Future work will involve application of the calibration procedure to the analysis of biological materials.