Sung Phil Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sung Phil Yang has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Eun Joo Kim
Department of Rehabilitation Medicine Rehabilitation Hospital, National Rehabilitation Center Seoul South Korea
2 shared publications - Bum-Suk Lee
Department of Rehabilitation Medicine, National Rehabilitation Center, Seoul, South Korea
1 shared publication - Hae Young Kim
Department of Rehabilitation Medicine, National Rehabilitation Center, Seoul, Korea
1 shared publication - Han Ram Pak
Department of Clinical Research on Rehabilitation, National Rehabilitation Research Institute, Seoul, Korea
1 shared publication - Hye Jin Lee
Department of Rehabilitation Exercise, National Rehabilitation Center & Hospital, Seoul, Korea
1 shared publication - Hyun Ki Kim
Researcher Health Insurance Research Institute (HIRI) National Health Insurance Service Wonju Korea
1 shared publication
Latest Publications
- 30 March 2026
- Published by Wiley in Physiotherapy Research International
- Vol. 31 (2) , e70206
The Effect of Various Walkway Lengths on Comfortable and Maximum Gait Speed in Patients With Subacute Stroke
Background and Purpose: Gait speed is a key indicator of functional recovery and activity performance in patients with subacute stroke. However, walkway length for gait speed assessment has not been standardized, and findings regarding its influence remain inconsistent. This study investigated the test–retest reliabilities of comfortable gait speed (CGS) and fast gait speed (FGS) across 5‐, 8‐, and 10‐m walkways in patients with subacute stroke and examined the effects of walkway length on both measures. Methods: This retrospective cross‐sectional study included 21 patients with subacute stroke. Participants completed six experimental conditions in a randomized order to assess test–retest reliabilities and performance times for CGS and FGS on 5‐, 8‐, and 10‐m walkways. Results: The reliability of CGS for the 5‐, 8‐, and 10‐m walk tests was excellent, with intraclass correlation coefficients (ICCs) of 0.986–0.995. FGS also showed excellent reliability for the 5‐, 8‐, and 10‐m walk tests, with ICCs of 0.985–0.994. There were no significant differences in CGS across the 5‐, 8‐, and 10‐m tests. However, significant differences were observed in FGS for the 10‐m walk test compared with the 5‐m and 8‐m walk tests. Additionally, there were significant differences between CGS and FGS for each of the 5‐, 8‐, and 10‐m walk tests. Discussion: Within this study population of patients with subacute stroke who could walk independently without gait assistive devices, walkway length may influence the assessment of FGS in clinical settings. A 5‐m walkway may still provide a reliable option for measuring CGS in space‐limited environments, whereas a longer walkway may be more appropriate for assessing FGS.
- 30 March 2026
- Published by Wiley in Physiotherapy Research International
- Vol. 31 (2) , e70206
The Effect of Various Walkway Lengths on Comfortable and Maximum Gait Speed in Patients With Subacute Stroke
Background and Purpose: Gait speed is a key indicator of functional recovery and activity performance in patients with subacute stroke. However, walkway length for gait speed assessment has not been standardized, and findings regarding its influence remain inconsistent. This study investigated the test–retest reliabilities of comfortable gait speed (CGS) and fast gait speed (FGS) across 5‐, 8‐, and 10‐m walkways in patients with subacute stroke and examined the effects of walkway length on both measures. Methods: This retrospective cross‐sectional study included 21 patients with subacute stroke. Participants completed six experimental conditions in a randomized order to assess test–retest reliabilities and performance times for CGS and FGS on 5‐, 8‐, and 10‐m walkways. Results: The reliability of CGS for the 5‐, 8‐, and 10‐m walk tests was excellent, with intraclass correlation coefficients (ICCs) of 0.986–0.995. FGS also showed excellent reliability for the 5‐, 8‐, and 10‐m walk tests, with ICCs of 0.985–0.994. There were no significant differences in CGS across the 5‐, 8‐, and 10‐m tests. However, significant differences were observed in FGS for the 10‐m walk test compared with the 5‐m and 8‐m walk tests. Additionally, there were significant differences between CGS and FGS for each of the 5‐, 8‐, and 10‐m walk tests. Discussion: Within this study population of patients with subacute stroke who could walk independently without gait assistive devices, walkway length may influence the assessment of FGS in clinical settings. A 5‐m walkway may still provide a reliable option for measuring CGS in space‐limited environments, whereas a longer walkway may be more appropriate for assessing FGS.
- Open Access
- 30 April 2020
- Published by Korean Academy of Rehabilitation Medicine in Annals of Rehabilitation Medicine
- Vol. 44 (2) , 131-141
Energy Efficiency and Patient Satisfaction of Gait With Knee-Ankle-Foot Orthosis and Robot (ReWalk)-Assisted Gait in Patients With Spinal Cord Injury
Objective To compare the energy efficiency of gait with knee-ankle-foot orthosis (KAFO) and robot-assisted gait and to develop a usability questionnaire to evaluate the satisfaction of walking devices in paraplegic patients with spinal cord injuries.Methods Thirteen patients with complete paraplegia participated and 10 completed the evaluation. They were trained to walk with KAFO (KAFO-gait) or a ReWalk robot (ReWalk-gait) for 4 weeks (20 sessions). After a 2-week wash-out period, they switched walking devices and underwent 4 additional weeks of training. Two evaluations were performed (after 2 and 4 weeks) following the training periods for each walking device, using the 6-minute walking test (6MWT) and 30-minute walking test (30MWT). The spatiotemporal variables (walking distance, velocity, and cadence) and energy expenditure (heart rate, maximal heart rate, the physiologic cost index, oxygen consumption, metabolic equivalents, and energy efficiency) were evaluated duringthe 6MWT and 30MWT. A usability evaluation questionnaire for walking devices was developed based on the International Organization for Standardization/International Electrotechnical Commission guidelines through expert consultation.Results The ReWalk-gait presented significant advantages in energy efficiency compared to KAFO-gait in the 6MWT and 30MWT; however, there were no differences in walking distance or speed in the 30MWT between ReWalk-gait and KAFOgait. The usability test demonstrated that ReWalk-gait was not superior to KAFO-gait in terms of safety, efficacy, efficiency, or patient satisfaction.Conclusion The robot (ReWalk) enabled patients with paraplegia to walk with lower energy consumption compared to KAFO, but the ReWalk-gait was not superior to KAFO-gaitin terms of patient satisfaction.
- 30 April 2020
- Published by Korean Academy of Rehabilitation Medicine in Annals of Rehabilitation Medicine
- Vol. 44 (2) , 131-141
Open AccessEnergy Efficiency and Patient Satisfaction of Gait With Knee-Ankle-Foot Orthosis and Robot (ReWalk)-Assisted Gait in Patients With Spinal Cord Injury
Objective To compare the energy efficiency of gait with knee-ankle-foot orthosis (KAFO) and robot-assisted gait and to develop a usability questionnaire to evaluate the satisfaction of walking devices in paraplegic patients with spinal cord injuries.Methods Thirteen patients with complete paraplegia participated and 10 completed the evaluation. They were trained to walk with KAFO (KAFO-gait) or a ReWalk robot (ReWalk-gait) for 4 weeks (20 sessions). After a 2-week wash-out period, they switched walking devices and underwent 4 additional weeks of training. Two evaluations were performed (after 2 and 4 weeks) following the training periods for each walking device, using the 6-minute walking test (6MWT) and 30-minute walking test (30MWT). The spatiotemporal variables (walking distance, velocity, and cadence) and energy expenditure (heart rate, maximal heart rate, the physiologic cost index, oxygen consumption, metabolic equivalents, and energy efficiency) were evaluated duringthe 6MWT and 30MWT. A usability evaluation questionnaire for walking devices was developed based on the International Organization for Standardization/International Electrotechnical Commission guidelines through expert consultation.Results The ReWalk-gait presented significant advantages in energy efficiency compared to KAFO-gait in the 6MWT and 30MWT; however, there were no differences in walking distance or speed in the 30MWT between ReWalk-gait and KAFOgait. The usability test demonstrated that ReWalk-gait was not superior to KAFO-gait in terms of safety, efficacy, efficiency, or patient satisfaction.Conclusion The robot (ReWalk) enabled patients with paraplegia to walk with lower energy consumption compared to KAFO, but the ReWalk-gait was not superior to KAFO-gaitin terms of patient satisfaction.