Prateek Bahl
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Prateek Bahl has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Charitha M. de Silva
University of New South Wales
11 shared publications - Shovon Bhattacharjee
Department of Applied Chemistry and Chemical Engineering, Noakhali Science and Technology University, Noakhali, Bangladesh
10 shared publications Abrar Ahmad Chughtai
School of Population Health, UNSW Sydney 3 , Kensington, NSW 2052
9 shared publications- Chandini Raina MacIntyre
Biosecurity Program, The Kirby Institute, UNSW Sydney, Sydney, NSW, Australia
9 shared publications - Con J. Doolan
University of New South Wales
8 shared publications Con Doolan
School of Mechanical & Manufacturing Engineering, University of New South Wales, Sydney, NSW 2052, Australia
4 shared publications
Latest Publications
- Open Access
- 24 April 2025
- Published by Elsevier in Building and Environment
- Vol. 279
An infection risk model for estimating infection probability and occupancy time: A CFD approach with aerosol measurements
- 24 April 2025
- Published by Elsevier in Building and Environment
- Vol. 279
Open AccessAn infection risk model for estimating infection probability and occupancy time: A CFD approach with aerosol measurements
- Open Access
- 1 October 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (10)
Experimental framework to examine turbulent puffs generated by human coughing
Respiratory infections spread through pathogen-laden droplets and aerosols exhaled by humans as part of turbulent puffs. Understanding the dynamics of these puffs is essential for assessing risks and implementing effective infection control measures. This study introduces an innovative experimental framework that employs neutrally buoyant helium-filled soap bubbles to visualize and quantitatively analyze puffs expelled during respiratory exhalations. This approach allows for the exploration of flow and turbulence statistics in exhalation puffs, an area that has not been previously examined. The experimental setup employs a high-speed camera coupled with light sheet illumination in a controlled environment. This framework can measure puff trajectory and radius directly from the raw images captured by the camera or from the velocity fields obtained through particle image velocimetry. The framework was subsequently applied to 15 coughs from three subjects. Our observations of maximum and mean velocities within the puff align with previous studies on droplet flow statistics. Additionally, based on the vorticity distribution of the exhalation, we observed a two-stage evolution of the puff with an initial jet-like phase where the trajectory scales with t1/2, followed by a puff-like phase with t1/4 scaling. Furthermore, we observed an entrainment coefficient (α) of 0.32 ± 0.06 for the initial jet-like phase and 0.17 ± 0.08 for the puff-like phase. Overall, this framework offers improved insight into the transport mechanisms of respiratory aerosols by enabling the quantification of different flow statistics of turbulent puffs.
- 1 October 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (10)
Open AccessExperimental framework to examine turbulent puffs generated by human coughing
Respiratory infections spread through pathogen-laden droplets and aerosols exhaled by humans as part of turbulent puffs. Understanding the dynamics of these puffs is essential for assessing risks and implementing effective infection control measures. This study introduces an innovative experimental framework that employs neutrally buoyant helium-filled soap bubbles to visualize and quantitatively analyze puffs expelled during respiratory exhalations. This approach allows for the exploration of flow and turbulence statistics in exhalation puffs, an area that has not been previously examined. The experimental setup employs a high-speed camera coupled with light sheet illumination in a controlled environment. This framework can measure puff trajectory and radius directly from the raw images captured by the camera or from the velocity fields obtained through particle image velocimetry. The framework was subsequently applied to 15 coughs from three subjects. Our observations of maximum and mean velocities within the puff align with previous studies on droplet flow statistics. Additionally, based on the vorticity distribution of the exhalation, we observed a two-stage evolution of the puff with an initial jet-like phase where the trajectory scales with t1/2, followed by a puff-like phase with t1/4 scaling. Furthermore, we observed an entrainment coefficient (α) of 0.32 ± 0.06 for the initial jet-like phase and 0.17 ± 0.08 for the puff-like phase. Overall, this framework offers improved insight into the transport mechanisms of respiratory aerosols by enabling the quantification of different flow statistics of turbulent puffs.
- Open Access
- 23 August 2023
- Published by IOP Publishing in Environmental Research: Health
- Vol. 1 (4) , 041001
Demonstrating the most effective interventions to improve classroom air quality. What novel in situ tests of real-world conditions show is still missing in our guidance
Over 20 years ago a report commissioned by the European Commission identified air quality in schools as a public health priority. Despite this concern, little action was taken in the following two decades. Over the last two years as classrooms were increasingly recognised as hotspots for the transmission of SARS-CoV-2, renewed interest and resources have been made available in response to this issue. Questions remain, however, over how best to achieve safer classroom air. Our analysis assessed a range of in situ interventions to remove particulate matter (PM2.5) and carbon dioxide from inside a populated classroom. Our approach used saline spray and volunteers’ exhalations as our source of PM2.5 and carbon dioxide to explore the ability of high efficiency particulate air (HEPA) filters, natural ventilation and a recirculating A/C unit to remove these air pollutants which collectively provided a novel set of data. For a total window opening of 1.86 m2 for a 181.7 m3 classroom with a HEPA filter with a 703m3/hr clean air delivery rate, our results confirmed that outdoor air was needed to purge the room to reduce carbon dioxide levels that otherwise rose to >1000 ppm in 12 min. Cross and natural ventilation reduced levels of PM2.5 and carbon dioxide very effectively—in under 5 and 10 min respectively during low levels of outside PM2.5. We conclude that natural ventilation supplemented with the use of HEPA filters is the most effective way to reliably improve indoor air quality year-round, balancing the need to have easy to enact approaches to reduce the buildup of PM2.5, airborne viruses and carbon dioxide. These results highlight an important knowledge gap. Without having localised real-time outdoor air pollution sensing, evidence-based decisions cannot be made about how often, and for how long, windows can safely remain open to purge classrooms in times of poor quality outdoor air.
- 23 August 2023
- Published by IOP Publishing in Environmental Research: Health
- Vol. 1 (4) , 041001
Open AccessDemonstrating the most effective interventions to improve classroom air quality. What novel in situ tests of real-world conditions show is still missing in our guidance
Over 20 years ago a report commissioned by the European Commission identified air quality in schools as a public health priority. Despite this concern, little action was taken in the following two decades. Over the last two years as classrooms were increasingly recognised as hotspots for the transmission of SARS-CoV-2, renewed interest and resources have been made available in response to this issue. Questions remain, however, over how best to achieve safer classroom air. Our analysis assessed a range of in situ interventions to remove particulate matter (PM2.5) and carbon dioxide from inside a populated classroom. Our approach used saline spray and volunteers’ exhalations as our source of PM2.5 and carbon dioxide to explore the ability of high efficiency particulate air (HEPA) filters, natural ventilation and a recirculating A/C unit to remove these air pollutants which collectively provided a novel set of data. For a total window opening of 1.86 m2 for a 181.7 m3 classroom with a HEPA filter with a 703m3/hr clean air delivery rate, our results confirmed that outdoor air was needed to purge the room to reduce carbon dioxide levels that otherwise rose to >1000 ppm in 12 min. Cross and natural ventilation reduced levels of PM2.5 and carbon dioxide very effectively—in under 5 and 10 min respectively during low levels of outside PM2.5. We conclude that natural ventilation supplemented with the use of HEPA filters is the most effective way to reliably improve indoor air quality year-round, balancing the need to have easy to enact approaches to reduce the buildup of PM2.5, airborne viruses and carbon dioxide. These results highlight an important knowledge gap. Without having localised real-time outdoor air pollution sensing, evidence-based decisions cannot be made about how often, and for how long, windows can safely remain open to purge classrooms in times of poor quality outdoor air.
- 9 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Photovoltaics
- Vol. 13 (5) , 743-749
Vortex Generators for Passive Cooling of Rooftop Photovoltaic Systems Under Free Convection
Decreasing the operating temperature of a photovoltaic (PV) module can increase its electrical output and longevity. This can be achieved by increasing the radiative and convective heat losses on the front or the rear module surface. In this article, we have proposed and investigated, experimentally and numerically, a passive cooling method for the rooftop PV system, which enhances convection heat flux on the module's rear surface. As the vortex generators (VGs) are attached on the surface of the roof without physical contact to the module backsheet, this technique would not void the module warranty and can be easily retrofitted on an existing rooftop system. In the absence of wind (free convection), the module is subjected to the highest temperatures, and our VG design specifically targets this worst-case scenario. Our results reveal a temperature reduction of more than 4 °C using VGs in the configuration studied. This can be translated to a significant increase in module lifespan by around 30% to 40%, thus reducing the levelized cost of electricity.
- 9 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Photovoltaics
- Vol. 13 (5) , 743-749
Vortex Generators for Passive Cooling of Rooftop Photovoltaic Systems Under Free Convection
Decreasing the operating temperature of a photovoltaic (PV) module can increase its electrical output and longevity. This can be achieved by increasing the radiative and convective heat losses on the front or the rear module surface. In this article, we have proposed and investigated, experimentally and numerically, a passive cooling method for the rooftop PV system, which enhances convection heat flux on the module's rear surface. As the vortex generators (VGs) are attached on the surface of the roof without physical contact to the module backsheet, this technique would not void the module warranty and can be easily retrofitted on an existing rooftop system. In the absence of wind (free convection), the module is subjected to the highest temperatures, and our VG design specifically targets this worst-case scenario. Our results reveal a temperature reduction of more than 4 °C using VGs in the configuration studied. This can be translated to a significant increase in module lifespan by around 30% to 40%, thus reducing the levelized cost of electricity.
- Open Access
- 18 June 2022
- Published by Wiley in Nano Select
- Vol. 3 (10) , 1355-1381
Face masks and respirators: Towards sustainable materials and technologies to overcome the shortcomings and challenges
The unprecedented threat of COVID‐19 and the likelihood of other emerging infectious diseases have accentuated the need for sustainable and effective masks and respirators (MAR). MAR assists in minimizing the risk of infection and controlling the spread of pathogens. However, during the COVID‐19 pandemic, there was a worldwide scarcity of MAR due to unprecedented global demand. There are also notable limitations in commonly used MAR, such as low filtration efficiency, poor fit, non‐reusability, physiological impact, lack of biocompatibility and non‐biodegradability, and inability to kill pathogens. Therefore, there remains an unmet need for a comprehensive study focusing on potential materials and new technologies for MAR. Here we outline a comprehensive overview of the limitations of conventional MAR followed by required potential solutions (such as using nanofibers/graphene base filters/metal‐organic framework as filter media, laser scanning and 3D printing for fit and seal, applying antimicrobial nanomaterials coating on filter media, using reusable and biodegradable materials, developing high‐performing cloth masks, improving hydrophobicity, etc.). The information on potential materials and new technologies of MAR and research evidence outlined here can inform further research and development of high‐performing and sustainable respiratory protection technologies to improve the health and safety of the first responders and the community.
- 18 June 2022
- Published by Wiley in Nano Select
- Vol. 3 (10) , 1355-1381
Open AccessFace masks and respirators: Towards sustainable materials and technologies to overcome the shortcomings and challenges
The unprecedented threat of COVID‐19 and the likelihood of other emerging infectious diseases have accentuated the need for sustainable and effective masks and respirators (MAR). MAR assists in minimizing the risk of infection and controlling the spread of pathogens. However, during the COVID‐19 pandemic, there was a worldwide scarcity of MAR due to unprecedented global demand. There are also notable limitations in commonly used MAR, such as low filtration efficiency, poor fit, non‐reusability, physiological impact, lack of biocompatibility and non‐biodegradability, and inability to kill pathogens. Therefore, there remains an unmet need for a comprehensive study focusing on potential materials and new technologies for MAR. Here we outline a comprehensive overview of the limitations of conventional MAR followed by required potential solutions (such as using nanofibers/graphene base filters/metal‐organic framework as filter media, laser scanning and 3D printing for fit and seal, applying antimicrobial nanomaterials coating on filter media, using reusable and biodegradable materials, developing high‐performing cloth masks, improving hydrophobicity, etc.). The information on potential materials and new technologies of MAR and research evidence outlined here can inform further research and development of high‐performing and sustainable respiratory protection technologies to improve the health and safety of the first responders and the community.
- Open Access
- 2 November 2021
- Published by AIP Publishing in Physics of Fluids
- Vol. 33 (11) , 111901
Flow dynamics of droplets expelled during sneezing
Respiratory infections transmit through droplets and aerosols generated by the infected individual during respiratory emissions. It is essential to study the flow dynamics of these emissions to develop strategies for mitigating the risk of infection. In particular, the dynamics of droplets expelled during violent exhalations such as sneezing is crucial, but has received little attention to date. Here, for the first time, we present the results of droplet dynamics of 35 sneezes, obtained from four volunteers, using particle tracking velocimetry experiments. Our results reveal a mean droplet velocity of 2–5.4 m/s across the different subjects. These values are significantly lower than what is usually assumed in the studies simulating or replicating sneezes. Furthermore, the large variation in droplet speeds, flow direction, spread angle, and head movement is also quantified. These findings will enable the refinement of models and simulations of sneezes toward improving infection control guidelines.
- 2 November 2021
- Published by AIP Publishing in Physics of Fluids
- Vol. 33 (11) , 111901
Open AccessFlow dynamics of droplets expelled during sneezing
Respiratory infections transmit through droplets and aerosols generated by the infected individual during respiratory emissions. It is essential to study the flow dynamics of these emissions to develop strategies for mitigating the risk of infection. In particular, the dynamics of droplets expelled during violent exhalations such as sneezing is crucial, but has received little attention to date. Here, for the first time, we present the results of droplet dynamics of 35 sneezes, obtained from four volunteers, using particle tracking velocimetry experiments. Our results reveal a mean droplet velocity of 2–5.4 m/s across the different subjects. These values are significantly lower than what is usually assumed in the studies simulating or replicating sneezes. Furthermore, the large variation in droplet speeds, flow direction, spread angle, and head movement is also quantified. These findings will enable the refinement of models and simulations of sneezes toward improving infection control guidelines.
- 6 September 2021
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 32 (12) , 125302
Bespoke flow experiments to capture the dynamics of coughs and sneezes
Here, we detail and analyse a set of tailored experiments to capture the flow dynamics of coughs and sneezes. Specifically, conventional particle tracking-based flow experiments are tailored to capture the wide range of spatial and temporal scales in the flow through the use of high-speed and high-resolution imaging systems. In doing so, we captured droplet velocities over a wide range of particle sizes with a large field-of-view in the order of a metre to capture the full flow field, which is challenging to achieve through conventional methods. A simultaneous direct measure of droplet sizing and velocity is also obtained through back-illuminated imaging experiments, albeit over a smaller spatial extent. A statistical assessment of the droplets’ flow-field reveals good agreement to prior works, now extending this over a much larger spatial extent. Through a statistical analysis of representative sneeze and cough samples, we highlight the potential of the presented experimental techniques to provide detailed flow dynamics. In particular, we observe that droplets are expelled over a significantly shorter period than the airflow generated in a cough; in contrast, droplets appear to be continuously expelled during the span of a sneeze. Furthermore, due to the lower momentum in coughs, droplets exhibit aerosolised behaviour at an earlier stage than sneezes, where the stronger flow-field expelled dictates the droplet dynamics through the bulk of the sneeze duration. These findings reveal crucial differences between coughs and sneezes, which are essential when modelling such flow accurately or designing pressure-driven simulators.
- 6 September 2021
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 32 (12) , 125302
Bespoke flow experiments to capture the dynamics of coughs and sneezes
Here, we detail and analyse a set of tailored experiments to capture the flow dynamics of coughs and sneezes. Specifically, conventional particle tracking-based flow experiments are tailored to capture the wide range of spatial and temporal scales in the flow through the use of high-speed and high-resolution imaging systems. In doing so, we captured droplet velocities over a wide range of particle sizes with a large field-of-view in the order of a metre to capture the full flow field, which is challenging to achieve through conventional methods. A simultaneous direct measure of droplet sizing and velocity is also obtained through back-illuminated imaging experiments, albeit over a smaller spatial extent. A statistical assessment of the droplets’ flow-field reveals good agreement to prior works, now extending this over a much larger spatial extent. Through a statistical analysis of representative sneeze and cough samples, we highlight the potential of the presented experimental techniques to provide detailed flow dynamics. In particular, we observe that droplets are expelled over a significantly shorter period than the airflow generated in a cough; in contrast, droplets appear to be continuously expelled during the span of a sneeze. Furthermore, due to the lower momentum in coughs, droplets exhibit aerosolised behaviour at an earlier stage than sneezes, where the stronger flow-field expelled dictates the droplet dynamics through the bulk of the sneeze duration. These findings reveal crucial differences between coughs and sneezes, which are essential when modelling such flow accurately or designing pressure-driven simulators.
- Open Access
- 1 August 2021
- Published by Paul V. Galvin Library/Illinois Institute of Technology in 14th International Symposium on Particle Image Velocimetry
- Vol. 1 (1)
Towards capturing a database of respiratory exhalations from flow visualisations
One of the most common modes of infection transmission is through pathogen laden droplets expelled during natural human respiratory exhalations such as speaking, coughing, and sneezing. Infection control guidelines for the prevention of respiratory infection make assumptions about two key parameters: the safe distance between an infected and healthy individual and the size of large and small droplets (Bahl et al., 2020). Studies in the past have utilised flow visualisation techniques to understand the dynamics of respiratory flows but most of them provide only qualitative data on respiratory droplets and do not provide sufficient detail to estimate accurate flow velocities (Bourouiba et al., 2014; Vansciver et al., 2011; Scharfman et al., 2016). One of the reasons this remains a demanding application is the vast range of droplet sizes that are expelled at various velocities. Here, we present an experimental framework using particle tracking to understand the flow dynamics of the expelled droplets. Three different illumination techniques were used to capture high-speed frames of different exhalations (see figure 1). The high density of droplets in case of sneezing lead to overlap of droplet trajectories with volume illumination approach, which was resolved using tailored optics to illuminate only a slice of sneeze flow. Thereafter, the image processing techniques required for precise PTV were refined to examine droplet dynamics of various exhalations (see figure 2). The techniques were applied to multiple cases of respiratory exhalations to understand subject to subject variability. The results for sneezing revealed a mean droplet velocity of 2 m/s to 5.4 m/s across different subjects. Additionally, less than 1% of droplets were expelled at velocities greater than 10 m/s and almost 80% of were expelled at velocities less than 5 m/s. These values were substantially lower than the values usually assumed in studies modelling or replicating sneezes (Xie et al., 2007; Atkinson and Wein, 2008). The results also revealed a high variation in the droplet dynamics, even among the sneezes from the same subject. Flow direction, spread angle, and head movement were also quantified, and the results reveal substantial variation between the subjects. In the case of coughing, maximum droplet velocities observed were in the range of 10−15 m/s however, these high velocities were detected only during the initial 0.05 s. This work addresses the critical gaps in the understanding of the respiratory transmission of infection by providing valuable data on the droplet dynamics of various exhalations, on which the experimental data was very limited in the existing literature. Furthermore, this data will aid in numerical modelling of respiratory flows, particularly for sneezes, as studies to date rely only on airflow data of the exhalations.
- 1 August 2021
- Published by Paul V. Galvin Library/Illinois Institute of Technology in 14th International Symposium on Particle Image Velocimetry
- Vol. 1 (1)
Open AccessTowards capturing a database of respiratory exhalations from flow visualisations
One of the most common modes of infection transmission is through pathogen laden droplets expelled during natural human respiratory exhalations such as speaking, coughing, and sneezing. Infection control guidelines for the prevention of respiratory infection make assumptions about two key parameters: the safe distance between an infected and healthy individual and the size of large and small droplets (Bahl et al., 2020). Studies in the past have utilised flow visualisation techniques to understand the dynamics of respiratory flows but most of them provide only qualitative data on respiratory droplets and do not provide sufficient detail to estimate accurate flow velocities (Bourouiba et al., 2014; Vansciver et al., 2011; Scharfman et al., 2016). One of the reasons this remains a demanding application is the vast range of droplet sizes that are expelled at various velocities. Here, we present an experimental framework using particle tracking to understand the flow dynamics of the expelled droplets. Three different illumination techniques were used to capture high-speed frames of different exhalations (see figure 1). The high density of droplets in case of sneezing lead to overlap of droplet trajectories with volume illumination approach, which was resolved using tailored optics to illuminate only a slice of sneeze flow. Thereafter, the image processing techniques required for precise PTV were refined to examine droplet dynamics of various exhalations (see figure 2). The techniques were applied to multiple cases of respiratory exhalations to understand subject to subject variability. The results for sneezing revealed a mean droplet velocity of 2 m/s to 5.4 m/s across different subjects. Additionally, less than 1% of droplets were expelled at velocities greater than 10 m/s and almost 80% of were expelled at velocities less than 5 m/s. These values were substantially lower than the values usually assumed in studies modelling or replicating sneezes (Xie et al., 2007; Atkinson and Wein, 2008). The results also revealed a high variation in the droplet dynamics, even among the sneezes from the same subject. Flow direction, spread angle, and head movement were also quantified, and the results reveal substantial variation between the subjects. In the case of coughing, maximum droplet velocities observed were in the range of 10−15 m/s however, these high velocities were detected only during the initial 0.05 s. This work addresses the critical gaps in the understanding of the respiratory transmission of infection by providing valuable data on the droplet dynamics of various exhalations, on which the experimental data was very limited in the existing literature. Furthermore, this data will aid in numerical modelling of respiratory flows, particularly for sneezes, as studies to date rely only on airflow data of the exhalations.
- Open Access
- 21 May 2021
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 7 (6) , 2791-2802
Experimental Evidence for the Optimal Design of a High-Performing Cloth Mask
Cloth masks can be an alternative to medical masks during pandemics. Recent studies have examined the performance of fabrics under various conditions; however, the performance against violent respiratory events such as human sneezes is yet to be explored. Accordingly, we present a comprehensive experimental study using sneezes by a healthy adult and a tailored image-based flow measurement diagnostic system evaluating all dimensions of protection of commonly available fabrics and their layered combinations: the respiratory droplet blocking efficiency, water resistance, and breathing resistance. Our results reveal that a well-designed cloth mask can outperform a three-layered surgical mask for such violent respiratory events. Specifically, increasing the number of layers significantly increases the droplet blocking efficiency, on average by ∼20 times per additional fabric layer. A minimum of three layers is necessary to resemble the droplet blocking performance of surgical masks, and a combination of cotton/linen (hydrophilic inner layer)–blends (middle layer)–polyester/nylon (hydrophobic outer layer) exhibited the best performance among overall indicators tested. In an optimum three-layered design, the average thread count should be greater than 200, and the porosity should be less than 2%. Furthermore, machine washing at 60 °C did not significantly impact the performance of cloth masks. These findings inform the design of high-performing homemade cloth masks.
- 21 May 2021
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 7 (6) , 2791-2802
Open AccessExperimental Evidence for the Optimal Design of a High-Performing Cloth Mask
Cloth masks can be an alternative to medical masks during pandemics. Recent studies have examined the performance of fabrics under various conditions; however, the performance against violent respiratory events such as human sneezes is yet to be explored. Accordingly, we present a comprehensive experimental study using sneezes by a healthy adult and a tailored image-based flow measurement diagnostic system evaluating all dimensions of protection of commonly available fabrics and their layered combinations: the respiratory droplet blocking efficiency, water resistance, and breathing resistance. Our results reveal that a well-designed cloth mask can outperform a three-layered surgical mask for such violent respiratory events. Specifically, increasing the number of layers significantly increases the droplet blocking efficiency, on average by ∼20 times per additional fabric layer. A minimum of three layers is necessary to resemble the droplet blocking performance of surgical masks, and a combination of cotton/linen (hydrophilic inner layer)–blends (middle layer)–polyester/nylon (hydrophobic outer layer) exhibited the best performance among overall indicators tested. In an optimum three-layered design, the average thread count should be greater than 200, and the porosity should be less than 2%. Furthermore, machine washing at 60 °C did not significantly impact the performance of cloth masks. These findings inform the design of high-performing homemade cloth masks.
- Open Access
- 10 September 2020
- Published by BMJ in BMJ Open Respiratory Research
- Vol. 7 (1) , e000698
Last-resort strategies during mask shortages: optimal design features of cloth masks and decontamination of disposable masks during the COVID-19 pandemic
Face masks and respirators are the most widely used intervention measures for respiratory protection. In the wake of COVID-19, in response to shortages and lack of availability of surgical masks and respirators, the use of cloth masks has become a research focus. Various fabrics have been promoted with little evidence-based foundation and without guidelines on design principles for optimal performance. In these circumstances, it is essential to understand the properties, key performance factors, filter mechanisms and evidence on cloth masks materials. The general community might also need to decontaminate and reuse disposable, single-use devices as a last resort. We present an overview of the filter materials, filter mechanisms and effectiveness, key performance factors, and hydrophobicity of the common disposable masks, as well as cloth masks. We also reviewed decontamination methods for disposable respiratory devices. As an alternative to surgical masks and respirators, we recommend a cloth mask made of at least three layers (300–350 threads per inch) and adding a nylon stocking layer over the mask for a better fit. Water-resistant fabrics (polyesters/nylon), blends of fabrics and water-absorbing fabrics (cotton) should be in the outside layer, middle layer/layers and inside layer, respectively. The information outlined here will help people to navigate their choices if facing shortages of appropriate respiratory protection during the COVID-19 pandemic.
- 10 September 2020
- Published by BMJ in BMJ Open Respiratory Research
- Vol. 7 (1) , e000698
Open AccessLast-resort strategies during mask shortages: optimal design features of cloth masks and decontamination of disposable masks during the COVID-19 pandemic
Face masks and respirators are the most widely used intervention measures for respiratory protection. In the wake of COVID-19, in response to shortages and lack of availability of surgical masks and respirators, the use of cloth masks has become a research focus. Various fabrics have been promoted with little evidence-based foundation and without guidelines on design principles for optimal performance. In these circumstances, it is essential to understand the properties, key performance factors, filter mechanisms and evidence on cloth masks materials. The general community might also need to decontaminate and reuse disposable, single-use devices as a last resort. We present an overview of the filter materials, filter mechanisms and effectiveness, key performance factors, and hydrophobicity of the common disposable masks, as well as cloth masks. We also reviewed decontamination methods for disposable respiratory devices. As an alternative to surgical masks and respirators, we recommend a cloth mask made of at least three layers (300–350 threads per inch) and adding a nylon stocking layer over the mask for a better fit. Water-resistant fabrics (polyesters/nylon), blends of fabrics and water-absorbing fabrics (cotton) should be in the outside layer, middle layer/layers and inside layer, respectively. The information outlined here will help people to navigate their choices if facing shortages of appropriate respiratory protection during the COVID-19 pandemic.