Steve Blair
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Steve Blair has a total of 163 co-authors. Here are the top co-authors by number of shared publications:
- Xiaojin Jiao
University of Utah
6 shared publications Jeremy Goeckeritz
Department of Electrical and Computer Engineering, University of Utah, 50 S Central Campus Dr, Salt Lake City, Utah 84112, USA
5 shared publications- Yunshan Wang
The University of Utah
5 shared publications - Alessandra Angelucci
Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy
4 shared publications Andrew M. Clark
Department of Ophthalmology and Visual Science Moran Eye Institute University of Utah Salt Lake City UT 84132 USA
4 shared publicationsYan Chen
University of Utah, Department of Electrical and Computer Engineering, Salt Lake, Utah 84112-0000, USA
4 shared publications
Latest Publications
- 8 June 2026
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 18 (23) , 32434-32445
A Customizable 3D-Printed Neural Probe Array Using Two-Photon Polymerization with Millimeter-Scaled Conductive Polymer as an Electrode Material
Microelectrode arrays are an essential tool for interfacing with nerve tissue to better understand brain functioning, as well as for therapeutic applications. Yet, the structural customizability of microelectrode arrays and the integration of specific materials into electrode designs remain challenging. Two-photon polymerization (2PP) is a high-resolution additive fabrication technique capable of producing micro- and nanoscale architectures, thus offering design flexibility for microelectrode arrays. However, due to the limited electrical conductivity of photo-cross-linkable polymers, 2PP three-dimensional (3D) printing is not widely adopted for the fabrication of microelectrode arrays yet. In this work, we present the millimeter-scaled integration of the conductive polymer poly(3,4-ethylenedioxythiophene):tetrafluoroborate (PEDOT:BF4) into 2PP 3D-printed neural probe architectures via electrochemical deposition. Unlike state-of-the-art thin-film PEDOT coatings, this approach enables the formation of vertically extended, entirely polymer-based electrodes with a length in the millimeter range. These all-polymer electrode arrays exhibit low impedance, excellent electrochemical and mechanical stability, and enable neural recordings in freely moving rats. This fabrication process may thus provide a platform technology for customizable microelectrode arrays, demonstrating the effective integration of a conductive polymer into 2PP 3D-printed microneedle arrays. This platform could be leveraged for a wide range of applications in the broader field of bioelectronics.
- 8 June 2026
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 18 (23) , 32434-32445
A Customizable 3D-Printed Neural Probe Array Using Two-Photon Polymerization with Millimeter-Scaled Conductive Polymer as an Electrode Material
Microelectrode arrays are an essential tool for interfacing with nerve tissue to better understand brain functioning, as well as for therapeutic applications. Yet, the structural customizability of microelectrode arrays and the integration of specific materials into electrode designs remain challenging. Two-photon polymerization (2PP) is a high-resolution additive fabrication technique capable of producing micro- and nanoscale architectures, thus offering design flexibility for microelectrode arrays. However, due to the limited electrical conductivity of photo-cross-linkable polymers, 2PP three-dimensional (3D) printing is not widely adopted for the fabrication of microelectrode arrays yet. In this work, we present the millimeter-scaled integration of the conductive polymer poly(3,4-ethylenedioxythiophene):tetrafluoroborate (PEDOT:BF4) into 2PP 3D-printed neural probe architectures via electrochemical deposition. Unlike state-of-the-art thin-film PEDOT coatings, this approach enables the formation of vertically extended, entirely polymer-based electrodes with a length in the millimeter range. These all-polymer electrode arrays exhibit low impedance, excellent electrochemical and mechanical stability, and enable neural recordings in freely moving rats. This fabrication process may thus provide a platform technology for customizable microelectrode arrays, demonstrating the effective integration of a conductive polymer into 2PP 3D-printed microneedle arrays. This platform could be leveraged for a wide range of applications in the broader field of bioelectronics.
- Open Access
- 17 February 2026
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 139 (7)
Control of extraordinary optical transmission in resonant terahertz gratings via lateral depletion in an AlGaN/GaN heterostructure
Periodic metallic gratings on substrates can support a range of electromagnetic modes, such as leaky waveguide, guided-resonant, and Fabry–Pérot cavity modes, which can strongly modulate optical transmission under resonant excitation. Here, we investigate how this coupling can be dynamically manipulated through charge-density control in a laterally patterned AlGaN/GaN heterostructure. The structure comprises metallic stripes separated by regions containing a two-dimensional electron gas (2DEG), forming a periodically modulated interface whose electromagnetic response is governed by the charge density between the stripes. In the unbiased state, the conductive 2DEG screens the incident terahertz field and suppresses excitation of guided modes. When the 2DEG is depleted, the change in boundary conditions allows efficient coupling into substrate resonances, producing a strong modulation at particular frequencies where extraordinary optical transmission (EOT) through the structure takes place. The results highlight the sensitive dependence of guided-mode-resonance mediated EOT on inter-stripe charge distribution and demonstrate a direct interplay between carrier dynamics and resonant electromagnetic phenomena in the terahertz regime.
- 17 February 2026
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 139 (7)
Open AccessControl of extraordinary optical transmission in resonant terahertz gratings via lateral depletion in an AlGaN/GaN heterostructure
Periodic metallic gratings on substrates can support a range of electromagnetic modes, such as leaky waveguide, guided-resonant, and Fabry–Pérot cavity modes, which can strongly modulate optical transmission under resonant excitation. Here, we investigate how this coupling can be dynamically manipulated through charge-density control in a laterally patterned AlGaN/GaN heterostructure. The structure comprises metallic stripes separated by regions containing a two-dimensional electron gas (2DEG), forming a periodically modulated interface whose electromagnetic response is governed by the charge density between the stripes. In the unbiased state, the conductive 2DEG screens the incident terahertz field and suppresses excitation of guided modes. When the 2DEG is depleted, the change in boundary conditions allows efficient coupling into substrate resonances, producing a strong modulation at particular frequencies where extraordinary optical transmission (EOT) through the structure takes place. The results highlight the sensitive dependence of guided-mode-resonance mediated EOT on inter-stripe charge distribution and demonstrate a direct interplay between carrier dynamics and resonant electromagnetic phenomena in the terahertz regime.
- Open Access
- 15 September 2025
- Published by Wiley in Advanced Healthcare Materials
- Vol. 15 (3) , e00575
Cortical Response to Acute Implantation of the Utah Optrode Array in Macaque Cortex
Optogenetics has transformed neural circuit studies, but its application to large‐brained species like non‐human primates (NHPs) remains limited. A major challenge in NHP optogenetics is delivering light to large volumes of deep neural tissue with high spatiotemporal precision, without affecting superficial tissue. To overcome these limitations, we recently developed and tested in vivo in NHP cortex, the Utah Optrode Array (UOA). This is a 10 × 10 array of penetrating glass shanks, tiling a 4 × 4 mm 2 area, bonded to interleaved needle‐aligned and interstitial µLED arrays, enabling independent photostimulation of deep and superficial tissue. Here, the acute biological response to UOA implantation in NHP cortex is investigated, to optimize device design for reduced insertion trauma and chronic response. To this goal, UOA shank diameter, geometry, and insertion pressure are varied, and their effects on astrocytes, microglia, and neuronal viability are assessed, following acute implantation. It is found that UOAs with smaller shank diameter, smooth surface texture, and round tips cause the least damage. Higher insertion pressures have limited effects on inflammation, but cause greater tissue compression. The results highlight the importance of balancing shank diameter, geometry, and insertion pressure in UOA design for preserving tissue integrity and improving long‐term UOA performance and biocompatibility.
- 15 September 2025
- Published by Wiley in Advanced Healthcare Materials
- Vol. 15 (3) , e00575
Open AccessCortical Response to Acute Implantation of the Utah Optrode Array in Macaque Cortex
Optogenetics has transformed neural circuit studies, but its application to large‐brained species like non‐human primates (NHPs) remains limited. A major challenge in NHP optogenetics is delivering light to large volumes of deep neural tissue with high spatiotemporal precision, without affecting superficial tissue. To overcome these limitations, we recently developed and tested in vivo in NHP cortex, the Utah Optrode Array (UOA). This is a 10 × 10 array of penetrating glass shanks, tiling a 4 × 4 mm 2 area, bonded to interleaved needle‐aligned and interstitial µLED arrays, enabling independent photostimulation of deep and superficial tissue. Here, the acute biological response to UOA implantation in NHP cortex is investigated, to optimize device design for reduced insertion trauma and chronic response. To this goal, UOA shank diameter, geometry, and insertion pressure are varied, and their effects on astrocytes, microglia, and neuronal viability are assessed, following acute implantation. It is found that UOAs with smaller shank diameter, smooth surface texture, and round tips cause the least damage. Higher insertion pressures have limited effects on inflammation, but cause greater tissue compression. The results highlight the importance of balancing shank diameter, geometry, and insertion pressure in UOA design for preserving tissue integrity and improving long‐term UOA performance and biocompatibility.
- Open Access
- 6 March 2025
- Published by Wiley in Advanced Photonics Research
- Vol. 6 (6)
Low‐Loss Parowax‐Imprinted Diffractive Neural Network for Orbital Angular Momentum Terahertz Holographic Imaging
The helical phase front of orbital angular momentum (OAM) waves offer additional multiplexing degree‐of‐freedom to increase the capacity of communication systems in the terahertz domain, which in turn can significantly benefit forthcoming high‐speed wireless sixth‐generation communication networks. This work introduces a diffractive neural network approach for recognizing the topological charge of OAM waves and their superposition. Moreover, it is shown that the diffractive network can further enable mathematical operations through the topological charges (TCs) of the superposed OAM waves. The diffractive neural networks (DNN) are fabricated through an imprinting technique with low‐loss parowax material. To validate the feasibility of this general approach, experimental demonstrations are conducted, which show that the low‐loss parowax DNN effectively detects the TCs of the OAM waves and display them in a numerical format.
- 6 March 2025
- Published by Wiley in Advanced Photonics Research
- Vol. 6 (6)
Open AccessLow‐Loss Parowax‐Imprinted Diffractive Neural Network for Orbital Angular Momentum Terahertz Holographic Imaging
The helical phase front of orbital angular momentum (OAM) waves offer additional multiplexing degree‐of‐freedom to increase the capacity of communication systems in the terahertz domain, which in turn can significantly benefit forthcoming high‐speed wireless sixth‐generation communication networks. This work introduces a diffractive neural network approach for recognizing the topological charge of OAM waves and their superposition. Moreover, it is shown that the diffractive network can further enable mathematical operations through the topological charges (TCs) of the superposed OAM waves. The diffractive neural networks (DNN) are fabricated through an imprinting technique with low‐loss parowax material. To validate the feasibility of this general approach, experimental demonstrations are conducted, which show that the low‐loss parowax DNN effectively detects the TCs of the OAM waves and display them in a numerical format.
- Open Access
Cortical Response to Acute Implantation of the Utah Optrode Array in Macaque Cortex
Optogenetics has transformed the study of neural circuit function, but limitations in its application to species with large brains, such as non-human primates (NHPs), remain. A major challenge in NHP optogenetics is delivering light to sufficiently large volumes of deep neural tissue with high spatiotemporal precision, without simultaneously affecting superficial tissue. To overcome these limitations, we recently developed and tested in vivo in NHP cortex, the Utah Optrode Array (UOA). This is a 10×10 array of penetrating glass shanks, tiling a 4×4mm 2 area, bonded to interleaved needle-aligned and interstitial µLED arrays, which allows for independent photostimulation of deep and superficial brain tissue. Here, we investigate the acute biological response to UOA implantation in NHP cortex, with the goal of optimizing device design for reduced insertion trauma and subsequent chronic response. To this goal, we systematically vary UOA shank diameter, surface texture, tip geometry, and insertion pressure, and assess their effects on astrocytes, microglia, and neuronal viability, following acute implantation. We find that UOAs with shanks of smaller diameter, smooth surface texture and round tips cause the least damage. Higher insertion pressures have limited effects on the inflammatory response, but lead to greater tissue compression. Our results highlight the importance of balancing shank diameter, tip geometry, and insertion pressure in UOA design for preserving tissue integrity and improving long-term UOA performance and biocompatibility.
Open AccessCortical Response to Acute Implantation of the Utah Optrode Array in Macaque Cortex
Optogenetics has transformed the study of neural circuit function, but limitations in its application to species with large brains, such as non-human primates (NHPs), remain. A major challenge in NHP optogenetics is delivering light to sufficiently large volumes of deep neural tissue with high spatiotemporal precision, without simultaneously affecting superficial tissue. To overcome these limitations, we recently developed and tested in vivo in NHP cortex, the Utah Optrode Array (UOA). This is a 10×10 array of penetrating glass shanks, tiling a 4×4mm 2 area, bonded to interleaved needle-aligned and interstitial µLED arrays, which allows for independent photostimulation of deep and superficial brain tissue. Here, we investigate the acute biological response to UOA implantation in NHP cortex, with the goal of optimizing device design for reduced insertion trauma and subsequent chronic response. To this goal, we systematically vary UOA shank diameter, surface texture, tip geometry, and insertion pressure, and assess their effects on astrocytes, microglia, and neuronal viability, following acute implantation. We find that UOAs with shanks of smaller diameter, smooth surface texture and round tips cause the least damage. Higher insertion pressures have limited effects on the inflammatory response, but lead to greater tissue compression. Our results highlight the importance of balancing shank diameter, tip geometry, and insertion pressure in UOA design for preserving tissue integrity and improving long-term UOA performance and biocompatibility.
- 26 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (11) , 17653-17660
Wavelength-Dependent Angular Sensitivity Signatures in SPR Sensors: Is the 633 nm Wavelength Still Optimal for the Latest Designs?
Research focused on improving the sensitivity of SPR analytical technology has led to the investigation of different electric field enhancement elements for incorporation with classic sensor structures. Over the past ten years, considerable attention has been given to ceramic, metal oxide, and 2D materials that not only improve the magnitude of the field but are also used as affinity layers for improved adsorption of molecules. However, focusing on the improvements these materials deliver can lead designers to explore only some of themultiple dependencies associated with sensitivity. When using the angular interrogation mode, the impacts of working with different wavelengths are generally disregarded, as a fixed value of λ=633 nm is commonly adopted. Choosing 633 nm is often justified for achieving near-zero reflectivity and good sensitivity. However, newer SPR designs lack the determination of optimal wavelength-dependent sensitivity points. This article numerically investigates sensitivity as a function of wavelength for SPR sensors. We systematically study the effects of operating outside λ=633 nm and show that the signature produced by bare metal sensors does not always resemble the signatures produced by field-enhanced designs. Examinations are based on Graphene and BaTiO 3 . Furthermore, we demonstrate how imposing thresholds on optimization targets can be leveraged to sustain high-sensitivity results, and we elaborate on the pertinent tradeoffs. Our approach shows further performance improvements in designs for which highly efficient benchmarks have already been demonstrated.
- 26 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (11) , 17653-17660
Wavelength-Dependent Angular Sensitivity Signatures in SPR Sensors: Is the 633 nm Wavelength Still Optimal for the Latest Designs?
Research focused on improving the sensitivity of SPR analytical technology has led to the investigation of different electric field enhancement elements for incorporation with classic sensor structures. Over the past ten years, considerable attention has been given to ceramic, metal oxide, and 2D materials that not only improve the magnitude of the field but are also used as affinity layers for improved adsorption of molecules. However, focusing on the improvements these materials deliver can lead designers to explore only some of themultiple dependencies associated with sensitivity. When using the angular interrogation mode, the impacts of working with different wavelengths are generally disregarded, as a fixed value of λ=633 nm is commonly adopted. Choosing 633 nm is often justified for achieving near-zero reflectivity and good sensitivity. However, newer SPR designs lack the determination of optimal wavelength-dependent sensitivity points. This article numerically investigates sensitivity as a function of wavelength for SPR sensors. We systematically study the effects of operating outside λ=633 nm and show that the signature produced by bare metal sensors does not always resemble the signatures produced by field-enhanced designs. Examinations are based on Graphene and BaTiO 3 . Furthermore, we demonstrate how imposing thresholds on optimization targets can be leveraged to sustain high-sensitivity results, and we elaborate on the pertinent tradeoffs. Our approach shows further performance improvements in designs for which highly efficient benchmarks have already been demonstrated.
- Open Access
- 14 March 2024
- Published by Springer Nature in Communications Biology
- Vol. 7 (1) , 1-18
An optrode array for spatiotemporally-precise large-scale optogenetic stimulation of deep cortical layers in non-human primates
Optogenetics has transformed studies of neural circuit function, but remains challenging to apply to non-human primates (NHPs). A major challenge is delivering intense, spatiotemporally-precise, patterned photostimulation across large volumes in deep tissue. Such stimulation is critical, for example, to modulate selectively deep-layer corticocortical feedback circuits. To address this need, we have developed the Utah Optrode Array (UOA), a 10×10 glass needle waveguide array fabricated atop a novel opaque optical interposer, and bonded to an electrically addressable µLED array. In vivo experiments with the UOA demonstrated large-scale, spatiotemporally precise, activation of deep circuits in NHP cortex. Specifically, the UOA permitted both focal (confined to single layers/columns), and widespread (multiple layers/columns) optogenetic activation of deep layer neurons, as assessed with multi-channel laminar electrode arrays, simply by varying the number of activated µLEDs and/or the irradiance. Thus, the UOA represents a powerful optoelectronic device for targeted manipulation of deep-layer circuits in NHP models.
- 14 March 2024
- Published by Springer Nature in Communications Biology
- Vol. 7 (1) , 1-18
Open AccessAn optrode array for spatiotemporally-precise large-scale optogenetic stimulation of deep cortical layers in non-human primates
Optogenetics has transformed studies of neural circuit function, but remains challenging to apply to non-human primates (NHPs). A major challenge is delivering intense, spatiotemporally-precise, patterned photostimulation across large volumes in deep tissue. Such stimulation is critical, for example, to modulate selectively deep-layer corticocortical feedback circuits. To address this need, we have developed the Utah Optrode Array (UOA), a 10×10 glass needle waveguide array fabricated atop a novel opaque optical interposer, and bonded to an electrically addressable µLED array. In vivo experiments with the UOA demonstrated large-scale, spatiotemporally precise, activation of deep circuits in NHP cortex. Specifically, the UOA permitted both focal (confined to single layers/columns), and widespread (multiple layers/columns) optogenetic activation of deep layer neurons, as assessed with multi-channel laminar electrode arrays, simply by varying the number of activated µLEDs and/or the irradiance. Thus, the UOA represents a powerful optoelectronic device for targeted manipulation of deep-layer circuits in NHP models.
- 15 December 2023
- Published by Elsevier in Optical Materials
- Vol. 147
Fluorophore interactions with the surface modes and internal modes of a photonic crystal
- 15 December 2023
- Published by Elsevier in Optical Materials
- Vol. 147
Fluorophore interactions with the surface modes and internal modes of a photonic crystal
- 15 February 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (5) , 7505-7514
Overcoming the field-of-view to diameter trade-off in microendoscopy via computational optrode-array microscopy
High-resolution microscopy of deep tissue with large field-of-view (FOV) is critical for elucidating organization of cellular structures in plant biology. Microscopy with an implanted probe offers an effective solution. However, there exists a fundamental trade-off between the FOV and probe diameter arising from aberrations inherent in conventional imaging optics (typically, FOV < 30% of diameter). Here, we demonstrate the use of microfabricated non-imaging probes (optrodes) that when combined with a trained machine-learning algorithm is able to achieve FOV of 1x to 5x the probe diameter. Further increase in FOV is achieved by using multiple optrodes in parallel. With a 1 × 2 optrode array, we demonstrate imaging of fluorescent beads (including 30 FPS video), stained plant stem sections and stained living stems. Our demonstration lays the foundation for fast, high-resolution microscopy with large FOV in deep tissue via microfabricated non-imaging probes and advanced machine learning.
- 15 February 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (5) , 7505-7514
Overcoming the field-of-view to diameter trade-off in microendoscopy via computational optrode-array microscopy
High-resolution microscopy of deep tissue with large field-of-view (FOV) is critical for elucidating organization of cellular structures in plant biology. Microscopy with an implanted probe offers an effective solution. However, there exists a fundamental trade-off between the FOV and probe diameter arising from aberrations inherent in conventional imaging optics (typically, FOV < 30% of diameter). Here, we demonstrate the use of microfabricated non-imaging probes (optrodes) that when combined with a trained machine-learning algorithm is able to achieve FOV of 1x to 5x the probe diameter. Further increase in FOV is achieved by using multiple optrodes in parallel. With a 1 × 2 optrode array, we demonstrate imaging of fluorescent beads (including 30 FPS video), stained plant stem sections and stained living stems. Our demonstration lays the foundation for fast, high-resolution microscopy with large FOV in deep tissue via microfabricated non-imaging probes and advanced machine learning.
- Open Access
An Optrode Array for Spatiotemporally Precise Large-Scale Optogenetic Stimulation of Deep Cortical Layers in Non-human Primates
Optogenetics has transformed studies of neural circuit function, but remains challenging to apply in large brains, such as those of non-human primates (NHPs). A major challenge is delivering intense, spatiotemporally precise, patterned photostimulation across large volumes in deep tissue. Such stimulation is critical, for example, to modulate selectively deep-layer corticocortical feedback projections. To address this unmet need, we have developed the Utah Optrode Array (UOA), a 10×10 glass needle waveguide array fabricated atop a novel opaque optical interposer then bonded to an electrically addressable μLED array. In vivo experiments with the UOA demonstrated large-scale, spatiotemporally precise, activation of deep circuits in monkey cortex. Specifically, the UOA permitted both focal (confined to single layers/columns), and widespread (multiple layers/columns) optogenetic activation of deep layer neurons, simply by varying the number of activated μLEDs and/or the irradiance. Thus, the UOA represents a powerful optoelectronic device for targeted manipulation of deep-layer circuits in NHP models.
Open AccessAn Optrode Array for Spatiotemporally Precise Large-Scale Optogenetic Stimulation of Deep Cortical Layers in Non-human Primates
Optogenetics has transformed studies of neural circuit function, but remains challenging to apply in large brains, such as those of non-human primates (NHPs). A major challenge is delivering intense, spatiotemporally precise, patterned photostimulation across large volumes in deep tissue. Such stimulation is critical, for example, to modulate selectively deep-layer corticocortical feedback projections. To address this unmet need, we have developed the Utah Optrode Array (UOA), a 10×10 glass needle waveguide array fabricated atop a novel opaque optical interposer then bonded to an electrically addressable μLED array. In vivo experiments with the UOA demonstrated large-scale, spatiotemporally precise, activation of deep circuits in monkey cortex. Specifically, the UOA permitted both focal (confined to single layers/columns), and widespread (multiple layers/columns) optogenetic activation of deep layer neurons, simply by varying the number of activated μLEDs and/or the irradiance. Thus, the UOA represents a powerful optoelectronic device for targeted manipulation of deep-layer circuits in NHP models.