Akshay Vij
Akshay Vij has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Avanija Reddy
Missouri School of Dentistry & Oral Health, A.T. Still University St. Louis Missouri
1 shared publicationJacob Palmer
Missouri School of Dentistry & Oral Health A.T. Still, University of Health Sciences Saint Louis
1 shared publicationLogan Carter
Missouri School of Dentistry & Oral Health A.T. Still, University of Health Sciences Saint Louis
1 shared publicationMinaal Verma
Department of Restorative Dentistry & Implant Dentistry SIU School of Dental Medicine Alton Illinois USA
1 shared publicationNoah Barnes
Missouri School of Dentistry & Oral Health A.T. Still, University of Health Sciences Saint Louis
1 shared publicationPrashanth Konatham Haribabu
Specialty Care Unit, Oral & Maxillofacial Surgery, Missouri School of Dentistry & Oral Health A.T. Still University Saint Louis Missouri USA
1 shared publication
Latest Publications
- 27 October 2025
- Published by Taylor & Francis in Journal of Occupational and Environmental Hygiene
- Vol. 23 (2) , 124-129
Examining the effects of custom 3D-printed respirator frames on the seal of KN95 masks: A pilot study
During most of the COVID-19 pandemic, N95 respirators were in short supply, creating a need for alternative solutions to protect healthcare workers and others from infection. The current pilot study was conducted to determine whether using a KN95 respirator with a custom respirator frame would be an effective alternative to an N95 respirator. Using the Bellus3D Dental Pro application on an iPhone, a 3D face scan was obtained for six adult volunteers (three women, three men), and a custom mask frame was 3D printed in gray resin. Next, a PortaCount Fit Tester was used to test the fit of a KN95 respirator, a KN95 respirator with the custom mask frame, and an N95 respirator. The three respirator configurations were compared for overall fit and fit during four day-to-day movements (bending over, talking, and moving the head side to side or up and down). Fit factor values could range from 1-200, and a value of 100 was considered the minimum to meet established safety specifications. The mean (SD) overall fit factor was 12.1 (1.8) for the KN95 respirator, 195.4 (11.2) for the KN95 respirator with the custom mask frame, and 170.0 (38.3) for the N95 respirator. Differences were found between the three configurations for all outcomes (all p < .004). Post hoc comparisons indicated differences between the KN95 respirator and KN95 respirator with the custom mask frame for all outcomes (all p < .02) and between the KN95 respirator with the custom mask frame and N95 respirator for moving the head side to side (p = .04). Results of the pilot current study suggested using a KN95 respirator with a custom mask frame significantly improved the fit factor to meet existing safety specifications. In the future, healthcare workers and organizations should consider this configuration as an effective alternative to N95 respirators.
- 27 October 2025
- Published by Taylor & Francis in Journal of Occupational and Environmental Hygiene
- Vol. 23 (2) , 124-129
Examining the effects of custom 3D-printed respirator frames on the seal of KN95 masks: A pilot study
During most of the COVID-19 pandemic, N95 respirators were in short supply, creating a need for alternative solutions to protect healthcare workers and others from infection. The current pilot study was conducted to determine whether using a KN95 respirator with a custom respirator frame would be an effective alternative to an N95 respirator. Using the Bellus3D Dental Pro application on an iPhone, a 3D face scan was obtained for six adult volunteers (three women, three men), and a custom mask frame was 3D printed in gray resin. Next, a PortaCount Fit Tester was used to test the fit of a KN95 respirator, a KN95 respirator with the custom mask frame, and an N95 respirator. The three respirator configurations were compared for overall fit and fit during four day-to-day movements (bending over, talking, and moving the head side to side or up and down). Fit factor values could range from 1-200, and a value of 100 was considered the minimum to meet established safety specifications. The mean (SD) overall fit factor was 12.1 (1.8) for the KN95 respirator, 195.4 (11.2) for the KN95 respirator with the custom mask frame, and 170.0 (38.3) for the N95 respirator. Differences were found between the three configurations for all outcomes (all p < .004). Post hoc comparisons indicated differences between the KN95 respirator and KN95 respirator with the custom mask frame for all outcomes (all p < .02) and between the KN95 respirator with the custom mask frame and N95 respirator for moving the head side to side (p = .04). Results of the pilot current study suggested using a KN95 respirator with a custom mask frame significantly improved the fit factor to meet existing safety specifications. In the future, healthcare workers and organizations should consider this configuration as an effective alternative to N95 respirators.
- Open Access
- 12 May 2023
- Published by Wiley in Clinical Case Reports
- Vol. 11 (5)
Model‐assisted marsupialization of a large odontogenic keratocyst in the maxillofacial region using a multicolored 3D‐printed model: A novel approach in surgical planning and teaching
Key Clinical Message: 3D printing can improve surgical planning and coordination between the healthcare team and serve as a valuable educational tool for students. Although the occurrence of odontogenic keratocysts (OKCs) in the maxillofacial region is not uncommon, their aggressive growth behavior requires advanced surgical techniques for minimal recurrence. The current case report describes the use of a multicolored 3D‐printed model as an interactive visual aid for the surgical planning and management of an OKC treated with a minimally invasive surgical decompression technique. A cone‐beam computed tomography scan of the patient showed a profound OKC involving the left side of the body of the mandible. A 3D printer was used to print a multicolor resin model of the patient's OKC lesion within the mandible. The printed model was successfully used as a planning tool for surgical intervention (i.e., marsupialization and enucleation) of the OKC. The model was also used as a handheld interactive visual aid for dental students, so they could more effectively understand the anatomical and surgical complexity of the case. The novel use of the multicolor 3D‐printed model for treatment of this OKC improved visualization of the lesion during surgical planning and was a valuable teaching tool for educational discussion of this case.
- 12 May 2023
- Published by Wiley in Clinical Case Reports
- Vol. 11 (5)
Open AccessModel‐assisted marsupialization of a large odontogenic keratocyst in the maxillofacial region using a multicolored 3D‐printed model: A novel approach in surgical planning and teaching
Key Clinical Message: 3D printing can improve surgical planning and coordination between the healthcare team and serve as a valuable educational tool for students. Although the occurrence of odontogenic keratocysts (OKCs) in the maxillofacial region is not uncommon, their aggressive growth behavior requires advanced surgical techniques for minimal recurrence. The current case report describes the use of a multicolored 3D‐printed model as an interactive visual aid for the surgical planning and management of an OKC treated with a minimally invasive surgical decompression technique. A cone‐beam computed tomography scan of the patient showed a profound OKC involving the left side of the body of the mandible. A 3D printer was used to print a multicolor resin model of the patient's OKC lesion within the mandible. The printed model was successfully used as a planning tool for surgical intervention (i.e., marsupialization and enucleation) of the OKC. The model was also used as a handheld interactive visual aid for dental students, so they could more effectively understand the anatomical and surgical complexity of the case. The novel use of the multicolor 3D‐printed model for treatment of this OKC improved visualization of the lesion during surgical planning and was a valuable teaching tool for educational discussion of this case.
- Open Access
- 1 July 2020
- Published by Wiley in Clinical Case Reports
- Vol. 8 (7) , 1274-1276
Using digital impressions to fabricate space maintainers: A case report
Digital impressions improve patient experience and compliance. Digital impressions enable dental offices to collaborate and work with distant dental laboratories and specialists with ease. Although the initial cost of acquiring an intraoral scanner is significant, its use has the potential to reduce the cost per procedure.
- 1 July 2020
- Published by Wiley in Clinical Case Reports
- Vol. 8 (7) , 1274-1276
Open AccessUsing digital impressions to fabricate space maintainers: A case report
Digital impressions improve patient experience and compliance. Digital impressions enable dental offices to collaborate and work with distant dental laboratories and specialists with ease. Although the initial cost of acquiring an intraoral scanner is significant, its use has the potential to reduce the cost per procedure.