Huipeng Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Huipeng Zhou has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Cong Yu
State Key Laboratory of Electromagnetically Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, China; School of Applied Chemistry and Engineering, University of Science and Technology of China, Hefei 230026, China
6 shared publications Niu Niu
State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, China
4 shared publicationsChunhua He
Changchun University of Science and Technology
2 shared publicationsEjaz Hussain
State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, P. R. China
2 shared publications- Mian Hasnain Nawaz
Interdisciplinary Research Centre in Biomedical Materials (IRCBM), COMSATS University Islamabad, Lahore, Pakistan
2 shared publications Na Yang
State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, China
2 shared publications
Latest Publications
- 13 October 2020
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 12 (44) , 5353-5359
A perylene monoimide probe based fluorescent micelle sensor for the selective and sensitive detection of picric acid
A hydroxyl functionalized perylene monoimide probe (PMI-OH) was prepared and self-assembled with the nonionic surfactant Triton X-100 (TX100) to fabricate a fluorescent micelle sensor for the selective and sensitive detection of picric acid (PA), a common explosive and environmental pollutant. The synthesized PMI-OH probe exhibited excimer fluorescence emission, and the intensity of the excimer fluorescence emission was significantly enhanced after the PMI-OH probe formed micelles with TX100. The obtained PMI-OH@TX100 micelles presented excellent photoluminescence properties and had a maximum fluorescence emission at 630 nm. The red fluorescence of the PMI-OH@TX100 micelles was quenched upon introduction of the nitro explosive PA due to electron transfer from the donor (PMI-OH) to the acceptor (PA). The fluorescence quenching of the fluorescent micelle sensor was proportional to the concentration of PA in the range of 2 to 10 μM. The limit of detection was 500 nM using 3σ/k. Thus, the developed PMI-OH@TX100 micelle sensor has great potential to detect PA in ordinary samples.
- 13 October 2020
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 12 (44) , 5353-5359
A perylene monoimide probe based fluorescent micelle sensor for the selective and sensitive detection of picric acid
A hydroxyl functionalized perylene monoimide probe (PMI-OH) was prepared and self-assembled with the nonionic surfactant Triton X-100 (TX100) to fabricate a fluorescent micelle sensor for the selective and sensitive detection of picric acid (PA), a common explosive and environmental pollutant. The synthesized PMI-OH probe exhibited excimer fluorescence emission, and the intensity of the excimer fluorescence emission was significantly enhanced after the PMI-OH probe formed micelles with TX100. The obtained PMI-OH@TX100 micelles presented excellent photoluminescence properties and had a maximum fluorescence emission at 630 nm. The red fluorescence of the PMI-OH@TX100 micelles was quenched upon introduction of the nitro explosive PA due to electron transfer from the donor (PMI-OH) to the acceptor (PA). The fluorescence quenching of the fluorescent micelle sensor was proportional to the concentration of PA in the range of 2 to 10 μM. The limit of detection was 500 nM using 3σ/k. Thus, the developed PMI-OH@TX100 micelle sensor has great potential to detect PA in ordinary samples.
- 30 August 2019
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 144 (20) , 6136-6142
The use of aggregation-induced emission probe doped silica nanoparticles for the immunoassay of human epididymis protein 4
A sensitive sandwich immunoassay for the sensing of human epididymis protein 4 (HE4) is developed based on aggregation-induced emission probe doped silica nanoparticles. Fluorescent silica nanoparticles (TSiO2) with excellent performance were prepared using a tetraphenylethylene based probe (TPE-C4-4) to produce a controlled aggregation effect, and HE4 was detected using antibody-functionalized fluorescent silica nanoparticles. The fluorescent silica nanoparticles possess good photophysical properties. The TSiO2 NPs were surface modified with carboxyl groups, and the antibody was covalently attached onto the surface of the nanoparticles. In addition, magnetic beads were modified with N-hydroxysulfosuccinimide sodium salt (NHS) on their surface, capable of forming stable peptide bonds with the antibody. TSiO2 NPs modified by an antibody and the magnetic beads modified by an antibody were used for the sandwich immunoassay for HE4 protein. The assay is quite sensitive and selective. The detection limit of HE4 is estimated to be 40 pM. The assay shows promising applications for the early diagnosis of ovarian cancer and the development of ovarian cancer-related drugs.
- 30 August 2019
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 144 (20) , 6136-6142
The use of aggregation-induced emission probe doped silica nanoparticles for the immunoassay of human epididymis protein 4
A sensitive sandwich immunoassay for the sensing of human epididymis protein 4 (HE4) is developed based on aggregation-induced emission probe doped silica nanoparticles. Fluorescent silica nanoparticles (TSiO2) with excellent performance were prepared using a tetraphenylethylene based probe (TPE-C4-4) to produce a controlled aggregation effect, and HE4 was detected using antibody-functionalized fluorescent silica nanoparticles. The fluorescent silica nanoparticles possess good photophysical properties. The TSiO2 NPs were surface modified with carboxyl groups, and the antibody was covalently attached onto the surface of the nanoparticles. In addition, magnetic beads were modified with N-hydroxysulfosuccinimide sodium salt (NHS) on their surface, capable of forming stable peptide bonds with the antibody. TSiO2 NPs modified by an antibody and the magnetic beads modified by an antibody were used for the sandwich immunoassay for HE4 protein. The assay is quite sensitive and selective. The detection limit of HE4 is estimated to be 40 pM. The assay shows promising applications for the early diagnosis of ovarian cancer and the development of ovarian cancer-related drugs.
- Open Access
- 3 April 2018
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 8 (23) , 12785-12790
A ratiometric fluorescence assay for acetylcholinesterase activity and inhibitor screening based on supramolecular assembly induced monomer–excimer emission transition of a perylene probe
The PDI-DHA can aggregate to form supramolecular assemblies when mixed with lauroylcholine and lauric acid, and is employed as a ratiometric fluorescence probe for the detection of AChE activity.
- 3 April 2018
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 8 (23) , 12785-12790
Open AccessA ratiometric fluorescence assay for acetylcholinesterase activity and inhibitor screening based on supramolecular assembly induced monomer–excimer emission transition of a perylene probe
The PDI-DHA can aggregate to form supramolecular assemblies when mixed with lauroylcholine and lauric acid, and is employed as a ratiometric fluorescence probe for the detection of AChE activity.
- 10 January 2018
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 42 (4) , 2520-2525
A turn-on fluorescent BOPHY probe for Cu2+ ion detection
A novel D–π–A type fluorine–boron compound BOPHY-PTZ was synthesized and employed as a “turn on” fluorescent probe for the sensitive detection of Cu2+ ions.
- 10 January 2018
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 42 (4) , 2520-2525
A turn-on fluorescent BOPHY probe for Cu2+ ion detection
A novel D–π–A type fluorine–boron compound BOPHY-PTZ was synthesized and employed as a “turn on” fluorescent probe for the sensitive detection of Cu2+ ions.
- 6 March 2017
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 5 (32) , 6572-6578
Peroxidase activity of the coronene bisimide supramolecular architecture and its applications in colorimetric sensing of H 2 O 2 and glucose
A new water soluble coronene bisimide derivative (CTDI) was designed and synthesized. CTDI self-assembled in an aqueous solution and formed supramolecular nanofibers through π–π stacking and hydrophobic interactions. The nanofibers exhibit distinct peroxidase-like catalytic activity, and can catalyze the redox reaction of 3,3,5,5-tetramethylbenzidine (TMB) in the presence of hydrogen peroxide. Clear assay solution color changes were observed. The peroxidase-like catalytic property was utilized for the sensitive detection of H2O2 and glucose. The assay shows excellent sensitivity, and 1 μM of glucose could be easily detected. Glucose detection in dilute human blood samples was also demonstrated, and the results were verified using a commercial glucose meter. Our method is simple, convenient, sensitive and selective, and could facilitate the sensing of glucose in relation to biological and biomedical research applications.
- 6 March 2017
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 5 (32) , 6572-6578
Peroxidase activity of the coronene bisimide supramolecular architecture and its applications in colorimetric sensing of H 2 O 2 and glucose
A new water soluble coronene bisimide derivative (CTDI) was designed and synthesized. CTDI self-assembled in an aqueous solution and formed supramolecular nanofibers through π–π stacking and hydrophobic interactions. The nanofibers exhibit distinct peroxidase-like catalytic activity, and can catalyze the redox reaction of 3,3,5,5-tetramethylbenzidine (TMB) in the presence of hydrogen peroxide. Clear assay solution color changes were observed. The peroxidase-like catalytic property was utilized for the sensitive detection of H2O2 and glucose. The assay shows excellent sensitivity, and 1 μM of glucose could be easily detected. Glucose detection in dilute human blood samples was also demonstrated, and the results were verified using a commercial glucose meter. Our method is simple, convenient, sensitive and selective, and could facilitate the sensing of glucose in relation to biological and biomedical research applications.
- 26 January 2017
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 53 (15) , 2398-2401
Specific detection of cancer cells through aggregation-induced emission of a light-up bioprobe
A specific cancer cell detection method through the aggregation-induced emission of a light-up bioprobe is developed.
- 26 January 2017
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 53 (15) , 2398-2401
Specific detection of cancer cells through aggregation-induced emission of a light-up bioprobe
A specific cancer cell detection method through the aggregation-induced emission of a light-up bioprobe is developed.