DADavid N. Agyeman-Budu

David N. Agyeman-Budu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


David N. Agyeman-Budu has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Direct visualization of aqueous zinc metal plating and stripping via transmission X-ray microscopy

    by David N. Agyeman-Budu, Yechuan L. Chen, Molleigh B. Preefer, Johanna Nelson Weker

    A geometry-defined model platform visualizes how 3D-inspired anode architecture governs Zn plating, stripping, and corrosion evolution operando.

  • In Situ X-Ray Imaging of Aqueous Zinc-Ion Battery Anodes

    by Chi L Cao, Anamika Poduval, David N Agyeman-Budu, Marwa Atwa, Johanna Nelson Weker

    Aqueous zinc-ion batteries (AZIBs) have emerged as a promising option for long duration energy storage because of their comparable energy and power density yet relatively lower cost, improved safety, and decreased resource constraints compared to lithium-ion batteries. One of the challenges hindering the adoption of AZIBs is the irreversibility of the plating/stripping reaction at the zinc metal anode, a result of issues such as dendrite growth and hydrogen evolution from corrosion. [1–3] We use in-situ synchrotron X-ray imaging to study the changes in morphology during the plating of zinc during cycling as well as the evolution of hydrogen gas because of corrosion. Custom homemade Zn/Zn symmetric cells were cycled at various current densities in 1 M ZnSO 4 electrolyte and investigated at the Stanford Synchrotron Radiation Lightsource (SSRL) using 2D radiography, which provided information across a large cross-sectional area of the electrode, and transmission X-ray microscopy (TXM), which provided information with a micron-scale field of view. The effects of mass transport and bubble nucleation sites on the electrochemistry and uniformity of deposited zinc was observed. Additionally, externally applied magnetic fields have been shown in systems such as electrodeposition and electrocatalysis to mitigate the effects of corrosion. [4–6] Using permanent magnets, we apply a uniform magnetic field in both perpendicular and parallel orientations to Zn/Zn symmetric cells to study the effects on ion transport and dendrite formation using 2D radiography and TXM. References [1] T. H. Wu, Y. Zhang, Z. D. Althouse, and N. Liu, Mater Today Nano , 6 (2019). [2] C. Han, W. Li, H. K. Liu, S. Dou, and J. Wang, Nano Energy , 74 (2020). [3] X. Ji, Energy Environ Sci , 12 , 3203–3224 (2019). [4] L. M. A. Monzon and J. M. D. Coey, Electrochem commun , 42 , 38–41 (2014). [5] J. A. Koza, M. Uhlemann, A. Gebert, and L. Schultz, Electrochem commun , 10 , 1330–1333 (2008). [6] K. Wang et al., ACS Appl Energy Mater , 3 , 6752–6757 (2020).

  • Open Access

    The Effect of Metal d Band Position on AnionRedox in Alkali-Rich Sulfides

    by Seong Shik Kim, David N. Agyeman-Budu, Joshua J. Zak, Jessica L. Andrews, Jonathan Li, Brent C. Melot, Johanna Nelson Weker, Kimberly A. See

    New energy storage methods are emerging to increase the energy density of the state-of-the-art battery systems beyond the conventional intercalation electrode materials. For instance, employing anion redox can yield higher capacities compared to transition metal redox alone. Anion redox in sulfides has been recognized since the early days of rechargeable battery research. however, now we aim to understand the charge compensation mechanisms and how to control them. Here, we study the effect of d-p overlap in controlling anion redox by shifting the metal d band position relative to the S p band. We aim to determine the effect of shifting the d band position on the electronic structure and ultimately on charge compensation. Two isostructural sulfides LiNaFeS2 and LiNaCoS2 are directly compared with the hypothesis that the Co material should yield more covalent metal-anion bonds. The newly reported material LiNaCoS2 exhibits multielectron capacity of >/=1.7 electrons per formula unit, but despite the lowered Co d band, the voltage of anion redox is close to that of LiNaFeS2. Interestingly, the material suffers from rapid capacity fade. Through a combination of solid-state nuclear magnetic resonance spectroscopy, Co and S X-ray absorption spectroscopy, X-ray diffraction, and partial density of states calculations, we demonstrate that S oxidation to [S2]2- occurs in early states of charge which leads to an irreversible phase transition into pyrite CoS2 and lithiated cobalt spinel phases such as LixCo3S4 and LixCo9S8. Thus, we conclude that anion oxidation occurs from S nonbonding p orbitals and the Co d bands are too low in energy to prevent a phase transition to more thermodynamically stable persulfide-containing phases. Further, the higher crystal field stabilization energy for octahedral coordination over tetrahedral coordination leads to phase transition in LiNaCoS2.

  • Design and Characterization of a Neutron-Friendly Lithium-Ion Battery Coin Cell for Extreme Fast-Charging

    by Maha Yusuf, Jacob Michael LaManna, Molleigh Preefer, Partha P Paul, David N Agyeman-Budu, Michael F Toney, Johanna Nelson Weker


  • Efficient high-pass filtering with practical, high-yield X-ray transmission mirror optics

    by David N. Agyeman-Budu, Joel D. Brock, Arthur R. Woll

    Although the concept, first demonstration, and potential applications of X-ray transmission mirrors (XTMs) were initially described over 30 years ago, only a few implementations exist in the literature. This is attributed to the unsolved challenge of a thick frame supporting a thin, reflecting membrane which does not itself block the transmitted beam. Here, we introduce a novel approach to solve this problem by employing silicon microfabrication. A robust XTM frame has been fabricated by using a novel two-step etch process, which secures the thin-film membrane without blocking the transmitted beam. Specifically, we have fabricated delicate XTM optics with 90% yield, which consist of 280-nm-thick low-stress silicon nitride membrane windows that are 1.5 mm wide and 125 mm long on silicon substrates. The XTM optics have been demonstrated to be a more efficient high-pass X-ray filter; for example, when configured for 40% transmission of 11.3 keV photons, we measure the reduction of 8.4 keV photons by a factor of 56.


  • Open Access

    Germanium Collimating micro-Channel Arrays For High Resolution, High Energy Confocal X-ray Fluorescence Microscopy

    by David N Agyeman-Budu, Sanjukta Choudhury, Ian Coulthard, Robert Gordon, Emil Hallin, Arthur R Woll

    Confocal x-ray fluorescence microscopy (CXRF) allows direct detection of x-ray fluorescence from a micron-scale 3D volume of an extended, unthinned sample. We have previously demonstrated the use of a novel collection optic, fabricated from silicon, that improves the spatial resolution of this approach by an order of magnitude over CXRF using polycapillaries. The optic, called a collimating channel array (CCA), consists of micron-scale, lithographically-fabricated arrays of collimating channels, all directed towards a single source position. Due to the limited absorbing power of silicon, the useful energy range of these optics was limited to fluorescence emission below about 10 keV. Here, we report fabrication of CCAs from germanium substrates, and demonstrate their practical use for CXRF up to 20 keV. Specifically we demonstrate a nearly energy-independent critical spatial resolution $d_R$ of 2.1$\pm$0.17 \um from 2-20 keV, as well as excellent background reduction compared to silicon-based CCAs throughout this energy range. Design details of the optic and background-reduction holder are described. Two versions of the optic are now available upon request at the beamline 20ID-B, Advanced Photon Source (APS) - Argonne National Laboratory.

  • Germanium collimating micro-channel arrays for high resolution, high energy confocal X-ray fluorescence microscopy

    by David N. Agyeman-Budu, Sanjukta Choudhury, Ian Coulthard, Robert Gordon, Emil Hallin, Arthur R. Woll

    Confocal x-ray fluorescence microscopy (CXRF) allows direct detection of x-ray fluorescence from a micron-scale 3D volume of an extended, unthinned sample. We have previously demonstrated the use of a novel collection optic, fabricated from silicon, that improves the spatial resolution of this approach by an order of magnitude over CXRF using polycapillaries. The optic, called a collimating channel array (CCA), consists of micron-scale, lithographically-fabricated arrays of collimating channels, all directed towards a single source position. Due to the limited absorbing power of silicon, the useful energy range of these optics was limited to fluorescence emission below about 10 keV. Here, we report fabrication of CCAs from germanium substrates, and demonstrate their practical use for CXRF up to 20 keV. Specifically we demonstrate a nearly energy-independent critical spatial resolution d R of 2.1±0.17 µm from 2-20 keV, as well as excellent background reduction compared to silicon-based CCAs throughout this energy range. Design details of the optic and background-reduction holder are described. Two versions of the optic are now available upon request at the beamline 20ID-B, Advanced Photon Source (APS) - Argonne National Laboratory.


  • Application of a spoked channel array to confocal X-ray fluorescence imaging and X-ray absorption spectroscopy of medieval stained glass

    by Sanjukta Choudhury, Josef Hormes, David N. Agyeman-Budu, Arthur R. Woll, Graham N. George, Ian Coulthard, Ingrid J. Pickering

    Confocal X-ray fluorescence imaging can determine the spatial distribution of elements in a depth-selective manner. The closely related technique of confocal X-ray absorption spectroscopy can reveal the chemical form of an element at a specific volume element in three dimensional space. Confocal measurement offers increased accuracy and avoids physical sectioning or ablative depth profiling methods, thus preserving sample integrity. At present, a polycapillary mounted on the detector is the common optical element used to complete the confocal configuration. Here we demonstrate implementation of a novel collection optic, a lithographically fabricated spoked channel array, to achieve the confocal configuration at beamline 20-ID, advanced photon source. The advantages of employing spoked channel arrays include improved spatial resolution and energy-independent probing volume. By employing this optic, three dimensional distributions of Fe, Ca and Mn and the localized chemical form of Fe were measured in the intact corrosion layer of an ancient stained glass sample obtained from 13th Century Paderborn Cathedral, Germany. Implementation of the optic enabled superior resolution depth selectivity in the intact corrosion layer and measurement of elemental distribution and speciation in a highly localized manner within the layer with improved signal to noise. The results show that both the composition and the chemical form vary as a function of three dimensional location in the corrosion layer. This observation is contrary to expectations from simple corrosion models assuming leaching processes and indicates that metal chemistry in these layers is quite complex.