Victor Khokhlov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Victor Khokhlov has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Jan Meyer
7 shared publications- David de la Vega
Faculty of Engineering, University of the Basque Country, Bilbao, Spain
4 shared publications - Deborah Ritzmann
National Physical Laboratory, UK
4 shared publications - Jan Meyer
Technische Universität Dresden
4 shared publications - Stefano Lodetti
Electromagnetic and Electrochemical Technologies Department, National Physical Laboratory, London, UK
4 shared publications - Alexander Gallarreta
Faculty of Engineering, University of the Basque Country, Bilbao, Spain
3 shared publications
Latest Publications
- Open Access
- 25 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Access Journal of Power and Energy
- Vol. 10, 395-405
Adverse Impact of Harmonic and Interharmonic Supply Voltage Distortion on Mass-Market Electrical Appliances
This article presents the results of the immunity evaluation of mass-market electrical appliances subjected to harmonic and interharmonic distortion of the supply voltage. Therefore, the immunity of twenty selected single-phase electrical appliances is evaluated within a comprehensive framework that considers perceptible malfunctions and long-term adverse impacts. Furthermore, a specially designed test procedure is employed to optimize the characterization of appliances with variable operating states and to ensure the reproducibility of results. In light of that, the feasibility of increasing compatibility levels for harmonics and interharmonics is discussed. The results shall serve as input for the ongoing discussion about appropriate compatibility levels in low voltage networks acceptable to all stakeholders.
- 25 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Access Journal of Power and Energy
- Vol. 10, 395-405
Open AccessAdverse Impact of Harmonic and Interharmonic Supply Voltage Distortion on Mass-Market Electrical Appliances
This article presents the results of the immunity evaluation of mass-market electrical appliances subjected to harmonic and interharmonic distortion of the supply voltage. Therefore, the immunity of twenty selected single-phase electrical appliances is evaluated within a comprehensive framework that considers perceptible malfunctions and long-term adverse impacts. Furthermore, a specially designed test procedure is employed to optimize the characterization of appliances with variable operating states and to ensure the reproducibility of results. In light of that, the feasibility of increasing compatibility levels for harmonics and interharmonics is discussed. The results shall serve as input for the ongoing discussion about appropriate compatibility levels in low voltage networks acceptable to all stakeholders.
- Open Access
- 30 November 2022
- Published by Elsevier in Electric Power Systems Research
- Vol. 216
On the suitability of the CISPR 16 method for measuring conducted emissions in the 2–150kHz range in low voltage grids
- 30 November 2022
- Published by Elsevier in Electric Power Systems Research
- Vol. 216
Open AccessOn the suitability of the CISPR 16 method for measuring conducted emissions in the 2–150kHz range in low voltage grids
- Open Access
- 10 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-10
A Light Measurement Method for 9–150 kHz Disturbances in Power Grids Comparable to CISPR Quasi-Peak
This study proposes a novel measurement method to assess the disturbances in the electrical grid for the CISPR Band A (9–150 kHz), as no normative grid measurement method for these frequencies exists yet. Compatibility levels (CL) in IEC 61000-2-2 in this frequency range are defined based on the CISPR 16-1-1 method using the quasi-peak (QP) detector. However, this method is not directly applicable for grid measurements as it was originally designed for laboratory conditions and for measuring radio disturbances and immunity. The method proposed in this article (Light-QP method) overcomes these limitations, along with lower complexity, computational burden, and memory requirements than CISPR 16-1-1. The Light-QP method uses a digital QP detector that processes root mean square (rms) values of spectral components, calculated by adapting the IEC 61000-4-7 standard to the CISPR Band A. The proposed Light-QP method is applied to real measurements from a low-voltage (LV) distribution grid and compared to the QP outputs from a digital implementation of the CISPR 16-1-1 method. The results are comparable and can be used for assessment against CL. The Light-QP method has been presented to IEC SC77A/WG9 for its potential inclusion as a normative measurement method in a new version of the IEC 61000-4-30 standard.
- 10 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-10
Open AccessA Light Measurement Method for 9–150 kHz Disturbances in Power Grids Comparable to CISPR Quasi-Peak
This study proposes a novel measurement method to assess the disturbances in the electrical grid for the CISPR Band A (9–150 kHz), as no normative grid measurement method for these frequencies exists yet. Compatibility levels (CL) in IEC 61000-2-2 in this frequency range are defined based on the CISPR 16-1-1 method using the quasi-peak (QP) detector. However, this method is not directly applicable for grid measurements as it was originally designed for laboratory conditions and for measuring radio disturbances and immunity. The method proposed in this article (Light-QP method) overcomes these limitations, along with lower complexity, computational burden, and memory requirements than CISPR 16-1-1. The Light-QP method uses a digital QP detector that processes root mean square (rms) values of spectral components, calculated by adapting the IEC 61000-4-7 standard to the CISPR Band A. The proposed Light-QP method is applied to real measurements from a low-voltage (LV) distribution grid and compared to the QP outputs from a digital implementation of the CISPR 16-1-1 method. The results are comparable and can be used for assessment against CL. The Light-QP method has been presented to IEC SC77A/WG9 for its potential inclusion as a normative measurement method in a new version of the IEC 61000-4-30 standard.
- Open Access
- 8 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Measurement of 2-150 kHz Conducted Emissions in Power Networks
A framework for the comparison of measurement methods of conducted emissions in the frequency range 2-150 kHz is presented. In addition to present non-normative methods published by the IEC, alternative approaches in the literature are considered. Furthermore, test signals and key metrics are described. The comparison results will provide a baseline for specification of a new normative method for power grid measurements.
- 8 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessMeasurement of 2-150 kHz Conducted Emissions in Power Networks
A framework for the comparison of measurement methods of conducted emissions in the frequency range 2-150 kHz is presented. In addition to present non-normative methods published by the IEC, alternative approaches in the literature are considered. Furthermore, test signals and key metrics are described. The comparison results will provide a baseline for specification of a new normative method for power grid measurements.
- Open Access
- 19 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-10
Comparison of Measurement Methods for 2–150-kHz Conducted Emissions in Power Networks
This paper presents a comparison of measurement methods for current and voltage distortion in low voltage networks in the frequency range from 2 kHz to 150 kHz (supraharmonics). The comparison encompasses the methods informatively described in IEC and CISPR international standards, as well as other innovative techniques presented in the literature. The presented work is carried out within a novel framework that includes advanced and complex synthetic test signals, as well as real grid recordings, that allow an accurate comparison of the performance of the tested methods. Specifically designed indices are employed to characterize the accuracy of the tested methods in the frequency and amplitude assessment. In light of that, strengths and weaknesses of the methods are identified. The results of this paper contribute to the ongoing standardization work carried out by the IEC SC77A/WG9 with the purpose of defining a normative measurement method suitable for assessing grid disturbance levels in the range from 2 kHz to 150 kHz.
- 19 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-10
Open AccessComparison of Measurement Methods for 2–150-kHz Conducted Emissions in Power Networks
This paper presents a comparison of measurement methods for current and voltage distortion in low voltage networks in the frequency range from 2 kHz to 150 kHz (supraharmonics). The comparison encompasses the methods informatively described in IEC and CISPR international standards, as well as other innovative techniques presented in the literature. The presented work is carried out within a novel framework that includes advanced and complex synthetic test signals, as well as real grid recordings, that allow an accurate comparison of the performance of the tested methods. Specifically designed indices are employed to characterize the accuracy of the tested methods in the frequency and amplitude assessment. In light of that, strengths and weaknesses of the methods are identified. The results of this paper contribute to the ongoing standardization work carried out by the IEC SC77A/WG9 with the purpose of defining a normative measurement method suitable for assessing grid disturbance levels in the range from 2 kHz to 150 kHz.
- 1 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Test Procedure for Determining the Stabilisation Time of Lamps and Other Household Appliances
Proper stabilisation is one important requirement for the measurement of harmonic emission of electrical appliances. A set of modern household appliances is used to study the change of their electrical and thermal parameters after connection to the power source and the time for their entire stabilisation in a laboratory setup. Based on a novel approach, which is more robust and less time-consuming compared to other approaches, the stabilisation process for different types of appliances is determined. The impact of different test conditions, like the mounting orientation or ambient temperature on the stabilisation time is studied. The results suggest that the stabilisation times should be individually determined for a tested device and the applied test conditions has to be carefully selected to adequately reflect reality.
- 1 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Test Procedure for Determining the Stabilisation Time of Lamps and Other Household Appliances
Proper stabilisation is one important requirement for the measurement of harmonic emission of electrical appliances. A set of modern household appliances is used to study the change of their electrical and thermal parameters after connection to the power source and the time for their entire stabilisation in a laboratory setup. Based on a novel approach, which is more robust and less time-consuming compared to other approaches, the stabilisation process for different types of appliances is determined. The impact of different test conditions, like the mounting orientation or ambient temperature on the stabilisation time is studied. The results suggest that the stabilisation times should be individually determined for a tested device and the applied test conditions has to be carefully selected to adequately reflect reality.
- Open Access
- 15 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 77618-77630
Comparison of Measurement Methods for the Frequency Range 2–150 kHz (Supraharmonics) Based on the Present Standards Framework
Advances in power electronics, increasing share of renewables in the energy system and e-mobility cause an increase of disturbances in the frequency range 2-150 kHz, also known as supraharmonics. A rigorous, credible and agreed measurement framework is essential to evaluate electromagnetic compatibility (EMC) in this frequency range. While a normative method exists for measuring equipment emission in the laboratory, no normative method exists yet for the measurement of supraharmonic disturbance levels in the grid. The aim of this research is a detailed comparison of potential measurement methods derived from existing standards IEC 61000-4-7, IEC 61000-4-30, CISPR 16-1-1 and a critical assessment of their suitability for disturbance measurements in grid applications. Based on a comprehensive set of synthetic signals and real measurements from laboratory and field, this article studies the ability of the methods to assess the typical characteristics of supraharmonic emission with relevance to EMC coordination. It presents the benefits and drawbacks of the existing measurement methods and discusses the suitability of possible modifications for grid compliance assessment. The results and recommendations intend to be an input for the present activities of IEC SC 77A WG 9 to define a normative method for the measurement of supraharmonic disturbance levels to be included in the next edition of IEC 61000-4-30.
- 15 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 77618-77630
Open AccessComparison of Measurement Methods for the Frequency Range 2–150 kHz (Supraharmonics) Based on the Present Standards Framework
Advances in power electronics, increasing share of renewables in the energy system and e-mobility cause an increase of disturbances in the frequency range 2-150 kHz, also known as supraharmonics. A rigorous, credible and agreed measurement framework is essential to evaluate electromagnetic compatibility (EMC) in this frequency range. While a normative method exists for measuring equipment emission in the laboratory, no normative method exists yet for the measurement of supraharmonic disturbance levels in the grid. The aim of this research is a detailed comparison of potential measurement methods derived from existing standards IEC 61000-4-7, IEC 61000-4-30, CISPR 16-1-1 and a critical assessment of their suitability for disturbance measurements in grid applications. Based on a comprehensive set of synthetic signals and real measurements from laboratory and field, this article studies the ability of the methods to assess the typical characteristics of supraharmonic emission with relevance to EMC coordination. It presents the benefits and drawbacks of the existing measurement methods and discusses the suitability of possible modifications for grid compliance assessment. The results and recommendations intend to be an input for the present activities of IEC SC 77A WG 9 to define a normative method for the measurement of supraharmonic disturbance levels to be included in the next edition of IEC 61000-4-30.
- 19 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 69 (9) , 6704-6712
A Robust Wavelet-Based Hybrid Method for the Simultaneous Measurement of Harmonic and Supraharmonic Distortion
This paper introduces a new method for the simultaneous measurement of harmonic and supraharmonic distortion with improved robustness against amplitude and power frequency deviations. The proposed algorithm is based on wavelet analysis and it is designed to analyze a detect-all=true10 cycles measurement interval, something crucial when implementing methods to measure harmonic and supraharmonic content according to the IEC 61000-4-7 standard. Discrete Fourier Transform (DFT)-based methods, instead, must analyze a fixed detect-all=true200 interval in order to avoid apparent shifts of the supraharmonic frequency components. The results of the experimental measurements presented in the paper show that the DFT-based methodology suggested in the IEC 61000-4-7 standard produces results affected by the value of the power frequency and amplitude while the proposed method, instead, is insensitive to them. This feature also removes the need of a previous high pass filtering stage, required for the IEC method. Moreover, the proposed method has the additional advantage of working on the same measurement interval to calculate both harmonics and supraharmonics, which reduces the complexity of data handling by avoiding multithreaded Data Acquisition (DAQ) operations.
- 19 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 69 (9) , 6704-6712
A Robust Wavelet-Based Hybrid Method for the Simultaneous Measurement of Harmonic and Supraharmonic Distortion
This paper introduces a new method for the simultaneous measurement of harmonic and supraharmonic distortion with improved robustness against amplitude and power frequency deviations. The proposed algorithm is based on wavelet analysis and it is designed to analyze a detect-all=true10 cycles measurement interval, something crucial when implementing methods to measure harmonic and supraharmonic content according to the IEC 61000-4-7 standard. Discrete Fourier Transform (DFT)-based methods, instead, must analyze a fixed detect-all=true200 interval in order to avoid apparent shifts of the supraharmonic frequency components. The results of the experimental measurements presented in the paper show that the DFT-based methodology suggested in the IEC 61000-4-7 standard produces results affected by the value of the power frequency and amplitude while the proposed method, instead, is insensitive to them. This feature also removes the need of a previous high pass filtering stage, required for the IEC method. Moreover, the proposed method has the additional advantage of working on the same measurement interval to calculate both harmonics and supraharmonics, which reduces the complexity of data handling by avoiding multithreaded Data Acquisition (DAQ) operations.
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A Robust Measurement Method for Supraharmonics Under Power Frequency Deviations
This paper introduces a new measurement method for supraharmonic distortion with improved robustness against power frequency deviations. The proposed method is based on wavelet analysis and it is designed to analyze a 10 cycles measurement interval. Fourier-based methods, instead, must analyze a fixed 200 ms window in order to avoid apparent shifts of the supraharmonic frequency components. The results of the experimental measurements presented in the paper show that the Fourier-based method suggested in IEC 61000-4-7 standard produces results affected by the value of the power frequency. The proposed method, instead, provides results completely independent of the power frequency. This feature also removes the need of a previous high pass filtering stage, required for the IEC method. Moreover, the proposed method has the additional advantage of working on the same measurement interval as traditional harmonics (below 2 kHz), feature that can reduce the complexity of measurement instruments.
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A Robust Measurement Method for Supraharmonics Under Power Frequency Deviations
This paper introduces a new measurement method for supraharmonic distortion with improved robustness against power frequency deviations. The proposed method is based on wavelet analysis and it is designed to analyze a 10 cycles measurement interval. Fourier-based methods, instead, must analyze a fixed 200 ms window in order to avoid apparent shifts of the supraharmonic frequency components. The results of the experimental measurements presented in the paper show that the Fourier-based method suggested in IEC 61000-4-7 standard produces results affected by the value of the power frequency. The proposed method, instead, provides results completely independent of the power frequency. This feature also removes the need of a previous high pass filtering stage, required for the IEC method. Moreover, the proposed method has the additional advantage of working on the same measurement interval as traditional harmonics (below 2 kHz), feature that can reduce the complexity of measurement instruments.
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Thermal Interactions in Modern Lighting Equipment due to Disturbances in the Frequency Range 2–150 kHz
The increasing use of renewables, e-mobility and great demand for energy-efficient devices in the mass-market segment have an impact on Power Quality in the electrical network. In addition to classical harmonic interferences, both the end users and the network operators face the challenge of higher frequency disturbances, which refers to distortion in the frequency range 2–150 kHz, also known as supraharmonics. While malfunctions caused by supraharmonic emission are well documented in the literature, its long-term impact is not well investigated. This paper discusses the long-term effect of supraharmonics on modern lighting equipment and deals with the thermal stress of the aluminum electrolytic capacitor. The aim of research is to clarify the process of additional temperature increase caused by supraharmonic emission. Based on a comprehensive laboratory study the paper gives an overview of different heating mechanisms and identifies relevant impact factors.
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Thermal Interactions in Modern Lighting Equipment due to Disturbances in the Frequency Range 2–150 kHz
The increasing use of renewables, e-mobility and great demand for energy-efficient devices in the mass-market segment have an impact on Power Quality in the electrical network. In addition to classical harmonic interferences, both the end users and the network operators face the challenge of higher frequency disturbances, which refers to distortion in the frequency range 2–150 kHz, also known as supraharmonics. While malfunctions caused by supraharmonic emission are well documented in the literature, its long-term impact is not well investigated. This paper discusses the long-term effect of supraharmonics on modern lighting equipment and deals with the thermal stress of the aluminum electrolytic capacitor. The aim of research is to clarify the process of additional temperature increase caused by supraharmonic emission. Based on a comprehensive laboratory study the paper gives an overview of different heating mechanisms and identifies relevant impact factors.