Jiahao Xie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jiahao Xie has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- A. P. Sakis Meliopoulos
School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, USA
2 shared publications - Chiyang Zhong
School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, USA
2 shared publications - Kaiyu Liu
Eaton Research Lab, Eaton Corporation, Lakewood, CO, USA
2 shared publications A.P. Sakis Meliopoulos
Georgia Institute of Technology, Atlanta, Georgia United States
1 shared publication- Binglin Wang
School of Information Science and Technology, ShanghaiTech University, Shanghai, China
1 shared publication Boqi Xie
School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, USA
1 shared publication
Latest Publications
- 27 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (3) , 5376-5385
A Novel Estimation Based Protection Method of Voltage Source Converters
This paper addresses the critical need for reliable protection of voltage source converters (VSCs), which is essential for grid stability and safety of both the converter and the connected power system. With the advancement of VSC technology, robust fault detection and coordinated protection remain a priority in power system engineering. In this paper, a dynamic state estimation-based protection (EBP) approach is designed to enhance VSC system security. The EBP scheme is set up based on quasi-dynamic domain converter system models and a loss function is incorporated into the converter model to ensure high-fidelity of the model. Phasor measurements are obtained by applying discrete Fourier Transform to the data received from merging units. A static synchronous compensator (STATCOM) serves as the testbed for simulating fault events and validating EBP's performance. The proposed EBP demonstrates high reliability in identifying four types of faults, each with unique characteristics. In conclusion, the EBP provides a promising advancement for reliable and sensitive protection of VSCs in modern power systems.
- 27 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (3) , 5376-5385
A Novel Estimation Based Protection Method of Voltage Source Converters
This paper addresses the critical need for reliable protection of voltage source converters (VSCs), which is essential for grid stability and safety of both the converter and the connected power system. With the advancement of VSC technology, robust fault detection and coordinated protection remain a priority in power system engineering. In this paper, a dynamic state estimation-based protection (EBP) approach is designed to enhance VSC system security. The EBP scheme is set up based on quasi-dynamic domain converter system models and a loss function is incorporated into the converter model to ensure high-fidelity of the model. Phasor measurements are obtained by applying discrete Fourier Transform to the data received from merging units. A static synchronous compensator (STATCOM) serves as the testbed for simulating fault events and validating EBP's performance. The proposed EBP demonstrates high reliability in identifying four types of faults, each with unique characteristics. In conclusion, the EBP provides a promising advancement for reliable and sensitive protection of VSCs in modern power systems.
- Open Access
- 1 April 2022
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2234 (1) , 012001
Multi-sensor target allocation model based on NC-PSO
Traditional multi-sensor target allocation often has problems such as slow algorithm iteration and low solution quality. In response to this problem, this paper proposes the NC-PSO algorithm, so that the particles can jump out of the local optimum and increase the convergence speed. At the same time, on the basis of the improved algorithm, the constraint of the target threat degree is added, the interval analytic hierarchy process is used to estimate the target threat, and the allocation principle is optimized, so that the use of sensor resources is better and the allocation is more reasonable. The simulation results prove that NC-PSO can allocate targets to multiple sensors faster and better.
- 1 April 2022
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2234 (1) , 012001
Open AccessMulti-sensor target allocation model based on NC-PSO
Traditional multi-sensor target allocation often has problems such as slow algorithm iteration and low solution quality. In response to this problem, this paper proposes the NC-PSO algorithm, so that the particles can jump out of the local optimum and increase the convergence speed. At the same time, on the basis of the improved algorithm, the constraint of the target threat degree is added, the interval analytic hierarchy process is used to estimate the target threat, and the allocation principle is optimized, so that the use of sensor resources is better and the allocation is more reasonable. The simulation results prove that NC-PSO can allocate targets to multiple sensors faster and better.
- 27 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (4) , 3082-3096
Multi-Layer Model Enabled Fault Location for Underground Cables in MMC-HVDC Grids Considering Distributed and Frequency Dependent Line Parameters
Accurate fault location for underground cables in MMC-HVDC grids reduces the time finding faults as well as the system operational costs. For MMC-HVDC grids, the data window during faults is usually short. During such severe transients, the frequency dependent line parameters of the underground cables have strong influence on the fault location accuracy. In this paper, a novel fault location algorithm for underground cables in MMC-HVDC grids is proposed. First, a multi-layer model for the underground cable using partial differential equations is proposed, which considers the distributed and frequency dependent line parameters in time domain. Afterwards, the numerical finite difference solution of the multi-layer model is proposed to obtain the voltage distributions along the entire cable. Finally, the voltage method is applied to locate faults. Numerical experiments show that the multi-layer model accurately considers the frequency dependency of the cable parameters, and the solution of the model obtains accurate voltage distribution even during system transient. Extensive test cases prove that the proposed algorithm locates faults with less errors than the existing algorithm. The method is also compatible with a relatively low sampling rate (20 kHz) and a short data window (5 ms).
- 27 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (4) , 3082-3096
Multi-Layer Model Enabled Fault Location for Underground Cables in MMC-HVDC Grids Considering Distributed and Frequency Dependent Line Parameters
Accurate fault location for underground cables in MMC-HVDC grids reduces the time finding faults as well as the system operational costs. For MMC-HVDC grids, the data window during faults is usually short. During such severe transients, the frequency dependent line parameters of the underground cables have strong influence on the fault location accuracy. In this paper, a novel fault location algorithm for underground cables in MMC-HVDC grids is proposed. First, a multi-layer model for the underground cable using partial differential equations is proposed, which considers the distributed and frequency dependent line parameters in time domain. Afterwards, the numerical finite difference solution of the multi-layer model is proposed to obtain the voltage distributions along the entire cable. Finally, the voltage method is applied to locate faults. Numerical experiments show that the multi-layer model accurately considers the frequency dependency of the cable parameters, and the solution of the model obtains accurate voltage distribution even during system transient. Extensive test cases prove that the proposed algorithm locates faults with less errors than the existing algorithm. The method is also compatible with a relatively low sampling rate (20 kHz) and a short data window (5 ms).
- 12 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 12 (4) , 3128-3137
Multi-Stage Quadratic Flexible Optimal Power Flow With a Rolling Horizon
Optimal power flow (OPF) has always played an important role in optimizing the operation of power systems, which are complex and highly nonlinear networks. The need for optimization is even more pressing in modern power grids with distributed energy resources (DERs, with or without storage) that introduce more flexibility, dynamics, and uncertainties to power grids. Most importantly, they add the time dimension to the optimization process: DERs generate the need to optimize systems in real time over a time horizon considering forecasts. This article proposes a multi-stage OPF formulation and solution method based on object-oriented device models with a rolling horizon incorporated for real-time optimizations to achieve optimal feedback control. The process also takes into account changing forecasts. The proposed approach is tested on a real distribution feeder and the results indicate that the method is very promising.
- 12 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 12 (4) , 3128-3137
Multi-Stage Quadratic Flexible Optimal Power Flow With a Rolling Horizon
Optimal power flow (OPF) has always played an important role in optimizing the operation of power systems, which are complex and highly nonlinear networks. The need for optimization is even more pressing in modern power grids with distributed energy resources (DERs, with or without storage) that introduce more flexibility, dynamics, and uncertainties to power grids. Most importantly, they add the time dimension to the optimization process: DERs generate the need to optimize systems in real time over a time horizon considering forecasts. This article proposes a multi-stage OPF formulation and solution method based on object-oriented device models with a rolling horizon incorporated for real-time optimizations to achieve optimal feedback control. The process also takes into account changing forecasts. The proposed approach is tested on a real distribution feeder and the results indicate that the method is very promising.
- 7 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Computer
- Vol. 53 (5) , 63-72
Sensitive Detection of GPS Spoofing Attack in Phasor Measurement Units via Quasi-Dynamic State Estimation
We propose the use of a quasi-dynamic-state estimator to detect GPS spoofing attacks and assist in recovering from attacks on power grids. Numerical results show that this method is sensitive to GPS spoofing attacks with robust performance regardless of measurement noise.
- 7 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Computer
- Vol. 53 (5) , 63-72
Sensitive Detection of GPS Spoofing Attack in Phasor Measurement Units via Quasi-Dynamic State Estimation
We propose the use of a quasi-dynamic-state estimator to detect GPS spoofing attacks and assist in recovering from attacks on power grids. Numerical results show that this method is sensitive to GPS spoofing attacks with robust performance regardless of measurement noise.