Sean Doherty
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sean Doherty has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Anne Vanhoestenberghe
Aspire Centre for Rehabilitation Engineering and Assistive Technology, University College London, London, UK
2 shared publicationsRizwan Hamid
London Spinal Cord Injury Centre, Royal National Orthopaedic Hospital, London, UK
2 shared publicationsBrian Andrews
Nuffield Department of Surgical Sciences
1 shared publicationFelix Peterken
University of Oxford
1 shared publicationGraham Creasey
Stanford University
1 shared publicationLynsey D. Duffell
Aspire Centre for Rehabilitation Engineering and Assistive Technology, University College London, London, UK
1 shared publication
Latest Publications
- Open Access
- 1 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2021, 6406-6411
Adapting the Finetech-Brindley Sacral Anterior Root Stimulator for Bioelectronic Medicine
The Finetech-Brindley Sacral Anterior Root Stimulator (SARS) is a low cost and reliable system. The architecture has been used for various bioelectric treatments, including several thousand implanted systems for restoring bladder function following spinal cord injury (SCI). Extending the operational frequency range would expand the capability of the system; enabling, for example, the exploration of eliminating the rhizotomy through an electrical nerve block. The distributed architecture of the SARS system enables stimulation parameters to be adjusted without modifying the implant design or manufacturing. To explore the design degrees-of-freedom, a circuit simulation was created and validated using a modified SARS system that supported stimulation frequencies up to 600 Hz. The simulation was also used to explore high frequency (up to 30kHz) behaviour, and to determine the constraints on charge delivered at the higher rates. A key constraint found was the DC blocking capacitors, designed originally for low frequency operation, not fully discharging within a shortened stimulation period. Within these current implant constraints, we demonstrate the potential capability for higher frequency operation that is consistent with presynaptic stimulation block, and also define targeted circuit improvements for future extension of stimulation capability.
- 1 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2021, 6406-6411
Open AccessAdapting the Finetech-Brindley Sacral Anterior Root Stimulator for Bioelectronic Medicine
The Finetech-Brindley Sacral Anterior Root Stimulator (SARS) is a low cost and reliable system. The architecture has been used for various bioelectric treatments, including several thousand implanted systems for restoring bladder function following spinal cord injury (SCI). Extending the operational frequency range would expand the capability of the system; enabling, for example, the exploration of eliminating the rhizotomy through an electrical nerve block. The distributed architecture of the SARS system enables stimulation parameters to be adjusted without modifying the implant design or manufacturing. To explore the design degrees-of-freedom, a circuit simulation was created and validated using a modified SARS system that supported stimulation frequencies up to 600 Hz. The simulation was also used to explore high frequency (up to 30kHz) behaviour, and to determine the constraints on charge delivered at the higher rates. A key constraint found was the DC blocking capacitors, designed originally for low frequency operation, not fully discharging within a shortened stimulation period. Within these current implant constraints, we demonstrate the potential capability for higher frequency operation that is consistent with presynaptic stimulation block, and also define targeted circuit improvements for future extension of stimulation capability.
- 30 April 2020
- Published by Springer Nature in Spinal Cord Series and Cases
- Vol. 6 (1) , 1-8
Ambulatory urodynamic monitoring assessment of dorsal genital nerve stimulation for suppression of involuntary detrusor contractions following spinal cord injury: a pilot study
Study design A prospective interventional pilot study using within-individual comparisons. Objectives To assess the effect of dorsal genital nerve stimulation (DGNS) on urine-storage parameters in participants with spinal cord injury (SCI) and neurogenic detrusor overactivity (NDO) during natural bladder filling. Setting The London Spinal Cord Injuries Centre at the Royal National Orthopaedic Hospital, Stanmore, UK. Methods Ambulatory urodynamic monitoring (AUM) was carried out with and without DGNS, before and after a week of using DGNS at home. DGNS was applied on-demand by four participants with bladder sensation, and both continuously and intermittently by one participant with absent sensation. A Wilcoxon sign-rank test was used to test paired results of changes within an AUM session. Results Urodynamic outcomes were improved using DGNS. Bladder capacity was increased from 244 ± 59 to 346 ± 61 ml (p = 0.0078), a mean change of 46 ± 25%. Maximum detrusor pressure was decreased from 58 ± 18 to 47 ± 18 cmH2O (p = 0.0156), a change of 17 ± 13%, and average peak detrusor pressure was decreased from 56 ± 16 to 31 ± 128 cmH2O (p = 0.0156), a mean reduction of 50 ± 19%. There was an increase in the number of detrusor contractions from the first involuntary detrusor contraction to a strong desire, urgency or incontinence, from 1.5 ± 1.4 to 4.3 ± 1.7, and an increase in time of 23 ± 22 min. There were no changes in baseline outcomes following home use of DGNS. Conclusions DGNS may be applied on-demand, intermittently or continuously, to increase bladder capacity, decrease storage pressures and provide extra time. Improvements were made in addition to existing antimuscarinic medication regimes.
- 30 April 2020
- Published by Springer Nature in Spinal Cord Series and Cases
- Vol. 6 (1) , 1-8
Ambulatory urodynamic monitoring assessment of dorsal genital nerve stimulation for suppression of involuntary detrusor contractions following spinal cord injury: a pilot study
Study design A prospective interventional pilot study using within-individual comparisons. Objectives To assess the effect of dorsal genital nerve stimulation (DGNS) on urine-storage parameters in participants with spinal cord injury (SCI) and neurogenic detrusor overactivity (NDO) during natural bladder filling. Setting The London Spinal Cord Injuries Centre at the Royal National Orthopaedic Hospital, Stanmore, UK. Methods Ambulatory urodynamic monitoring (AUM) was carried out with and without DGNS, before and after a week of using DGNS at home. DGNS was applied on-demand by four participants with bladder sensation, and both continuously and intermittently by one participant with absent sensation. A Wilcoxon sign-rank test was used to test paired results of changes within an AUM session. Results Urodynamic outcomes were improved using DGNS. Bladder capacity was increased from 244 ± 59 to 346 ± 61 ml (p = 0.0078), a mean change of 46 ± 25%. Maximum detrusor pressure was decreased from 58 ± 18 to 47 ± 18 cmH2O (p = 0.0156), a change of 17 ± 13%, and average peak detrusor pressure was decreased from 56 ± 16 to 31 ± 128 cmH2O (p = 0.0156), a mean reduction of 50 ± 19%. There was an increase in the number of detrusor contractions from the first involuntary detrusor contraction to a strong desire, urgency or incontinence, from 1.5 ± 1.4 to 4.3 ± 1.7, and an increase in time of 23 ± 22 min. There were no changes in baseline outcomes following home use of DGNS. Conclusions DGNS may be applied on-demand, intermittently or continuously, to increase bladder capacity, decrease storage pressures and provide extra time. Improvements were made in addition to existing antimuscarinic medication regimes.
- Open Access
- 17 December 2019
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 13, 1360
A Urodynamic Comparison of Neural Targets for Transcutaneous Electrical Stimulation to Acutely Suppress Detrusor Contractions Following Spinal Cord Injury
Objectives: To assess and compare the effect of transcutaneous Dorsal Genital Nerve Stimulation (DGNS), Tibial Nerve Stimulation (TNS), Sacral Nerve Stimulation (SNS), and Spinal Stimulation (SS) on Neurogenic Detrusor Overactivity (NDO) and bladder capacity in people with Spinal Cord Injuries (SCI). Materials and Methods: Seven male participants with supra-sacral SCI were tested. Standard cystometry (CMG) was performed to assess bladder activity at baseline and with stimulation applied at each site. This was conducted over four separate sessions. All stimulation was monophasic, 15 Hz, 200 μS pulses and applied at maximum tolerable amplitude. Results were analysed against individual control results from within the same session. Results: Dorsal Genital Nerve Stimulation increased bladder capacity by 153 ± 146 ml (p = 0.016) or 117 ± 201%. DGNS, TNS and SNS all increased the volume held following the first reflex contraction, by 161 ± 175, 46 ± 62, and 34 ± 33 ml (p = 0.016, p = 0.031, p = 0.016), respectively. SS results showed small reduction of 33 ± 26 ml (p = 0.063) from baseline bladder capacity in five participants. Maximum Detrusor Pressure before leakage was increased during TNS, by 10 ± 13 cmH2O (p = 0.031) but was unchanged during stimulation of other sites. DGNS only was able to suppress at least one detrusor contraction in five participants and reduced first peak detrusor pressure below 40 cmH2O in these 5. Continuous TNS, SNS, and SS produced non-significant changes in bladder capacity from baseline, comparable to conditional stimulation. Increase in bladder capacity correlated with stimulation amplitude for DGNS but not TNS, SNS or SS. Conclusion: In this pilot study DGNS acutely suppressed detrusor contractions and increased bladder capacity whereas TNS, SNS, and SS did not. This is the first within individual comparison of surface stimulation sites for management of NDO in SCI individuals.
- 17 December 2019
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 13, 1360
Open AccessA Urodynamic Comparison of Neural Targets for Transcutaneous Electrical Stimulation to Acutely Suppress Detrusor Contractions Following Spinal Cord Injury
Objectives: To assess and compare the effect of transcutaneous Dorsal Genital Nerve Stimulation (DGNS), Tibial Nerve Stimulation (TNS), Sacral Nerve Stimulation (SNS), and Spinal Stimulation (SS) on Neurogenic Detrusor Overactivity (NDO) and bladder capacity in people with Spinal Cord Injuries (SCI). Materials and Methods: Seven male participants with supra-sacral SCI were tested. Standard cystometry (CMG) was performed to assess bladder activity at baseline and with stimulation applied at each site. This was conducted over four separate sessions. All stimulation was monophasic, 15 Hz, 200 μS pulses and applied at maximum tolerable amplitude. Results were analysed against individual control results from within the same session. Results: Dorsal Genital Nerve Stimulation increased bladder capacity by 153 ± 146 ml (p = 0.016) or 117 ± 201%. DGNS, TNS and SNS all increased the volume held following the first reflex contraction, by 161 ± 175, 46 ± 62, and 34 ± 33 ml (p = 0.016, p = 0.031, p = 0.016), respectively. SS results showed small reduction of 33 ± 26 ml (p = 0.063) from baseline bladder capacity in five participants. Maximum Detrusor Pressure before leakage was increased during TNS, by 10 ± 13 cmH2O (p = 0.031) but was unchanged during stimulation of other sites. DGNS only was able to suppress at least one detrusor contraction in five participants and reduced first peak detrusor pressure below 40 cmH2O in these 5. Continuous TNS, SNS, and SS produced non-significant changes in bladder capacity from baseline, comparable to conditional stimulation. Increase in bladder capacity correlated with stimulation amplitude for DGNS but not TNS, SNS or SS. Conclusion: In this pilot study DGNS acutely suppressed detrusor contractions and increased bladder capacity whereas TNS, SNS, and SS did not. This is the first within individual comparison of surface stimulation sites for management of NDO in SCI individuals.
- Open Access
- 21 August 2017
- Published by Springer Nature
Non-invasive neuromodulation for bladder suppression following spinal cord injury
- 21 August 2017
- Published by Springer Nature
Open AccessNon-invasive neuromodulation for bladder suppression following spinal cord injury
- Open Access
- 7 July 2017
- Published by Springer Nature
Neuromodulation for reducing neurogenic detrusor overactivity in SCI
- 7 July 2017
- Published by Springer Nature
Open AccessNeuromodulation for reducing neurogenic detrusor overactivity in SCI