Shijun Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Shijun Wu has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Canjun Yang
Department of Mechanical Engineering, Zhejiang University, Hangzhou, China
10 shared publications Canjun Yang
7 shared publications- Feng Zhang
State Key Laboratory of Fluid Power & Mechatronic Systems, Zhejiang University, Hangzhou 310027, China
3 shared publications Xun Wang
Zhejiang University
3 shared publicationsZhiheng Chen
3 shared publications- Bo Jin
State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou 310027, China
2 shared publications
Latest Publications
- Open Access
- 11 August 2026
- Published by Elsevier in Results in Engineering
- Vol. 32
Design, analysis and optimization of a high-load cylindrical cam–tapered roller transmission mechanism considering coupled shaft bending and contact deformation
- 11 August 2026
- Published by Elsevier in Results in Engineering
- Vol. 32
Open AccessDesign, analysis and optimization of a high-load cylindrical cam–tapered roller transmission mechanism considering coupled shaft bending and contact deformation
- 1 July 2026
- Published by Springer Nature in Acta Oceanologica Sinica
- Vol. 45 (7) , 158-168
Design and application of expandable modular deep-sea pressure-retaining fluid sampler
- 1 July 2026
- Published by Springer Nature in Acta Oceanologica Sinica
- Vol. 45 (7) , 158-168
Design and application of expandable modular deep-sea pressure-retaining fluid sampler
- Open Access
- 23 May 2026
- Published by Elsevier in Applied Ocean Research
- Vol. 172
A combined prediction model for depth-averaged current velocities of hybrid underwater profilers based on time series analysis
- 23 May 2026
- Published by Elsevier in Applied Ocean Research
- Vol. 172
Open AccessA combined prediction model for depth-averaged current velocities of hybrid underwater profilers based on time series analysis
- 23 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Oceanic Engineering
- Vol. 50 (4) , 2456-2467
Active Pressure-Compensation Technology for Deep-Sea Fluid Samplers
Decompression presents a significant challenge in ensuring the reliability of deep-sea samples. To address this issue, the current study introduces a precise active pressure-compensation technology adaptable to diverse deep-sea fluid samplers. Leveraging this technology, an active pressure compensator is also developed. The flow rate required to maintain pressure during sample recovery is determined through theoretical calculations. Based on this flow requirement, a cam piston pump—the most important component of the compensator—is designed. Furthermore, a control circuit is devised for the active pressure compensator to regulate pressure during sample recovery. Laboratory experiments verify the flow output performance and mechanical efficiency of the cam piston pump at 60 MPa. Subsequently, a pressure-maintaining sampler is constructed and tested within an extra-high pressure test chamber. Preliminary results indicate that at depths of up to 6000 m, the proposed active pressure-compensation technology can maintain sample pressures at over 99% of their in situ pressures, thereby enhancing sample quality.
- 23 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Oceanic Engineering
- Vol. 50 (4) , 2456-2467
Active Pressure-Compensation Technology for Deep-Sea Fluid Samplers
Decompression presents a significant challenge in ensuring the reliability of deep-sea samples. To address this issue, the current study introduces a precise active pressure-compensation technology adaptable to diverse deep-sea fluid samplers. Leveraging this technology, an active pressure compensator is also developed. The flow rate required to maintain pressure during sample recovery is determined through theoretical calculations. Based on this flow requirement, a cam piston pump—the most important component of the compensator—is designed. Furthermore, a control circuit is devised for the active pressure compensator to regulate pressure during sample recovery. Laboratory experiments verify the flow output performance and mechanical efficiency of the cam piston pump at 60 MPa. Subsequently, a pressure-maintaining sampler is constructed and tested within an extra-high pressure test chamber. Preliminary results indicate that at depths of up to 6000 m, the proposed active pressure-compensation technology can maintain sample pressures at over 99% of their in situ pressures, thereby enhancing sample quality.
- Open Access
- 8 August 2024
- Published by MDPI AG in Chemosensors
- Vol. 12 (8) , 158
Review of Underwater In Situ Voltammetry Analyzers for Trace Metals
This review is a comprehensive overview of recent advancements in underwater in situ heavy metal voltammetric analyzers (UIHVAs). It explores various types of in situ voltammetric analyzers, including the voltammetric in situ profiling system, submersible integrated multi-channel trace metal sensing probes, vibrating gold microwire electrode voltammetric analyzers, and electrochemical analyzers designed for on-site flow measurements. It also covers electrochemical sensors based on flexible liquid crystal polymers, deep-sea mercury sensors, and other in situ electrochemical analyzers. This review systematically examines the research and development progress of microelectrode arrays, screen-printed, carbon, bismuth, antimony, and lab-on-a-chip electrodes. The final section looks at key trends in the research and development of voltammetric analyzers, highlighting the exploration of novel working electrodes, the integration of smart monitoring and data analysis technologies, and the promotion of interdisciplinary collaboration and innovation. From a global perspective, in situ heavy metal voltammetric analysis technology has demonstrated significant applicability in various fields, such as environmental monitoring, marine science, and biogeochemistry. This technology holds considerable potential for further development. However, extensive research and continuous improvement are required to improve detection performance. We are convinced that with continued technological advances and dedicated research efforts, these challenges can be overcome and will pave the way for the widespread application of UIHVAs.
- 8 August 2024
- Published by MDPI AG in Chemosensors
- Vol. 12 (8) , 158
Open AccessReview of Underwater In Situ Voltammetry Analyzers for Trace Metals
This review is a comprehensive overview of recent advancements in underwater in situ heavy metal voltammetric analyzers (UIHVAs). It explores various types of in situ voltammetric analyzers, including the voltammetric in situ profiling system, submersible integrated multi-channel trace metal sensing probes, vibrating gold microwire electrode voltammetric analyzers, and electrochemical analyzers designed for on-site flow measurements. It also covers electrochemical sensors based on flexible liquid crystal polymers, deep-sea mercury sensors, and other in situ electrochemical analyzers. This review systematically examines the research and development progress of microelectrode arrays, screen-printed, carbon, bismuth, antimony, and lab-on-a-chip electrodes. The final section looks at key trends in the research and development of voltammetric analyzers, highlighting the exploration of novel working electrodes, the integration of smart monitoring and data analysis technologies, and the promotion of interdisciplinary collaboration and innovation. From a global perspective, in situ heavy metal voltammetric analysis technology has demonstrated significant applicability in various fields, such as environmental monitoring, marine science, and biogeochemistry. This technology holds considerable potential for further development. However, extensive research and continuous improvement are required to improve detection performance. We are convinced that with continued technological advances and dedicated research efforts, these challenges can be overcome and will pave the way for the widespread application of UIHVAs.
- Open Access
- 28 March 2024
- Published by MDPI AG in Chemosensors
- Vol. 12 (4) , 51
Improved Microelectrode Array Electrode Design for Heavy Metal Detection
Traditional working electrodes are not sufficient to realize the low detection limit and wide detection range necessary for the detection of heavy metals. In this study, a microelectrode array electrode was proposed using a design scheme based on microelectromechanical systems that was optimized with finite element software. The working electrode adopted an innovative composite structure to realize the integrated design of the working and counter electrodes, which improved the system integration. Performance tests showed that the electrode realized the quantitative analysis of Cd(II), Pb(II), and Cu(II) with a low detection limit (0.1 μg/L) and a wide detection range (0.1–3000 μg/L). The electrode successfully measured the lead and copper ion concentrations in the Sanya River, including both seawater and freshwater environments. The experimental results demonstrate that the electrode exhibits excellent adaptability to environmental conditions and can be potentially applied for technical support in environmental monitoring and sewage treatment.
- 28 March 2024
- Published by MDPI AG in Chemosensors
- Vol. 12 (4) , 51
Open AccessImproved Microelectrode Array Electrode Design for Heavy Metal Detection
Traditional working electrodes are not sufficient to realize the low detection limit and wide detection range necessary for the detection of heavy metals. In this study, a microelectrode array electrode was proposed using a design scheme based on microelectromechanical systems that was optimized with finite element software. The working electrode adopted an innovative composite structure to realize the integrated design of the working and counter electrodes, which improved the system integration. Performance tests showed that the electrode realized the quantitative analysis of Cd(II), Pb(II), and Cu(II) with a low detection limit (0.1 μg/L) and a wide detection range (0.1–3000 μg/L). The electrode successfully measured the lead and copper ion concentrations in the Sanya River, including both seawater and freshwater environments. The experimental results demonstrate that the electrode exhibits excellent adaptability to environmental conditions and can be potentially applied for technical support in environmental monitoring and sewage treatment.
- 13 October 2023
- Published by Springer Nature
- p. 293-303
Design of an Autonomous Underwater Vehicle for Targeted Water Sampling
- 13 October 2023
- Published by Springer Nature
- p. 293-303
Design of an Autonomous Underwater Vehicle for Targeted Water Sampling
- Open Access
- 1 September 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (9)
Battery-free temperature logger for deep-sea hydrothermal fluids based on heat pipe heat exchangers and thermoelectric generators
Long-term in situ measurements of the temperature of hydrothermal fluids have great significance in the research of seafloor hydrothermal activities. Herein, we developed a self-powered battery-free temperature logger for measuring and recording the temperature of hydrothermal fluids. A gravity heat pipe made of titanium alloy was employed as the heat-conducting element of the temperature logger to capture heat from a hydrothermal vent and transfer it to the thermoelectric unit. The thermoelectric generator used herein converted the temperature difference into electrical energy to power the circuit of the temperature logger. Numerical analyses and experiments were performed to investigate the performance of the heat pipe and temperature logger. Results show that the temperature logger can realize self-powered starting at a temperature of >76 °C during a tank test. This paper presents a discussion on a new instrument for temperature measurements of deep-sea hydrothermal fluids.
- 1 September 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (9)
Open AccessBattery-free temperature logger for deep-sea hydrothermal fluids based on heat pipe heat exchangers and thermoelectric generators
Long-term in situ measurements of the temperature of hydrothermal fluids have great significance in the research of seafloor hydrothermal activities. Herein, we developed a self-powered battery-free temperature logger for measuring and recording the temperature of hydrothermal fluids. A gravity heat pipe made of titanium alloy was employed as the heat-conducting element of the temperature logger to capture heat from a hydrothermal vent and transfer it to the thermoelectric unit. The thermoelectric generator used herein converted the temperature difference into electrical energy to power the circuit of the temperature logger. Numerical analyses and experiments were performed to investigate the performance of the heat pipe and temperature logger. Results show that the temperature logger can realize self-powered starting at a temperature of >76 °C during a tank test. This paper presents a discussion on a new instrument for temperature measurements of deep-sea hydrothermal fluids.
- Open Access
- 7 May 2023
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 11 (5) , 994
Multiphysics Co-Simulation and Experimental Study of Deep-Sea Hydrothermal Energy Generation System
With the continuous deepening of research on seafloor hydrothermal observations, the demand for a sustainable power supply of observation equipment is increasingly urgent. A kind of device that utilizes the temperature difference near hydrothermal vents to provide power is studied. However, the frequent experiments required for in-depth research on this device contradict the rare opportunities for hydrothermal field experiments and the difficulty in laboratory replication. In response to the above difficulties, a multiphysics co-simulation of the deep-sea hydrothermal energy generation system is studied in this paper. Firstly, the output performance analysis and modeling of the TEG installed in the device under pressure are carried out. An enhanced heat transfer model of the system is proposed for the hydrothermal fluids in the flow channel of the device. Then, the thermoelectric model of TEG and the heat transfer model of the device are jointly simulated by using Fluent and Simulink software. Eventually, the simulation data are compared with the data obtained through experiments. The average absolute of the relative error of the open-circuit voltage is 5.07%, and the maximum one is 6.28%. The corresponding values of the maximum output power are 5.16% and 6.79%, respectively. Therefore, the performance of the hydrothermal thermoelectric power generation system and the correctness of the proposed overall co-simulation model are verified.
- 7 May 2023
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 11 (5) , 994
Open AccessMultiphysics Co-Simulation and Experimental Study of Deep-Sea Hydrothermal Energy Generation System
With the continuous deepening of research on seafloor hydrothermal observations, the demand for a sustainable power supply of observation equipment is increasingly urgent. A kind of device that utilizes the temperature difference near hydrothermal vents to provide power is studied. However, the frequent experiments required for in-depth research on this device contradict the rare opportunities for hydrothermal field experiments and the difficulty in laboratory replication. In response to the above difficulties, a multiphysics co-simulation of the deep-sea hydrothermal energy generation system is studied in this paper. Firstly, the output performance analysis and modeling of the TEG installed in the device under pressure are carried out. An enhanced heat transfer model of the system is proposed for the hydrothermal fluids in the flow channel of the device. Then, the thermoelectric model of TEG and the heat transfer model of the device are jointly simulated by using Fluent and Simulink software. Eventually, the simulation data are compared with the data obtained through experiments. The average absolute of the relative error of the open-circuit voltage is 5.07%, and the maximum one is 6.28%. The corresponding values of the maximum output power are 5.16% and 6.79%, respectively. Therefore, the performance of the hydrothermal thermoelectric power generation system and the correctness of the proposed overall co-simulation model are verified.