SMSriHari Mahadev

SriHari Mahadev

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


SriHari Mahadev has a total of 110 co-authors. Here are the top co-authors by number of shared publications:

  • Reem Z. Sharaiha

    Division of Gastroenterology and Hepatology, Department of Medicine, Weill Cornell Medicine, New York, New York, USA

    10 shared publications
  • Kartik Sampath

    Weill Cornell Medical College, New York, NY, USA; Division of Gastroenterology and Hepatology, New York-Presbyterian Hospital/Weill Cornell Medicine, New York, New York, USA

    6 shared publications
  • David L. Carr-Locke

    Weill Cornell Medical College, New York, NY, USA; Division of Gastroenterology and Hepatology, New York-Presbyterian Hospital/Weill Cornell Medicine, New York, New York, USA

    5 shared publications
  • Patrick Tiongco Magahis

    Department of Medicine, Brigham and Women's Hospital, Boston, Massachusetts, USA; Division of Gastroenterology, Hepatology and Endoscopy, Brigham and Women's Hospital, Boston, Massachusetts, USA

    5 shared publications
  • Carolyn Newberry

    Division of Gastroenterology Weill Cornell Medical Center New York New York USA

    4 shared publications
  • David L. Carr-Locke

    Center for Advanced Digestive Care, New York Presbyterian Hospital, New York, NY, USA; Department of Gastroenterology and Hepatology, Weill Cornell Medicine, New York, NY, USA

    4 shared publications

Latest Publications

  • Effects of Endoscopic Sleeve Gastroplasty on Body Composition and Metabolism: An InBody Analysis

    by Ali Lahooti, Zane Gouda, Sean Rangwani, Kate E. Johnson, Qusai Al Zureikat, Chino Aneke-Nash, Adeyinka Adejumo, Muhammad Usman Baig, Dominque Gay, Adam Buckholz, et al.

    Introduction and Aim Despite ESG's efficacy in promoting weight loss, data on its impact on body composition is limited. This study evaluated ESG's effectiveness in improving body composition and metabolic parameters over 6 and 12 months using InBody analysis. Methods We prospectively analyzed patients with obesity (BMI > 30 kg/m2 or > 27 with comorbidities) who underwent ESG between August 2021 and May 2024. Body composition was assessed via bioelectrical impedance analysis (InBody 770™). Results Thirty-six patients (81% female, mean age 47.9 ± 13.4 years, BMI 35.3 ± 5.6 kg/m2) completed baseline assessment. Follow-up rates were 67% at 6 months and 61% at 12 months. ESG produced significant reductions in BMI (4.6 and 4.8 kg/m2) and total body weight loss (13.4% and 13.5%) at both timepoints (p < 0.001). Body fat percentage decreased by 4.7% at 6 months, with truncal fat loss of 4.0 kg comprising 32% of total weight loss. These improvements persisted at 12 months (p < 0.01). While skeletal muscle mass also declined, muscle loss represented only 13–17% of total weight loss. Discussion ESG achieves substantial weight loss with preferential fat reduction and favorable preservation of lean body mass over 12 months, supporting its role in improving metabolic health.

  • Comparing Weight Loss and Metabolic Outcomes of Virtual Versus In-Person Follow-Up Care in Bariatrics: A Propensity-Matched Analysis at 12 and 36 Months Post-ESG

    by Ali Lahooti, Kate E. Johnson, Chino Aneke-Nash, Qusai Al Zureikat, Muhammad U. Baig, Mark Hanscom, Adam Buckholz, Robert E. Schwartz, Carolyn Newberry, Kartik Sampath, et al.

    Introduction The rising prevalence of obesity and demand for minimally invasive treatments has led to increased adoption of endoscopic sleeve gastroplasty (ESG). As telemedicine expands in bariatrics, understanding the role of virtual follow-up care is crucial. This study aims to use propensity-matching to compare weight loss and metabolic outcomes between virtual and in-person follow-up modalities post-ESG. Methods Data from patients with obesity who underwent ESG at a single tertiary care center between August 2013 and November 2024 were prospectively collected and retrospectively analyzed. Eligible patients were those with a body mass index (BMI) of 30 kg/m2 or greater (or > 27 kg/m2 with comorbidities). All procedures were performed by a single therapeutic endoscopist using a full-thickness technique. Patients were categorized into virtual or in-person follow-up groups based on whether over 70% of their post-procedure visits were conducted virtually or in-person, respectively. To account for potential baseline differences, propensity score matching was employed. The primary outcomes assessed were the impact of follow-up method on percent total body weight loss (%TBWL) and changes in metabolic parameters at 12 and 36 months post-ESG. Results Data from 113 patients (mean age, 43.9 years; 80.5% female, BMI 36.0 kg/m2), were analyzed, and stratified by follow-up modality (in-person: n = 54, virtual: n = 59). After propensity matching, baseline differences were eliminated and both groups demonstrated improvements in ALT, HbA1c, LDL, TG, SBP, and mean %TBWL exceeding ten at all time points, with no statistically significant differences between groups at 12 or 36 months. Discussion Telemedicine is expected to remain in the management of obesity due to its convenience. This study found no significant differences in weight loss or metabolic changes between propensity-matched groups, demonstrating comparable effectiveness of virtual and in-person follow-up. Future research should refine telemedicine strategies and assess their long-term impact on weight maintenance.


  • Outcomes of Endoscopic ultrasound–guided liver biopsy using 22-gauge versus 19-gauge needles with a novel hydrostatic sampling technique

    by Patrick T. Magahis, Erika Hissong, Mark Hanscom, David L. Carr-Locke, Kartik Sampath, Reem Z. Sharaiha, SriHari Mahadev


  • Endoscopic Sleeve Gastroplasty for the Treatment of Metabolic Syndrome: A Systematic Review and Meta-analysis

    by Mark Hanscom, Muhammad Usman Baig, Drew Wright, Laith Baqain, Kate Elise Johnson, Vivek Kumbhari, Shelby Sullivan, Barham Abu Dayyeh, SriHari Mahadev, Carolyn Newberry, et al.

    Background Endoscopic sleeve gastroplasty (ESG) is an incisionless weight loss procedure that has been demonstrated to be safe and effective for the treatment of obesity; however, the efficacy of ESG for the treatment of comorbid type 2 diabetes mellitus (T2DM) and other components of metabolic syndrome (MetS) has been less well studied. We aimed to conduct a systematic review and meta-analysis of available literature to evaluate the outcomes of ESG on T2DM and MetS. Methods Bibliographic databases were systematically searched for studies assessing the outcomes of ESG on T2DM and MetS. Studies were included if they reported at least one objective outcome related to T2DM or other components of MetS, including hyperlipidemia (HLD), hypertriglyceridemia, and hypertension (HTN). This study was deemed IRB exempt. Results Ten studies with 4320 patients were included. At 12 months, ESG was associated with significant improvements in T2DM, HLD, and HTN, with risk difference of − 0.72 [95% CI, − 0.87 to − 0.58, p < 0.00001], − 0.65 [95% CI, − 0.78 to − 0.52, p < 0.00001], and − 0.60 [95% CI, − 0.66 to − 0.53, p < 0.00001], respectively. Disease improvement was defined as patients being able to stop some or all of their related treatment medications. Additionally, there were significant reductions in hemoglobin A1c (HGBA1c), fasting blood glucose, homeostatic model assessment for insulin resistance (HOMA-IR), low-density lipoprotein, and triglycerides. Conclusions ESG is an effective modality for the treatment of comorbid T2DM and MetS in patients with obesity. Additional studies are needed to establish long-term responses and to compare ESG against established pharmacologic and surgical techniques. Graphical Abstract


  • Open Access

    EUS-guided hepaticojejunostomy for biliary obstruction in near-total gastrectomy with Roux-en-Y: Trials and tribulations (with videos)

    by Jeong Hoon Kim, Jade Wang, Kamal M. Hassan, Reem Z. Sharaiha, Srihari Mahadev, Kartik Sampath


  • Risk of Pancreatitis After Endoscopic Ultrasound-Guided Fine-Needle Aspiration of Pancreatic Cystic Lesions: A Systematic Review and Meta-Analysis

    by Patrick T. Magahis, Ankit Chhoda, Tyler M. Berzin, James J. Farrell, Drew N. Wright, Anam Rizvi, Mark Hanscom, David L. Carr-Locke, Kartik Sampath, Reem Z. Sharaiha, et al.

    INTRODUCTION: Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is frequently used to risk-stratify pancreatic cystic lesions (PCLs). Rising PCL incidence and developments in tissue acquisition and specimen analysis necessitate updated appraisal of EUS-FNA safety, particularly the risk of postprocedure pancreatitis, the most common EUS-FNA-related adverse event. Our systematic review aims to accurately quantify the risk of EUS-FNA-related pancreatitis to best inform decisions regarding EUS-FNA's optimal role in PCL workup. METHODS: We performed systematic searches in 4 databases from inception to April 2024 for original English-language studies investigating EUS-FNA-related pancreatitis. We extracted data on demographics and EUS-FNA-related pancreatitis risk, severity, and risk factors. These were meta-analyzed through the DerSimonian Laird Method using a random-effects model. Meta-regression of pancreatitis risk was performed to delineate associations with clinical and procedural characteristics. RESULTS: Sixty-four studies comprised 8,086 patients and reported 110 EUS-FNA-related pancreatitis events. Pooled risk of EUS-FNA-related pancreatitis was 1.4% (95% confidence intervals, −0.8% to 3.5%; I 2 = 0.00), which was predominantly of mild severity (67%) and uniformly nonfatal. Pancreatitis risk lacked significant association with sample size, age, sex, cyst size, needle caliber, or passes, although we noted trends toward higher risk in studies published after 2015, those using higher gauge needles (19 G vs 22 G/25 G), and those performing EUS-guided through-the-needle biopsy. DISCUSSION: We note with high certainty that pancreatitis after EUS-FNA of PCLs is infrequent and mild in severity with no mortality in the included cohort. EUS-guided through-the-needle biopsy may serve as a significant risk factor for EUS-FNA-related pancreatitis risk; however, further studies are needed to delineate other predisposing characteristics.


  • Outcomes of Endoscopic Ultrasound-guided Fine Needle Biopsy Using a Novel Hydrostatic Stylet Tissue Acquisition Technique

    by Patrick T. Ba Magahis, Donevan Westerveld, Malorie Simons, David L. Carr-Locke, Kartik Sampath, Reem Z. Md Sharaiha, SriHari Mahadev

    Background: Endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) is frequently used to obtain core samples of solid lesions. Here, we describe and evaluate a novel hydrostatic stylet (HS) technique designed to optimize core sample acquisition, reporting diagnostic yield, efficacy, and safety relative to the conventional stylet slow-pull (SP) technique. Methods: A novel HS technique was developed and validated retrospectively. Consecutive patients who underwent EUS-FNB with core biopsy of solid lesions through either the HS or SP technique between January 2020 and April 2022 were included. Exclusion criteria included cystic lesions, nonlesional liver biopsies, and specimens sent for cytologic analysis only. Patient and lesion characteristics, number of passes, sample adequacy, and adverse events were compared between the two techniques. Results: A total of 272 patients were included with 138 in the HS group and 134 in the SP group. Lesion size and anatomic distribution were similar in both groups. Compared with the SP approach, the HS technique demonstrated significantly higher sample adequacy (97.8% vs 83.6%, P < 0.001), higher sensitivity (97.1% vs 89.7%, P = 0.03), and lower mean number of passes (1.2 vs 3.3, P < 0.001). Rates and severity of adverse events in the HS group were comparable to the SP group and existing literature. Similar associations were observed in pancreatic and nonpancreatic lesion subanalyses. Conclusions: The novel HS technique demonstrated excellent biopsy sample adequacy and diagnostic yield while requiring fewer passes to obtain diagnostic specimens compared with a conventional EUS-FNB approach. Further prospective evaluation is needed to confirm these pilot findings and optimize EUS-FNB acquisition techniques.


  • Open Access

    Preferred techniques for endoscopic ultrasound-guided gastroenterostomy: a survey of expert endosonographers

    by Patrick T. Magahis, Sanjay Salgado, Donevan Westerveld, Enad Dawod, David L. Carr-Locke, Kartik Sampath, Reem Z. Sharaiha, Srihari Mahadev

    Background and study aims Endoscopic ultrasound-guided gastroenterostomy (EUS-GE) is an emerging procedure that lacks technical standardization with limited adoption beyond expert centers. We surveyed high-volume endosonographers about the technical aspects of EUS-GE to describe how the procedure is currently performed at expert centers and identify targets for standardization. Methods Invitations to complete an electronic survey were distributed to 21 expert EUS practitioners at 19 U.S. centers. Respondents were surveyed about technical aspects of EUS-GE, indications, efficacy, safety, and attitudes toward the procedure. Results All 21 (100%) invited expert endoscopists completed the survey. Nine (42.9%) reported performing >10 EUS-GEs in the last 12 months. About half (47.6%, 10/21) puncture the target loop prior to lumen-apposing metal stent (LAMS) introduction, most often to confirm the loop is jejunum. No respondents reported guidewire placement prior to LAMS introduction. Most (71.4%, 15/21) do not use a guidewire at any time, while 28.6% (6/21) reported wire placement after distal flange deployment to secure the tract during apposition. Eight (38.1%, 8/21) reported at least one major adverse event, most commonly intraperitoneal LAMS deployment (87.5%, 7/8). Factors most often reported as advantageous for EUS-GE over enteral stenting included lack of papilla interference (33.3%, 7/21) and decreased occlusion risk (23.8%, 5/21). Conclusions Significant variation in performance technique for EUS-GE exists among expert US endoscopists, which may hinder widespread adoption and contribute to inconsistencies in reported patient outcomes. The granularity provided by these survey results may identify areas to focus standardization efforts and guide future studies on developing an ideal EUS-GE protocol.


  • Mo1950 ““THE REYNOLDS-MCELHENNEY EFFECT?”: THE EFFECT OF CELEBRITY ENDORSEMENT ON COLONOSCOPY-RELATED VIDEOS ON TIKTOK

    by Ali Lahooti, Brian Critelli, Amier Hassan, Donevan R. Westerveld, Lindsay Rogers, Maryam Gazi, Enad Dawod, SriHari Mahadev, Sonal Kumar, Carolyn Newberry, et al.

  • A surprising culprit for delayed gastrointestinal bleeding after endoscopic ultrasound-guided cholecystoduodenostomy: the double-pigtail stent

    by Patrick Tiongco Magahis, Donevan Westerveld, Malorie Simons, SriHari Mahadev

    Endoscopic ultrasound-guided gallbladder drainage using a lumen-apposing metal stent has emerged as an accepted option for the treatment of acute cholecystitis in patients unfit for surgery. While metal stents carry a risk of intra- and post-procedural bleeding, the coaxial placement of a double-pigtail stents through lumen-apposing metal stents has been proposed to lower the bleeding risk by preventing tissue abrasion against the stent flanges. We present a case of an 83 year-old male who had previously undergone uncomplicated endoscopic ultrasound-guided cholecystoduodenostomy with this technique. Six months later, he presented with upper gastrointestinal bleeding due to a duodenal pressure ulcer from the coaxial 10-Fr double-pigtail stent originally employed to prevent such bleeding. The 10-Fr stent was replaced with two 7-Fr stents whose increased flexibility and distribution of pressure across multiple points of contact with the duodenal wall was theorized to reduce the likelihood of erosion or perforation. Following the procedure, the patient’s clinical course improved significantly with complete resolution of his symptoms of choledocholithiasis and cholecystitis. While 10-Fr double-pigtail stents are generally preferred for this indication due to their stiffness that reduces out-migration, use of more flexible 7-Fr stents may be advisable in thin-walled structures such as the duodenum.