Andreas G. Reisinger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Andreas G. Reisinger has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Dieter H. Pahr
Institute of Lightweight Design and Structural Biomechanics, TU Wien, Vienna, Austria
11 shared publications Dieter H. Pahr
5 shared publicationsSarah-Jane Estermann
TU Wien, Institute of Lightweight Design and Structural Biomechanics, Gumpendorfer Straße 7, 1060, Vienna, Austria; Karl Landsteiner University of Health Sciences, Department of Anatomy and Biomechanics, Division Biomechanics, Dr. Karl-Dorrek-Straße 30, 3500, Krems, Austria; Austrian Center for Medical Innovation & Technology (ACMIT), Viktor Kaplan-Straße 2/1, 2700, Wiener Neustadt, Austria
4 shared publications- Lena Hirtler
Center for Anatomy and Cell Biology, Division of Anatomy, Medical University of Vienna, Vienna, Austria
3 shared publications Martin Frank
Karl Landsteiner University of Health Sciences, Department of Anatomy and Biomechanics, Division Biomechanics, Dr. Karl-Dorrek-Straße 30, 3500, Krems, Austria
3 shared publications- Philipp Johannes Thurner
Faculty of Mechanical and Industrial Engineering Institute of Lightweight Design and Structural Biomechanics TU Wien Vienna Austria
3 shared publications
Latest Publications
- Open Access
- 18 March 2026
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 120
How do particle shape and image resolution influence accuracy of single particle tracking
- 18 March 2026
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 120
Open AccessHow do particle shape and image resolution influence accuracy of single particle tracking
- Open Access
- 2 May 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 168, 107043
Predicting osteosynthesis screw failure by peri-implant bone morphology in multiple loading conditions
- 2 May 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 168, 107043
Open AccessPredicting osteosynthesis screw failure by peri-implant bone morphology in multiple loading conditions
- Open Access
- 1 May 2025
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Research
- Vol. 14 (5) , 368-375
Decreased femoral fracture load after cephalomedullary nail removal
Aims: Spontaneous neck fractures are feared complications of cephalomedullary nail removal after successful healing of per- and subtrochanteric fractures. To date, the initial postoperative stability as well as the correct weightbearing regimen remain unclear. The aim of this biomechanical ex vivo study was to evaluate the initial postoperative failure load after hardware removal of specimens, which received cephalomedullary nails during their lifetime.Methods: A total of 20 specimens of voluntary body donors were included in this study. Group 1 (n = 10) consisted of specimens that received cephalomedullary nails during their lifetime due to per- or subtrochanteric fractures. Each individual was matched for age, sex, femur size, and neck-shaft angle (Group 2 = control, n = 10). Biomechanical testing was performed in a single-leg stance setting, and volumetric bone mineral density (vBMD) was measured proximally at the femoral neck and distally at the epicondyles.Results: Groups 1 and 2 differed significantly in terms of failure loads (p = 0.002), fracture types, and ratios of proximal and distal vBMD (p = 0.035). Femora after nail removal were significantly weaker (1,835.0 N vs 4,523.0 N) and showed lower ratios of proximal to distal vBMD (0.74 vs 1.18), which indicated altered stress distributions at the femoral neck in presence of femoral neck screws. They were further characterized by predominantly subcapital buckle-type fractures, while the control Group 2 showed predominantly transcervical fractures.Conclusion: Altered stress distribution in presence of femoral neck screws leads to changes in biomechanical properties of the proximal femur, resulting in potentially unstable situations after nail removal in clinical settings. Elective removal of cephalomedullary nails should be undertaken with caution in view of the potentially increased fracture risk.Cite this article: Bone Joint Res 2025;14(5):365–372.
- 1 May 2025
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Research
- Vol. 14 (5) , 368-375
Open AccessDecreased femoral fracture load after cephalomedullary nail removal
Aims: Spontaneous neck fractures are feared complications of cephalomedullary nail removal after successful healing of per- and subtrochanteric fractures. To date, the initial postoperative stability as well as the correct weightbearing regimen remain unclear. The aim of this biomechanical ex vivo study was to evaluate the initial postoperative failure load after hardware removal of specimens, which received cephalomedullary nails during their lifetime.Methods: A total of 20 specimens of voluntary body donors were included in this study. Group 1 (n = 10) consisted of specimens that received cephalomedullary nails during their lifetime due to per- or subtrochanteric fractures. Each individual was matched for age, sex, femur size, and neck-shaft angle (Group 2 = control, n = 10). Biomechanical testing was performed in a single-leg stance setting, and volumetric bone mineral density (vBMD) was measured proximally at the femoral neck and distally at the epicondyles.Results: Groups 1 and 2 differed significantly in terms of failure loads (p = 0.002), fracture types, and ratios of proximal and distal vBMD (p = 0.035). Femora after nail removal were significantly weaker (1,835.0 N vs 4,523.0 N) and showed lower ratios of proximal to distal vBMD (0.74 vs 1.18), which indicated altered stress distributions at the femoral neck in presence of femoral neck screws. They were further characterized by predominantly subcapital buckle-type fractures, while the control Group 2 showed predominantly transcervical fractures.Conclusion: Altered stress distribution in presence of femoral neck screws leads to changes in biomechanical properties of the proximal femur, resulting in potentially unstable situations after nail removal in clinical settings. Elective removal of cephalomedullary nails should be undertaken with caution in view of the potentially increased fracture risk.Cite this article: Bone Joint Res 2025;14(5):365–372.
- Open Access
- 7 April 2025
- Published by Elsevier in Bioprinting
- Vol. 48
Reproducing viscoelastic properties of soft tissues in 3D printed silicone models by two-phase infill tuning
- 7 April 2025
- Published by Elsevier in Bioprinting
- Vol. 48
Open AccessReproducing viscoelastic properties of soft tissues in 3D printed silicone models by two-phase infill tuning
- Open Access
- 18 November 2023
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 150, 106259
The 2-layer elasto-visco-plastic rheological model for the material parameter identification of bone tissue extended by a damage law
- 18 November 2023
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 150, 106259
Open AccessThe 2-layer elasto-visco-plastic rheological model for the material parameter identification of bone tissue extended by a damage law
- Open Access
- 9 January 2023
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 139, 105664
The predictive ability of a QCT-FE model of the proximal femoral stiffness under multiple load cases is strongly influenced by experimental uncertainties
- 9 January 2023
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 139, 105664
Open AccessThe predictive ability of a QCT-FE model of the proximal femoral stiffness under multiple load cases is strongly influenced by experimental uncertainties
- Open Access
- 1 February 2022
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 126, 104999
A parameter reduced adaptive quasi-linear viscoelastic model for soft biological tissue in uniaxial tension
- 1 February 2022
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 126, 104999
Open AccessA parameter reduced adaptive quasi-linear viscoelastic model for soft biological tissue in uniaxial tension
- Open Access
- 1 February 2022
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 126, 105033
Experimental validation of a micro-CT finite element model of a human cadaveric mandible rehabilitated with short-implant-supported partial dentures
- 1 February 2022
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 126, 105033
Open AccessExperimental validation of a micro-CT finite element model of a human cadaveric mandible rehabilitated with short-implant-supported partial dentures
- Open Access
- 1 January 2022
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 125, 104875
Material design of soft biological tissue replicas using viscoelastic micromechanical modelling
- 1 January 2022
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 125, 104875
Open AccessMaterial design of soft biological tissue replicas using viscoelastic micromechanical modelling
- 24 October 2021
- Published by Elsevier in International Journal of Solids and Structures
- Vol. 236-237, 111295
Numerical and experimental study on the collapse of a triangular cell under compression
- 24 October 2021
- Published by Elsevier in International Journal of Solids and Structures
- Vol. 236-237, 111295
Numerical and experimental study on the collapse of a triangular cell under compression