Trevor Alexander Feagin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Trevor Alexander Feagin has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Eric Mann Heatwole
Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
5 shared publications - Gary R. Parker
Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
5 shared publications Matthew David Holmes
Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
3 shared publications- Michael Andrew Englert Erickson
Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
3 shared publications Robert M. Broilo
Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
3 shared publicationsPeter Dickson
Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
2 shared publications
Latest Publications
- 18 June 2022
- Published by Elsevier in Combustion and Flame
- Vol. 242
Mechanistic insights into the initial explosion in the deflagration-to-detonation transition
- 18 June 2022
- Published by Elsevier in Combustion and Flame
- Vol. 242
Mechanistic insights into the initial explosion in the deflagration-to-detonation transition
- 20 December 2021
- Published by Office of Scientific and Technical Information (OSTI)
IHE DDT Qualification Tests (FY2020-FY2021)
The U.S. Department of Energy's Office of Scientific and Technical Information
- 20 December 2021
- Published by Office of Scientific and Technical Information (OSTI)
IHE DDT Qualification Tests (FY2020-FY2021)
The U.S. Department of Energy's Office of Scientific and Technical Information
- Open Access
- 2 April 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-8
Time-resolved nanosecond optical pyrometry of the vapor to plasma transitions in exploding bridgewires
Electrically exploded wires find uses throughout high-energy physics. For example, they are commonly used as high-temperature sources, X-ray generators, and in precision timing detonators. However, the detailed and complete physics that occurs is complex and still poorly understood. A full mechanistic description of these complex phenomena is beyond the scope of a single paper. Instead, we focus on the formation of metal vapor and its transition to plasma. This single transition is commonly assumed to comprise “bridge-burst”. We use a suite of diagnostics including a novel, fiber-based, high-speed, optical pyrometer to better characterize this transition. The primary finding from this project is that peak light output from an exploding wire does not temporally match the peak temperature. Additionally, it is found that peak light does not align with peak bridge-burst voltage and that the peak temperature is not voltage-dependent. These findings are non-intuitive and will allow for the correction of false assumptions previously made about this topic.
- 2 April 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-8
Open AccessTime-resolved nanosecond optical pyrometry of the vapor to plasma transitions in exploding bridgewires
Electrically exploded wires find uses throughout high-energy physics. For example, they are commonly used as high-temperature sources, X-ray generators, and in precision timing detonators. However, the detailed and complete physics that occurs is complex and still poorly understood. A full mechanistic description of these complex phenomena is beyond the scope of a single paper. Instead, we focus on the formation of metal vapor and its transition to plasma. This single transition is commonly assumed to comprise “bridge-burst”. We use a suite of diagnostics including a novel, fiber-based, high-speed, optical pyrometer to better characterize this transition. The primary finding from this project is that peak light output from an exploding wire does not temporally match the peak temperature. Additionally, it is found that peak light does not align with peak bridge-burst voltage and that the peak temperature is not voltage-dependent. These findings are non-intuitive and will allow for the correction of false assumptions previously made about this topic.
- 23 November 2020
- Published by Office of Scientific and Technical Information (OSTI)
CISME report on experiments with HMX powder, PBX 9501 prills, and heated PBX 9501
The U.S. Department of Energy's Office of Scientific and Technical Information
- 23 November 2020
- Published by Office of Scientific and Technical Information (OSTI)
CISME report on experiments with HMX powder, PBX 9501 prills, and heated PBX 9501
The U.S. Department of Energy's Office of Scientific and Technical Information
- 10 November 2020
- Published by Office of Scientific and Technical Information (OSTI)
Heavily Confined PBX 9501 Experiment Report FY2020
The U.S. Department of Energy's Office of Scientific and Technical Information
- 10 November 2020
- Published by Office of Scientific and Technical Information (OSTI)
Heavily Confined PBX 9501 Experiment Report FY2020
The U.S. Department of Energy's Office of Scientific and Technical Information
- 15 July 2020
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 128 (3) , 033301
Investigating the minimum post-burst energy required to function an exploding bridgewire detonator
The minimum energy required after bridge-burst to function a commercially available RP-1 exploding bridgewire detonator with a gold bridgewire was investigated using two capacitor discharge units (CDUs) making use of state-of-the-art on/off high-voltage high-current switches. Both switches are capable of shutting off the current flow in and the conduction time was varied systematically to limit the duration of electrical energy delivered from the CDU until a detonation go/no-go threshold was reached. It was found that the minimal extra electrical energy required for a soft-fire (a statistically marginal go) was approximately half that required for a hard-fire (a definite go). The measured energy required to function the RP-1 detonator from the 11.5 kV CDU was approximately 20 mJ greater than for the 600 V CDU, and it is postulated that this was due to arcing across the detonator terminals and an associated current shunt that was not efficient at depositing energy conducive to detonator functioning. Measurements of the bridgewire temperatures bursting in air showed that the maximum temperature reached was consistent ( ) when sufficient energy was delivered that the detonator functioned (either soft- or hard-fire), but that the temperature for a sub-threshold bridgewire burst was significantly cooler at approximately 8 kK. Furthermore, it was demonstrated that the intensity of the light emitted at burst scaled with deposited energy. A related finding is that the light emission from the bridgewire peaks some tens of nanoseconds after both peak voltage and peak electrical power.- 15 July 2020
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 128 (3) , 033301
Investigating the minimum post-burst energy required to function an exploding bridgewire detonator
The minimum energy required after bridge-burst to function a commercially available RP-1 exploding bridgewire detonator with a gold bridgewire was investigated using two capacitor discharge units (CDUs) making use of state-of-the-art on/off high-voltage high-current switches. Both switches are capable of shutting off the current flow in and the conduction time was varied systematically to limit the duration of electrical energy delivered from the CDU until a detonation go/no-go threshold was reached. It was found that the minimal extra electrical energy required for a soft-fire (a statistically marginal go) was approximately half that required for a hard-fire (a definite go). The measured energy required to function the RP-1 detonator from the 11.5 kV CDU was approximately 20 mJ greater than for the 600 V CDU, and it is postulated that this was due to arcing across the detonator terminals and an associated current shunt that was not efficient at depositing energy conducive to detonator functioning. Measurements of the bridgewire temperatures bursting in air showed that the maximum temperature reached was consistent ( ) when sufficient energy was delivered that the detonator functioned (either soft- or hard-fire), but that the temperature for a sub-threshold bridgewire burst was significantly cooler at approximately 8 kK. Furthermore, it was demonstrated that the intensity of the light emitted at burst scaled with deposited energy. A related finding is that the light emission from the bridgewire peaks some tens of nanoseconds after both peak voltage and peak electrical power.- Open Access
Flow-cell based technology for massively parallel characterization of base-modified DNA aptamers
Aptamers incorporating chemically modified bases can achieve superior affinity and specificity compared to natural aptamers, but their characterization remains a labor-intensive, low-throughput task. Here we describe the ‘non-natural aptamer array’ (N2A2) system, in which a minimally modified Illumina MiSeq instrument is used for the high-throughput generation and characterization of large libraries (∼10 6 ) of base-modified DNA aptamer candidates on the basis of both target affinity and specificity. We first demonstrate the capability to screen multiple different base modifications to identify the optimal chemistry for high-affinity target binding. We next use N2A2 to generate aptamers that can maintain excellent specificity even in complex samples, with equally strong target affinity in both buffer and diluted human serum. Given that N2A2 requires only minor mechanical modifications to the MiSeq, we believe N2A2 offers a broadly accessible tool for generating high-quality affinity reagents for diverse applications.
Open AccessFlow-cell based technology for massively parallel characterization of base-modified DNA aptamers
Aptamers incorporating chemically modified bases can achieve superior affinity and specificity compared to natural aptamers, but their characterization remains a labor-intensive, low-throughput task. Here we describe the ‘non-natural aptamer array’ (N2A2) system, in which a minimally modified Illumina MiSeq instrument is used for the high-throughput generation and characterization of large libraries (∼10 6 ) of base-modified DNA aptamer candidates on the basis of both target affinity and specificity. We first demonstrate the capability to screen multiple different base modifications to identify the optimal chemistry for high-affinity target binding. We next use N2A2 to generate aptamers that can maintain excellent specificity even in complex samples, with equally strong target affinity in both buffer and diluted human serum. Given that N2A2 requires only minor mechanical modifications to the MiSeq, we believe N2A2 offers a broadly accessible tool for generating high-quality affinity reagents for diverse applications.
- 10 March 2020
- Published by Office of Scientific and Technical Information (OSTI)
The Deflagration-to-Detonation Transition in Two Dimensions
The U.S. Department of Energy's Office of Scientific and Technical Information
- 10 March 2020
- Published by Office of Scientific and Technical Information (OSTI)
The Deflagration-to-Detonation Transition in Two Dimensions
The U.S. Department of Energy's Office of Scientific and Technical Information