Mahdi Naseri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mahdi Naseri has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Warren Batchelor
Bioresource Processing Research Institute of Australia, Department of Chemical and Biological Engineering, Monash University, Clayton, VIC 3800, Australia
5 shared publications - Mostafa Dehghani
Bioresource Processing Research Institute of Australia, Department of Chemical and Biological Engineering, Monash University, Clayton, Victoria 3800, Australia
3 shared publications Humayun Nadeem
Bioresource Processing Research Institute of Australia, Department of Chemical and Biological Engineering, Monash University, Clayton, Victoria 3800, Australia
2 shared publications- Christine Browne
Bioresource Processing Research Institute of Australia (BioPRIA), Department of Chemical and Biological Engineering, Monash University, Clayton, Victoria 3800, Australia
1 shared publication George P Simon
Department of Materials Science and Engineering, Monash University, Clayton, Victoria 3800, Australia
1 shared publicationGeorge P. Simon
Department of Materials Science and Engineering, Monash University, Clayton, VIC 3800, Australia
1 shared publication
Latest Publications
- 15 March 2022
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 7 (4) , 951-959
Rapid Detection of Gram-Positive and -Negative Bacteria in Water Samples Using Mannan-Binding Lectin-Based Visual Biosensor
Waterborne bacterial infection is a health threat worldwide, making accurate and timely bacteria detection crucial to prevent waterborne disease outbreaks. Inspired by the intrinsic capability of mannan-binding lectin (MBL) in recognizing the pathogen-associated molecular patterns (PAMPs), a visual biosensor is developed here for the on-site detection of both Gram-positive and -negative bacteria. The biosensor was synthesized by immobilization of the MBL protein onto the blue carboxyl-functionalized polystyrene microparticles (PSM), which is then used in a two-step assay to detect bacterial cells in water samples. The first step involved a 20 min incubation following the MBL-PSM and calcium chloride solution addition to the samples. The second step was to add ethanol to the resultant blue mixture and observe the color change with the naked eye after 15 min. The biosensor had a binary (all-or-none) response, which in the presence of bacterial cells kept its blue color, while in their absence the color changed from blue to colorless. Testing the water samples spiked with four Gram-negative bacteria including Acinetobacter baumannii, Escherichia coli, Klebsiella pneumoniae, and Pseudomonas aeruginosa and two Gram-positive bacteria of Enterococcus faecalis and Staphylococcus aureus showed that the biosensor could detect all tested bacteria with a concentration as low as 101.5 CFU/ml. The performance of biosensor using the water samples from a water treatment plant also confirmed its capability to detect the pathogens in real-life water samples without the need for instrumentation.
- 15 March 2022
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 7 (4) , 951-959
Rapid Detection of Gram-Positive and -Negative Bacteria in Water Samples Using Mannan-Binding Lectin-Based Visual Biosensor
Waterborne bacterial infection is a health threat worldwide, making accurate and timely bacteria detection crucial to prevent waterborne disease outbreaks. Inspired by the intrinsic capability of mannan-binding lectin (MBL) in recognizing the pathogen-associated molecular patterns (PAMPs), a visual biosensor is developed here for the on-site detection of both Gram-positive and -negative bacteria. The biosensor was synthesized by immobilization of the MBL protein onto the blue carboxyl-functionalized polystyrene microparticles (PSM), which is then used in a two-step assay to detect bacterial cells in water samples. The first step involved a 20 min incubation following the MBL-PSM and calcium chloride solution addition to the samples. The second step was to add ethanol to the resultant blue mixture and observe the color change with the naked eye after 15 min. The biosensor had a binary (all-or-none) response, which in the presence of bacterial cells kept its blue color, while in their absence the color changed from blue to colorless. Testing the water samples spiked with four Gram-negative bacteria including Acinetobacter baumannii, Escherichia coli, Klebsiella pneumoniae, and Pseudomonas aeruginosa and two Gram-positive bacteria of Enterococcus faecalis and Staphylococcus aureus showed that the biosensor could detect all tested bacteria with a concentration as low as 101.5 CFU/ml. The performance of biosensor using the water samples from a water treatment plant also confirmed its capability to detect the pathogens in real-life water samples without the need for instrumentation.
- 8 June 2021
- Published by Wiley in Reviews in Medical Virology
- Vol. 32 (2) , e2263
ASSURED‐compliant point‐of‐care diagnostics for the detection of human viral infections
Viral disease outbreaks have been always a threat to global public health making affordable, rapid and accurate diagnostics highly important tools to slow down the spread of viruses and decrease the mortality rate. Point‐of‐care (POC) diagnostics have emerged as a strong tool for the diagnosis of viral infections, especially in countries where health‐care systems are inadequate to provide proper services to all citizens. According to the World Health Organization, an ideal POC diagnostic must be Affordable, Sensitive, Specific, User‐friendly, Rapid/Robust, Equipment‐free and Deliverable (ASSURED). This review surveys carefully each ASSURED criterion and identifies where existing viral POC diagnostics fail to meet these criteria. Given the widespread concern with plastic pollution, we also propose the addition of 'disposability' to the existing ASSURED criteria and consider the letter “D” as the representative of both Deliverable and Disposable. Next, the POC tests used for the diagnosis of several common human viral infections which met all the ASSURED criteria (ASSURED‐compliant) are described in detail. Finally, the future of ASSURED‐compliant POC diagnostics, capable of generating comparable results to the viral diagnostic gold standards, is discussed.
- 8 June 2021
- Published by Wiley in Reviews in Medical Virology
- Vol. 32 (2) , e2263
ASSURED‐compliant point‐of‐care diagnostics for the detection of human viral infections
Viral disease outbreaks have been always a threat to global public health making affordable, rapid and accurate diagnostics highly important tools to slow down the spread of viruses and decrease the mortality rate. Point‐of‐care (POC) diagnostics have emerged as a strong tool for the diagnosis of viral infections, especially in countries where health‐care systems are inadequate to provide proper services to all citizens. According to the World Health Organization, an ideal POC diagnostic must be Affordable, Sensitive, Specific, User‐friendly, Rapid/Robust, Equipment‐free and Deliverable (ASSURED). This review surveys carefully each ASSURED criterion and identifies where existing viral POC diagnostics fail to meet these criteria. Given the widespread concern with plastic pollution, we also propose the addition of 'disposability' to the existing ASSURED criteria and consider the letter “D” as the representative of both Deliverable and Disposable. Next, the POC tests used for the diagnosis of several common human viral infections which met all the ASSURED criteria (ASSURED‐compliant) are described in detail. Finally, the future of ASSURED‐compliant POC diagnostics, capable of generating comparable results to the viral diagnostic gold standards, is discussed.
- 1 December 2020
- Published by Elsevier in Carbohydrate Polymers
- Vol. 250, 116911
An energy efficient production of high moisture barrier nanocellulose/carboxymethyl cellulose films via spray-deposition technique
- 1 December 2020
- Published by Elsevier in Carbohydrate Polymers
- Vol. 250, 116911
An energy efficient production of high moisture barrier nanocellulose/carboxymethyl cellulose films via spray-deposition technique
- 15 April 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (10) , 7307-7316
Development of a Paper-Based Microfluidic System for a Continuous High-Flow-Rate Fluid Manipulation
The current study describes the development of a disposable paper-based microfluidic system which unlike its predecessors that are only capable of processing a small amount of fluid, can continuously process the fluid at a high flow rate of up to 1.5 mL/min. The fabrication procedure was clean room-free and robust, involving the use of a CO2 laser to engrave the microchannels on a paper substrate, followed by alkenyl ketene dimer treatment to hydrophobize the paper and lamination. The microchannel down to a minimum depth of ~80 µm with the average roughness of ~8 µm was engraved on the substrate. As a proof of concept, the applicability of this system to enrich the microparticles based on the inertial focusing mechanism was tested. This new generation of paper-based microfluidic system can be potentially used for the diagnostic applications where the analyte is low in quantity and processing a large volume of fluid sample is required.
- 15 April 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (10) , 7307-7316
Development of a Paper-Based Microfluidic System for a Continuous High-Flow-Rate Fluid Manipulation
The current study describes the development of a disposable paper-based microfluidic system which unlike its predecessors that are only capable of processing a small amount of fluid, can continuously process the fluid at a high flow rate of up to 1.5 mL/min. The fabrication procedure was clean room-free and robust, involving the use of a CO2 laser to engrave the microchannels on a paper substrate, followed by alkenyl ketene dimer treatment to hydrophobize the paper and lamination. The microchannel down to a minimum depth of ~80 µm with the average roughness of ~8 µm was engraved on the substrate. As a proof of concept, the applicability of this system to enrich the microparticles based on the inertial focusing mechanism was tested. This new generation of paper-based microfluidic system can be potentially used for the diagnostic applications where the analyte is low in quantity and processing a large volume of fluid sample is required.