Carsten Hackenbroch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Carsten Hackenbroch has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Meinrad Beer
Department of Radiology, University Hospital of Ulm, Ulm, Baden-Wurttemberg, Germany
3 shared publicationsSimone Schüle
Department of Diagnostic and Interventional Radiology and Neuroradiology, German Armed Forces Hospital Ulm, Ulm, Baden-Wurttemberg, Germany
3 shared publications- Anne Köhler
Institute of Orthopaedic Research and Biomechanics, Trauma Research Center Ulm, Ulm University, Ulm, Germany
2 shared publications Daniel Halt
Department of Diagnostic and Interventional Radiology and Neuroradiology, German Armed Forces Hospital Ulm, Ulm
2 shared publications- Elisabeth Debout
Institute of Orthopaedic Research and Biomechanics, Trauma Research Center Ulm, Ulm University, Ulm, Germany
2 shared publications - Hans-Joachim Wilke
Institute of Orthopaedic Research and Biomechanics, Trauma Research Centre Ulm, University of Ulm, Ulm, Germany
2 shared publications
Latest Publications
- Open Access
- 10 July 2023
- Published by Springer Nature in Head & Face Medicine
- Vol. 19 (1) , 1-12
Dose development in sinonasal imaging over the last decade – a retrospective patient study
Computed tomography (CT) has become the primary imaging modality for visualization of the paranasal sinuses. In this retrospective, single center patient study the radiation dose development in the past 12 years in CT imaging of the paranasal sinuses was assessed. The computed tomography dose index (CTDIVol) and dose length product (DLP) of a total of 1246 patients (average age: 41 ± 18 years, 361 females, 885 males) were evaluated, who received imaging of the paranasal sinuses either for chronic sinusitis diagnostic, preoperatively or posttraumatically. Scans were performed on three different CT scanners (Somatom Definition AS, Somatom Definition AS+, Somatom Force, all from Siemens Healthineers) and on one CBCT (Morita) ranging from 2010 to 2022. Reconstruction techniques were filtered back projection and three generations of iterative reconstruction (IRIS, SAFIRE, ADMIRE, all from Siemens Healthineers). Group comparisons were performed using either parametrical (ANOVA) or non-parametrical tests (Kruskal-Wallis Test), where applicable. Over the past 12 years, there was a 73%, 54%, and 66% CTDIVol reduction and a significant (p < 0.001) 72%, 33%, and 67% DLP reduction in assessing the paranasal sinuses for chronic sinusitis, preoperatively and posttraumatically, respectively. Technological developments in CT imaging, both hardware and software based, have led to a significant reduction in dose exposure in recent years. Particularly in imaging of the paranasal sinuses, the reduction of radiation exposure is of great interest due to the often young patient age and radiation-sensitive organs in the area of radiation exposure.
- 10 July 2023
- Published by Springer Nature in Head & Face Medicine
- Vol. 19 (1) , 1-12
Open AccessDose development in sinonasal imaging over the last decade – a retrospective patient study
Computed tomography (CT) has become the primary imaging modality for visualization of the paranasal sinuses. In this retrospective, single center patient study the radiation dose development in the past 12 years in CT imaging of the paranasal sinuses was assessed. The computed tomography dose index (CTDIVol) and dose length product (DLP) of a total of 1246 patients (average age: 41 ± 18 years, 361 females, 885 males) were evaluated, who received imaging of the paranasal sinuses either for chronic sinusitis diagnostic, preoperatively or posttraumatically. Scans were performed on three different CT scanners (Somatom Definition AS, Somatom Definition AS+, Somatom Force, all from Siemens Healthineers) and on one CBCT (Morita) ranging from 2010 to 2022. Reconstruction techniques were filtered back projection and three generations of iterative reconstruction (IRIS, SAFIRE, ADMIRE, all from Siemens Healthineers). Group comparisons were performed using either parametrical (ANOVA) or non-parametrical tests (Kruskal-Wallis Test), where applicable. Over the past 12 years, there was a 73%, 54%, and 66% CTDIVol reduction and a significant (p < 0.001) 72%, 33%, and 67% DLP reduction in assessing the paranasal sinuses for chronic sinusitis, preoperatively and posttraumatically, respectively. Technological developments in CT imaging, both hardware and software based, have led to a significant reduction in dose exposure in recent years. Particularly in imaging of the paranasal sinuses, the reduction of radiation exposure is of great interest due to the often young patient age and radiation-sensitive organs in the area of radiation exposure.
- 29 June 2022
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 57 (12) , 789-801
Low-Dose CT Imaging of the Pelvis in Follow-up Examinations—Significant Dose Reduction and Impact of Tin Filtration
Objectives: Low-dose (LD) computed tomography (CT) is still rarely used in musculoskeletal (MSK) radiology. This study evaluates the potentials of LD CT for follow-up pelvic imaging with special focus on tin filtration (Sn) technology for normal and obese patients with and without metal implants. Materials and Methods: In a phantom study, 5 different LD and normal-dose (ND) CT protocols with and without tin filtration were tested using a normal and an obese phantom. Iterative reconstruction (IR) and filtered back projection (FBP) were used for CT image reconstruction. In a subsequent retrospective patient study, ND CT images of 45 patients were compared with follow-up tin-filtered LD CT images with a 90% dose reduction. Sixty-four percent of patients contained metal implants at the follow-up examination. Computed tomography images were objectively (image noise, contrast-to-noise ratio [CNR], dose-normalized contrast-to-noise ratio [CNRD]) and subjectively, using a 6-point Likert score, evaluated. In addition, the figure of merit was calculated. For group comparisons, paired t tests, Wilcoxon signed rank test, analysis of variance, or Kruskal-Wallis tests were used, where applicable. Results: The LD Sn protocol with 67% dose reduction resulted in equal values in qualitative (Likert score) and quantitative image analysis (image noise) compared with the ND protocol in the phantom study. For follow-up examinations, dose could be reduced up to 90% by using Sn LD CT scans without impairment in the clinical study. However, metal implants resulted in a mild impairment of Sn LD as well as ND CT images. Cancellous bone (P < 0.001) was assessed worse and cortical bone (P = 0.063) equally in Sn LD CT images compared with ND CT images. Figure of merit values were significant (P ≤ 0.02) lower and hence better in Sn LD as in ND protocols. Obese patients benefited in particular from tin filtration in LD MSK imaging in terms of image noise and CNR (P ≤ 0.05). Conclusions: Low-dose CT scans with tin filtration allow maximum dose reduction while maintaining high image quality for certain clinical purposes, for example, follow-up examinations, especially metal implant position, material loosening, and consolidation controls. Overweight patients benefit particularly from tin filter technology. Although metal implants decrease image quality in ND as well as in Sn LD CT images, this is not a relevant limitation for assessability.
- 29 June 2022
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 57 (12) , 789-801
Low-Dose CT Imaging of the Pelvis in Follow-up Examinations—Significant Dose Reduction and Impact of Tin Filtration
Objectives: Low-dose (LD) computed tomography (CT) is still rarely used in musculoskeletal (MSK) radiology. This study evaluates the potentials of LD CT for follow-up pelvic imaging with special focus on tin filtration (Sn) technology for normal and obese patients with and without metal implants. Materials and Methods: In a phantom study, 5 different LD and normal-dose (ND) CT protocols with and without tin filtration were tested using a normal and an obese phantom. Iterative reconstruction (IR) and filtered back projection (FBP) were used for CT image reconstruction. In a subsequent retrospective patient study, ND CT images of 45 patients were compared with follow-up tin-filtered LD CT images with a 90% dose reduction. Sixty-four percent of patients contained metal implants at the follow-up examination. Computed tomography images were objectively (image noise, contrast-to-noise ratio [CNR], dose-normalized contrast-to-noise ratio [CNRD]) and subjectively, using a 6-point Likert score, evaluated. In addition, the figure of merit was calculated. For group comparisons, paired t tests, Wilcoxon signed rank test, analysis of variance, or Kruskal-Wallis tests were used, where applicable. Results: The LD Sn protocol with 67% dose reduction resulted in equal values in qualitative (Likert score) and quantitative image analysis (image noise) compared with the ND protocol in the phantom study. For follow-up examinations, dose could be reduced up to 90% by using Sn LD CT scans without impairment in the clinical study. However, metal implants resulted in a mild impairment of Sn LD as well as ND CT images. Cancellous bone (P < 0.001) was assessed worse and cortical bone (P = 0.063) equally in Sn LD CT images compared with ND CT images. Figure of merit values were significant (P ≤ 0.02) lower and hence better in Sn LD as in ND protocols. Obese patients benefited in particular from tin filtration in LD MSK imaging in terms of image noise and CNR (P ≤ 0.05). Conclusions: Low-dose CT scans with tin filtration allow maximum dose reduction while maintaining high image quality for certain clinical purposes, for example, follow-up examinations, especially metal implant position, material loosening, and consolidation controls. Overweight patients benefit particularly from tin filter technology. Although metal implants decrease image quality in ND as well as in Sn LD CT images, this is not a relevant limitation for assessability.
- 2 September 2021
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 57 (3) , 194-203
Metal Artifact Reduction With Tin Prefiltration in Computed Tomography
Objectives: With the aging population and thus rising numbers of orthopedic implants (OIs), metal artifacts (MAs) increasingly pose a problem for computed tomography (CT) examinations. In the study presented here, different MA reduction techniques (iterative metal artifact reduction software [iMAR], tin prefilter technique, and dual-energy CT [DECT]) were compared. Materials and Methods: Four human cadaver pelvises with OIs were scanned on a third-generation DECT scanner using tin prefilter (Sn), dual-energy (DE), and conventional protocols. Virtual monoenergetic CT images were generated from DE data sets. Postprocessing of CT images was performed using iMAR. Qualitative (bony structures, MA, image noise) image analysis using a 6-point Likert scale and quantitative image analysis (contrast-to-noise ratio, standard deviation of background noise) were performed by 2 observers. Statistical testing was performed using Friedman test with Nemenyi test as a post hoc test. Results: The iMAR Sn 150 kV protocol provided the best overall assessability of bony structures and the lowest subjective image noise. The iMAR DE protocol and virtual monochromatic image (VMI) ± iMAR achieved the most effective metal artifact reduction (MAR) (P < 0.05 compared with conventional protocols). Bony structures were rated worse in VMI ± iMAR (P < 0.05) than in tin prefilter protocols ± iMAR. The DE protocol ± iMAR had the lowest contrast-to-noise ratio (P < 0.05 compared with iMAR standard) and the highest image noise (P < 0.05 compared with iMAR VMI). The iMAR reduced MA very efficiently. Conclusions: When considering MAR and image quality, the iMAR Sn 150 kV protocol performed best overall in CT images with OI. The iMAR generated new artifacts that impaired image quality. The DECT/VMI reduced MA best, but experienced from a lack of resolution of bony fine structures.
- 2 September 2021
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 57 (3) , 194-203
Metal Artifact Reduction With Tin Prefiltration in Computed Tomography
Objectives: With the aging population and thus rising numbers of orthopedic implants (OIs), metal artifacts (MAs) increasingly pose a problem for computed tomography (CT) examinations. In the study presented here, different MA reduction techniques (iterative metal artifact reduction software [iMAR], tin prefilter technique, and dual-energy CT [DECT]) were compared. Materials and Methods: Four human cadaver pelvises with OIs were scanned on a third-generation DECT scanner using tin prefilter (Sn), dual-energy (DE), and conventional protocols. Virtual monoenergetic CT images were generated from DE data sets. Postprocessing of CT images was performed using iMAR. Qualitative (bony structures, MA, image noise) image analysis using a 6-point Likert scale and quantitative image analysis (contrast-to-noise ratio, standard deviation of background noise) were performed by 2 observers. Statistical testing was performed using Friedman test with Nemenyi test as a post hoc test. Results: The iMAR Sn 150 kV protocol provided the best overall assessability of bony structures and the lowest subjective image noise. The iMAR DE protocol and virtual monochromatic image (VMI) ± iMAR achieved the most effective metal artifact reduction (MAR) (P < 0.05 compared with conventional protocols). Bony structures were rated worse in VMI ± iMAR (P < 0.05) than in tin prefilter protocols ± iMAR. The DE protocol ± iMAR had the lowest contrast-to-noise ratio (P < 0.05 compared with iMAR standard) and the highest image noise (P < 0.05 compared with iMAR VMI). The iMAR reduced MA very efficiently. Conclusions: When considering MAR and image quality, the iMAR Sn 150 kV protocol performed best overall in CT images with OI. The iMAR generated new artifacts that impaired image quality. The DECT/VMI reduced MA best, but experienced from a lack of resolution of bony fine structures.
- Open Access
- 27 May 2020
- Published by Springer Nature in European Spine Journal
- Vol. 29 (7) , 1785
Correction to: Nucleus replacement could get a new chance with annulus closure
Unfortunately, Fig. 7 and last paragraph of the result section have been incorrectly published. The complete corrected Fig. 7 and last paragraph
- 27 May 2020
- Published by Springer Nature in European Spine Journal
- Vol. 29 (7) , 1785
Open AccessCorrection to: Nucleus replacement could get a new chance with annulus closure
Unfortunately, Fig. 7 and last paragraph of the result section have been incorrectly published. The complete corrected Fig. 7 and last paragraph
- Open Access
COVID-19-induced acute respiratory failure – an exacerbation of organ-specific autoimmunity?
Background: Understanding the pathophysiology of respiratory failure (ARDS) in coronavirus disease 2019 (COVID-19) patients is of utmost importance for the development of therapeutic strategies and identification of risk factors. Since we observed clinical and histopathological similarities between COVID-19 and lung manifestations of connective tissue disease (CTD-ILD) in our clinical practice, aim of the present study is to analyze a possible role of autoimmunity in SARS-CoV-2-associated respiratory failure. Methods: In this prospective, single-center trial, we enrolled 22 consecutive patients with RT-PCR-confirmed SARS-CoV-2 infection hospitalized in March and April, 2020. We performed high-resolution computed tomography (HR-CT) and full laboratory testing including autoantibody (AAB) screening (anti-ANA, SS-B/La, Scl-70, Jo-1, CENP-B, PM-Scl). Transbronchial biopsies as well as post mortem tissue samples were obtained from 3 and 2 cases, respectively, and subsequent histopathologic analysis with special emphasis on characterization of interstitial lung disease was performed. Results: Twelve of 22 patients (54.5%) were male and median age was 69.0 (range: 28-88). 11 (50.0%) patients had to be undergo intensive care unit (ICU) treatment. Intubation with ventilation was required in 10/22 cases (46%). Median follow-up was 26 days. Clinical and serological parameters were comparable to previous reports. Radiological and histopathological findings were highly heterogeneous including patterns reminiscent of CTD-ILD. AAB titers ≥1:100 were detected in 10/11 (91.9%) COVID-19 patients who required ICU treatment, but in 4/11 (36.4%) patients with mild clinical course (p=0.024). Patients with AABs tended to require invasive ventilation and showed significantly more severe complications (64.3% vs. 12.5%, p=0.031). Overall COVID-19-related mortality was 18.2% among hospitalized patients at our institution. Conclusion: Our findings point out serological, radiological and histomorphological similarities between COVID-19-associated ARDS and acute exacerbation of CTD-ILD. While the exact mechanism is still unknown, we postulate that SARS-CoV-2 infection might trigger or simulate a form of organ-specific autoimmunity in predisposed patients. The detection of autoantibodies might identify patients who profit from immunosuppressive therapy to prevent the development of respiratory failure.
Open AccessCOVID-19-induced acute respiratory failure – an exacerbation of organ-specific autoimmunity?
Background: Understanding the pathophysiology of respiratory failure (ARDS) in coronavirus disease 2019 (COVID-19) patients is of utmost importance for the development of therapeutic strategies and identification of risk factors. Since we observed clinical and histopathological similarities between COVID-19 and lung manifestations of connective tissue disease (CTD-ILD) in our clinical practice, aim of the present study is to analyze a possible role of autoimmunity in SARS-CoV-2-associated respiratory failure. Methods: In this prospective, single-center trial, we enrolled 22 consecutive patients with RT-PCR-confirmed SARS-CoV-2 infection hospitalized in March and April, 2020. We performed high-resolution computed tomography (HR-CT) and full laboratory testing including autoantibody (AAB) screening (anti-ANA, SS-B/La, Scl-70, Jo-1, CENP-B, PM-Scl). Transbronchial biopsies as well as post mortem tissue samples were obtained from 3 and 2 cases, respectively, and subsequent histopathologic analysis with special emphasis on characterization of interstitial lung disease was performed. Results: Twelve of 22 patients (54.5%) were male and median age was 69.0 (range: 28-88). 11 (50.0%) patients had to be undergo intensive care unit (ICU) treatment. Intubation with ventilation was required in 10/22 cases (46%). Median follow-up was 26 days. Clinical and serological parameters were comparable to previous reports. Radiological and histopathological findings were highly heterogeneous including patterns reminiscent of CTD-ILD. AAB titers ≥1:100 were detected in 10/11 (91.9%) COVID-19 patients who required ICU treatment, but in 4/11 (36.4%) patients with mild clinical course (p=0.024). Patients with AABs tended to require invasive ventilation and showed significantly more severe complications (64.3% vs. 12.5%, p=0.031). Overall COVID-19-related mortality was 18.2% among hospitalized patients at our institution. Conclusion: Our findings point out serological, radiological and histomorphological similarities between COVID-19-associated ARDS and acute exacerbation of CTD-ILD. While the exact mechanism is still unknown, we postulate that SARS-CoV-2 infection might trigger or simulate a form of organ-specific autoimmunity in predisposed patients. The detection of autoantibodies might identify patients who profit from immunosuppressive therapy to prevent the development of respiratory failure.
- Open Access
- 24 April 2020
- Published by Springer Nature in European Spine Journal
- Vol. 29 (7) , 1733-1741
Nucleus replacement could get a new chance with annulus closure
Purpose: Disc herniations are usually treated by decompression of the spinal nerves via a partial nucleotomy. As a consequence of reduced disc height (DH), reduced intradiscal pressure (IDP) and increased range of motion (ROM), accelerated degeneration may occur. Nucleus replacement implants are intended to restore those values, but are associated with the risk of extrusion. Methods: In six fresh frozen lumbar spinal segments (L2-3/L3-4/L4-5/L5-S1, age median 64.5 years (57–72), Pfirrmann grade 2–3), a prolapse was provoked through a box defect (6 × 10 mm) in the annulus. The herniated nucleus material was removed and replaced by a novel collagen-based nucleus implant. An annulus closure device sealed the defect. ROM, neutral zone (NZ) and IDP were measured in the (1) intact and (2) defect state, (3) postoperatively and (4) after cyclic loading (n = 100,000 cycles) applying pure moments (± 7.5 Nm) in flexion–extension, lateral bending and axial rotation. Additionally, the change in DH was determined. Extrusion of implants or nucleus material was evaluated macroscopically. Results: In all specimens, a prolapse could be provoked which decreased DH. Subsequent nucleotomy changed ROM/NZ and IDP considerably. Initial values could be restored by the implantation. Macroscopically, none of the implants nor nucleus material did migrate after cyclic loading. Conclusions: In this study, a prolapse followed by a nucleotomy resulted in a biomechanical destabilisation. Implantation of the nucleus replacement combined with an annulus closure restored the intact condition without showing signs of extrusion nor migration after cyclic loading. Hence, nucleus replacements could have a new chance in combination with annulus closure devices.
- 24 April 2020
- Published by Springer Nature in European Spine Journal
- Vol. 29 (7) , 1733-1741
Open AccessNucleus replacement could get a new chance with annulus closure
Purpose: Disc herniations are usually treated by decompression of the spinal nerves via a partial nucleotomy. As a consequence of reduced disc height (DH), reduced intradiscal pressure (IDP) and increased range of motion (ROM), accelerated degeneration may occur. Nucleus replacement implants are intended to restore those values, but are associated with the risk of extrusion. Methods: In six fresh frozen lumbar spinal segments (L2-3/L3-4/L4-5/L5-S1, age median 64.5 years (57–72), Pfirrmann grade 2–3), a prolapse was provoked through a box defect (6 × 10 mm) in the annulus. The herniated nucleus material was removed and replaced by a novel collagen-based nucleus implant. An annulus closure device sealed the defect. ROM, neutral zone (NZ) and IDP were measured in the (1) intact and (2) defect state, (3) postoperatively and (4) after cyclic loading (n = 100,000 cycles) applying pure moments (± 7.5 Nm) in flexion–extension, lateral bending and axial rotation. Additionally, the change in DH was determined. Extrusion of implants or nucleus material was evaluated macroscopically. Results: In all specimens, a prolapse could be provoked which decreased DH. Subsequent nucleotomy changed ROM/NZ and IDP considerably. Initial values could be restored by the implantation. Macroscopically, none of the implants nor nucleus material did migrate after cyclic loading. Conclusions: In this study, a prolapse followed by a nucleotomy resulted in a biomechanical destabilisation. Implantation of the nucleus replacement combined with an annulus closure restored the intact condition without showing signs of extrusion nor migration after cyclic loading. Hence, nucleus replacements could have a new chance in combination with annulus closure devices.