JSJohn Swan

John Swan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


John Swan has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Current role of intraoperative sensing technology in total knee arthroplasty

    by Cécile Batailler, John Swan, Elliot Sappey Marinier, Elvire Servien, Sébastien Lustig

    Purpose Sensors have been introduced within the last 10 years to quantify soft tissue balancing during total knee arthroplasty (TKA) and to give the surgeon objective data. These devices are fairly new and their impact on patient outcome remains uncertain. The aim of this systematic review was to summarize all the relevant surgical and clinical results of sensors for TKA. Methods A PRISMA systematic review was conducted using five databases (PubMed, EMBASE, MEDLINE, GOOGLE SCHOLAR, and the COCHRANE LIBRARY) to identify all available literature that described the surgical and clinical results of sensors for TKA between 2000 and 2021. The main investigated outcome criteria were intraoperative data, postoperative functional and clinical outcome, knee range of motion, complications and revision rates. Results Twenty-seven articles were finally included. The maximum reported follow-up was 26 months. A balanced knee with sensor corresponded to a mediolateral difference inferior to 15 lb and a stable posterior drawer test. The standard assessment of knee balance was a poor predictor of the true soft tissue balance when compared to sensor data. At least 60% of TKA needed an additional rebalancing procedure with the sensor, after conventional gap balancing. Achieving a quantitatively balanced knee resulted in a significantly higher patient satisfaction score. But the prospective comparative studies found no demonstrable improvement in clinical outcome, range of motion or complication rate at one year postoperatively for patients undergoing TKA using sensor-guided balancing compared with routine techniques. Conclusion Even though the use of the intraoperative sensing technology was not related to an improvement in clinical outcome, the current studies showed that using sensors facilitates the reproduction of natural joint stability, and improves the rate of achieving a balanced knee. Sensor use in complex cases could be particularly valuable, but their use in standard practice remains to be defined.


  • Top Cited Papers

    Mechanical alignment for primary TKA may change both knee phenotype and joint line obliquity without influencing clinical outcomes: a study comparing restored and unrestored joint line obliquity

    by Elliot Sappey‐Marinier, Cécile Batailler, John Swan, Axel Schmidt, Laurence Cheze, Samuel J. MacDessi, Elvire Servien, Sébastien Lustig

    Purpose: In total knee arthroplasty (TKA), knee phenotypes including joint line obliquity are of interest regarding surgical realignment strategies. The hypothesis of this study is that better clinical results, including decreased postoperative knee pain, will be observed for patients with a restored knee phenotype.Methods: A retrospective analysis was performed on prospective data, including 1078 primary osteoarthritic knees in 936 patients. The male:female ratio was 780:298, mean age at surgery was 71.3 years ± 8.0. International Knee Society Scores and standardized long‐leg radiographs (LLR) were collected preoperatively and at 2 years follow‐up after TKA. Patients were categorized using the Coronal Plane Alignment of the Knee (CPAK) classification including the lateral distal femoral angle (LDFA) and medial proximal tibial angle (MPTA) measured on LLR by a single observer, allowing knee phenotypes to be categorized considering the arithmetic hip–knee–ankle (aHKA) angle (MPTA‐LDFA) as measure of constitutional alignment, and joint line obliquity (JLO) (MPTA + LDFA). Clinical results were compared between patients with surgically restored preoperative constitutional knee phenotype to patients without restored constitutional knee phenotypes. Descriptive data analysis such as means, standard deviations and ranges were performed. T tests for independent samples were performed to compare group differences. Comparisons of categorical data were performed using the χ2 test. Significance was set at p < 0.05.Results: A third of patients (33.4%) had constitutional knee varus with apex distal JLO. 63.5% of patients had preoperative apex distal JLO. Postoperatively, 57.8% of patients had a neutral HKA (− 2° to 2°) and a neutral JLO (− 3° and 3°), with only 18% of patients with restored constitutional knee phenotype. Of these patients, statistically less postoperative pain was observed in patients where apex distal JLO was restored compared to non‐restored apex distal JLO (pain score 46.7 vs. 44.6; p = 0.02) without clinical relevance. Other categories of restored JLO or arithmetic HKA angle were not associated with improved outcomes.Conclusion: This study showed that performing mechanical alignment for primary TKA resulted in most cases in a change of the preoperative knee phenotype. These results emphasize the relevance of considering joint line obliquity to better understand preoperative knee deformity and better restore knee phenotypes with a more personalized realignment strategy to potentially improve TKA postoperative results.Level of evidence: III.


  • Lateral approach total knee arthroplasty achieves equivalent patellar tracking in severe valgus deformity compared to mild valgus deformity

    by Julien Erard, Cécile Batailler, John Swan, Elliot Sappey‐Marinier, Elvire Servien, Sébastien Lustig

    Purpose: Patellar tracking problems represent 2–10% of complications of total knee arthroplasties (TKA) in valgus knees. However, there are no studies assessing patellar tracking according to the severity of the valgus deformity. The hypothesis was that lateral approach TKA in severe valgus deformity provides equivalent patellar tracking to that in knees with mild valgus deformity.Methods: Between 1988 and 2016, 77 TKAs were performed via a lateral approach on a severe valgus deformity (HKA > 195°). Forty‐three TKAs performed without tibial tubercle osteotomy and with complete radiological data were included in this study. These were compared with 86 matched TKAs performed via a lateral approach with a mild valgus deformity (HKA between 181° and 190°). Patellar tilt and patellar position were assessed by axial view radiographs at the last follow‐up. Complications and clinical outcomes were also evaluated.Results: The follow‐up was mean 52 ± 21 months in the severe valgus group. No significant differences were found between the severe valgus deformity group and the mild valgus deformity groups in patellar tilt (1.6° ± 6.6° versus 1.9° ± 3.2°, respectively) or patellar subluxation. There were complications in 12% (n = 5) and 11% (n = 9) of the severe valgus group and the mild valgus group respectively, without significant difference. There was no significant difference in extensor mechanism complication rate (2.3% versus 4.7%, respectively).Conclusion: Lateral parapatellar approach, without tibial tubercle osteotomy, for TKA in severe valgus deformity results in good patellar tracking. With this approach, the extensor mechanism complication rate in severe valgus deformity was not higher than for mild valgus deformity.Level of evidence: III.


  • Open Access

    New Technologies in Knee Arthroplasty: Current Concepts

    by Cécile Batailler, John Swan, Elliot Sappey Marinier, Elvire Servien, Sébastien Lustig

    Total knee arthroplasty (TKA) is an effective treatment for severe osteoarthritis. Despite good survival rates, up to 20% of TKA patients remain dissatisfied. Recently, promising new technologies have been developed in knee arthroplasty, and could improve the functional outcomes. The aim of this paper was to present some new technologies in TKA, their current concepts, their advantages, and limitations. The patient-specific instrumentations can allow an improvement of implant positioning and limb alignment, but no difference is found for functional outcomes. The customized implants are conceived to reproduce the native knee anatomy and to reproduce its biomechanics. The sensors have to aim to give objective data on ligaments balancing during TKA. Few studies are published on the results at mid-term of these two devices currently. The accelerometers are smart tools developed to improve the TKA alignment. Their benefits remain yet controversial. The robotic-assisted systems allow an accurate and reproducible bone preparation due to a robotic interface, with a 3D surgical planning, based on preoperative 3D imaging or not. This promising system, nevertheless, has some limits. The new technologies in TKA are very attractive and have constantly evolved. Nevertheless, some limitations persist and could be improved by artificial intelligence and predictive modeling.


  • No significant clinical and radiological differences between fixed versus mobile bearing total knee replacement using the same semi‐constrained implant type: a randomized controlled trial with mean 10 years follow‐up

    by E. Sappey‐Marinier, J. Swan, D. Maucort‐Boulch, C. Batailler, M. Malatray, P. Neyret, S. Lustig, E. Servien

    Purpose: The aim of this study was to compare the long‐term clinical and radiological results between fixed (FB) and mobile bearing (MB) implants with identical design from the same manufacturer.Methods: From March 2007 to May 2009, we recruited 160 patients in a prospective, single centered, randomized controlled trial. The authors compared 81 FB total knee arthroplasty (TKA) versus 79 MB with medial compartment osteoarthritis. The same posterior stabilized HLS Noetos knee prosthesis (CORIN) was used in all patients. The two groups only differed by the tibial insert (fixed or mobile). The authors compared the postoperative Knee Society Score (KSS), the passive clinical and active radiological knee flexion, the implant survivorship, the complications, and the presence of radiolucent lines.Results: At mean 10.5 years’ follow‐up (range 8–12.1 years) no significant differences were found in clinical scores (KSS (p = 0.54), pain score (p = 0.77), stair climbing (p = 0.44), passive maximum flexion (p = 0.5)) or for radiological analyses (maximum active radiological flexion (p = 0.06), presence of progressive radiolucent lines (5 (MB group) versus 6 (FB group);p = 0.75)) between groups. No significant difference was found in overall implant survivorship (82% (MB group) versus 78% (FB group) p = 0.58) or complication rate (p = 0.32) at the last follow‐up.Conclusion: No significant clinical and radiological differences were found between fixed and mobile bearing TKA using the same semi‐constrained implant type with comparable overall survivorship. The choice between a fixed or mobile bearing implant should be based on surgeon preference and experience with the selected implant.Level of evidence: Prospective randomized controlled trial, Level II.


  • Top Cited Papers

    MAKO CT‐based robotic arm‐assisted system is a reliable procedure for total knee arthroplasty: a systematic review

    by Cécile Batailler, Andrea Fernandez, John Swan, Elvire Servien, Fares S. Haddad, Fabio Catani, Sébastien Lustig

    Purpose: The aim of this study was to investigate the clinical and radiological results of the MAKO CT‐based robotic‐assisted system for total knee arthroplasty (TKA).Methods: A PRISMA systematic review was conducted using four databases (MEDLINE, EMBASE, Pubmed, GOOGLE SCHOLAR) to identify all clinical and radiological studies reporting information regarding the use and results of the CT‐based robotic‐assisted system to perform TKA between 2016 and 2020. The main investigated outcome criteria were postoperative pain, analgesia requirements, clinical scores, knee range of motion, implant positioning and the revision rate. The ROBINS‐I tool (Risk Of Bias In Non‐randomized Studies of Interventions) was used to evaluate the quality of included studies and the risk of bias.Results: A total of 36 studies were identified, of which 26 met inclusion criteria. Of these 26 studies, 14 were comparative. The follow‐up varied from 30 days to 17 months. This CT‐based, saw cutting Robotic TKA is associated with a significantly lower postoperative pain score (2.6 versus 4.5) and with significantly reduced time to hospital discharge (77 h versus 105), compared with conventional TKA. The two comparative studies assessing functional outcomes at 1 year reported significantly better functional scores with CT‐based robotic TKA compared with conventional TKA (WOMAC score: 6 ± 6 versus 9 ± 8 (p < 0.05); KSS function score: 80 versus 73 (p = 0.005)). Only three comparative studies assessed implant positioning, and these reported better implant positioning with CT‐based robotic‐assisted TKA.Conclusion: The CT‐based robotic‐assisted system for TKA reduced postoperative pain and improved implant positioning with equal or slightly superior improvement of the functional outcomes at one year, compared to conventional TKA.Level of evidence: Systematic review level IV.


  • Primary osteoarthritic knees have more varus coronal alignment of the femur compared to young non‐arthritic knees in a large cohort study

    by Elliot Sappey‐Marinier, Cécile Batailler, John Swan, Matthieu Malatray, Laurence Cheze, Elvire Servien, Sébastien Lustig

    Purpose: Many surgeons are performing total knee arthroplasty (TKA) with an aim to reproducing native anatomical coronal alignment. Yet, it remains unclear if primary osteoarthritic and non‐osteoarthritic populations have similar knee coronal alignment. This study aims to describe and compare the distribution of femoral and tibial coronal alignment in a large primary osteoarthritic cohort and a young non‐osteoarthritic cohort.Methods: This is a retrospective analysis of a monocentric prospectively gathered data, from 1990 to 2019, of 2859 consecutive primary osteoarthritic knees in 2279 patients. Patients underwent standardized long‐leg radiographs. Femoral mechanical angle (FMA) and tibial mechanical angle (TMA) were digitally measured using software. Femoral, tibial and knee phenotypes were analyzed, and descriptive data were reported. Data were compared to a young non‐osteoarthritic population previously described.Results: In osteoarthritic knees, the mean FMA was 91° ± 2.9° (range 86°–100°) and the mean TMA was 87° ± 3.1° (range 80°–94°). No significant difference was observed for FMA and TMA between genders. The most common femoral and tibial phenotypes were varus (38.7%) and neutral (37.1%). The most frequent knee phenotype was a varus femoral phenotype with a neutral tibial phenotype (15.5%), which is different to the non‐osteoarthritic population.Conclusion: This study showed the wide distribution of knee phenotypes in a large osteoarthritic cohort. There was more varus distribution of the femoral coronal alignment compared to a non‐osteoarthritic population, suggesting consideration and potential adaptation of the realignment strategy of the femoral component during TKA.Level of evidence: III.


  • Patellar component size effects patellar tilt in total knee arthroplasty with patellar resurfacing

    by Léopold Joseph, Cécile Batailler, Julien Roger, John Swan, Elvire Servien, Sébastien Lustig

    Purpose: Patellar component positioning and patellofemoral kinematics are of great importance in total knee arthroplasty (TKA). The factors influencing patellar tilt are femoral rotation and lateral patellar release. However, the effect of patellar component size remains unknown. The aim of this study was to evaluate the intra‐operative risk factors for patellar tilt, particularly the effect of the patellar component size. The hypothesis was that increasing the patellar component size would reduce the risk of patellar tilt.Methods: 878 primary TKAs with patellar resurfacing were included between January 2015 and October 2018. Analysis was performed at 1‐year postoperatively on patients categorized into two groups: patellar tilt (PT) and no patellar tilt (NPT). A multivariate analysis was performed for the effect of patellar component size, femoral rotation, femoral overbuilding, patellar thickness and lateral release on patellar tilt risk. Secondary analysis was performed for any difference in clinical outcomes and revision rates between groups.Results: Multivariate analysis showed that increasing the patellar component size decreased the risk of patellar tilt by 37% (p < 0.001). Placing the femoral component at 3° of external rotation decreased the risk of patellar tilt by 67% (p < 0.001). Secondary analysis showed better clinical outcomes in the NPT group, especially regarding global satisfaction, and KSS objective and subjective scores. The revision for any cause was less in the NPT group (p = 0.019). The cause for TKA revision was related to the patellar in 11% of cases in the NPT group and 65% in the PT group (p < 0.001).Conclusion: Increased patellar component size and positioning the femoral component in external rotation decreases the risk of patellar tilt, improves clinical outcomes and decreases the rate of surgical revision.Level of evidence: III.


  • Lateral acromioplasty cannot sufficiently reduce the critical shoulder angle if preoperatively measured over 40°

    by Manuel Ignacio Olmos, Achilleas Boutsiadis, John Swan, Paul Brossard, Renaud Barthelemy, Philippe Delsol, Johannes Barth

    Purpose: To investigate whether arthroscopic lateral acromion resection can sufficiently reduce the critical shoulder angle (CSA) without damaging deltoid muscle insertion.Methods: Ninety patients who underwent arthroscopic rotator cuff (RC) repair were retrospectively analysed. According to the preoperative CSA, patients were categorized as Group I (CSA < 35°) and Group II (CSA ≥ 35°). Additional arthroscopic lateral acromion resection was performed in Group II. The CSA was measured 1 week postoperatively, while RC integrity and the deltoid attachment were assessed at 3, 6 and 12 months via ultrasound. Deltoid function was evaluated using the Akimbo test, in which patients place their hands on the iliac crest with abduction in the coronal plane and internal rotation of the shoulder joint while simultaneously flexing the elbow joint and pronating the forearm.Results: Large and massive RC tears were more prevalent in Group II (p = 0.017). In both groups, the CSA reduction was statistically significant (Group I = 1°: range 0°–3°, Group II = 3.7°: range 1°–8°; p < 0.001). When the preoperative CSA was > 40°, the respective postoperative CSA remained > 35° in 83.3% of cases (p < 0.001). Final shoulder strength was correlated with the amount of CSA reduction (rho = 0.41, p = 0.002). The postoperative CSA was higher, but not significantly different (n.s.), in patients with re‐torn (36°, range 32°–40°) than with healed RC (33°, range 26°–38°). No clinical detachment or hypotrophy of the deltoid was observed with the Akimbo test and ultrasound evaluation.Conclusions: Arthroscopic lateral acromion resection is a safe procedure without affecting deltoid muscle origin or function, and it is effective in significantly reducing the CSA. However, the CSA cannot always be reduced to < 35°, especially in patients with preoperative CSA values > 40°.Level of evidence: III.


  • Open Access

    Arthroscopic Trillat Procedure: A Guided Technique

    by John Swan, Pascal Boileau, Johannes Barth

    The Trillat procedure is a surgical treatment for recurrent anterior shoulder instability in the setting of significant or irreparable rotator cuff tears in elderly patients. The procedure comprises an inferior closing wedge partial osteotomy of the coracoid process with fixation to the glenoid neck. This results in a lowered and medialized coracoid process that acts as a bone block and the conjoint tendon is brought closer to the glenohumeral joint, thus closing the subcoracoid space, which blocks humeral dislocation. We describe an arthroscopic step‐by‐step guided Trillat technique that is simple, efficient, and reproducible, while minimizing risk in the extra‐articular subcoracoid space. Our technique does not require the release of the pectoralis minor tendon from the coracoid process, which reduces the risk of damaging the brachial plexus. We use a tight‐rope fixation construct that allows progressive transfer of the coracoid process, limiting fracture risk and the risk of overtightening of the subscapularis muscle. Because there is a trend for more complex procedures being performed arthroscopically, it is important to develop and simplify operative techniques, aiding surgeons in achieving reproducible and reliable patient outcomes. Technique Video: video See video under supplementary data.