Tzu-Sheng Shen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tzu-Sheng Shen has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Masato Hasegawa
Department of Mechanical Engineering, National Institute of Technology, Ishikawa College, Kitachujo, Tsubata 9290392, Ishikawa, Japan
4 shared publications - Miho Seike
Graduate School of Advanced Science and Engineering, Transdisciplinary Science and Engineering Program, Hiroshima University, 1-5-1 Kagamiyama, Higashi-Hiroshima 7398529, Hiroshima, Japan
4 shared publications - Nobuyoshi Kawabata
Faculty of Production Systems Engineering and Sciences, Komatsu University, Nu 1-3, Shicho-machi, Komatsu 9238511, Ishikawa, Japan
4 shared publications - Shen-Wen Chien
Department of Fire Science, Central Police University, Taoyuan City 33304, Taiwan
4 shared publications - Hung-Chieh Chung
Kaohsiung City Fire Bureau
3 shared publications - Cheng-Chung Cheng
Division of Mechanical Science and Engineering, Graduate School of Natural Science and Technology, Kanazawa University, Kakumamachi, Kanazawa 9201164, Japan
1 shared publication
Latest Publications
- Open Access
Assessment Method Integrating Visibility and Toxic Gas for Road Tunnel Fires Using 2D Maps for Identifying Risks in the Smoke Environment
This study proposes an assessment method to quantify the risks of the smoke environment for road tunnel fire safety based on previous studies. The assessment method integrates visibility and toxic gases to address the hazards of smoke distribution more comprehensively. Considering that the hazards of visibility reduction and toxic gases for tunnel users vary with exposure time and location in a fire event, the smoke environment (SE) levels are defined as a function of longitudinal location and time. The SE levels simplify smoke distribution as calculated from 3D computational fluid dynamics (CFDs). For easily identifying SE risks, SE levels are illustrated on a 2D map to analyze the potential hazard by quantifying specific areas and times of smoke exposure. To demonstrate the applicability of the assessment method of this study, cases are carried out using CFD simulation to investigate the risks associated with tunnel fires with various tunnel cross-section types, longitudinal velocities, and gradients. In the analysis of the SE level in different cross-section types and longitudinal velocities under the condition of no vehicle, a velocity of 0.9–1.1 m/s can maintain a less serious SE level both upstream and downstream in a horizontal rectangular tunnel, and 0.3–0.5 m/s in a horizontal horseshoe-shaped tunnel. Both rectangular and horseshoe-shaped tunnels reveal an obvious rise within 10–15 min. In the case of inclined tunnels, for both rectangular and horseshoe-shaped tunnels, the SE level near the fire source obviously deteriorates. Thus, the longitudinal velocity range for the purpose of maintaining a relatively less serious SE level should be slightly reduced for inclined tunnels compared with horizontal tunnels.
Open AccessAssessment Method Integrating Visibility and Toxic Gas for Road Tunnel Fires Using 2D Maps for Identifying Risks in the Smoke Environment
This study proposes an assessment method to quantify the risks of the smoke environment for road tunnel fire safety based on previous studies. The assessment method integrates visibility and toxic gases to address the hazards of smoke distribution more comprehensively. Considering that the hazards of visibility reduction and toxic gases for tunnel users vary with exposure time and location in a fire event, the smoke environment (SE) levels are defined as a function of longitudinal location and time. The SE levels simplify smoke distribution as calculated from 3D computational fluid dynamics (CFDs). For easily identifying SE risks, SE levels are illustrated on a 2D map to analyze the potential hazard by quantifying specific areas and times of smoke exposure. To demonstrate the applicability of the assessment method of this study, cases are carried out using CFD simulation to investigate the risks associated with tunnel fires with various tunnel cross-section types, longitudinal velocities, and gradients. In the analysis of the SE level in different cross-section types and longitudinal velocities under the condition of no vehicle, a velocity of 0.9–1.1 m/s can maintain a less serious SE level both upstream and downstream in a horizontal rectangular tunnel, and 0.3–0.5 m/s in a horizontal horseshoe-shaped tunnel. Both rectangular and horseshoe-shaped tunnels reveal an obvious rise within 10–15 min. In the case of inclined tunnels, for both rectangular and horseshoe-shaped tunnels, the SE level near the fire source obviously deteriorates. Thus, the longitudinal velocity range for the purpose of maintaining a relatively less serious SE level should be slightly reduced for inclined tunnels compared with horizontal tunnels.
- Open Access
Numerical Study of Smoke Distribution in Inclined Tunnel Fire Ventilation Modes Considering Traffic Conditions
Japan and Europe have adopted significantly different ventilation modes with regard to traffic conditions (with or without congestion). This study focuses on the smoke behavior of different ventilation modes by conducting a 3D CFD analysis of smoke distribution and CO concentration variation and then comparing these modes based on two groups (relatively low target velocity: 0 and 1 m/s; relatively high target velocity: 2 and 3 m/s). The considered fire size is 30 MW for four longitudinal gradients (0, 2, 4, and 6%). In the simulation results, velocities of both 0 and 1 m/s reveal good performance in maintaining the stratification of smoke and ensuring the safety of the environment in 10 min in the occurrence of traffic jams. However, in 15 min, the smoke conditions change. Thus, it is difficult to distinguish which ventilation mode (0 and 1 m/s) shows relatively better performance during traffic congestion. When traffic is uncongested, the comparison of Um = 2 and 3 m/s reveals that a target velocity of Um = 2 m/s (lower than critical velocity) can also prevent the risk of smoke on the upstream side because no descending phenomenon is observed. Moreover, Um = 2 m/s causes the relatively slow propagation of descending smoke, increasing the possibility of evacuation once a second traffic incident occurs on the downstream side of the fire source.
Open AccessNumerical Study of Smoke Distribution in Inclined Tunnel Fire Ventilation Modes Considering Traffic Conditions
Japan and Europe have adopted significantly different ventilation modes with regard to traffic conditions (with or without congestion). This study focuses on the smoke behavior of different ventilation modes by conducting a 3D CFD analysis of smoke distribution and CO concentration variation and then comparing these modes based on two groups (relatively low target velocity: 0 and 1 m/s; relatively high target velocity: 2 and 3 m/s). The considered fire size is 30 MW for four longitudinal gradients (0, 2, 4, and 6%). In the simulation results, velocities of both 0 and 1 m/s reveal good performance in maintaining the stratification of smoke and ensuring the safety of the environment in 10 min in the occurrence of traffic jams. However, in 15 min, the smoke conditions change. Thus, it is difficult to distinguish which ventilation mode (0 and 1 m/s) shows relatively better performance during traffic congestion. When traffic is uncongested, the comparison of Um = 2 and 3 m/s reveals that a target velocity of Um = 2 m/s (lower than critical velocity) can also prevent the risk of smoke on the upstream side because no descending phenomenon is observed. Moreover, Um = 2 m/s causes the relatively slow propagation of descending smoke, increasing the possibility of evacuation once a second traffic incident occurs on the downstream side of the fire source.
- Open Access
- 8 December 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (24) , 12580
Walking Speed in a Motorbike Lane Considering the Density of Evacuees and Motorbikes
In countries with a high motorbike utilization rate, road tunnels can feature motorbike lanes, bringing an additional risk to evacuation from tunnels during a fire or emergency. To better understand the walking speed in motorbike lanes to enhance risk assessment in tunnels, in the present study, we conducted evacuation experiments to investigate the influence of motorbike and evacuee density on the walking speed of motorbike users. According to the experimental results, the walking speed was slightly reduced even when the evacuee density was relatively lower (around 0.1 person/m2). To further analyze the influence of motorbikes in the lane, the walking speed decreased significantly with the increase in motorbike density. The decrease in walking speed presented an exponential relationship with evacuee and motorbike density. Considering this exponential relationship, nonlinear regression was applied to estimate the parameters of the walking speed model. The proposed model consisting of the evacuee density, motorbike density, and free walking speed as variables can serve as an approach to describe the walking speed of motorbike lane evacuation in tunnels.
- 8 December 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (24) , 12580
Open AccessWalking Speed in a Motorbike Lane Considering the Density of Evacuees and Motorbikes
In countries with a high motorbike utilization rate, road tunnels can feature motorbike lanes, bringing an additional risk to evacuation from tunnels during a fire or emergency. To better understand the walking speed in motorbike lanes to enhance risk assessment in tunnels, in the present study, we conducted evacuation experiments to investigate the influence of motorbike and evacuee density on the walking speed of motorbike users. According to the experimental results, the walking speed was slightly reduced even when the evacuee density was relatively lower (around 0.1 person/m2). To further analyze the influence of motorbikes in the lane, the walking speed decreased significantly with the increase in motorbike density. The decrease in walking speed presented an exponential relationship with evacuee and motorbike density. Considering this exponential relationship, nonlinear regression was applied to estimate the parameters of the walking speed model. The proposed model consisting of the evacuee density, motorbike density, and free walking speed as variables can serve as an approach to describe the walking speed of motorbike lane evacuation in tunnels.
- Open Access
Scale Model Experiments and Simulations to Investigate the Effect of Vehicular Blockage on Backlayering Length in Tunnel Fire
This study used model experiments and numerical simulations to investigate the backlayering length of a vehicle-blocked tunnel fire. The experimental setup included two types of obstacles (low obstacles and high obstacles), as well as three configurations: no obstacles, one side with a car obstacle, and two sides with a car obstacle. If there were vehicles on one side of a lane, it would have little effect on the elongation of the backlayer length. When there were vehicles on both sides of a lane, the elongation of the backlayer length was greatly reduced. In addition, the effects of the vehicular blockage ratio and blockage configuration on the properties of the backlayering length were investigated. We created Pattern A, where fire is was in the center, and Pattern B, where fire was on the side of the tunnel. In Pattern A, almost all obstacles could be approximated using the formula. When the vehicle blockage ratio of a single lane was small, an approximation formula for Pattern B was applicable. However, if the distance between stationary vehicles on the upstream side of the fire source was small, the backlayering length could have been longer than in the case with no vehicular blockage.
Open AccessScale Model Experiments and Simulations to Investigate the Effect of Vehicular Blockage on Backlayering Length in Tunnel Fire
This study used model experiments and numerical simulations to investigate the backlayering length of a vehicle-blocked tunnel fire. The experimental setup included two types of obstacles (low obstacles and high obstacles), as well as three configurations: no obstacles, one side with a car obstacle, and two sides with a car obstacle. If there were vehicles on one side of a lane, it would have little effect on the elongation of the backlayer length. When there were vehicles on both sides of a lane, the elongation of the backlayer length was greatly reduced. In addition, the effects of the vehicular blockage ratio and blockage configuration on the properties of the backlayering length were investigated. We created Pattern A, where fire is was in the center, and Pattern B, where fire was on the side of the tunnel. In Pattern A, almost all obstacles could be approximated using the formula. When the vehicle blockage ratio of a single lane was small, an approximation formula for Pattern B was applicable. However, if the distance between stationary vehicles on the upstream side of the fire source was small, the backlayering length could have been longer than in the case with no vehicular blockage.
- Open Access
- 10 November 2021
- Published by MDPI AG in Sustainability
- Vol. 13 (22) , 12421
An Article on Green Firefighting Equipment in Taiwan
This paper discusses the relationship between green buildings and fire safety from a higher perspective including the traditional fire factors, fire resilience, sustainable building SAFR, social, ecological, and economic fields. There is no need to sacrifice fire safety in the name of sustainability. There is no direct report of fire incidents with green design elements. However, indirectly from the characteristics of residents, green buildings have a high degree of intersection with vulnerable groups, which directly affects the life safety of green building fires. The gray water recycling design of sustainable buildings (green buildings) combined with a simple waterway-connected sprinkler system will be an excellent cooperation example between green (Green Design) and red (Fire Safety). Taiwan’s photovoltaic development plan is expected to reach the 500 MW in 2025, which is equivalent to 2.5% of the government’s promotion target of 20 GW. Whether a PV fire occurs during the day or night, photovoltaic modules will generate lethal electricity, which is a potential hazard to first responders and rescue team.
- 10 November 2021
- Published by MDPI AG in Sustainability
- Vol. 13 (22) , 12421
Open AccessAn Article on Green Firefighting Equipment in Taiwan
This paper discusses the relationship between green buildings and fire safety from a higher perspective including the traditional fire factors, fire resilience, sustainable building SAFR, social, ecological, and economic fields. There is no need to sacrifice fire safety in the name of sustainability. There is no direct report of fire incidents with green design elements. However, indirectly from the characteristics of residents, green buildings have a high degree of intersection with vulnerable groups, which directly affects the life safety of green building fires. The gray water recycling design of sustainable buildings (green buildings) combined with a simple waterway-connected sprinkler system will be an excellent cooperation example between green (Green Design) and red (Fire Safety). Taiwan’s photovoltaic development plan is expected to reach the 500 MW in 2025, which is equivalent to 2.5% of the government’s promotion target of 20 GW. Whether a PV fire occurs during the day or night, photovoltaic modules will generate lethal electricity, which is a potential hazard to first responders and rescue team.
- 1 January 2006
- Published by SAGE Publications in Journal of Fire Sciences
- Vol. 24 (1) , 7-25
Building Egress Analysis
This study tries to develop an analysis procedure by which the architecture plans for egress systems can be evaluated and compared at normal condition evacuation or emergency evacuation with static (fixed blockage of selected target spaces, e.g., earthquake, bomb) or dynamic (timed block of target spaces, e.g., fire) blocking. This approach can also be used to compare the evacuation performance of buildings, which includes ones that meet the codes and ones that do not.
- 1 January 2006
- Published by SAGE Publications in Journal of Fire Sciences
- Vol. 24 (1) , 7-25
Building Egress Analysis
This study tries to develop an analysis procedure by which the architecture plans for egress systems can be evaluated and compared at normal condition evacuation or emergency evacuation with static (fixed blockage of selected target spaces, e.g., earthquake, bomb) or dynamic (timed block of target spaces, e.g., fire) blocking. This approach can also be used to compare the evacuation performance of buildings, which includes ones that meet the codes and ones that do not.