Andrés Oyarzún
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Andrés Oyarzún has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Luis Bahamonde
Department of Orthopaedics and Traumatology, Hospital Clínico Mutual de Seguridad, Lower Extremities Trauma Unit Staff, Santiago, Chile
3 shared publications - Álvaro Igor Zamorano
Mutual de Seguridad Clinical Hospital
3 shared publications - Carlos Felipe Albarrán
Orthopaedic Surgery, Hospital Clínico Universidad de Chile, Santiago, Chile
2 shared publications - Ignacio A. Rivera
Department of Orthopaedics and Traumatology Universidad de Chile, Postgraduate School, Resident, Santiago, Chile
2 shared publications J Tomás Muñoz
Faculty of Medicine, Universidad de Los Andes, Santiago, Chile
2 shared publications- J. Tomás Rojas
Shoulder, Elbow and Orthopaedic Sports Medicine, Sonnenhof Orthopaedics, Bern, Switzerland; Department of Orthopaedics and Trauma Surgery, Hospital San José-Clínica Santa María, Santiago, Chile
2 shared publications
Latest Publications
- Open Access
- 1 October 2025
- Published by Wolters Kluwer Health in OTA International
- Vol. 8 (6S)
Soft tissue coverage before 12 days prevents fracture-related infection in IIIB open tibial fractures in young and healthy patients
Introduction: Gustilo–Anderson type IIIB open tibial fractures carry a high risk of fracture-related infection (FRI) due to extensive soft tissue damage and frequent delays in coverage. Although early orthoplastic intervention lowers infection rates, many trauma centers lack the resources for same-day or early flap coverage. This study aimed to assess the relationship between timing of flap coverage and FRI risk in a young, healthy population, and to define a clinically relevant therapeutic window. Materials and Methods: A retrospective cohort study was conducted at a single Level I trauma center (2012–2023). Patients with GA IIIB tibial fractures were treated under a standardized protocol with strict inclusion criteria. Timing of flap coverage was analyzed using Levene test, Student t test, and ROC curve analysis with the Youden index to determine the optimal infection-risk threshold. Results: Out of 332 open tibial fractures, 41 patients with GA IIIB injuries met inclusion criteria. Mean time to coverage was 24.6 days. FRI occurred in 15 patients (36.6%). Delayed coverage was significantly associated with FRI ( P < 0.001). ROC analysis showed an AUC of 0.83; the Youden index identified P < 0.05). Conclusions: Coverage within 12 days minimizes infection risk in GA IIIB tibial fractures. Although immediate coverage remains ideal, a defined 12-day window offers practical guidance, especially where early orthoplastic care is not feasible.
- 1 October 2025
- Published by Wolters Kluwer Health in OTA International
- Vol. 8 (6S)
Open AccessSoft tissue coverage before 12 days prevents fracture-related infection in IIIB open tibial fractures in young and healthy patients
Introduction: Gustilo–Anderson type IIIB open tibial fractures carry a high risk of fracture-related infection (FRI) due to extensive soft tissue damage and frequent delays in coverage. Although early orthoplastic intervention lowers infection rates, many trauma centers lack the resources for same-day or early flap coverage. This study aimed to assess the relationship between timing of flap coverage and FRI risk in a young, healthy population, and to define a clinically relevant therapeutic window. Materials and Methods: A retrospective cohort study was conducted at a single Level I trauma center (2012–2023). Patients with GA IIIB tibial fractures were treated under a standardized protocol with strict inclusion criteria. Timing of flap coverage was analyzed using Levene test, Student t test, and ROC curve analysis with the Youden index to determine the optimal infection-risk threshold. Results: Out of 332 open tibial fractures, 41 patients with GA IIIB injuries met inclusion criteria. Mean time to coverage was 24.6 days. FRI occurred in 15 patients (36.6%). Delayed coverage was significantly associated with FRI ( P < 0.001). ROC analysis showed an AUC of 0.83; the Youden index identified P < 0.05). Conclusions: Coverage within 12 days minimizes infection risk in GA IIIB tibial fractures. Although immediate coverage remains ideal, a defined 12-day window offers practical guidance, especially where early orthoplastic care is not feasible.
- Open Access
- 22 May 2025
- Published by MDPI AG in Antibiotics
- Vol. 14 (6) , 532
Two-Year Follow-Up Shows Gentamicin-Coated Tibial Nails Reduce Infection Rates in Open Tibial Fractures
Introduction: Open tibial fractures carry a high risk of fracture-related infection (FRI), and prevention typically relies on early antibiotics and debridement. However, achieving optimum local antibiotic concentration remains challenging. Gentamicin-coated intramedullary nails (GCN) have been developed to prevent biofilm formation, showing short-term efficacy without interfering with fracture healing. Medium- and long-term data on GCN use are limited. This study aimed to assess the effectiveness and safety of GCN in medium-term follow-up. Methods: A prospective cohort study of patients with open tibial fractures was treated with GCN under a standardized protocol, with a minimum follow-up of 24 months. Patients with traumatic amputations, protocol infringement, or loss of follow-up were excluded. The analysis assessed overall FRI incidence by Gustilo–Anderson (GA) classification. Results: Of 907 patients, 139 were included, with 2 lost to follow-up. The overall FRI incidence was 8.8%, the average healing time was 34.3 weeks, and the non-union rate was 2.2%. FRI incidence by GA classification was 0% in GA I, 2.9% in GA II, 2.9% in GA IIIA, 44.4% in GA IIIB, and 33.3% in GA IIIC. External fixation (EF) was required in 45.2% of cases, with 16.1% developing FRI (14.3% in GA II, 2.8% in GA IIIA, 50% in GA IIIB, and 33.3% in GA IIIC). In non-EF cases, FRI occurred in 2.7% of patients (2.9% in GA IIIA and 25% in GA IIIB). No adverse effects were reported due to locally administered gentamicin. Conclusions: In the medium term, GCN has consistently demonstrated safety and efficacy in preventing FRI in open tibial fractures, particularly in GA IIIA cases, even with the use of temporary EF. These findings highlight its potential as a valuable tool in managing open tibial fractures. However, further studies with long-term outcomes are needed to evaluate its effectiveness in GA IIIB and IIIC fractures.
- 22 May 2025
- Published by MDPI AG in Antibiotics
- Vol. 14 (6) , 532
Open AccessTwo-Year Follow-Up Shows Gentamicin-Coated Tibial Nails Reduce Infection Rates in Open Tibial Fractures
Introduction: Open tibial fractures carry a high risk of fracture-related infection (FRI), and prevention typically relies on early antibiotics and debridement. However, achieving optimum local antibiotic concentration remains challenging. Gentamicin-coated intramedullary nails (GCN) have been developed to prevent biofilm formation, showing short-term efficacy without interfering with fracture healing. Medium- and long-term data on GCN use are limited. This study aimed to assess the effectiveness and safety of GCN in medium-term follow-up. Methods: A prospective cohort study of patients with open tibial fractures was treated with GCN under a standardized protocol, with a minimum follow-up of 24 months. Patients with traumatic amputations, protocol infringement, or loss of follow-up were excluded. The analysis assessed overall FRI incidence by Gustilo–Anderson (GA) classification. Results: Of 907 patients, 139 were included, with 2 lost to follow-up. The overall FRI incidence was 8.8%, the average healing time was 34.3 weeks, and the non-union rate was 2.2%. FRI incidence by GA classification was 0% in GA I, 2.9% in GA II, 2.9% in GA IIIA, 44.4% in GA IIIB, and 33.3% in GA IIIC. External fixation (EF) was required in 45.2% of cases, with 16.1% developing FRI (14.3% in GA II, 2.8% in GA IIIA, 50% in GA IIIB, and 33.3% in GA IIIC). In non-EF cases, FRI occurred in 2.7% of patients (2.9% in GA IIIA and 25% in GA IIIB). No adverse effects were reported due to locally administered gentamicin. Conclusions: In the medium term, GCN has consistently demonstrated safety and efficacy in preventing FRI in open tibial fractures, particularly in GA IIIA cases, even with the use of temporary EF. These findings highlight its potential as a valuable tool in managing open tibial fractures. However, further studies with long-term outcomes are needed to evaluate its effectiveness in GA IIIB and IIIC fractures.
- Open Access
- 1 June 2023
- Published by Korean Shoulder and Elbow Society in Clinics in Shoulder and Elbow
- Vol. 26 (2) , 140-147
Anatomic coracoclavicular ligament reconstruction with triple flip-buttons leads to good functional outcomes and low reduction loss: a case series
Background: The management of acromioclavicular (AC) joint dislocation remains controversial. Recently, anatomic coracoclavicular (CC) fixation with a double clavicular tunnel and three flip-buttons has shown promising results. This study aimed to evaluate functional and radiological outcomes in patients with high-grade AC joint dislocation treated with anatomic CC fixation using double clavicular tunnels and three flip-buttons. Methods: A retrospective, unicentric study was performed. The study included patients with high-grade AC joint dislocation who underwent surgery with anatomic CC fixation using double clavicular tunnels and three flip-buttons. Demographic data were obtained from medical records. A functional evaluation using subjective shoulder value (SSV), visual analog scale (VAS), and disabilities of the arm, shoulder, and hand (DASH) questionnaires was performed, and an evaluation of preoperative and postoperative comparative Zanca view images was performed. Factors associated with functional outcomes and radiological AC reduction were analyzed. Results: A total of 83 patients completed follow-up and were included in the analysis. The mean SSV, VAS, and DASH scores were 92.8, 0.8, and 6.4, respectively. Patients who had complications experienced significantly worse functional outcomes (DASH: P=0.037). Suboptimal final AC reduction was observed in nine patients (11.1%), and significantly more frequently in patients older than 40 years (P=0.031) and in surgeries performed more than 7 days after injury (P=0.034). There were two reoperations (2.4%). Conclusions: Anatomic CC fixation with a double clavicular tunnel and three flip-buttons leads to good functional outcomes, low complication rates, and high rates of optimal AC reduction. Level of Evidence: Level IV; Case series.
- 1 June 2023
- Published by Korean Shoulder and Elbow Society in Clinics in Shoulder and Elbow
- Vol. 26 (2) , 140-147
Open AccessAnatomic coracoclavicular ligament reconstruction with triple flip-buttons leads to good functional outcomes and low reduction loss: a case series
Background: The management of acromioclavicular (AC) joint dislocation remains controversial. Recently, anatomic coracoclavicular (CC) fixation with a double clavicular tunnel and three flip-buttons has shown promising results. This study aimed to evaluate functional and radiological outcomes in patients with high-grade AC joint dislocation treated with anatomic CC fixation using double clavicular tunnels and three flip-buttons. Methods: A retrospective, unicentric study was performed. The study included patients with high-grade AC joint dislocation who underwent surgery with anatomic CC fixation using double clavicular tunnels and three flip-buttons. Demographic data were obtained from medical records. A functional evaluation using subjective shoulder value (SSV), visual analog scale (VAS), and disabilities of the arm, shoulder, and hand (DASH) questionnaires was performed, and an evaluation of preoperative and postoperative comparative Zanca view images was performed. Factors associated with functional outcomes and radiological AC reduction were analyzed. Results: A total of 83 patients completed follow-up and were included in the analysis. The mean SSV, VAS, and DASH scores were 92.8, 0.8, and 6.4, respectively. Patients who had complications experienced significantly worse functional outcomes (DASH: P=0.037). Suboptimal final AC reduction was observed in nine patients (11.1%), and significantly more frequently in patients older than 40 years (P=0.031) and in surgeries performed more than 7 days after injury (P=0.034). There were two reoperations (2.4%). Conclusions: Anatomic CC fixation with a double clavicular tunnel and three flip-buttons leads to good functional outcomes, low complication rates, and high rates of optimal AC reduction. Level of Evidence: Level IV; Case series.
- 25 April 2023
- Published by SAGE Publications in Shoulder & Elbow
- Vol. 16 (3) , 265-273
Medial placement of trapezoid tunnel leads to higher reduction loss in acute acromioclavicular joint dislocation treated with anatomic coracoclavicular fixation
Aim: To analyze the association between clavicular tunnel positioning and postoperative reduction loss in patients with acute acromioclavicular (AC) joint dislocation treated with anatomic coracoclavicular (CC) fixation using double clavicular tunnels. Methods: A retrospective review of patients with AC joint dislocation, treated with anatomic CC fixation using double clavicular tunnels, was conducted. Patients with pre-operative, immediate post-operative, and final follow-up Zanca-view X-rays were included. On each X-ray, the obtained measures included: distance from lateral border of clavicle to trapezoid and conoid tunnels, distance between tunnels, clavicle length, and CC distance of affected and un-affected sides. Loss of reduction was calculated as CC distance difference between immediate and final post-operative X-rays. Association between reduction loss and tunnel positioning was analyzed. Results: Conoid, trapezoid and tunnel ratios were 24% ± 4, 15% ± 3, and 9% ± 2, respectively. Significant reduction loss was seen in 21(45.7%) patients. Significantly higher probabilities of reduction loss were associated with trapezoid tunnels placed medial to 24 mm (30.8% vs 65.0%, OR 4.2 (IC95%: 1.2–14.4), p: 0.024) or 15% of the clavicle length (32.1% vs 66.7%, OR 4.2 (IC 95%: 1.2–14.9), p: 0.025). Conclusions: Trapezoid tunnels placed medial to 24 mm or 15% medial to clavicle length could lead to higher probabilities of significant reduction loss. These findings support the importance of clavicular tunnels’ proper placement for decreasing significant reduction loss.
- 25 April 2023
- Published by SAGE Publications in Shoulder & Elbow
- Vol. 16 (3) , 265-273
Medial placement of trapezoid tunnel leads to higher reduction loss in acute acromioclavicular joint dislocation treated with anatomic coracoclavicular fixation
Aim: To analyze the association between clavicular tunnel positioning and postoperative reduction loss in patients with acute acromioclavicular (AC) joint dislocation treated with anatomic coracoclavicular (CC) fixation using double clavicular tunnels. Methods: A retrospective review of patients with AC joint dislocation, treated with anatomic CC fixation using double clavicular tunnels, was conducted. Patients with pre-operative, immediate post-operative, and final follow-up Zanca-view X-rays were included. On each X-ray, the obtained measures included: distance from lateral border of clavicle to trapezoid and conoid tunnels, distance between tunnels, clavicle length, and CC distance of affected and un-affected sides. Loss of reduction was calculated as CC distance difference between immediate and final post-operative X-rays. Association between reduction loss and tunnel positioning was analyzed. Results: Conoid, trapezoid and tunnel ratios were 24% ± 4, 15% ± 3, and 9% ± 2, respectively. Significant reduction loss was seen in 21(45.7%) patients. Significantly higher probabilities of reduction loss were associated with trapezoid tunnels placed medial to 24 mm (30.8% vs 65.0%, OR 4.2 (IC95%: 1.2–14.4), p: 0.024) or 15% of the clavicle length (32.1% vs 66.7%, OR 4.2 (IC 95%: 1.2–14.9), p: 0.025). Conclusions: Trapezoid tunnels placed medial to 24 mm or 15% medial to clavicle length could lead to higher probabilities of significant reduction loss. These findings support the importance of clavicular tunnels’ proper placement for decreasing significant reduction loss.
- Open Access
- 1 March 2020
- Published by Georg Thieme Verlag KG in Revista Chilena de Ortopedia y Traumatología
- Vol. 61 (01) , 018-022
Modelo Predictivo de la No Unión de Tibia
Resumen: Objetivos Estimar un modelo predictivo para la no-unión en pacientes que presentan fractura de tibia. Materiales y Métodos Estudio de cohorte retrospectivo, en pacientes con fractura de tibia operadas entre 2012 y 2018, con un mínimo de 12 meses de seguimiento, excluyendo amputaciones traumáticas. Realizamos un modelo de regresión logística con 13 variables descritas en la literatura. Se descartaron las variables estadísticamente no significativas y las que no causaban efecto de confusión. Se evaluó la bondad de ajuste mediante el test de Hosmer-Lemeshow y la discriminación del modelo con la curva ROC. Resultados Se incluyeron 411 fracturas de tibia, las variables estadísticamente significativas fueron: exposición ósea OR = 2,57(IC:1,15–5,75, p = 0,022), diabetes OR = 3,29(IC:1,37–7,91, p = 0,008) y uso de tutor externo OR = 1,77(IC:0,81–3,85), el que tuvo efecto de confusión. La bondad de ajuste demostró que los datos se ajustan adecuadamente al modelo (p = 0,35). La curva ROC demuestra un 70,91% de poder discriminatorio. Al evaluar aisladamente las fracturas expuestas, no hubo asociación estadísticamente significativa con ninguna variable. Discusión Al evaluar el modelo, obtuvimos una asociación estadísticamente significativa entre: no unión, exposición ósea, diabetes y uso de tutor externo, información concordante con la literatura. Al estudiar el subgrupo de fracturas expuestas, las demás variables son estadísticamente no significativas. Eso refleja que la exposición ósea es la variable que confiere mayor riesgo. El seguimiento adecuado de esos pacientes es fundamental dado este alto riesgo de evolucionar con no-unión. Conclusión En nuestra serie, la exposición ósea es el factor de riesgo más importante para presentar no unión de tibia.
- 1 March 2020
- Published by Georg Thieme Verlag KG in Revista Chilena de Ortopedia y Traumatología
- Vol. 61 (01) , 018-022
Open AccessModelo Predictivo de la No Unión de Tibia
Resumen: Objetivos Estimar un modelo predictivo para la no-unión en pacientes que presentan fractura de tibia. Materiales y Métodos Estudio de cohorte retrospectivo, en pacientes con fractura de tibia operadas entre 2012 y 2018, con un mínimo de 12 meses de seguimiento, excluyendo amputaciones traumáticas. Realizamos un modelo de regresión logística con 13 variables descritas en la literatura. Se descartaron las variables estadísticamente no significativas y las que no causaban efecto de confusión. Se evaluó la bondad de ajuste mediante el test de Hosmer-Lemeshow y la discriminación del modelo con la curva ROC. Resultados Se incluyeron 411 fracturas de tibia, las variables estadísticamente significativas fueron: exposición ósea OR = 2,57(IC:1,15–5,75, p = 0,022), diabetes OR = 3,29(IC:1,37–7,91, p = 0,008) y uso de tutor externo OR = 1,77(IC:0,81–3,85), el que tuvo efecto de confusión. La bondad de ajuste demostró que los datos se ajustan adecuadamente al modelo (p = 0,35). La curva ROC demuestra un 70,91% de poder discriminatorio. Al evaluar aisladamente las fracturas expuestas, no hubo asociación estadísticamente significativa con ninguna variable. Discusión Al evaluar el modelo, obtuvimos una asociación estadísticamente significativa entre: no unión, exposición ósea, diabetes y uso de tutor externo, información concordante con la literatura. Al estudiar el subgrupo de fracturas expuestas, las demás variables son estadísticamente no significativas. Eso refleja que la exposición ósea es la variable que confiere mayor riesgo. El seguimiento adecuado de esos pacientes es fundamental dado este alto riesgo de evolucionar con no-unión. Conclusión En nuestra serie, la exposición ósea es el factor de riesgo más importante para presentar no unión de tibia.