Thomas J. Matula
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Thomas J. Matula has a total of 91 co-authors. Here are the top co-authors by number of shared publications:
Keith Chan
Vantage Radiology and Diagnostic Services, Renton, WA, USA
5 shared publicationsAdam D. Maxwell
Department of Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, WA, USA
4 shared publications- Andrew A. Brayman
Ctr. for Industrial and Medical Ultrasound, Appl. Phys. Lab., Univ. of Washington, Seattle, WA
4 shared publications Yak-Nam Wang
Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, Seattle, WA, USA
4 shared publications- Yak-Nam Wang
Ctr. for Industrial and Medical Ultrasound, Appl. Phys. Lab., Univ. of Washington, Seattle, WA
4 shared publications - Brian MacConaghy
University of Washington
3 shared publications
Latest Publications
- 9 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (12: Breaki) , 1868-1878
Histotripsy-Induced Bactericidal Activity Correlates to Size of Cavitation Cloud In Vitro
Large abscesses are walled-off collections of pus and bacteria that often do not respond to antibiotic therapy. Standard of care involves percutaneous placement of indwelling catheter(s) for drainage, a long and uncomfortable process with high rehospitalization rates. The long-term goal of this work is to develop therapeutic ultrasound approaches to eradicate bacteria within abscesses as a noninvasive therapeutic alternative. Inertial cavitation induced by short pulses of focused ultrasound (histotripsy) is known to generate lethal mechanical damage in bacteria. Prior studies with Escherichia coli (E. coli) in suspension demonstrated that bactericidal effects increase with increasing peak negative amplitude, treatment time and duty cycle. The current study investigated correlates of bactericidal activity with histotripsy cavitation cloud size. Histotripsy was applied to E. coli suspensions in 10-mL sample vials at 810 kHz, 1.2 MHz, or 3.25 MHz for 40 minutes. The cavitation activity in the sample vials was separately observed with high-speed photography. The cavitation cloud area was quantified from those images. A linear relationship was observed between bacterial inactivation and cavitation cloud size (R 2 = 0.96), regardless of the acoustic parameters (specifically frequency, pulse duration and power) used to produce the cloud.
- 9 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (12: Breaki) , 1868-1878
Histotripsy-Induced Bactericidal Activity Correlates to Size of Cavitation Cloud In Vitro
Large abscesses are walled-off collections of pus and bacteria that often do not respond to antibiotic therapy. Standard of care involves percutaneous placement of indwelling catheter(s) for drainage, a long and uncomfortable process with high rehospitalization rates. The long-term goal of this work is to develop therapeutic ultrasound approaches to eradicate bacteria within abscesses as a noninvasive therapeutic alternative. Inertial cavitation induced by short pulses of focused ultrasound (histotripsy) is known to generate lethal mechanical damage in bacteria. Prior studies with Escherichia coli (E. coli) in suspension demonstrated that bactericidal effects increase with increasing peak negative amplitude, treatment time and duty cycle. The current study investigated correlates of bactericidal activity with histotripsy cavitation cloud size. Histotripsy was applied to E. coli suspensions in 10-mL sample vials at 810 kHz, 1.2 MHz, or 3.25 MHz for 40 minutes. The cavitation activity in the sample vials was separately observed with high-speed photography. The cavitation cloud area was quantified from those images. A linear relationship was observed between bacterial inactivation and cavitation cloud size (R 2 = 0.96), regardless of the acoustic parameters (specifically frequency, pulse duration and power) used to produce the cloud.
- Open Access
- 18 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Histotripsy-induced bactericidal activity correlates to size of cavitation cloud in vitro
Large abscesses are walled-off collections of pus and bacteria that often do not respond to antibiotic therapy. Standard of care involves percutaneous placement of indwelling catheter(s) for drainage, a long and uncomfortable process with high rehospitalization rates. The long-term goal of this work is to develop therapeutic ultrasound approaches to eradicate bacteria within abscesses as a noninvasive therapeutic alternative. Inertial cavitation induced by short pulses of focused ultrasound (histotripsy) is known to generate lethal mechanical damage in bacteria. Prior studies with Escherichia coli (E. coli) in suspension demonstrated that bactericidal effects increase with increasing peak negative pressure amplitude, treatment time and duty cycle. The current study investigated correlates of bactericidal activity with histotripsy bubble cloud size produced for these treatment parameters at several ultrasound frequencies. Histotripsy was applied to E. coli suspensions in 10-mL sample vials at 810 kHz, 1.2 MHz, or 3.25 MHz for 40 minutes. The resulting cavitation activity in the sample vials was separately observed with high-speed photography. The bubble cloud area was quantified from those images. A linear relationship was observed between log kill and cavitation cloud size (R2 = 0.96), regardless of the acoustic parameters (specifically frequency, pulse duration and pressure amplitude) used to produce the cloud. These findings suggest a role for in-situ treatment monitoring using B-mode imaging.
- 18 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessHistotripsy-induced bactericidal activity correlates to size of cavitation cloud in vitro
Large abscesses are walled-off collections of pus and bacteria that often do not respond to antibiotic therapy. Standard of care involves percutaneous placement of indwelling catheter(s) for drainage, a long and uncomfortable process with high rehospitalization rates. The long-term goal of this work is to develop therapeutic ultrasound approaches to eradicate bacteria within abscesses as a noninvasive therapeutic alternative. Inertial cavitation induced by short pulses of focused ultrasound (histotripsy) is known to generate lethal mechanical damage in bacteria. Prior studies with Escherichia coli (E. coli) in suspension demonstrated that bactericidal effects increase with increasing peak negative pressure amplitude, treatment time and duty cycle. The current study investigated correlates of bactericidal activity with histotripsy bubble cloud size produced for these treatment parameters at several ultrasound frequencies. Histotripsy was applied to E. coli suspensions in 10-mL sample vials at 810 kHz, 1.2 MHz, or 3.25 MHz for 40 minutes. The resulting cavitation activity in the sample vials was separately observed with high-speed photography. The bubble cloud area was quantified from those images. A linear relationship was observed between log kill and cavitation cloud size (R2 = 0.96), regardless of the acoustic parameters (specifically frequency, pulse duration and pressure amplitude) used to produce the cloud. These findings suggest a role for in-situ treatment monitoring using B-mode imaging.
- Open Access
- 1 October 2023
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 154 (4_suppleme) , A52
High throughput system for preparing samples for genomic, epigenetic, transcriptomic, proteomic and metabolomic analysis
Multi-omics considers the analysis of complex biological “omes” (genome, epigenome, transcriptome, proteome, metabolome, and others). This exponentially growing systems biology approach aims to better understand phenotypes in health and disease and as such identify biomarkers of disease and drug targets. The basic workflow is divided into an upstream sample preparation step, and corresponding downstream assays. To prepare samples for these assays biospecimen are treated to extract analytes such as chromatin, DNA, RNA, protein and metabolites. Often these sample preparation steps are done using cavitation. Current tools such as ultrasonic horns, and even many commercial sample preparation instruments, can be highly inconsistent, leading to unreliable assays. In order to overcome the problems of inconsistency, an instrument was designed and built with a transducer array (free field pressures P + = 30 MPa, P– = 12 MPa) capable of processing samples directly in standard 96-well microplates. An array of transducers is mounted below a microplate, coupled to a lens array that focuses acoustic energy into each well of a microplate. Intense cavitation is generated in each well. This process results in consistent analytes extraction that leads to consistently reproducible results. The authors have a financial conflict of interest. [Funded by NIH R33CA191135, R21GM111439, R01DK103849, R42HG010855, U01CA246503, and R44GM122097.]
- 1 October 2023
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 154 (4_suppleme) , A52
Open AccessHigh throughput system for preparing samples for genomic, epigenetic, transcriptomic, proteomic and metabolomic analysis
Multi-omics considers the analysis of complex biological “omes” (genome, epigenome, transcriptome, proteome, metabolome, and others). This exponentially growing systems biology approach aims to better understand phenotypes in health and disease and as such identify biomarkers of disease and drug targets. The basic workflow is divided into an upstream sample preparation step, and corresponding downstream assays. To prepare samples for these assays biospecimen are treated to extract analytes such as chromatin, DNA, RNA, protein and metabolites. Often these sample preparation steps are done using cavitation. Current tools such as ultrasonic horns, and even many commercial sample preparation instruments, can be highly inconsistent, leading to unreliable assays. In order to overcome the problems of inconsistency, an instrument was designed and built with a transducer array (free field pressures P + = 30 MPa, P– = 12 MPa) capable of processing samples directly in standard 96-well microplates. An array of transducers is mounted below a microplate, coupled to a lens array that focuses acoustic energy into each well of a microplate. Intense cavitation is generated in each well. This process results in consistent analytes extraction that leads to consistently reproducible results. The authors have a financial conflict of interest. [Funded by NIH R33CA191135, R21GM111439, R01DK103849, R42HG010855, U01CA246503, and R44GM122097.]
- 15 September 2023
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 49 (12) , 2451-2458
Comparative Study of Histotripsy Pulse Parameters Used to Inactivate Escherichia coli in Suspension
- 15 September 2023
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 49 (12) , 2451-2458
Comparative Study of Histotripsy Pulse Parameters Used to Inactivate Escherichia coli in Suspension
- Open Access
- 1 January 2023
- Published by Acoustical Society of America (ASA) in Proceedings of Meetings on Acoustics
- Vol. 52 (1) , 020001
Inactivation of bacteria using histotripsy: A step toward the treatment of abscesses
Abscesses are walled-off collections of pus and bacteria that commonly require invasive treatments. Abdominal abscesses in particular rank among the top disease Abscesses are walled-off collections of pus and bacteria that commonly require invasive treatments. Abdominal abscesses in particular rank among the top disease
- 1 January 2023
- Published by Acoustical Society of America (ASA) in Proceedings of Meetings on Acoustics
- Vol. 52 (1) , 020001
Open AccessInactivation of bacteria using histotripsy: A step toward the treatment of abscesses
Abscesses are walled-off collections of pus and bacteria that commonly require invasive treatments. Abdominal abscesses in particular rank among the top disease Abscesses are walled-off collections of pus and bacteria that commonly require invasive treatments. Abdominal abscesses in particular rank among the top disease
- 1 March 2021
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 47 (3) , 603-619
Treating Porcine Abscesses with Histotripsy: A Pilot Study
- 1 March 2021
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 47 (3) , 603-619
Treating Porcine Abscesses with Histotripsy: A Pilot Study
- Open Access
Treating Porcine Abscesses With Histotripsy: A Pilot Study
Infected abscesses are walled-off collections of pus and bacteria. They are a common sequela of complications in the setting of surgery, trauma, systemic infections, and other disease states. Current treatment is typically limited to antibiotics with long-term catheter drainage, or surgical wash-out when inaccessible to percutaneous drainage or unresponsive to initial care efforts. Antibiotic resistance is also a growing concern. Although bacteria can develop drug resistance, they remain susceptible to thermal and mechanical damage. In particular, short pulses of focused ultrasound ( i . e ., histotripsy) generate mechanical damage through localized cavitation, representing a potential new paradigm for treating abscesses non-invasively, without the need for long-term catheterization and antibiotics. In this pilot study, boiling and cavitation histotripsy treatments were applied to subcutaneous and intramuscular abscesses developed in a novel porcine model. Ultrasound imaging was used to evaluate abscess maturity, for treatment monitoring and assessment of post-treatment outcomes. Disinfection was quantified by counting bacteria colonies from samples aspirated before and after treatment. Histopathological evaluation of the abscesses was performed to identify changes resulting from histotripsy treatment and potential collateral damage. Cavitation histotripsy was more successful in reducing the bacterial load while having a smaller treatment volume compared with boiling histotripsy. The results of this pilot study suggest focused ultrasound may lead to a technology for in situ treatment of acoustically accessible abscesses.
Open AccessTreating Porcine Abscesses With Histotripsy: A Pilot Study
Infected abscesses are walled-off collections of pus and bacteria. They are a common sequela of complications in the setting of surgery, trauma, systemic infections, and other disease states. Current treatment is typically limited to antibiotics with long-term catheter drainage, or surgical wash-out when inaccessible to percutaneous drainage or unresponsive to initial care efforts. Antibiotic resistance is also a growing concern. Although bacteria can develop drug resistance, they remain susceptible to thermal and mechanical damage. In particular, short pulses of focused ultrasound ( i . e ., histotripsy) generate mechanical damage through localized cavitation, representing a potential new paradigm for treating abscesses non-invasively, without the need for long-term catheterization and antibiotics. In this pilot study, boiling and cavitation histotripsy treatments were applied to subcutaneous and intramuscular abscesses developed in a novel porcine model. Ultrasound imaging was used to evaluate abscess maturity, for treatment monitoring and assessment of post-treatment outcomes. Disinfection was quantified by counting bacteria colonies from samples aspirated before and after treatment. Histopathological evaluation of the abscesses was performed to identify changes resulting from histotripsy treatment and potential collateral damage. Cavitation histotripsy was more successful in reducing the bacterial load while having a smaller treatment volume compared with boiling histotripsy. The results of this pilot study suggest focused ultrasound may lead to a technology for in situ treatment of acoustically accessible abscesses.
- 1 September 2018
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 144 (3) , 1750
Feasibility of using ultrasound with microbubbles to purify cell lines for immunotherapy application
Cell-based immunotherapies exploit cell surface antigens to identify and purify cell lines. Fluorescence-based sorters require large sample volumes and are too costly for small labs. Magnetic sorters require enzymatic digestion to remove magnetic particles. We propose to label cells with antibody-conjugated microbubbles (MBs) and selectively sort them using ultrasound. After sorting, the MBs can be removed by a small overpressure. TargeStar-SA microbubbles (MBs) were conjugated to leukemia cells expressing CD7 antigens. Conjugated cell suspensions were placed in a flow with erythrocytes (which lack CD7) and imaged under magnification. Cell motion was quantified with or without ultrasound insonation. The acoustic radiation force (ARF) acting on a cell-MB pair was modeled by assuming the driving force is associated with the MB, and the viscous drag is due to the larger cell. A separate observation of cell-MB rotation caused by the ARF was explained by considering the torque on the cell, where adherent MBs act as point forces. Under insonation, tagged cells were observed to rotate to align with the ARF, and to move in the direction of the ARF. If a tagged cell was adherent to the coverslip, it only rotated. The model for rotation-only behavior fit well with the data. Under flow, tagged leukemia cells were deflected by ultrasound, while erythrocytes were unaffected. These initial studies suggest a new way for isolating and sorting cells. [Funded by LSDF #3292512, RBBR 17-02-00261, NIH P01 DK43881, and NSBRI via NASA NCC 9-58.]
- 1 September 2018
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 144 (3) , 1750
Feasibility of using ultrasound with microbubbles to purify cell lines for immunotherapy application
Cell-based immunotherapies exploit cell surface antigens to identify and purify cell lines. Fluorescence-based sorters require large sample volumes and are too costly for small labs. Magnetic sorters require enzymatic digestion to remove magnetic particles. We propose to label cells with antibody-conjugated microbubbles (MBs) and selectively sort them using ultrasound. After sorting, the MBs can be removed by a small overpressure. TargeStar-SA microbubbles (MBs) were conjugated to leukemia cells expressing CD7 antigens. Conjugated cell suspensions were placed in a flow with erythrocytes (which lack CD7) and imaged under magnification. Cell motion was quantified with or without ultrasound insonation. The acoustic radiation force (ARF) acting on a cell-MB pair was modeled by assuming the driving force is associated with the MB, and the viscous drag is due to the larger cell. A separate observation of cell-MB rotation caused by the ARF was explained by considering the torque on the cell, where adherent MBs act as point forces. Under insonation, tagged cells were observed to rotate to align with the ARF, and to move in the direction of the ARF. If a tagged cell was adherent to the coverslip, it only rotated. The model for rotation-only behavior fit well with the data. Under flow, tagged leukemia cells were deflected by ultrasound, while erythrocytes were unaffected. These initial studies suggest a new way for isolating and sorting cells. [Funded by LSDF #3292512, RBBR 17-02-00261, NIH P01 DK43881, and NSBRI via NASA NCC 9-58.]
- 1 January 2017
- Published by Acoustical Society of America (ASA) in Proceedings of Meetings on Acoustics
- Vol. 32 (1) , 020009
Inactivation of Planktonic Escherichia coli by High Intensity Focused Ultrasound pulses
This study was motivated by the desire to develop HIFU-based abscess treatments and addresses inactivation of E. coli in volumes up to 10 mL. Cells were treated with 1-MHz nonlinear pulsed HIFU (10 cycles, 2 kHz repetition frequency, +65/−12.8 MPa focal pressures, up to 65 MPa shock fronts). Surviving fraction [SF] was assessed by coliform assay demonstrating curvilinear inactivation kinetics. Reduction of SF to 50% required 2.5 or 6 min in 5 or 10 ml samples, respectively. On light microscopy, surviving cells from 5 min exposures appeared normal, with minimal debris; after 20 min, debris dominated. TEM images of insonated samples showed some undamaged cells, a few damaged but largely intact cells, and comminuted debris. Cellular damage associated with substantive but incomplete levels of inactivation can be subtle. This study demonstrates the feasibility of using pulsed HIFU for partial disinfection of liquid volumes.
- 1 January 2017
- Published by Acoustical Society of America (ASA) in Proceedings of Meetings on Acoustics
- Vol. 32 (1) , 020009
Inactivation of Planktonic Escherichia coli by High Intensity Focused Ultrasound pulses
This study was motivated by the desire to develop HIFU-based abscess treatments and addresses inactivation of E. coli in volumes up to 10 mL. Cells were treated with 1-MHz nonlinear pulsed HIFU (10 cycles, 2 kHz repetition frequency, +65/−12.8 MPa focal pressures, up to 65 MPa shock fronts). Surviving fraction [SF] was assessed by coliform assay demonstrating curvilinear inactivation kinetics. Reduction of SF to 50% required 2.5 or 6 min in 5 or 10 ml samples, respectively. On light microscopy, surviving cells from 5 min exposures appeared normal, with minimal debris; after 20 min, debris dominated. TEM images of insonated samples showed some undamaged cells, a few damaged but largely intact cells, and comminuted debris. Cellular damage associated with substantive but incomplete levels of inactivation can be subtle. This study demonstrates the feasibility of using pulsed HIFU for partial disinfection of liquid volumes.