Anoop Pakkattil
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Anoop Pakkattil has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Ravi Varma
Department of Physics, National Institute of Technology Calicut, Kozhikode, India
5 shared publications - Aiswarya Saseendran
Department of Physics, National Institute of Technology Calicut, Calicut, India
4 shared publications - Claudio Mazzoleni
Michigan Technological University
3 shared publications - Jun Chen
School of Energy and Power Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China P. R
2 shared publications - Ramachandran Arun
School of Energy and Power Engineering, University of Shanghai for Science and Technology, Shanghai, P. R. China
2 shared publications - Shebin John
Department of Physics, National Institute of Technology Calicut, Calicut, India
2 shared publications
Latest Publications
- 16 February 2026
- Published by American Chemical Society (ACS) in ACS ES&T Air
- Vol. 3 (4) , 1069-1078
Quantifying the Contribution of Stubble Burning to Glyoxal over Northwest India
- 16 February 2026
- Published by American Chemical Society (ACS) in ACS ES&T Air
- Vol. 3 (4) , 1069-1078
Quantifying the Contribution of Stubble Burning to Glyoxal over Northwest India
- 16 August 2025
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Atmospheres
- Vol. 130 (16)
Wintertime Intercomparison of Specific Humidity and Temperature Profiles Measured by Microwave Radiometer (MWR), Radiosonde, and INSAT‐3DR Sounder Over Delhi, India
Accurate profiling of atmospheric temperature and humidity is critical for weather forecasting, climate studies, and air quality management. This study evaluates wintertime atmospheric profiles of temperature and specific humidity (SH) from three systems over New Delhi, India: radiosondes, a ground‐based microwave radiometer (MWR), and the INSAT‐3DR satellite sounder. Radiosondes serve as the reference standard, offering high vertical resolution but limited temporal coverage. The MWR provides continuous high‐temporal‐resolution observations with good performance in the lower troposphere, while INSAT‐3DR delivers broad spatial coverage and hourly retrievals but with coarser vertical resolution near the surface and reduced accuracy under cloudy conditions. The comparison reveals that MWR profiles agree well with radiosonde observations below 4 km, with root mean square error values of <4 K for temperature and <2.2 g/kg for SH. However, MWR retrievals exhibit near‐surface cold and dry biases of up to −5 K and −1.2 g/kg (∼−25%), respectively. INSAT‐3DR shows good agreement for temperature throughout the levels (bias of <2%). In the 4–10 km altitude range, SH biases are within ∼25%, but show warm and moist biases near the surface exceeding 2 K and 1 g/kg (30%). These results confirm the complementary nature of MWR and INSAT‐3DR: MWR performs best in the boundary layer, while INSAT‐3DR is more reliable in the mid to top troposphere. The study underscores the importance of combining multiple observation platforms to enhance the accuracy of atmospheric profiling for improved numerical weather prediction and environmental modeling.
- 16 August 2025
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Atmospheres
- Vol. 130 (16)
Wintertime Intercomparison of Specific Humidity and Temperature Profiles Measured by Microwave Radiometer (MWR), Radiosonde, and INSAT‐3DR Sounder Over Delhi, India
Accurate profiling of atmospheric temperature and humidity is critical for weather forecasting, climate studies, and air quality management. This study evaluates wintertime atmospheric profiles of temperature and specific humidity (SH) from three systems over New Delhi, India: radiosondes, a ground‐based microwave radiometer (MWR), and the INSAT‐3DR satellite sounder. Radiosondes serve as the reference standard, offering high vertical resolution but limited temporal coverage. The MWR provides continuous high‐temporal‐resolution observations with good performance in the lower troposphere, while INSAT‐3DR delivers broad spatial coverage and hourly retrievals but with coarser vertical resolution near the surface and reduced accuracy under cloudy conditions. The comparison reveals that MWR profiles agree well with radiosonde observations below 4 km, with root mean square error values of <4 K for temperature and <2.2 g/kg for SH. However, MWR retrievals exhibit near‐surface cold and dry biases of up to −5 K and −1.2 g/kg (∼−25%), respectively. INSAT‐3DR shows good agreement for temperature throughout the levels (bias of <2%). In the 4–10 km altitude range, SH biases are within ∼25%, but show warm and moist biases near the surface exceeding 2 K and 1 g/kg (30%). These results confirm the complementary nature of MWR and INSAT‐3DR: MWR performs best in the boundary layer, while INSAT‐3DR is more reliable in the mid to top troposphere. The study underscores the importance of combining multiple observation platforms to enhance the accuracy of atmospheric profiling for improved numerical weather prediction and environmental modeling.
- 10 April 2025
- Published by Elsevier in Atmospheric Environment
- Vol. 353
Tropospheric ozone precursors over the Indian region: Insights into the shift toward a highly NOx-limited regime
- 10 April 2025
- Published by Elsevier in Atmospheric Environment
- Vol. 353
Tropospheric ozone precursors over the Indian region: Insights into the shift toward a highly NOx-limited regime
- 22 January 2022
- Published by Springer Nature in Aerosol Science and Engineering
- Vol. 6 (1) , 111-125
Retrieval of Broadband Optical Properties from Ambient Aerosols Measurements Using Inverse Mie Calculations
- 22 January 2022
- Published by Springer Nature in Aerosol Science and Engineering
- Vol. 6 (1) , 111-125
Retrieval of Broadband Optical Properties from Ambient Aerosols Measurements Using Inverse Mie Calculations
- 1 January 2022
- Published by Optica Publishing Group
- p. JW2A.15
A UV-Broadband Cavity-Enhanced spectrometer for the sensitive monitoring of BTEX in ambient air
A UV-IBBCEAS spectrometer to measure the BTEX compounds in the ambient air was developed and characterized. The instrument achieved a detection limit of <5 ppb for a measurement time of 60s. This spectrometer was used to study the emissions from an urban environment, where an elevated level of BTEX was observed near to a gas station.
- 1 January 2022
- Published by Optica Publishing Group
- p. JW2A.15
A UV-Broadband Cavity-Enhanced spectrometer for the sensitive monitoring of BTEX in ambient air
A UV-IBBCEAS spectrometer to measure the BTEX compounds in the ambient air was developed and characterized. The instrument achieved a detection limit of <5 ppb for a measurement time of 60s. This spectrometer was used to study the emissions from an urban environment, where an elevated level of BTEX was observed near to a gas station.
- 24 November 2021
- Published by Springer Nature in Air Quality, Atmosphere & Health
- Vol. 15 (3) , 515-520
Glyoxal in a nocturnal atmosphere measured by incoherent broadband cavity-enhanced absorption spectroscopy
- 24 November 2021
- Published by Springer Nature in Air Quality, Atmosphere & Health
- Vol. 15 (3) , 515-520
Glyoxal in a nocturnal atmosphere measured by incoherent broadband cavity-enhanced absorption spectroscopy
- 13 July 2021
- Published by Taylor & Francis in Aerosol Science and Technology
- Vol. 55 (11) , 1264-1276
A broadband cavity-enhanced spectrometer for atmospheric aerosol light extinction measurements
Broadband optical cavity spectroscopy is considered as a technology for trace gas detection; however, recently this has been used for the retrieval of extinction coefficients of aerosols. In this study, we introduce an Incoherent Broadband Cavity Enhanced Extinction spectrometer (IBBCEES), spanning a spectral range from 400–550 nm, which was used to measure the broadband extinction coefficient of ambient aerosols and its temporal variations. Experiments were carried out as a part of an atmospheric field measurements campaign in Yangtze River Delta conducted during summer of 2019 in Changzhou, Jiangsu province, P. R. China. The size distributions and wavelength dependent absorption coefficients of aerosols were measured using a scanning mobility particle sizer (SMPS) and an absorption spectrometer (Aethalometer-AE33), respectively. During the study, it was observed that the temporal variations of measured broadband extinction coefficients and absorption coefficients exhibited a similar trend with the aerosol number density, measured by the SMPS. The spectral dependent single scattering albedo (SSA) derived using the measured extinction and absorption coefficients favorably compares with co-located Cavity Attenuated Phase Shift-ALBedo monitor (CAPS-ALB) operating at 530 nm. The IBBCEES is a simple, sensitive, and robust instrument that can be used to measure the light extinction coefficient of atmospheric aerosols with an estimated net accuracy of ∼6.7% and a 3σ precision of ∼15 Mm−1. The net uncertainties estimated on the reported AAE, EAE and SSA values are ∼3.1%, ∼4.1% and ∼11%, respectively. Copyright © 2021 American Association for Aerosol Research
- 13 July 2021
- Published by Taylor & Francis in Aerosol Science and Technology
- Vol. 55 (11) , 1264-1276
A broadband cavity-enhanced spectrometer for atmospheric aerosol light extinction measurements
Broadband optical cavity spectroscopy is considered as a technology for trace gas detection; however, recently this has been used for the retrieval of extinction coefficients of aerosols. In this study, we introduce an Incoherent Broadband Cavity Enhanced Extinction spectrometer (IBBCEES), spanning a spectral range from 400–550 nm, which was used to measure the broadband extinction coefficient of ambient aerosols and its temporal variations. Experiments were carried out as a part of an atmospheric field measurements campaign in Yangtze River Delta conducted during summer of 2019 in Changzhou, Jiangsu province, P. R. China. The size distributions and wavelength dependent absorption coefficients of aerosols were measured using a scanning mobility particle sizer (SMPS) and an absorption spectrometer (Aethalometer-AE33), respectively. During the study, it was observed that the temporal variations of measured broadband extinction coefficients and absorption coefficients exhibited a similar trend with the aerosol number density, measured by the SMPS. The spectral dependent single scattering albedo (SSA) derived using the measured extinction and absorption coefficients favorably compares with co-located Cavity Attenuated Phase Shift-ALBedo monitor (CAPS-ALB) operating at 530 nm. The IBBCEES is a simple, sensitive, and robust instrument that can be used to measure the light extinction coefficient of atmospheric aerosols with an estimated net accuracy of ∼6.7% and a 3σ precision of ∼15 Mm−1. The net uncertainties estimated on the reported AAE, EAE and SSA values are ∼3.1%, ∼4.1% and ∼11%, respectively. Copyright © 2021 American Association for Aerosol Research
- 26 May 2020
- Published by Taylor & Francis in Aerosol Science and Technology
- Vol. 54 (10) , 1183-1196
Dual-cavity spectrometer for monitoring broadband light extinction by atmospheric aerosols
Atmospheric Aerosols affect Earth’s climate directly by scattering and absorbing solar radiation. In order to study the optical properties of aerosols, we developed a broadband cavity-enhanced spectrometer that uses a supercontinuum laser source and a compact spectrometer, to measure simultaneously the extinction coefficient of aerosols over a broad wavelength region from 420-540 nm. The system employs a dual cavity approach with a reference and a sample cavity, accounting for changes in gases background and for laser spectral and intensity fluctuations. We tested the system with aerosolized salt particles and polystyrene latex spheres. We performed calculations using Mie theory and found good agreement with the measured extinction. We also found that the extinction coefficient of non-absorbing aerosol favorably compares with the scattering coefficient measured by a nephelometer. Finally, we generated soot particles and found an extinction Ångström exponent in good agreement with values reported in the literature. Wavelength dependent detection limits (1σ) for the instrument at 5 nm wavelength resolution and for an integration time of ∼10 minutes were found to be in the range ∼5 Mm−1 – 13 Mm−1. The broadband dual-cavity extinction spectrometer is simple and robust and might be particularly useful for laboratory measurements of the extinction coefficient of brown carbon aerosol. The laboratory tests suggest that the prototype is promising for future developments of a field-deployable instrument.
- 26 May 2020
- Published by Taylor & Francis in Aerosol Science and Technology
- Vol. 54 (10) , 1183-1196
Dual-cavity spectrometer for monitoring broadband light extinction by atmospheric aerosols
Atmospheric Aerosols affect Earth’s climate directly by scattering and absorbing solar radiation. In order to study the optical properties of aerosols, we developed a broadband cavity-enhanced spectrometer that uses a supercontinuum laser source and a compact spectrometer, to measure simultaneously the extinction coefficient of aerosols over a broad wavelength region from 420-540 nm. The system employs a dual cavity approach with a reference and a sample cavity, accounting for changes in gases background and for laser spectral and intensity fluctuations. We tested the system with aerosolized salt particles and polystyrene latex spheres. We performed calculations using Mie theory and found good agreement with the measured extinction. We also found that the extinction coefficient of non-absorbing aerosol favorably compares with the scattering coefficient measured by a nephelometer. Finally, we generated soot particles and found an extinction Ångström exponent in good agreement with values reported in the literature. Wavelength dependent detection limits (1σ) for the instrument at 5 nm wavelength resolution and for an integration time of ∼10 minutes were found to be in the range ∼5 Mm−1 – 13 Mm−1. The broadband dual-cavity extinction spectrometer is simple and robust and might be particularly useful for laboratory measurements of the extinction coefficient of brown carbon aerosol. The laboratory tests suggest that the prototype is promising for future developments of a field-deployable instrument.
- Open Access
- 28 January 2019
- Published by Copernicus GmbH in EGUsphere
- p. 1-15
Observation of nocturnal NO3 during vehicular activities in the medium sized city of Calicut in coastal India
Nitrate radical (NO3) is the most important nocturnal oxidant in urban atmosphere. The city of Calicut (Kozhikode) is a medium sized urban location in India. One of the bus terminals at Palayam part of the city [11.2495° N, 75.7842° E] is adjacent to the vegetable sorting facilities cum market, both of which have intense activities by buses and trucks from about 3 AM till about 8 PM on all working days. We report preliminary measurements observing NO3 on five nights during a weeklong measurement campaign in the autumn of 2018. Measurements were made between 10 PM and 6 AM, and focus was when diesel vehicles were found idling along about half a km stretch during 3–6 AM while the loading/unloading of vegetables at sorting facility happens. Incoherent Broadband Cavity Enhanced Absorption Spectroscopic technique in open-path configuration (OP-IBBCEAS) was employed for measurements. The instrument was installed 8.5 m above the ground level over the east wing of Palayam bus terminal building adjacent to the vegetable market. The 285 cm long optical resonator was arranged on a custom-made aluminium profile platform 1 m high. The stability of the instrument for the entire period of measurement was excellent, and high NO3 mixing ratios with levels exceeding several hundred pptv were observed during early morning hours when heavy vehicles were idling. The highest NO3 mixing ratio observed was (497 ± 140) pptv during one of the nights. The fit uncertainty, which was considered as the uncertainty in retrieved concentration, was found to increase with increased aerosol loading. The uncertainty for a spectral averaging interval of 10 min was recorded as ~20 pptv and ~100 pptv during the lowest and the highest aerosol loading events respectively.
- 28 January 2019
- Published by Copernicus GmbH in EGUsphere
- p. 1-15
Open AccessObservation of nocturnal NO3 during vehicular activities in the medium sized city of Calicut in coastal India
Nitrate radical (NO3) is the most important nocturnal oxidant in urban atmosphere. The city of Calicut (Kozhikode) is a medium sized urban location in India. One of the bus terminals at Palayam part of the city [11.2495° N, 75.7842° E] is adjacent to the vegetable sorting facilities cum market, both of which have intense activities by buses and trucks from about 3 AM till about 8 PM on all working days. We report preliminary measurements observing NO3 on five nights during a weeklong measurement campaign in the autumn of 2018. Measurements were made between 10 PM and 6 AM, and focus was when diesel vehicles were found idling along about half a km stretch during 3–6 AM while the loading/unloading of vegetables at sorting facility happens. Incoherent Broadband Cavity Enhanced Absorption Spectroscopic technique in open-path configuration (OP-IBBCEAS) was employed for measurements. The instrument was installed 8.5 m above the ground level over the east wing of Palayam bus terminal building adjacent to the vegetable market. The 285 cm long optical resonator was arranged on a custom-made aluminium profile platform 1 m high. The stability of the instrument for the entire period of measurement was excellent, and high NO3 mixing ratios with levels exceeding several hundred pptv were observed during early morning hours when heavy vehicles were idling. The highest NO3 mixing ratio observed was (497 ± 140) pptv during one of the nights. The fit uncertainty, which was considered as the uncertainty in retrieved concentration, was found to increase with increased aerosol loading. The uncertainty for a spectral averaging interval of 10 min was recorded as ~20 pptv and ~100 pptv during the lowest and the highest aerosol loading events respectively.