Sina Nejati
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sina Nejati has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Rahim Rahimi
School of Electrical and Computer Engineering, Purdue University, West Lafayette, USA
9 shared publications Venkat Kasi
School of Materials Engineering, Purdue University, West Lafayette, IN, 47907, USA
4 shared publicationsAkshay Krishnakumar
Birck Nanotechnology Center, Purdue University, West Lafayette, IN 47907, USA
3 shared publicationsSarath Gopalakrishnan
Birck Nanotechnology Centre, Purdue University, West Lafayette, IN, 47907, USA
3 shared publicationsSeyed Ahmad Mirbagheri
3 shared publications- Sotoudeh Sedaghat
Birck Nanotechnology Center, Purdue University, West Lafayette, IN, 47907, USA
3 shared publications
Latest Publications
- Open Access
- 5 July 2024
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 12 (31) , 11861-11876
Cold atmospheric plasma deposition of antibacterial polypyrrole–silver nanocomposites on wearable electronics for prolonged performance
Wearable electronics have become integral for monitoring physiological parameters in diverse applications, particularly in medical and military fields. e-Textiles, featuring integrated conductive threads or fabrics, offer seamless integration and comfort for prolonged contact with the body. Despite their potential, the biofouling of textile-based electrode systems by skin microbes remains a significant challenge, limiting their operational lifespan. Recent studies have highlighted the efficacy of conductive nanocomposites with antibacterial agents, such as silver nanoparticles (AgNPs), in addressing biofouling concerns. However, implementing such systems on 3D fibrous structures and textile surfaces often proves complex and inefficient. To overcome these challenges, we explored cold atmospheric plasma (CAP)-based in situ polymerization for the direct deposition of functional conductive polypyrrole–silver (PPy–Ag) nanocomposites onto conductive textile surfaces. For this process, a customized CAP deposition system was engineered, enabling precise material deposition through robotic control of the plasma jet. This process achieved direct, conformal attachment onto textile fibrous structures, ensuring uniform distribution of conductive polypyrrole and silver in the form of AgNPs throughout the polymer polypyrrole matrix without compromising fabric flexibility and breathability, which was validated through different surface electron microscopy and chemical analysis (e.g., EDX, FTIR, Raman, and XRD). Systematic studies with various precursor mixtures identified an optimized PPy–Ag composition that demonstrated stable antibacterial properties and biocompatibility against common skin microbes and epithelial cells. Systematic studies with various precursor mixtures identified an optimized PPy–Ag composition, with the precursor mixture containing 96 wt% pyrrole and 4 wt% AgNO3 weight ratios as the optimal surface coating process, demonstrating stable antibacterial properties and biocompatibility against common skin microbes and epithelial cells respectively. As a proof of concept, the nanocomposite coating was applied to conductive carbon fabric surfaces as dry electrodes in a wearable garment for continues electrocardiography (ECG) monitoring over 10 days. Results revealed a significantly longer performance of the dry electrodes as comparable to standard gel-based Ag/AgCl electrodes (1 day) while providing less noise in ECG signal measurements from the subject, showcasing the potential of this technology for practical wearable applications. Envisioned as a groundbreaking solution, this technology opens new avenues for the scalable and effective integration of functional conductive circuits and sensors into everyday garments, ensuring prolonged and efficient performance in wearable electronics.
- 5 July 2024
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 12 (31) , 11861-11876
Open AccessCold atmospheric plasma deposition of antibacterial polypyrrole–silver nanocomposites on wearable electronics for prolonged performance
Wearable electronics have become integral for monitoring physiological parameters in diverse applications, particularly in medical and military fields. e-Textiles, featuring integrated conductive threads or fabrics, offer seamless integration and comfort for prolonged contact with the body. Despite their potential, the biofouling of textile-based electrode systems by skin microbes remains a significant challenge, limiting their operational lifespan. Recent studies have highlighted the efficacy of conductive nanocomposites with antibacterial agents, such as silver nanoparticles (AgNPs), in addressing biofouling concerns. However, implementing such systems on 3D fibrous structures and textile surfaces often proves complex and inefficient. To overcome these challenges, we explored cold atmospheric plasma (CAP)-based in situ polymerization for the direct deposition of functional conductive polypyrrole–silver (PPy–Ag) nanocomposites onto conductive textile surfaces. For this process, a customized CAP deposition system was engineered, enabling precise material deposition through robotic control of the plasma jet. This process achieved direct, conformal attachment onto textile fibrous structures, ensuring uniform distribution of conductive polypyrrole and silver in the form of AgNPs throughout the polymer polypyrrole matrix without compromising fabric flexibility and breathability, which was validated through different surface electron microscopy and chemical analysis (e.g., EDX, FTIR, Raman, and XRD). Systematic studies with various precursor mixtures identified an optimized PPy–Ag composition that demonstrated stable antibacterial properties and biocompatibility against common skin microbes and epithelial cells. Systematic studies with various precursor mixtures identified an optimized PPy–Ag composition, with the precursor mixture containing 96 wt% pyrrole and 4 wt% AgNO3 weight ratios as the optimal surface coating process, demonstrating stable antibacterial properties and biocompatibility against common skin microbes and epithelial cells respectively. As a proof of concept, the nanocomposite coating was applied to conductive carbon fabric surfaces as dry electrodes in a wearable garment for continues electrocardiography (ECG) monitoring over 10 days. Results revealed a significantly longer performance of the dry electrodes as comparable to standard gel-based Ag/AgCl electrodes (1 day) while providing less noise in ECG signal measurements from the subject, showcasing the potential of this technology for practical wearable applications. Envisioned as a groundbreaking solution, this technology opens new avenues for the scalable and effective integration of functional conductive circuits and sensors into everyday garments, ensuring prolonged and efficient performance in wearable electronics.
- Open Access
- 22 April 2024
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 12 (18) , 4489-4501
Laser-assisted surface alloying of titanium with silver to enhance antibacterial and bone-cell mineralization properties of orthopedic implants
Orthopedic device-related infection (ODRI) poses a significant threat to patients with titanium-based implants. The challenge lies in developing antibacterial surfaces that preserve the bulk mechanical properties of titanium implants while exhibiting characteristics similar to bone tissue. In response, we present a two-step approach: silver nanoparticle (AgNP) coating followed by selective laser-assisted surface alloying on commonly used titanium alumina vanadium (TiAl6V4) implant surfaces. This process imparts antibacterial properties without compromising the bulk mechanical characteristics of the titanium alloy. Systematic optimization of laser beam power (8–40 W) resulted in an optimized surface (32 W) with uniform TiAg alloy formation. This surface displayed a distinctive hierarchical mesoporous textured surface, featuring cauliflower-like nanostructures measuring between 5–10 nm uniformly covering spatial line periods of 25 μm while demonstrating homogenous elemental distribution of silver throughout the laser processed surface. The optimized laser processed surface exhibited prolonged superhydrophilicity (40 days) and antibacterial efficacy (12 days) against Staphylococcus aureus and Escherichia coli. Additionally, there was a significant twofold increase in bone mineralization compared to the pristine Ti6Al4V surface (p < 0.05). Rockwell hardness tests confirmed minimal (<1%) change in bulk mechanical properties compared to the pristine surface. This innovative laser-assisted approach, with its precisely tailored surface morphology, holds promise for providing enduring antibacterial and osteointegration properties, rendering it an optimal choice for modifying load-bearing implant devices without altering material bulk characteristics.
- 22 April 2024
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 12 (18) , 4489-4501
Open AccessLaser-assisted surface alloying of titanium with silver to enhance antibacterial and bone-cell mineralization properties of orthopedic implants
Orthopedic device-related infection (ODRI) poses a significant threat to patients with titanium-based implants. The challenge lies in developing antibacterial surfaces that preserve the bulk mechanical properties of titanium implants while exhibiting characteristics similar to bone tissue. In response, we present a two-step approach: silver nanoparticle (AgNP) coating followed by selective laser-assisted surface alloying on commonly used titanium alumina vanadium (TiAl6V4) implant surfaces. This process imparts antibacterial properties without compromising the bulk mechanical characteristics of the titanium alloy. Systematic optimization of laser beam power (8–40 W) resulted in an optimized surface (32 W) with uniform TiAg alloy formation. This surface displayed a distinctive hierarchical mesoporous textured surface, featuring cauliflower-like nanostructures measuring between 5–10 nm uniformly covering spatial line periods of 25 μm while demonstrating homogenous elemental distribution of silver throughout the laser processed surface. The optimized laser processed surface exhibited prolonged superhydrophilicity (40 days) and antibacterial efficacy (12 days) against Staphylococcus aureus and Escherichia coli. Additionally, there was a significant twofold increase in bone mineralization compared to the pristine Ti6Al4V surface (p < 0.05). Rockwell hardness tests confirmed minimal (<1%) change in bulk mechanical properties compared to the pristine surface. This innovative laser-assisted approach, with its precisely tailored surface morphology, holds promise for providing enduring antibacterial and osteointegration properties, rendering it an optimal choice for modifying load-bearing implant devices without altering material bulk characteristics.
- Open Access
- 31 January 2024
- Published by Wiley in Advanced Materials Technologies
- Vol. 9 (6)
Electronic‐Free Traceable Smart Capsule for Gastrointestinal Microbiome Sampling
Non‐invasive smart electronic‐free sampling capsules have revolutionized the exploration of microbiome‐disease interactions in inaccessible regions of the gastrointestinal (GI) tract. However, a significant impediment to the broader use of electronic‐free capsules is the challenge of reliably tracking and determining their in vivo location. Variability in patient motility introduces uncertainties in capsule position. Thus, there is a critical need for effective solutions that ensure traceability in microbiome studies employing such capsules. While tracking methods are explored in previous smart ingestible capsule designs, most have relied on RF, imaging, and radiation‐based techniques, limiting sampling volume, increasing costs, complicating design, and raising health concerns due to ionizing radiation exposure. To address these challenges, the design of an electronic‐free smart capsule is introduced that integrates a metal tracer for easy metal detection, serving as a reliable tracking mechanism. The capsule is housed in a 3D‐printed casing and includes a superabsorbent hydrogel serving as both a sampling medium and an actuator within the capsule. The capsule's targeted sampling of the GI tract is accomplished by covering the capsule's sampling port with a pH‐responsive coating. Optimal dimensions and material for the cylindrical shaped metal tracer on the capsule are determined through extensive optimizations, considering factors such as gastric flotation, corrosion resistance, read distance, and omnidirectional detectability. The results of these investigations reveal that a 12 mm stainless steel (SS 316L) cylinder offers the necessary detection and tracing capabilities with minimal toxicity and excellent corrosion resistance under relevant physiological conditions in the GI tract. Validation studies, both in vitro and in vivo, confirmed the capsule's trackability using a handheld metal detector. These findings are further validated by X‐ray imaging and CT scans, demonstrating the metal detector's ability to distinguish approximate GI tract regions and determine the time point of excretion. This innovative approach provides a reliable and cost‐effective solution for tracking electronic‐free smart capsules, enhancing their applicability in microbiome research for both human and animal studies.
- 31 January 2024
- Published by Wiley in Advanced Materials Technologies
- Vol. 9 (6)
Open AccessElectronic‐Free Traceable Smart Capsule for Gastrointestinal Microbiome Sampling
Non‐invasive smart electronic‐free sampling capsules have revolutionized the exploration of microbiome‐disease interactions in inaccessible regions of the gastrointestinal (GI) tract. However, a significant impediment to the broader use of electronic‐free capsules is the challenge of reliably tracking and determining their in vivo location. Variability in patient motility introduces uncertainties in capsule position. Thus, there is a critical need for effective solutions that ensure traceability in microbiome studies employing such capsules. While tracking methods are explored in previous smart ingestible capsule designs, most have relied on RF, imaging, and radiation‐based techniques, limiting sampling volume, increasing costs, complicating design, and raising health concerns due to ionizing radiation exposure. To address these challenges, the design of an electronic‐free smart capsule is introduced that integrates a metal tracer for easy metal detection, serving as a reliable tracking mechanism. The capsule is housed in a 3D‐printed casing and includes a superabsorbent hydrogel serving as both a sampling medium and an actuator within the capsule. The capsule's targeted sampling of the GI tract is accomplished by covering the capsule's sampling port with a pH‐responsive coating. Optimal dimensions and material for the cylindrical shaped metal tracer on the capsule are determined through extensive optimizations, considering factors such as gastric flotation, corrosion resistance, read distance, and omnidirectional detectability. The results of these investigations reveal that a 12 mm stainless steel (SS 316L) cylinder offers the necessary detection and tracing capabilities with minimal toxicity and excellent corrosion resistance under relevant physiological conditions in the GI tract. Validation studies, both in vitro and in vivo, confirmed the capsule's trackability using a handheld metal detector. These findings are further validated by X‐ray imaging and CT scans, demonstrating the metal detector's ability to distinguish approximate GI tract regions and determine the time point of excretion. This innovative approach provides a reliable and cost‐effective solution for tracking electronic‐free smart capsules, enhancing their applicability in microbiome research for both human and animal studies.
- 24 September 2022
- Published by Elsevier in Acta Biomaterialia
- Vol. 154, 83-96
Smart capsule for targeted proximal colon microbiome sampling
- 24 September 2022
- Published by Elsevier in Acta Biomaterialia
- Vol. 154, 83-96
Smart capsule for targeted proximal colon microbiome sampling
- 8 July 2022
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 10 (29) , 10562-10573
Improved performance of printed electrochemical sensors via cold atmospheric plasma surface modification
All-solid-state printed electrochemical sensors based on solid-contact ion-selective electrodes (SC-ISE) have shown great potential for use in many portable applications ranging from healthcare to environmental monitoring. Despite the low cost and scalable manufacturability of these sensors, they often underperform in long-term applications due to the formation of a water layer between the ion-selective membrane (ISM) and the printed electrode. Here, we report a simple approach to minimize the water layer formation and increase the stability of the SC-ISE by improving the interfacial bonding between the ISM and printed carbon electrodes through cold atmospheric plasma (CAP) treatment. A systematic study with different processing gas flow rates and power conditions was performed to identify the effect of CAP treatment on printed carbon electrode surface modification and to assess the role of functionalized surfaces in improving the sensor performance. To achieve maximal functionality, plasma settings were optimized with a minimum plasma power of 300 W and an oxygen flow rate of 120 mL min−1 which was further verified by surface characterization techniques including water contact angle measurements and Raman spectroscopy. X-Ray photoelectron spectra (XPS) of the plasma-treated (PT) electrode surfaces indicated the formation of functional groups including hydroxyl (–OH), carboxyl (–COOH), and carbonyl (–CO), all of which aided in maximizing surface energy and creation of strong covalent bonds between the printed carbon electrode and ISM. In addition, CAP treatment led to the decomposition/removal of impurities and the polymer binder from the surface of printed carbon which effectively increased the exposed uncontaminated graphene flakes on the surface of the electrodes. Finally, as a proof of concept, we demonstrated that the use of CAP treatment prior to the coating with a nitrate sensitive ISM resulted in improved chemical bonding between the layers and a significant reduction in the water layer formation, leading to enhanced long-term stability (7-fold improvement) as compared with that of the untreated electrode.
- 8 July 2022
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 10 (29) , 10562-10573
Improved performance of printed electrochemical sensors via cold atmospheric plasma surface modification
All-solid-state printed electrochemical sensors based on solid-contact ion-selective electrodes (SC-ISE) have shown great potential for use in many portable applications ranging from healthcare to environmental monitoring. Despite the low cost and scalable manufacturability of these sensors, they often underperform in long-term applications due to the formation of a water layer between the ion-selective membrane (ISM) and the printed electrode. Here, we report a simple approach to minimize the water layer formation and increase the stability of the SC-ISE by improving the interfacial bonding between the ISM and printed carbon electrodes through cold atmospheric plasma (CAP) treatment. A systematic study with different processing gas flow rates and power conditions was performed to identify the effect of CAP treatment on printed carbon electrode surface modification and to assess the role of functionalized surfaces in improving the sensor performance. To achieve maximal functionality, plasma settings were optimized with a minimum plasma power of 300 W and an oxygen flow rate of 120 mL min−1 which was further verified by surface characterization techniques including water contact angle measurements and Raman spectroscopy. X-Ray photoelectron spectra (XPS) of the plasma-treated (PT) electrode surfaces indicated the formation of functional groups including hydroxyl (–OH), carboxyl (–COOH), and carbonyl (–CO), all of which aided in maximizing surface energy and creation of strong covalent bonds between the printed carbon electrode and ISM. In addition, CAP treatment led to the decomposition/removal of impurities and the polymer binder from the surface of printed carbon which effectively increased the exposed uncontaminated graphene flakes on the surface of the electrodes. Finally, as a proof of concept, we demonstrated that the use of CAP treatment prior to the coating with a nitrate sensitive ISM resulted in improved chemical bonding between the layers and a significant reduction in the water layer formation, leading to enhanced long-term stability (7-fold improvement) as compared with that of the untreated electrode.
- 12 May 2022
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 10 (26) , 9813-9822
A wireless chipless printed sensor tag for real-time radiation sterilization monitoring
Gamma radiation is widely used for the sterilization of many single-use and temperature sensitive medical devices. However, many of such products require an appropriate dose of exposure to achieve proper sterility while having a minimal detrimental effect on the product's function. Therefore, the development of low-cost wireless dosimeters that could be placed in packaged medical products to accurately monitor the level of radiation exposure during the sterilization process is highly desirable. To address this need, here, we have developed an all printed wireless chipless sensor tag technology that allows remote assessment of radiation exposure levels of packaged products through a simple radio frequency (RF) backscattering principle. The sensor tag is composed of a twin printed sensing dipole antenna and reference strip antenna configuration where the sensing antenna is functionalized with an irreversible radiation sensitive conductive polymer blend of poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) and polyurethane (PEDOT:PSS/PU). The printed reference antenna is unmodified to be insensitive to radiation exposure and provides self-calibration point to each sensor tag. Upon exposure to gamma radiation, the electrical resistance of the PEDOT:PSS/PU polymer blend increases which results in a change in the input impedance and the level of RF power reflected from the sensing antenna. The overall level of radiation exposure of the sensor tag is determined by measuring the differential reflected power from the sensing antenna and reference antenna using a portable RF reader. To identify the optimum radiation sensitive functional material, a systematic sensing study is performed using different ratios of PEDOT:PSS and PU in the radiation exposure range of 0 to 40 kGy. Material characterization results show that the PEDOT:PSS/PU polymer blend at the percolation threshold of 90wt% PU content was capable of providing the highest sensitivity (375% change in impedance after 40 kGy exposure) with excellent stability and repeatability performance. Wireless measurements of the differential reflected power from the sensor tag to the RF reader reveal a high linear sensitivity of 0.1 dB kGy−1 within the working range of 0 to 40 kGy under optimized conditions. The demonstrated platform can provide new opportunities for more cost-effective and non-contact evaluation of radiation sterilization processes in a wide range of food and medical packaging applications.
- 12 May 2022
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 10 (26) , 9813-9822
A wireless chipless printed sensor tag for real-time radiation sterilization monitoring
Gamma radiation is widely used for the sterilization of many single-use and temperature sensitive medical devices. However, many of such products require an appropriate dose of exposure to achieve proper sterility while having a minimal detrimental effect on the product's function. Therefore, the development of low-cost wireless dosimeters that could be placed in packaged medical products to accurately monitor the level of radiation exposure during the sterilization process is highly desirable. To address this need, here, we have developed an all printed wireless chipless sensor tag technology that allows remote assessment of radiation exposure levels of packaged products through a simple radio frequency (RF) backscattering principle. The sensor tag is composed of a twin printed sensing dipole antenna and reference strip antenna configuration where the sensing antenna is functionalized with an irreversible radiation sensitive conductive polymer blend of poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) and polyurethane (PEDOT:PSS/PU). The printed reference antenna is unmodified to be insensitive to radiation exposure and provides self-calibration point to each sensor tag. Upon exposure to gamma radiation, the electrical resistance of the PEDOT:PSS/PU polymer blend increases which results in a change in the input impedance and the level of RF power reflected from the sensing antenna. The overall level of radiation exposure of the sensor tag is determined by measuring the differential reflected power from the sensing antenna and reference antenna using a portable RF reader. To identify the optimum radiation sensitive functional material, a systematic sensing study is performed using different ratios of PEDOT:PSS and PU in the radiation exposure range of 0 to 40 kGy. Material characterization results show that the PEDOT:PSS/PU polymer blend at the percolation threshold of 90wt% PU content was capable of providing the highest sensitivity (375% change in impedance after 40 kGy exposure) with excellent stability and repeatability performance. Wireless measurements of the differential reflected power from the sensor tag to the RF reader reveal a high linear sensitivity of 0.1 dB kGy−1 within the working range of 0 to 40 kGy under optimized conditions. The demonstrated platform can provide new opportunities for more cost-effective and non-contact evaluation of radiation sterilization processes in a wide range of food and medical packaging applications.
- 26 November 2021
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 22 (1) , 57-70
Small intestinal sampling capsule for inflammatory bowel disease type detection and management
Although serum and fecal biomarkers (e.g., lactoferrin, and calprotectin) have been used in management and distinction between inflammatory bowel disease (IBD) and irritable bowel syndrome (IBS), none are proven to be a differential diagnostic tool between Crohn's disease (CD) and ulcerative colitis (UC). The main challenge with laboratory-based biomarkers in the stool test is the inability to indicate the location of the disease/inflammation in the gastrointestinal (GI) tract due to the homogenous nature of the collected fecal sample. For the first time, we have designed and developed a battery-free smart capsule that will allow targeted sampling of inflammatory biomarkers inside the gut lumen of the small intestine. The capsule is designed to provide a simple and non-invasive complementary tool to fecal biomarker analysis to differentiate the type of IBD by pinpointing the site of inflammatory biomarkers secretion (e.g., small or large bowel) throughout the GI tract. The capsule takes advantage of the rapid change from an acidic environment in the stomach to higher pH levels in the small intestine to dissolve a pH-sensitive polymeric coating as a means to activate the sampling process of the capsule within the small intestine. A swelling polyacrylamide hydrogel is placed inside the capsule as a milieu to collect the sampled GI fluid while also providing the required mechanical actuation to close the capsule once the sampling is completed. The hydrogel component along with the collected GI fluid can be easily obtained from the capsule through the screw-cap design for further extraction and analysis. As a proof of concept, the capsule's performance in sampling and extraction of bovine serum albumin (BSA) and calprotectin – a key biomarker of inflammation – was assessed within the physiologically relevant ranges. The ratio of extracted biomarkers relative to that in the initial sampling environment remained constant (∼3%) and independent of the sampling matrix in both in vitro and ex vivo studies. It is believed that the demonstrated technology will provide immediate impact in more effective IBD type differential diagnostic and treatment strategies by providing a non-invasive assessment of inflammation biomarkers profile throughout the digestive tract.
- 26 November 2021
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 22 (1) , 57-70
Small intestinal sampling capsule for inflammatory bowel disease type detection and management
Although serum and fecal biomarkers (e.g., lactoferrin, and calprotectin) have been used in management and distinction between inflammatory bowel disease (IBD) and irritable bowel syndrome (IBS), none are proven to be a differential diagnostic tool between Crohn's disease (CD) and ulcerative colitis (UC). The main challenge with laboratory-based biomarkers in the stool test is the inability to indicate the location of the disease/inflammation in the gastrointestinal (GI) tract due to the homogenous nature of the collected fecal sample. For the first time, we have designed and developed a battery-free smart capsule that will allow targeted sampling of inflammatory biomarkers inside the gut lumen of the small intestine. The capsule is designed to provide a simple and non-invasive complementary tool to fecal biomarker analysis to differentiate the type of IBD by pinpointing the site of inflammatory biomarkers secretion (e.g., small or large bowel) throughout the GI tract. The capsule takes advantage of the rapid change from an acidic environment in the stomach to higher pH levels in the small intestine to dissolve a pH-sensitive polymeric coating as a means to activate the sampling process of the capsule within the small intestine. A swelling polyacrylamide hydrogel is placed inside the capsule as a milieu to collect the sampled GI fluid while also providing the required mechanical actuation to close the capsule once the sampling is completed. The hydrogel component along with the collected GI fluid can be easily obtained from the capsule through the screw-cap design for further extraction and analysis. As a proof of concept, the capsule's performance in sampling and extraction of bovine serum albumin (BSA) and calprotectin – a key biomarker of inflammation – was assessed within the physiologically relevant ranges. The ratio of extracted biomarkers relative to that in the initial sampling environment remained constant (∼3%) and independent of the sampling matrix in both in vitro and ex vivo studies. It is believed that the demonstrated technology will provide immediate impact in more effective IBD type differential diagnostic and treatment strategies by providing a non-invasive assessment of inflammation biomarkers profile throughout the digestive tract.
- 1 October 2021
- Published by Elsevier in Nano Energy
- Vol. 88
Nanofluids improve energy efficiency of membrane distillation
- 1 October 2021
- Published by Elsevier in Nano Energy
- Vol. 88
Nanofluids improve energy efficiency of membrane distillation
- 1 October 2020
- Published by Elsevier in Journal of Environmental Chemical Engineering
- Vol. 8 (5)
Laser Functionalization of Carbon Membranes for Effective Immobilization of Antimicrobial Silver Nanoparticles
- 1 October 2020
- Published by Elsevier in Journal of Environmental Chemical Engineering
- Vol. 8 (5)
Laser Functionalization of Carbon Membranes for Effective Immobilization of Antimicrobial Silver Nanoparticles
- Open Access
- 24 April 2020
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 10 (28) , 16313-16322
Smart capsule for non-invasive sampling and studying of the gastrointestinal microbiome
Gut microbiota plays an important role in host physiology such as obesity, diabetes, and various neurological diseases. Thus, microbiome sampling is a fundamental approach towards better understanding of possible diseases. However, conventional sampling methods, such as endoscopies or colonoscopies, are invasive and cannot reach the entire small intestine. To address this need, a battery-less 3D-printed sampling capsule, which can collect microbiome samples throughout the entirety of the GI tract was designed. The capsule (9 mm × 15 mm) consists of a 3D printed acrylic housing, a fast-absorbing hydrogel, and a flexible PDMS membrane. Fluids containing samples of the microbial flora within the GI tract enter the device through a sampling aperture on the cap of the device. Once the microbiome enters the housing, the hydrogel absorbs the fluid and swells, effectively protecting the samples within its polymeric matrix, while also pushing on the flexible PDMS membrane to block the sampling aperture from further fluid exchange. The retrieved capsule can be readily disassembled due to the screw-cap design of the capsule and the hydrogel can be removed for further bacterial culture and analysis. As a proof of concept, the capsule's bacterial sampling efficiency and the ability to host microbial samples within the hydrogel in a sealed capsule were validated using a liquid culture containing Escherichia coli. The demonstrated technology provides a promising inexpensive tool for direct sampling and assessment of microbes throughout the GI tract and can enable new insights into the role of diet in mediating host–microbe interactions and metabolism.
- 24 April 2020
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 10 (28) , 16313-16322
Open AccessSmart capsule for non-invasive sampling and studying of the gastrointestinal microbiome
Gut microbiota plays an important role in host physiology such as obesity, diabetes, and various neurological diseases. Thus, microbiome sampling is a fundamental approach towards better understanding of possible diseases. However, conventional sampling methods, such as endoscopies or colonoscopies, are invasive and cannot reach the entire small intestine. To address this need, a battery-less 3D-printed sampling capsule, which can collect microbiome samples throughout the entirety of the GI tract was designed. The capsule (9 mm × 15 mm) consists of a 3D printed acrylic housing, a fast-absorbing hydrogel, and a flexible PDMS membrane. Fluids containing samples of the microbial flora within the GI tract enter the device through a sampling aperture on the cap of the device. Once the microbiome enters the housing, the hydrogel absorbs the fluid and swells, effectively protecting the samples within its polymeric matrix, while also pushing on the flexible PDMS membrane to block the sampling aperture from further fluid exchange. The retrieved capsule can be readily disassembled due to the screw-cap design of the capsule and the hydrogel can be removed for further bacterial culture and analysis. As a proof of concept, the capsule's bacterial sampling efficiency and the ability to host microbial samples within the hydrogel in a sealed capsule were validated using a liquid culture containing Escherichia coli. The demonstrated technology provides a promising inexpensive tool for direct sampling and assessment of microbes throughout the GI tract and can enable new insights into the role of diet in mediating host–microbe interactions and metabolism.