Pere Perez-Millan
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Pere Perez-Millan has a total of 114 co-authors. Here are the top co-authors by number of shared publications:
- Miguel Vicente Andres
ICMUV, University of Valencia
32 shared publications - José Luis Cruz
Universitat de València
21 shared publications - Andreas Wiberg
California Institute for Telecommunications and Information Technologies, University of California San Diego, La Jolla, CA, USA
6 shared publications - Giovanni Serafino
Scuola Superiore Sant’Anna, Pisa, Italy
6 shared publications Guillermo E. Villanueva
Nanophotonics Technology Center, Universidad Politécnica de Valencia, Valencia, Spain
6 shared publications- Jesús Palací
Universidad Rey Juan Carlos
6 shared publications
Latest Publications
- Open Access
- 22 November 2024
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 7 (1) , 015001
1 GHz fundamental repetition rate thulium-doped all-polarization maintaining modelocked fiber laser
In this work, we present a passively modelocked all-fiber laser that fully retains polarization with a fundamental repetition rate of 1 GHz. The whole cavity consists of a 106 mm-long highly-Tm-doped polarization-maintaining fiber with a dichroic mirror on one end and a semiconductor saturable absorber mirror on the other. We experimentally characterized the output of this laser, which emits a train of transform-limited light pulses with a temporal width of 520 fs at the central optical wavelength of 1.96 μm. The high stability of this laser was also experimentally verified. Together with this, a detailed theoretical model was developed, confirming the experimental results.
- 22 November 2024
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 7 (1) , 015001
Open Access1 GHz fundamental repetition rate thulium-doped all-polarization maintaining modelocked fiber laser
In this work, we present a passively modelocked all-fiber laser that fully retains polarization with a fundamental repetition rate of 1 GHz. The whole cavity consists of a 106 mm-long highly-Tm-doped polarization-maintaining fiber with a dichroic mirror on one end and a semiconductor saturable absorber mirror on the other. We experimentally characterized the output of this laser, which emits a train of transform-limited light pulses with a temporal width of 520 fs at the central optical wavelength of 1.96 μm. The high stability of this laser was also experimentally verified. Together with this, a detailed theoretical model was developed, confirming the experimental results.
- Open Access
- 3 September 2021
- Published by Springer Nature in Research Square
Few-cycle all-fibre supercontinuum laser for ultrabroadband multimodal nonlinear microscopy
Temporally coherent supercontinuum sources constitute an attractive alternative to bulk crystal-based sources of few-cycle light pulses. We present a monolithic fibre-optic configuration for generating transform-limited temporally coherent supercontinuum pulses with central wavelength at 1.06 mm and duration as short as 13.0 fs (3.7 optical cycles). The supercontinuum is generated by the action of self-phase modulation and optical wave breaking when pumping an all-normal dispersion photonic crystal fibre with pulses of hundreds of fs duration produced by all-fibre chirped pulsed amplification. Avoidance of free-space propagation between stages confers unequalled robustness, efficiency and cost-effectiveness to this novel configuration. Collectively, the features of all-fibre few-cycle pulsed sources make them powerful tools for applications benefitting from the ultrabroadband spectra and ultrashort pulse durations. Here we exploit these features and the deep penetration of light in biological tissues at the spectral region of 1 mm, to demonstrate their successful performance in ultrabroadband multispectral and multimodal nonlinear microscopy.
- 3 September 2021
- Published by Springer Nature in Research Square
Open AccessFew-cycle all-fibre supercontinuum laser for ultrabroadband multimodal nonlinear microscopy
Temporally coherent supercontinuum sources constitute an attractive alternative to bulk crystal-based sources of few-cycle light pulses. We present a monolithic fibre-optic configuration for generating transform-limited temporally coherent supercontinuum pulses with central wavelength at 1.06 mm and duration as short as 13.0 fs (3.7 optical cycles). The supercontinuum is generated by the action of self-phase modulation and optical wave breaking when pumping an all-normal dispersion photonic crystal fibre with pulses of hundreds of fs duration produced by all-fibre chirped pulsed amplification. Avoidance of free-space propagation between stages confers unequalled robustness, efficiency and cost-effectiveness to this novel configuration. Collectively, the features of all-fibre few-cycle pulsed sources make them powerful tools for applications benefitting from the ultrabroadband spectra and ultrashort pulse durations. Here we exploit these features and the deep penetration of light in biological tissues at the spectral region of 1 mm, to demonstrate their successful performance in ultrabroadband multispectral and multimodal nonlinear microscopy.
- Open Access
- 29 April 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-10
Detection and elimination of pulse train instabilities in broadband fibre lasers using dispersion scan
We use self-calibrating dispersion scan to experimentally detect and quantify the presence of pulse train instabilities in ultrashort laser pulse trains. We numerically test our approach against two different types of pulse instability, namely second-order phase fluctuations and random phase instability, where the introduction of an adequate metric enables univocally quantifying the amount of instability. The approach is experimentally demonstrated with a supercontinuum fibre laser, where we observe and identify pulse train instabilities due to nonlinear propagation effects under anomalous dispersion conditions in the photonic crystal fibre used for spectral broadening. By replacing the latter with an all-normal dispersion fibre, we effectively correct the pulse train instability and increase the bandwidth of the generated coherent spectrum. This is further confirmed by temporal compression and measurement of the output pulses down to 15 fs using dispersion scan.
- 29 April 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-10
Open AccessDetection and elimination of pulse train instabilities in broadband fibre lasers using dispersion scan
We use self-calibrating dispersion scan to experimentally detect and quantify the presence of pulse train instabilities in ultrashort laser pulse trains. We numerically test our approach against two different types of pulse instability, namely second-order phase fluctuations and random phase instability, where the introduction of an adequate metric enables univocally quantifying the amount of instability. The approach is experimentally demonstrated with a supercontinuum fibre laser, where we observe and identify pulse train instabilities due to nonlinear propagation effects under anomalous dispersion conditions in the photonic crystal fibre used for spectral broadening. By replacing the latter with an all-normal dispersion fibre, we effectively correct the pulse train instability and increase the bandwidth of the generated coherent spectrum. This is further confirmed by temporal compression and measurement of the output pulses down to 15 fs using dispersion scan.
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Evaluation of the Coherent Artifact in Ultrashort Laser Pulses using D-Scan and Its Application to Broadband Fiber Lasers
In most techniques used for the temporal characterization of high-repetition rate ultrafast lasers, the resulting measurement is usually integrated over a large number of pulses. Shot-to-shot fluctuations within the pulse train are therefore averaged in the acquisition. These variations may be of a different nature depending on the laser source and the nonlinear processes involved. In previous works, some of these techniques were tested through numerical simulations and their sensitivity to this phenomenon — known as the coherent artifact — has been analyzed by adding random phases to the pulses and by introducing multiple pulse instabilities in the pulse train [1–3].
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Evaluation of the Coherent Artifact in Ultrashort Laser Pulses using D-Scan and Its Application to Broadband Fiber Lasers
In most techniques used for the temporal characterization of high-repetition rate ultrafast lasers, the resulting measurement is usually integrated over a large number of pulses. Shot-to-shot fluctuations within the pulse train are therefore averaged in the acquisition. These variations may be of a different nature depending on the laser source and the nonlinear processes involved. In previous works, some of these techniques were tested through numerical simulations and their sensitivity to this phenomenon — known as the coherent artifact — has been analyzed by adding random phases to the pulses and by introducing multiple pulse instabilities in the pulse train [1–3].
- Open Access
Temporal Distribution Measurement of the Parametric Spectral Gain in a Photonic Crystal Fiber Pumped by a Chirped Pulse
The temporal distribution of the spectral parametric gain was experimentally investigated when a chirped pump pulse was injected into a photonic crystal fiber. A pump-probe experiment was developed and the important characteristics were measured as the chirp of the pump, the signal pulse, and the gain of the parametric amplifier. We highlight that the amplified spectrum depends strongly on the instantaneous pump wavelength and that the temporal evolution of the wavelength at maximum gain is not monotonic. This behavior is significantly different from the case in which the chirped pump has a constant peak power. This measurement will be very important to efficiently include parametric amplifiers in laser systems delivering ultra-short pulses.
Open AccessTemporal Distribution Measurement of the Parametric Spectral Gain in a Photonic Crystal Fiber Pumped by a Chirped Pulse
The temporal distribution of the spectral parametric gain was experimentally investigated when a chirped pump pulse was injected into a photonic crystal fiber. A pump-probe experiment was developed and the important characteristics were measured as the chirp of the pump, the signal pulse, and the gain of the parametric amplifier. We highlight that the amplified spectrum depends strongly on the instantaneous pump wavelength and that the temporal evolution of the wavelength at maximum gain is not monotonic. This behavior is significantly different from the case in which the chirped pump has a constant peak power. This measurement will be very important to efficiently include parametric amplifiers in laser systems delivering ultra-short pulses.
- 9 May 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10681, 1068115
Synchronous interferometric broadband measurement of dispersion applied to manufacturing optimization of microstructured optical fibers
Supercontinuum (SC) sources offer very significant advantages for imaging and characterization of materials: full VIS-NIR spectrum availability, high spectral power density, reduced temporal coherence, among others. Certain applications require a very accurately customized emission spectrum, which in turn requires reliable tools to measure the dispersion spectra of the microstructured optical fiber of the SC source with very high spectral resolution and very short acquisition time. This measurement to be done ideally on the fly, while manufacturing the fiber, in order to fine tune the drawing variables to match the aimed dispersion profile in real time. In this work we present an interferometric method to measure chromatic dispersion using a pulsed FYLA SCT1000 supercontinuum. Very high-resolution dispersion measurement is obtained by optimization of the visibility of interferometric fringes, which is achieved by a fast synchronization of pulses overlapping. FYLA SCT1000 Supercontinuum offers a very broadband emission with SPD close to 1 mW/nm, consisting of a train of white pulses of few ps timewidth, trigger output for synchronized measurements and very stable emission, with full spectrum average power stability < 0.5% and peak to peak stability < 1% in VIS region and < 0.6% in NIR region (stabilities refer to standard deviation over mean value). The sample to measure, which can be an optical fiber or any photonic device, is placed in one of the arms of a Michelson interferometer. Interferences obtained with different displacements give values of dispersion at different wavelengths. The standard way is to use a lamp or a SLED at each band [1,2]. This makes the measurement long and tedious. Lamps or SLEDs can be replaced by a single FYLA SCT1000 to obtain the dispersion curve in a fast and very robust way. Since the source is pulsed with a fixed rep rate, delay can be easily controlled to overlap properly light from arms of the interferometer. With a single source, the complete dispersion curve is obtained with resolution below 1 nm. In this work this synchronous interferometric method to measure dispersion is used to optimize the design and manufacture of microstructured optical fibers through an iterative protocol implemented in the fiber drawing process.
- 9 May 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10681, 1068115
Synchronous interferometric broadband measurement of dispersion applied to manufacturing optimization of microstructured optical fibers
Supercontinuum (SC) sources offer very significant advantages for imaging and characterization of materials: full VIS-NIR spectrum availability, high spectral power density, reduced temporal coherence, among others. Certain applications require a very accurately customized emission spectrum, which in turn requires reliable tools to measure the dispersion spectra of the microstructured optical fiber of the SC source with very high spectral resolution and very short acquisition time. This measurement to be done ideally on the fly, while manufacturing the fiber, in order to fine tune the drawing variables to match the aimed dispersion profile in real time. In this work we present an interferometric method to measure chromatic dispersion using a pulsed FYLA SCT1000 supercontinuum. Very high-resolution dispersion measurement is obtained by optimization of the visibility of interferometric fringes, which is achieved by a fast synchronization of pulses overlapping. FYLA SCT1000 Supercontinuum offers a very broadband emission with SPD close to 1 mW/nm, consisting of a train of white pulses of few ps timewidth, trigger output for synchronized measurements and very stable emission, with full spectrum average power stability < 0.5% and peak to peak stability < 1% in VIS region and < 0.6% in NIR region (stabilities refer to standard deviation over mean value). The sample to measure, which can be an optical fiber or any photonic device, is placed in one of the arms of a Michelson interferometer. Interferences obtained with different displacements give values of dispersion at different wavelengths. The standard way is to use a lamp or a SLED at each band [1,2]. This makes the measurement long and tedious. Lamps or SLEDs can be replaced by a single FYLA SCT1000 to obtain the dispersion curve in a fast and very robust way. Since the source is pulsed with a fixed rep rate, delay can be easily controlled to overlap properly light from arms of the interferometer. With a single source, the complete dispersion curve is obtained with resolution below 1 nm. In this work this synchronous interferometric method to measure dispersion is used to optimize the design and manufacture of microstructured optical fibers through an iterative protocol implemented in the fiber drawing process.
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Supercontinuum based solutions focused on industrial customer needs
FYLA manufactures ns, ps and fs proprietary fiber lasers in the range of 1, 1.5, 2.0 μm wavelengths and supercontinuum VIS to NIR bands. The go-to-market approach of FYLA is based on an R+D strategy deeply focused on our (current and future) customer needs. This paper presents a selection of advanced solutions based in supercontinuum illumination that have been developed to satisfy such needs and the market sectors where they are framed.
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Supercontinuum based solutions focused on industrial customer needs
FYLA manufactures ns, ps and fs proprietary fiber lasers in the range of 1, 1.5, 2.0 μm wavelengths and supercontinuum VIS to NIR bands. The go-to-market approach of FYLA is based on an R+D strategy deeply focused on our (current and future) customer needs. This paper presents a selection of advanced solutions based in supercontinuum illumination that have been developed to satisfy such needs and the market sectors where they are framed.
- 10 July 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 33 (19) , 4039-4049
Comprehensive Theoretical and Experimental Study of Short- and Long-Term Stability in a Passively Mode-Locked Solitonic Fiber Laser
We demonstrate the short- and long-term stable operation of an all-polarization-maintained Fabry-Pérot cavity passively mode-locked fiber laser. The laser operates in an all-anomalous-dispersion solitonic regime. Laser stability is studied by a variety of measurements, which confirm the high stability of the laser in the temporal and spectral-both optical and electrical-domains. Pulse durations of 540 fs, period-relative time jitters of ~0.015 0 / 00 , and long-term uninterrumped operation with 0.4% variation (standard deviation) in the average output power are obtained. The highly stable operation of the laser oscillator was maintained after amplifying the laser output with a conventional EDFA. Pulse durations of ~244 fs, period-relative time jitters of ~0.019 0 / 00 , and an average output power of 20 mW were obtained after amplification, while maintaining the 100-dB signal-to-noise ratio of the laser oscillator measured at 500-Hz offset from the fundamental harmonic frequency. The theoretical validation of our experimental results is based on solutions of the Nonlinear Schrödinger Equation. We demonstrate that wavelength and z -position dependences of the active medium gain must be taken into account for an accurate correspondence with the experimental properties of the laser.
- 10 July 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 33 (19) , 4039-4049
Comprehensive Theoretical and Experimental Study of Short- and Long-Term Stability in a Passively Mode-Locked Solitonic Fiber Laser
We demonstrate the short- and long-term stable operation of an all-polarization-maintained Fabry-Pérot cavity passively mode-locked fiber laser. The laser operates in an all-anomalous-dispersion solitonic regime. Laser stability is studied by a variety of measurements, which confirm the high stability of the laser in the temporal and spectral-both optical and electrical-domains. Pulse durations of 540 fs, period-relative time jitters of ~0.015 0 / 00 , and long-term uninterrumped operation with 0.4% variation (standard deviation) in the average output power are obtained. The highly stable operation of the laser oscillator was maintained after amplifying the laser output with a conventional EDFA. Pulse durations of ~244 fs, period-relative time jitters of ~0.019 0 / 00 , and an average output power of 20 mW were obtained after amplification, while maintaining the 100-dB signal-to-noise ratio of the laser oscillator measured at 500-Hz offset from the fundamental harmonic frequency. The theoretical validation of our experimental results is based on solutions of the Nonlinear Schrödinger Equation. We demonstrate that wavelength and z -position dependences of the active medium gain must be taken into account for an accurate correspondence with the experimental properties of the laser.
- 14 April 2015
- Published by SPIE-Intl Soc Optical Eng
- p. 93431X-93431X-8
Short-and-long-term highly stable oscillation and amplification of linearly polarized passively mode-locked solitonic fiber laser resonators
- 14 April 2015
- Published by SPIE-Intl Soc Optical Eng
- p. 93431X-93431X-8
Short-and-long-term highly stable oscillation and amplification of linearly polarized passively mode-locked solitonic fiber laser resonators
- 12 October 2014
- Published by Springer Nature in Applied Physics B
- Vol. 117 (4) , 1173-1181
Phase recovery by using optical fiber dispersion and pulse pre-stretching
- 12 October 2014
- Published by Springer Nature in Applied Physics B
- Vol. 117 (4) , 1173-1181
Phase recovery by using optical fiber dispersion and pulse pre-stretching