Sofian N. Obaid
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sofian N. Obaid has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Igor R. Efimov
Department of Biomedical Engineering, Northwestern University, Chicago, USA
4 shared publications - Luyao Lu
Department of Biomedical Engineering, The George Washington University
3 shared publications - Zhiyuan Chen
Department of Biomedical Engineering, The George Washington University, Washington, DC 20052, USA
3 shared publications Alana N. Miniovich
Department of Biomedical Engineering The George Washington University Washington DC 20052 USA
2 shared publications- Jessica LaPiano
MedStar Georgetown University Hospital, Washington, DC 20037, USA
2 shared publications Nicolas Boyajian
Department of Biomedical Engineering The George Washington University Washington DC 20052 USA
2 shared publications
Latest Publications
- Open Access
- 7 July 2023
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 9 (27) , eadi0757
Soft, bioresorbable, transparent microelectrode arrays for multimodal spatiotemporal mapping and modulation of cardiac physiology
Transparent microelectrode arrays (MEAs) that allow multimodal investigation of the spatiotemporal cardiac characteristics are important in studying and treating heart disease. Existing implantable devices, however, are designed to support chronic operational lifetimes and require surgical extraction when they malfunction or are no longer needed. Meanwhile, bioresorbable systems that can self-eliminate after performing temporary functions are increasingly attractive because they avoid the costs/risks of surgical extraction. We report the design, fabrication, characterization, and validation of a soft, fully bioresorbable, and transparent MEA platform for bidirectional cardiac interfacing over a clinically relevant period. The MEA provides multiparametric electrical/optical mapping of cardiac dynamics and on-demand site-specific pacing to investigate and treat cardiac dysfunctions in rat and human heart models. The bioresorption dynamics and biocompatibility are investigated. The device designs serve as the basis for bioresorbable cardiac technologies for potential postsurgical monitoring and treating temporary patient pathological conditions in certain clinical scenarios, such as myocardial infarction, ischemia, and transcatheter aortic valve replacement.
- 7 July 2023
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 9 (27) , eadi0757
Open AccessSoft, bioresorbable, transparent microelectrode arrays for multimodal spatiotemporal mapping and modulation of cardiac physiology
Transparent microelectrode arrays (MEAs) that allow multimodal investigation of the spatiotemporal cardiac characteristics are important in studying and treating heart disease. Existing implantable devices, however, are designed to support chronic operational lifetimes and require surgical extraction when they malfunction or are no longer needed. Meanwhile, bioresorbable systems that can self-eliminate after performing temporary functions are increasingly attractive because they avoid the costs/risks of surgical extraction. We report the design, fabrication, characterization, and validation of a soft, fully bioresorbable, and transparent MEA platform for bidirectional cardiac interfacing over a clinically relevant period. The MEA provides multiparametric electrical/optical mapping of cardiac dynamics and on-demand site-specific pacing to investigate and treat cardiac dysfunctions in rat and human heart models. The bioresorption dynamics and biocompatibility are investigated. The device designs serve as the basis for bioresorbable cardiac technologies for potential postsurgical monitoring and treating temporary patient pathological conditions in certain clinical scenarios, such as myocardial infarction, ischemia, and transcatheter aortic valve replacement.
- Open Access
- 17 April 2023
- Published by Wiley in Advanced Materials
- Vol. 35 (22) , e2212190
Graphene Biointerface for Cardiac Arrhythmia Diagnosis and Treatment
Heart rhythm disorders, known as arrhythmias, cause significant morbidity and are one of the leading causes of mortality. Cardiac arrhythmias are frequently treated by implantable devices, such as pacemakers and defibrillators, or by ablation therapy guided by electroanatomical mapping. Both implantable and ablation therapies require sophisticated biointerfaces for electrophysiological measurements of electrograms and delivery of therapeutic stimulation or ablation energy. In this work, a graphene biointerface for in vivo cardiac electrophysiology is reported for the first time. Leveraging sub‐micrometer‐thick tissue‐conformable graphene arrays, sensing and stimulation of the open mammalian heart are demonstrated both in vitro and in vivo. Furthermore, the graphene biointerface treatment of atrioventricular block (the kind of arrhythmia where the electrical conduction from the atria to the ventricles is interrupted) is demonstrated. The graphene arrays show effective electrochemical properties, namely interface impedance down to 40 Ω cm2at 1 kHz, charge storage capacity up to 63.7 mC cm−2, and charge injection capacity up to 704 µC cm−2. Transparency of the graphene structures allows for simultaneous optical mapping of cardiac action potentials, calcium transients, and optogenetic stimulation while performing electrical measurements and stimulation. The report presents evidence of the significant potential of graphene biointerfaces for advanced cardiac electrophysiology and arrhythmia therapy.
- 17 April 2023
- Published by Wiley in Advanced Materials
- Vol. 35 (22) , e2212190
Open AccessGraphene Biointerface for Cardiac Arrhythmia Diagnosis and Treatment
Heart rhythm disorders, known as arrhythmias, cause significant morbidity and are one of the leading causes of mortality. Cardiac arrhythmias are frequently treated by implantable devices, such as pacemakers and defibrillators, or by ablation therapy guided by electroanatomical mapping. Both implantable and ablation therapies require sophisticated biointerfaces for electrophysiological measurements of electrograms and delivery of therapeutic stimulation or ablation energy. In this work, a graphene biointerface for in vivo cardiac electrophysiology is reported for the first time. Leveraging sub‐micrometer‐thick tissue‐conformable graphene arrays, sensing and stimulation of the open mammalian heart are demonstrated both in vitro and in vivo. Furthermore, the graphene biointerface treatment of atrioventricular block (the kind of arrhythmia where the electrical conduction from the atria to the ventricles is interrupted) is demonstrated. The graphene arrays show effective electrochemical properties, namely interface impedance down to 40 Ω cm2at 1 kHz, charge storage capacity up to 63.7 mC cm−2, and charge injection capacity up to 704 µC cm−2. Transparency of the graphene structures allows for simultaneous optical mapping of cardiac action potentials, calcium transients, and optogenetic stimulation while performing electrical measurements and stimulation. The report presents evidence of the significant potential of graphene biointerfaces for advanced cardiac electrophysiology and arrhythmia therapy.
- 3 June 2020
- Published by Wiley in Advanced Materials Technologies
- Vol. 5 (8)
Flexible and Transparent Metal Oxide/Metal Grid Hybrid Interfaces for Electrophysiology and Optogenetics
Flexible and transparent microelectrodes and interconnects provide the unique capability for a wide range of emerging biological applications, including simultaneous optical and electrical interrogation of biological systems. For practical biointerfacing, it is important to further improve the optical, electrical, electrochemical, and mechanical properties of the transparent conductive materials. Here, high‐performance microelectrodes and interconnects with high optical transmittance (59–81%), superior electrochemical impedance (5.4–18.4 Ω cm2), and excellent sheet resistance (5.6–14.1 Ω sq−1), using indium tin oxide (ITO) and metal grid (MG) hybrid structures are demonstrated. Notably, the hybrid structures retain the superior mechanical properties of flexible MG other than brittle ITO with no changes in sheet resistance even after 5000 bending cycles against a small radius at 5 mm. The capabilities of the ITO/MG microelectrodes and interconnects are highlighted by high‐fidelity electrical recordings of transgenic mouse hearts during co‐localized programmed optogenetic stimulation. In vivo histological analysis reveals that the ITO/MG structures are fully biocompatible. Those results demonstrate the great potential of ITO/MG interfaces for broad fundamental and translational physiological studies.
- 3 June 2020
- Published by Wiley in Advanced Materials Technologies
- Vol. 5 (8)
Flexible and Transparent Metal Oxide/Metal Grid Hybrid Interfaces for Electrophysiology and Optogenetics
Flexible and transparent microelectrodes and interconnects provide the unique capability for a wide range of emerging biological applications, including simultaneous optical and electrical interrogation of biological systems. For practical biointerfacing, it is important to further improve the optical, electrical, electrochemical, and mechanical properties of the transparent conductive materials. Here, high‐performance microelectrodes and interconnects with high optical transmittance (59–81%), superior electrochemical impedance (5.4–18.4 Ω cm2), and excellent sheet resistance (5.6–14.1 Ω sq−1), using indium tin oxide (ITO) and metal grid (MG) hybrid structures are demonstrated. Notably, the hybrid structures retain the superior mechanical properties of flexible MG other than brittle ITO with no changes in sheet resistance even after 5000 bending cycles against a small radius at 5 mm. The capabilities of the ITO/MG microelectrodes and interconnects are highlighted by high‐fidelity electrical recordings of transgenic mouse hearts during co‐localized programmed optogenetic stimulation. In vivo histological analysis reveals that the ITO/MG structures are fully biocompatible. Those results demonstrate the great potential of ITO/MG interfaces for broad fundamental and translational physiological studies.
- 27 April 2020
- Published by Wiley in Advanced Functional Materials
- Vol. 30 (24)
Multifunctional Flexible Biointerfaces for Simultaneous Colocalized Optophysiology and Electrophysiology
Recent developments in optophysiology techniques such as optogenetics have revolutionized the ability to actuate cell activity. Further combining optophysiology and electrophysiology will integrate the advantages from both optical and electrical modalities and yield enabling technologies that allow simultaneous monitoring of cellular activity in response to modulation, which are crucial for biomedical applications. However, multifunctional devices that can deliver optical stimuli to regions beneath the electrodes and perform simultaneous sensing remain largely unexplored. Existing transparent microelectrode technologies depend on external bulk optical instruments for optical interventions. Here, innovative monolithic integrated multifunctional microsystems are demonstrated by applying transparent nanogrid electrodes onto microscale light sources to permit simultaneous electrophysiology and optical modulation at the same anatomical site. The nanogrid electrodes have transmittances > 70% with a low normalized impedance of 5.9 Ω cm2. Additional features of the devices include superior mechanical flexibility, minimized light‐induced electrical artifacts, and excellent biocompatibility. Ex vivo experiments demonstrate that the multifunctional devices can record abnormal heart rhythm in transgenic mouse hearts and simultaneously restore the sinus rhythm via optogenetic pacing. This work provides a versatile approach for constructing multifunctional colocalized biointerfaces containing crosstalk‐free optical and electrical modalities with expanded opportunities in both fundamental and applied biomedical research.
- 27 April 2020
- Published by Wiley in Advanced Functional Materials
- Vol. 30 (24)
Multifunctional Flexible Biointerfaces for Simultaneous Colocalized Optophysiology and Electrophysiology
Recent developments in optophysiology techniques such as optogenetics have revolutionized the ability to actuate cell activity. Further combining optophysiology and electrophysiology will integrate the advantages from both optical and electrical modalities and yield enabling technologies that allow simultaneous monitoring of cellular activity in response to modulation, which are crucial for biomedical applications. However, multifunctional devices that can deliver optical stimuli to regions beneath the electrodes and perform simultaneous sensing remain largely unexplored. Existing transparent microelectrode technologies depend on external bulk optical instruments for optical interventions. Here, innovative monolithic integrated multifunctional microsystems are demonstrated by applying transparent nanogrid electrodes onto microscale light sources to permit simultaneous electrophysiology and optical modulation at the same anatomical site. The nanogrid electrodes have transmittances > 70% with a low normalized impedance of 5.9 Ω cm2. Additional features of the devices include superior mechanical flexibility, minimized light‐induced electrical artifacts, and excellent biocompatibility. Ex vivo experiments demonstrate that the multifunctional devices can record abnormal heart rhythm in transgenic mouse hearts and simultaneously restore the sinus rhythm via optogenetic pacing. This work provides a versatile approach for constructing multifunctional colocalized biointerfaces containing crosstalk‐free optical and electrical modalities with expanded opportunities in both fundamental and applied biomedical research.