Lukas Selzer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Lukas Selzer has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Florian Solzbacher
Department of Electrical and Computer Engineering, The University of Utah, Salt Lake City, UT, USA
2 shared publications - Stefan Odenbach
TU Dresden
2 shared publications Balaji Srikanthan
Blackrock Neurotech, 630 Komas Dr #200, Salt Lake City, Utah, 84108-1262, UNITED STATES
1 shared publication- Christopher Friedrich Reiche
University of Utah
1 shared publication - Johannes Mersch
Institute of Textile Machinery and High Performance Material Technology Technische Universität Dresden Dresden Germany
1 shared publication - Juan Pablo Botero
Department of Electrical and Computer Engineering, The University of Utah, 201 Presidents' Cir, Salt Lake City, Utah, 84112, UNITED STATES
1 shared publication
Latest Publications
- Open Access
- 1 October 2025
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 22 (5) , 056034
Neuralace: manufacture, parylene-C coating, and mechanical properties
Objective. This study investigates the mechanical properties of the Neuralace, a novel ultra-thin, high-channel-count mesh-type subdural electrode array, to characterize its mechanical compatibility with neural tissue (i.e., the forces exerted onto the brain upon conformation) for chronic brain–computer interface (BCI) applications. Approach. A full-factorial design of experiments was used to assess the effects of geometrical variations, orientation, and polymeric encapsulation on the stiffness of silicon-based Neuralace structures. A custom low-force four-point bending setup was developed to measure flexural stiffness in a physiologically relevant displacement range. Main results. The stiffness values of Neuralace structures ranged from 2.99 N m−1 to 7.21 N m−1, depending on the cell-wall thickness (CWT) of the lace, orientation, and parylene-C (PPXC) encapsulation. Orientation and CWT had the largest impact on the stiffness of the structures, while the effects of PPXC encapsulation were statistically significant but more subtle. The stiffest Neuralace configuration is expected to exert forces approximately 10–100 times lower than commercially available subdural implants would when conforming to the brain’s topology (considering a 60 mm radius of the gyrus). Significance. Subdural electrode arrays have traditionally been used for epilepsy monitoring and surgical planning. These arrays are now transitioning from short-term implantation in epilepsy monitoring to long-term use in BCIs, which requires consideration of the foreign body response to ensure long-term durability and functionality. Biocompatibility challenges, such as fibrotic encapsulation and reactive astrogliosis, highlight the need for conformal subdural implant designs that minimize mechanical stress on neural tissue. This study establishes a rigorous and reproducible framework for mechanical characterization of conformable neural implants and demonstrates the feasibility of tuning design parameters to reduce implant-induced mechanical stress on cortical tissue. The results support future development of chronic BCI-compatible subdural electrodes with improved biocompatibility through mechanical design.
- 1 October 2025
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 22 (5) , 056034
Open AccessNeuralace: manufacture, parylene-C coating, and mechanical properties
Objective. This study investigates the mechanical properties of the Neuralace, a novel ultra-thin, high-channel-count mesh-type subdural electrode array, to characterize its mechanical compatibility with neural tissue (i.e., the forces exerted onto the brain upon conformation) for chronic brain–computer interface (BCI) applications. Approach. A full-factorial design of experiments was used to assess the effects of geometrical variations, orientation, and polymeric encapsulation on the stiffness of silicon-based Neuralace structures. A custom low-force four-point bending setup was developed to measure flexural stiffness in a physiologically relevant displacement range. Main results. The stiffness values of Neuralace structures ranged from 2.99 N m−1 to 7.21 N m−1, depending on the cell-wall thickness (CWT) of the lace, orientation, and parylene-C (PPXC) encapsulation. Orientation and CWT had the largest impact on the stiffness of the structures, while the effects of PPXC encapsulation were statistically significant but more subtle. The stiffest Neuralace configuration is expected to exert forces approximately 10–100 times lower than commercially available subdural implants would when conforming to the brain’s topology (considering a 60 mm radius of the gyrus). Significance. Subdural electrode arrays have traditionally been used for epilepsy monitoring and surgical planning. These arrays are now transitioning from short-term implantation in epilepsy monitoring to long-term use in BCIs, which requires consideration of the foreign body response to ensure long-term durability and functionality. Biocompatibility challenges, such as fibrotic encapsulation and reactive astrogliosis, highlight the need for conformal subdural implant designs that minimize mechanical stress on neural tissue. This study establishes a rigorous and reproducible framework for mechanical characterization of conformable neural implants and demonstrates the feasibility of tuning design parameters to reduce implant-induced mechanical stress on cortical tissue. The results support future development of chronic BCI-compatible subdural electrodes with improved biocompatibility through mechanical design.
- Open Access
- 2 September 2024
- Published by Wiley in Advanced Intelligent Systems
- Vol. 7 (2)
Coil Formation and Biomimetic Performance Characterization of Twisted Coiled Polymer Artificial Muscles
A biological muscle's force is nonlinearly constrained by its current state (force, length, and speed) and state history. To investigate if artificial muscles can mimic (i.e. biomimetic) the complete mechanical state spectrum of biological muscles, this study uses a novel method to characterize twisted coiled polymer actuators (TCPAs) mechanically. Thus, comprehensive and reproducible test procedures are established to verify artificial muscle biomimetics regarding stress, strain, and strain rate combinations intrinsic to biological muscle. A rheometer performs novel high‐precision mechanical characterization methods to comprehensively verify biomimetic performance. Sample twist level, torque, length, force, and temperature are controlled and measured during twist‐induced coiling, heatsetting/annealing, and mechanical testing. TCPAs are formed from linear low‐density polyethylene monofilament. Linear low‐density polyethylene (LLDPE) TCPAs generate larger stresses than biological muscle through the entire spectrum of strains—contracting more than 40%, exerting more than 0.3 MPa at rest length, and withstanding tension of 8 MPa without damage. Thus, the LLDPE TCPAs attain biological muscle performance statically, but additional tests are required to assess this dynamically. The mechanical performance of LLDPE TCPAs enables biomimetic actuation with an intelligent control and measurement system. Their high‐throughput textile manufacturability positions them for advanced biomechatronic applications—including prosthetics and exoskeletons.
- 2 September 2024
- Published by Wiley in Advanced Intelligent Systems
- Vol. 7 (2)
Open AccessCoil Formation and Biomimetic Performance Characterization of Twisted Coiled Polymer Artificial Muscles
A biological muscle's force is nonlinearly constrained by its current state (force, length, and speed) and state history. To investigate if artificial muscles can mimic (i.e. biomimetic) the complete mechanical state spectrum of biological muscles, this study uses a novel method to characterize twisted coiled polymer actuators (TCPAs) mechanically. Thus, comprehensive and reproducible test procedures are established to verify artificial muscle biomimetics regarding stress, strain, and strain rate combinations intrinsic to biological muscle. A rheometer performs novel high‐precision mechanical characterization methods to comprehensively verify biomimetic performance. Sample twist level, torque, length, force, and temperature are controlled and measured during twist‐induced coiling, heatsetting/annealing, and mechanical testing. TCPAs are formed from linear low‐density polyethylene monofilament. Linear low‐density polyethylene (LLDPE) TCPAs generate larger stresses than biological muscle through the entire spectrum of strains—contracting more than 40%, exerting more than 0.3 MPa at rest length, and withstanding tension of 8 MPa without damage. Thus, the LLDPE TCPAs attain biological muscle performance statically, but additional tests are required to assess this dynamically. The mechanical performance of LLDPE TCPAs enables biomimetic actuation with an intelligent control and measurement system. Their high‐throughput textile manufacturability positions them for advanced biomechatronic applications—including prosthetics and exoskeletons.
- Open Access
Mechanism for the Magnetorheological Effect of Nanocomposite Hydrogels with Magnetite Microparticles
In a previous study, we presented an empirical law for the magnetorheological effect of nanocomposite hydrogels with magnetite microparticles derived from rheological data. In order to understand the underlying processes, we employ computed tomography for structure analysis. This allows the evaluation of the translational and rotational movement of the magnetic particles. Gels with 10% and 3.0% magnetic particle mass content are investigated at three degrees of swelling and at different magnetic flux densities in steady states by means of computed tomography. Since a temperature-controlled sample-chamber is difficult to implement in a tomographic setup, salt is used to deswell the gels instead. Based on the findings of the particle movement, we propose a mechanism using an energy-based approach. This leads to a theoretical law that shows the same scaling behavior as the previously found empirical law.
Open AccessMechanism for the Magnetorheological Effect of Nanocomposite Hydrogels with Magnetite Microparticles
In a previous study, we presented an empirical law for the magnetorheological effect of nanocomposite hydrogels with magnetite microparticles derived from rheological data. In order to understand the underlying processes, we employ computed tomography for structure analysis. This allows the evaluation of the translational and rotational movement of the magnetic particles. Gels with 10% and 3.0% magnetic particle mass content are investigated at three degrees of swelling and at different magnetic flux densities in steady states by means of computed tomography. Since a temperature-controlled sample-chamber is difficult to implement in a tomographic setup, salt is used to deswell the gels instead. Based on the findings of the particle movement, we propose a mechanism using an energy-based approach. This leads to a theoretical law that shows the same scaling behavior as the previously found empirical law.
- Open Access
Empirical Law for the Magnetorheological Effect of Nanocomposite Hydrogels with Magnetite Microparticles
Hydrogels are functional smart materials which can be tailored by modifying their chemical composition. Further functionalization can be achieved by incorporating magnetic particles into the gel matrix. In this study, a hydrogel with magnetite micro-particles is synthesized and characterized by rheological measurements. Inorganic clay is used as the crosslinking agent, which additionally prevents the sedimentation of the micro-particles during the synthesis of the gel. The mass fractions for the magnetite particles in the synthesized gels range from 10% to 60% in the initial state. Rheological measurements are performed in different degrees of swelling using temperature as a stimulus. The influence of a homogeneous magnetic field is analyzed by a step-wise activation and deactivation during dynamic mechanical analysis. For the evaluation of the magnetorheological effect in the steady states a procedure is developed, which takes occurring drift effects into account. Using the magnetic flux density, the particle volume fraction and the storage modulus as independent parameters, a general product approach is deployed for a regression analysis of the dataset. In the end, an empirical law for the magnetorheological effect in nanocomposite hydrogels can be found.
Open AccessEmpirical Law for the Magnetorheological Effect of Nanocomposite Hydrogels with Magnetite Microparticles
Hydrogels are functional smart materials which can be tailored by modifying their chemical composition. Further functionalization can be achieved by incorporating magnetic particles into the gel matrix. In this study, a hydrogel with magnetite micro-particles is synthesized and characterized by rheological measurements. Inorganic clay is used as the crosslinking agent, which additionally prevents the sedimentation of the micro-particles during the synthesis of the gel. The mass fractions for the magnetite particles in the synthesized gels range from 10% to 60% in the initial state. Rheological measurements are performed in different degrees of swelling using temperature as a stimulus. The influence of a homogeneous magnetic field is analyzed by a step-wise activation and deactivation during dynamic mechanical analysis. For the evaluation of the magnetorheological effect in the steady states a procedure is developed, which takes occurring drift effects into account. Using the magnetic flux density, the particle volume fraction and the storage modulus as independent parameters, a general product approach is deployed for a regression analysis of the dataset. In the end, an empirical law for the magnetorheological effect in nanocomposite hydrogels can be found.