Yosuke Sugioka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yosuke Sugioka has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Kazuyuki Nakakita
3 shared publicationsShunsuke Koike
Japan Aerospace Exploration Agency, Chofu, Japan
2 shared publicationsTsutomu Nakajima
2 shared publicationsKazunori Mitsuo
宇宙航空研究開発機構 航空技術部
1 shared publication- Kazuyuki Nakakita
Aviation Technology Directorate, Japan Aerospace Exploration Agency, Chofu 182-8522, Japan
1 shared publication Keisuke Asai
Department of Aerospace Engineering, Tohoku University, Sendai, Japan
1 shared publication
Latest Publications
- 20 November 2023
- Published by Springer Nature in Experiments in Fluids
- Vol. 64 (12) , 1-15
Density measurement of supersonic airflow using decay characteristics of FLEET emission
- 20 November 2023
- Published by Springer Nature in Experiments in Fluids
- Vol. 64 (12) , 1-15
Density measurement of supersonic airflow using decay characteristics of FLEET emission
- 29 September 2023
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (1) , 015203
Lifetime based pressure and temperature sensitive paint measurement on a civil aircraft wing under conditions near the onset of shock-induced separation
Lifetime-based pressure- and temperature-sensitive paint (PSP and TSP) measurements were conducted in a large-scale industrial transonic wind tunnel to obtain high-quality pressure data for validation of computational fluid dynamics (CFD) simulations. A wind tunnel test was performed using the NASA common research model in the JAXA 2 m × 2 m transonic wind tunnel. The freestream Mach number was varied in the range of 0.70–0.89, and aerodynamic forces and moments were acquired in order to obtain the pitch break condition related to the onset of shock-induced separation. Polymer-based PSP was coated on a main wing of the model, and TSP was used in tandem with PSP to correct the temperature dependence of PSP. The two-gate lifetime-based method was applied to obtain the PSP and TSP emissions. An a-priori/in-situ hybrid calibration was conducted to convert ratio-of-ratios to pressure, and measured pressure distributions were mapped onto a three-dimensional (3D) model grid. The root-mean-square error for the pressure measurements was evaluated by pressure tap data and was approximated to be 0.8 kPa for all Mach numbers tested. The obtained pressure distributions exhibited a significantly high signal-to-noise ratio and were used for comparison with CFD results on a 3D grid. The high-spatial-resolution PSP measurements helped to accurately localize the differences from the CFD simulation results and showed that the prediction of the shock location along the main wing is still a relevant challenge.
- 29 September 2023
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (1) , 015203
Lifetime based pressure and temperature sensitive paint measurement on a civil aircraft wing under conditions near the onset of shock-induced separation
Lifetime-based pressure- and temperature-sensitive paint (PSP and TSP) measurements were conducted in a large-scale industrial transonic wind tunnel to obtain high-quality pressure data for validation of computational fluid dynamics (CFD) simulations. A wind tunnel test was performed using the NASA common research model in the JAXA 2 m × 2 m transonic wind tunnel. The freestream Mach number was varied in the range of 0.70–0.89, and aerodynamic forces and moments were acquired in order to obtain the pitch break condition related to the onset of shock-induced separation. Polymer-based PSP was coated on a main wing of the model, and TSP was used in tandem with PSP to correct the temperature dependence of PSP. The two-gate lifetime-based method was applied to obtain the PSP and TSP emissions. An a-priori/in-situ hybrid calibration was conducted to convert ratio-of-ratios to pressure, and measured pressure distributions were mapped onto a three-dimensional (3D) model grid. The root-mean-square error for the pressure measurements was evaluated by pressure tap data and was approximated to be 0.8 kPa for all Mach numbers tested. The obtained pressure distributions exhibited a significantly high signal-to-noise ratio and were used for comparison with CFD results on a 3D grid. The high-spatial-resolution PSP measurements helped to accurately localize the differences from the CFD simulation results and showed that the prediction of the shock location along the main wing is still a relevant challenge.
- 12 August 2022
- Published by Springer Nature in Experiments in Fluids
- Vol. 63 (8) , 1-18
Experimental comparison of shock buffet on unswept and 10-deg swept wings
- 12 August 2022
- Published by Springer Nature in Experiments in Fluids
- Vol. 63 (8) , 1-18
Experimental comparison of shock buffet on unswept and 10-deg swept wings
- Open Access
- 1 January 2022
- Published by The Visualization Society of Japan in Journal of the Visualization Society of Japan
- Vol. 42 (165) , 9-12
JAXAにおける感圧塗料技術の研究開発
宇宙航空研究開発機構 (JAXA) 航空技術部門 (旧 航空技術研究所) では,感圧塗料技術の黎明期である1990年代から基礎研究を開始し,欧米に比肩する技術を蓄積してきた.それらは航空宇宙機の開発試験に利用される風洞 (実用風洞) で行われる計測に適用され,実機開発において空力設計や数値シミュレーション (CFD) 結果の妥当性検証に多大な貢献をしている.さらに,JAXAのPSP技術は学術研究においても流体現象の解明や流体制御デバイスの開発に活用されている.本稿では,JAXA航空技術部門の実用風洞におけるPSP開発の展開を簡単に述べ,研究開発対象がどのように推移してきたかを紹介する.さらに,航空宇宙機産業において最先端のPSP技術の適用することで発展が期待されている2つの分野:空力騒音および飛行試験について最新の計測例を示す.
- 1 January 2022
- Published by The Visualization Society of Japan in Journal of the Visualization Society of Japan
- Vol. 42 (165) , 9-12
Open AccessJAXAにおける感圧塗料技術の研究開発
宇宙航空研究開発機構 (JAXA) 航空技術部門 (旧 航空技術研究所) では,感圧塗料技術の黎明期である1990年代から基礎研究を開始し,欧米に比肩する技術を蓄積してきた.それらは航空宇宙機の開発試験に利用される風洞 (実用風洞) で行われる計測に適用され,実機開発において空力設計や数値シミュレーション (CFD) 結果の妥当性検証に多大な貢献をしている.さらに,JAXAのPSP技術は学術研究においても流体現象の解明や流体制御デバイスの開発に活用されている.本稿では,JAXA航空技術部門の実用風洞におけるPSP開発の展開を簡単に述べ,研究開発対象がどのように推移してきたかを紹介する.さらに,航空宇宙機産業において最先端のPSP技術の適用することで発展が期待されている2つの分野:空力騒音および飛行試験について最新の計測例を示す.
- Open Access
Investigation of Factors Causing Nonuniformity in Luminescence Lifetime of Fast-Responding Pressure-Sensitive Paints
Factors that cause nonuniformity in the luminescence lifetime of pressure-sensitive paints (PSPs) were investigated. The lifetime imaging method of PSP does not theoretically require wind-off reference images. Therefore, it can improve measurement accuracy because it can eliminate errors caused by the deformation or movement of the model during the measurement. However, it is reported that the luminescence lifetime of PSP is not uniform on the model, even under uniform conditions of pressure and temperature. Therefore, reference images are used to compensate for the nonuniformity of the luminescence lifetime, which significantly diminishes the advantages of the lifetime imaging method. In particular, fast-responding PSPs show considerable variation in luminescence lifetime compared to conventional polymer-based PSPs. Therefore, this study investigated and discussed the factors causing the nonuniformity of the luminescence lifetime, such as the luminophore solvent, luminophore concentrations, binder thickness, and spraying conditions. The results obtained suggest that the nonuniformity of the luminophore distribution in the binder caused by the various factors mentioned above during the coating process is closely related to the nonuniformity of the luminescence lifetime. For example, when the thickness of the binder became thinner than 8 μm, the fast-responding PSPs showed a tendency to vary significantly in the luminescence lifetime. In addition, it was found that the luminescence lifetime of fast-responding PSP could be changed in the depth direction of the binder depending on the coating conditions. Therefore, it is important to distribute the luminophore uniformly in the binder layer to create PSPs with a more uniform luminescence lifetime distribution.
Open AccessInvestigation of Factors Causing Nonuniformity in Luminescence Lifetime of Fast-Responding Pressure-Sensitive Paints
Factors that cause nonuniformity in the luminescence lifetime of pressure-sensitive paints (PSPs) were investigated. The lifetime imaging method of PSP does not theoretically require wind-off reference images. Therefore, it can improve measurement accuracy because it can eliminate errors caused by the deformation or movement of the model during the measurement. However, it is reported that the luminescence lifetime of PSP is not uniform on the model, even under uniform conditions of pressure and temperature. Therefore, reference images are used to compensate for the nonuniformity of the luminescence lifetime, which significantly diminishes the advantages of the lifetime imaging method. In particular, fast-responding PSPs show considerable variation in luminescence lifetime compared to conventional polymer-based PSPs. Therefore, this study investigated and discussed the factors causing the nonuniformity of the luminescence lifetime, such as the luminophore solvent, luminophore concentrations, binder thickness, and spraying conditions. The results obtained suggest that the nonuniformity of the luminophore distribution in the binder caused by the various factors mentioned above during the coating process is closely related to the nonuniformity of the luminescence lifetime. For example, when the thickness of the binder became thinner than 8 μm, the fast-responding PSPs showed a tendency to vary significantly in the luminescence lifetime. In addition, it was found that the luminescence lifetime of fast-responding PSP could be changed in the depth direction of the binder depending on the coating conditions. Therefore, it is important to distribute the luminophore uniformly in the binder layer to create PSPs with a more uniform luminescence lifetime distribution.
- 8 January 2021
- Published by Springer Nature in Experiments in Fluids
- Vol. 62 (1) , 1-18
Characteristic unsteady pressure field on a civil aircraft wing related to the onset of transonic buffet
- 8 January 2021
- Published by Springer Nature in Experiments in Fluids
- Vol. 62 (1) , 1-18
Characteristic unsteady pressure field on a civil aircraft wing related to the onset of transonic buffet
- Open Access
Characteristic Evaluation of Chameleon Luminophore Dispersed in Polymer
A temperature-sensitive paint (TSP) using a chameleon luminophore is proposed. The chameleon luminophore was dispersed in isobutyl methacrylate polymer in a toluene solvent to fix it on a sample coupon. Temperature and pressure sensitivities of the chameleon luminophore-based TSP were measured using a spectrofluorophotometer. The emission for each wavelength was confirmed to be dependent on the temperature and pressure. The temperature and pressure sensitivities of the TSP were 0.81–2.8%/K and 0.08–0.12%/kPa, respectively. Higher temperature sensitivity can be obtained using the ratio of emissions from the two lanthanide ions, and . The temperature sensitivity when using the ratio of the emission intensities at 616 nm derived from and at 545 nm derived from was 3.2%/K, which was the highest value in the present study. In addition, the pressure sensitivity for the case using the ratio of the emission intensities at 616 and 545 nm was /kPa. Higher temperature sensitivity and lower pressure sensitivity than that with a single wavelength can be achieved using the ratio of the emission intensities at the two peak wavelengths derived from and .Open AccessCharacteristic Evaluation of Chameleon Luminophore Dispersed in Polymer
A temperature-sensitive paint (TSP) using a chameleon luminophore is proposed. The chameleon luminophore was dispersed in isobutyl methacrylate polymer in a toluene solvent to fix it on a sample coupon. Temperature and pressure sensitivities of the chameleon luminophore-based TSP were measured using a spectrofluorophotometer. The emission for each wavelength was confirmed to be dependent on the temperature and pressure. The temperature and pressure sensitivities of the TSP were 0.81–2.8%/K and 0.08–0.12%/kPa, respectively. Higher temperature sensitivity can be obtained using the ratio of emissions from the two lanthanide ions, and . The temperature sensitivity when using the ratio of the emission intensities at 616 nm derived from and at 545 nm derived from was 3.2%/K, which was the highest value in the present study. In addition, the pressure sensitivity for the case using the ratio of the emission intensities at 616 and 545 nm was /kPa. Higher temperature sensitivity and lower pressure sensitivity than that with a single wavelength can be achieved using the ratio of the emission intensities at the two peak wavelengths derived from and .