Yassmine Rghif
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yassmine Rghif has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Fatima Bahraoui
Team of Heat Transfer and Energetic (UAE/U10FST), Faculty of Sciences and Techniques of Tangier, Abdelmalek Essaâdi University, Morocco
7 shared publicationsBelkacem Zeghmati
4 shared publications- Belkacem Zeghmati
LAboratoire de Modélisation Pluridisciplinaire et Simulations
2 shared publications - Daniele Colarossi
Università Politecnica delle Marche
2 shared publications Abdessamad Nait Brahim
Team of Heat Transfer and Energetic (UAE/U10FST), Faculty of Sciences and Techniques of Tangier, Abdelmalek Essaâdi University, Morocco
1 shared publication- Asaad Hameed Sayer
University of Thi-Qar
1 shared publication
Latest Publications
- Open Access
- 8 March 2024
- Published by Elsevier in Solar Energy Materials and Solar Cells
- Vol. 269
Optimization of the mass ratio and melting temperature of PCMs integrated in Salt Gradient Solar Ponds
- 8 March 2024
- Published by Elsevier in Solar Energy Materials and Solar Cells
- Vol. 269
Open AccessOptimization of the mass ratio and melting temperature of PCMs integrated in Salt Gradient Solar Ponds
- 30 January 2023
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 145 (5) , 1-33
Transient behavior of a salinity gradient solar pond under Mediterranean climate
This paper aims to investigate the transient behavior of a salinity gradient solar pond(SGSP) under Mediterranean climate. For this propose, a 2D numerical model is developed in which the absorption of solar radiation by different layers of saline water, the wind effect at free surface, the heat losses and the development of the double-diffusive convection in the lower and upper convective zones are considered. The governing equations of continuity, momentum, thermal energy and diffusion are solved using the finite volume method with SIMPLE algorithm. The validity of the numerical model developed in Fortran95 is achieved through the comparisons of the results computed with the available numerical and experimental results obtained by literature studies. Results show that the developed numerical model can predict transient behavior of the SGSPs with a good accuracy. As an application of this model, temperature, salt concentration, energy stored and storage efficiency variations of a proposed SGSP are analyzed under Mediterranean climate. The results show that the lower convective zone(LCZ) temperature increases from 15 °C to around 95 °C whereas the temperature of the upper convective zone(UCZ) varies sinusoidally depending on that of the ambient air. Furthermore, the salt concentration of the LCZ decreases from 250kg/m3 to around 248kg/m3 while that of the UCZ increases from50 kg/m3 to about 52kg/m3. Additionally, the thermal energy stored is around 135MJ with an efficiency of about 38% which confirms the capacity of the SGSP to store thermal energy as sensible heat.
- 30 January 2023
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 145 (5) , 1-33
Transient behavior of a salinity gradient solar pond under Mediterranean climate
This paper aims to investigate the transient behavior of a salinity gradient solar pond(SGSP) under Mediterranean climate. For this propose, a 2D numerical model is developed in which the absorption of solar radiation by different layers of saline water, the wind effect at free surface, the heat losses and the development of the double-diffusive convection in the lower and upper convective zones are considered. The governing equations of continuity, momentum, thermal energy and diffusion are solved using the finite volume method with SIMPLE algorithm. The validity of the numerical model developed in Fortran95 is achieved through the comparisons of the results computed with the available numerical and experimental results obtained by literature studies. Results show that the developed numerical model can predict transient behavior of the SGSPs with a good accuracy. As an application of this model, temperature, salt concentration, energy stored and storage efficiency variations of a proposed SGSP are analyzed under Mediterranean climate. The results show that the lower convective zone(LCZ) temperature increases from 15 °C to around 95 °C whereas the temperature of the upper convective zone(UCZ) varies sinusoidally depending on that of the ambient air. Furthermore, the salt concentration of the LCZ decreases from 250kg/m3 to around 248kg/m3 while that of the UCZ increases from50 kg/m3 to about 52kg/m3. Additionally, the thermal energy stored is around 135MJ with an efficiency of about 38% which confirms the capacity of the SGSP to store thermal energy as sensible heat.
- Open Access
- 12 January 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (2) , 1479
Effects of Double-Diffusive Convection on Calculation Time and Accuracy Results of a Salt Gradient Solar Pond: Numerical Investigation and Experimental Validation
The main aim of this study is to investigate numerically and experimentally the effects of double-diffusive convection on calculation time and accuracy results of a Salt Gradient Solar Pond (SGSP). To this end, two-numerical models are developed based on the Fortran programming language. The first one is based on energy balance neglecting the development of double-diffusive convection, while the second is two-dimensional and is based on Navier-Stokes, heat, and mass transfer equations considering the development of double-diffusive convection. The heat losses via the upper part, bottom, and vertical walls, as well as the internal heating of saltwater, are considered. In order to validate and compare both numerical models, a laboratory-scale SGSP is designed, built, and tested indoors for 82 h. Results indicate that the two numerical models developed can predict the SGSP thermal behavior with good accuracy. Furthermore, the average relative error between experimental and numerical results is around 9.39% for Upper Convective Zone (UCZ) and 2.92% for Lower Convective Zone (LCZ) based on the first model. This error reduces to about 5.98% for UCZ and 3.74% for LCZ by using the second model. Consequently, the neglect of double-diffusive convection in the SGSP modeling tends to overestimate the thermal energy stored in the storage zone by about 4.3%. Based on the calculation time analysis, results show that the second model returns a calculation time hundreds of times larger than the first one and, accordingly, an increase in computational cost.
- 12 January 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (2) , 1479
Open AccessEffects of Double-Diffusive Convection on Calculation Time and Accuracy Results of a Salt Gradient Solar Pond: Numerical Investigation and Experimental Validation
The main aim of this study is to investigate numerically and experimentally the effects of double-diffusive convection on calculation time and accuracy results of a Salt Gradient Solar Pond (SGSP). To this end, two-numerical models are developed based on the Fortran programming language. The first one is based on energy balance neglecting the development of double-diffusive convection, while the second is two-dimensional and is based on Navier-Stokes, heat, and mass transfer equations considering the development of double-diffusive convection. The heat losses via the upper part, bottom, and vertical walls, as well as the internal heating of saltwater, are considered. In order to validate and compare both numerical models, a laboratory-scale SGSP is designed, built, and tested indoors for 82 h. Results indicate that the two numerical models developed can predict the SGSP thermal behavior with good accuracy. Furthermore, the average relative error between experimental and numerical results is around 9.39% for Upper Convective Zone (UCZ) and 2.92% for Lower Convective Zone (LCZ) based on the first model. This error reduces to about 5.98% for UCZ and 3.74% for LCZ by using the second model. Consequently, the neglect of double-diffusive convection in the SGSP modeling tends to overestimate the thermal energy stored in the storage zone by about 4.3%. Based on the calculation time analysis, results show that the second model returns a calculation time hundreds of times larger than the first one and, accordingly, an increase in computational cost.
- Open Access
- 17 January 2022
- Published by EDP Sciences
- Vol. 336, 00020
Numerical investigation of solar energy storage by a salt gradient solar pond in several Moroccan cities
Numerical investigation of solar energy storage by a Salt Gradient Solar Pond (SGSP) in several Moroccan cities (Marrakesh, Ouarzazate, Tangier and Ifrane) is presented in this paper. For this purpose, the SGSP considered is assimilated to an open parallelipedic cavity in which the vertical and bottom walls are thermally insulated. The one-dimensional numerical model developed in Python programming language is based on the energy balance of each SGSP zone in which the heat losses via the SGSP free surface are retained. The numerical results obtained from the model developed are satisfactorily compared and validated against those obtained experimentally and numerically from a literature study. According to the results of one year of the SGSP operation, the storage zone temperature and the energy stored in the SGSP located in Ouarzazate city are the highest and reach maximum values in July (about 128 °C and 146 MJ respectively). Moreover, comparisons between different mass flow rates (0.01 Kg/s, 0.05 Kg/s and 0.09 Kg/s) of heat exchanger placed in the storage zone show that the optimal one is 0.09 Kg/s as it ensures the maximum energy extraction.
- 17 January 2022
- Published by EDP Sciences
- Vol. 336, 00020
Open AccessNumerical investigation of solar energy storage by a salt gradient solar pond in several Moroccan cities
Numerical investigation of solar energy storage by a Salt Gradient Solar Pond (SGSP) in several Moroccan cities (Marrakesh, Ouarzazate, Tangier and Ifrane) is presented in this paper. For this purpose, the SGSP considered is assimilated to an open parallelipedic cavity in which the vertical and bottom walls are thermally insulated. The one-dimensional numerical model developed in Python programming language is based on the energy balance of each SGSP zone in which the heat losses via the SGSP free surface are retained. The numerical results obtained from the model developed are satisfactorily compared and validated against those obtained experimentally and numerically from a literature study. According to the results of one year of the SGSP operation, the storage zone temperature and the energy stored in the SGSP located in Ouarzazate city are the highest and reach maximum values in July (about 128 °C and 146 MJ respectively). Moreover, comparisons between different mass flow rates (0.01 Kg/s, 0.05 Kg/s and 0.09 Kg/s) of heat exchanger placed in the storage zone show that the optimal one is 0.09 Kg/s as it ensures the maximum energy extraction.
- Open Access
- 1 January 2022
- Published by Tech Science Press in Fluid Dynamics & Materials Processing
- Vol. 18 (5) , 1319-1329
Numerical Analysis of the Influence of Buoyancy Ratio and Dufour Parameter on Thermosolutal Convection in a Square Salt Gradient Solar Pond
Revise the abstract as follows: This work aims to investigate numerically the influence of the buoyancy ratio and the Dufour parameter on thermosolutal convection in a square Salt Gradient Solar Pond (SGSP). The absorption of solar radiation by the saline water, the heat losses and the wind effects via the SGSP free surface are considered. The mathematical model is based on the Navier-Stokes equations used in synergy with the thermal energy equation. These equations are solved using the finite volume method and the Gauss algorithm. Velocity-pressure coupling is implemented through the SIMPLE algorithm. Simulations of the SGSP are performed for three values of buoyancy ratio (N = 1, 2 and 10), three values of Dufour parameter (Dƒ = 0, 0.2 and 0.8) and some sample meteorological data (Tangier, Morocco). Results show that the highest dimensionless temperature of the storage zone is found for N = 10. In the same zone and for the same value of N, the dimensionless salt concentration decreases very slightly versus time (unlike for N = 1 or 2). Moreover, increasing Df from 0 to 0.8 causes a decrease in the dimensionless temperature of the SGSP storage zone and this decrease is more pronounced for N = 1 and N = 2.
- 1 January 2022
- Published by Tech Science Press in Fluid Dynamics & Materials Processing
- Vol. 18 (5) , 1319-1329
Open AccessNumerical Analysis of the Influence of Buoyancy Ratio and Dufour Parameter on Thermosolutal Convection in a Square Salt Gradient Solar Pond
Revise the abstract as follows: This work aims to investigate numerically the influence of the buoyancy ratio and the Dufour parameter on thermosolutal convection in a square Salt Gradient Solar Pond (SGSP). The absorption of solar radiation by the saline water, the heat losses and the wind effects via the SGSP free surface are considered. The mathematical model is based on the Navier-Stokes equations used in synergy with the thermal energy equation. These equations are solved using the finite volume method and the Gauss algorithm. Velocity-pressure coupling is implemented through the SIMPLE algorithm. Simulations of the SGSP are performed for three values of buoyancy ratio (N = 1, 2 and 10), three values of Dufour parameter (Dƒ = 0, 0.2 and 0.8) and some sample meteorological data (Tangier, Morocco). Results show that the highest dimensionless temperature of the storage zone is found for N = 10. In the same zone and for the same value of N, the dimensionless salt concentration decreases very slightly versus time (unlike for N = 1 or 2). Moreover, increasing Df from 0 to 0.8 causes a decrease in the dimensionless temperature of the SGSP storage zone and this decrease is more pronounced for N = 1 and N = 2.
- 26 April 2021
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2345 (1) , 020003
Numerical study of Soret and Dufour coefficients on heat and mass transfer in a salt gradient solar pond
In this work, we investigate numerically the effects of Soret and Dufour coefficients on heat and mass transfer in a Salt Gradient Solar Pond (SGSP) using the meteorological data of Tangier (Morocco). This SGSP consists of a square cavity filled with a mixture of water and salt. Transfers equations are solved via the finite volume method and the Gauss method. The SIMPLE algorithm is used to link the velocity and pressure fields. The numerical code, we developed in FORTRAN 95, is first validated by applying it to experimental and numerical studies of the literature. Then, we analyze the effects of Soret and Dufour coefficients on heat and mass transfer inside the SGSP. The results show that, during time, heat and mass transfer are not influenced by Soret coefficient. Nevertheless, increasing Dufour coefficient enhance heat and mass transfer inside the SGSP and disrupts its working mechanism.
- 26 April 2021
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2345 (1) , 020003
Numerical study of Soret and Dufour coefficients on heat and mass transfer in a salt gradient solar pond
In this work, we investigate numerically the effects of Soret and Dufour coefficients on heat and mass transfer in a Salt Gradient Solar Pond (SGSP) using the meteorological data of Tangier (Morocco). This SGSP consists of a square cavity filled with a mixture of water and salt. Transfers equations are solved via the finite volume method and the Gauss method. The SIMPLE algorithm is used to link the velocity and pressure fields. The numerical code, we developed in FORTRAN 95, is first validated by applying it to experimental and numerical studies of the literature. Then, we analyze the effects of Soret and Dufour coefficients on heat and mass transfer inside the SGSP. The results show that, during time, heat and mass transfer are not influenced by Soret coefficient. Nevertheless, increasing Dufour coefficient enhance heat and mass transfer inside the SGSP and disrupts its working mechanism.
- 1 March 2021
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 161
Soret and Dufour effects on thermosolutal convection developed in a salt gradient solar pond
- 1 March 2021
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 161
Soret and Dufour effects on thermosolutal convection developed in a salt gradient solar pond
- 1 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 16, 1-6
Soret and Dufour effects on thermal storage and storage efficiency of a salt gradient solar pond
A two-dimensional numerical study is developed to investigate the impact of Soret and Dufour effects on temperatures, heat storage and storage efficiency of a salt gradient solar pond (SGSP). It consists of a square enclosure filled with a mixture of water and salt. The vertical and bottom walls are adiabatic and impermeable. The transfer equations are solved using the finite volume method and the Gauss method. The link between the pressure and velocity fields is assumed by the SIMPLE algorithm. The numerical code, developed and written in FORTRAN 95, was validated by applying it to experimental and numerical studies of the literature. We analyze the influence of Dufour and Soret effects on heat storage and the efficiency of the SGSP. Simulations of the functioning of the SGSP were performed using meteorological data of Tangier (Morocco). Results show that the Dufour effect on the thermal performance of the SGSP is more pronounced than that the Soret effect.
- 1 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 16, 1-6
Soret and Dufour effects on thermal storage and storage efficiency of a salt gradient solar pond
A two-dimensional numerical study is developed to investigate the impact of Soret and Dufour effects on temperatures, heat storage and storage efficiency of a salt gradient solar pond (SGSP). It consists of a square enclosure filled with a mixture of water and salt. The vertical and bottom walls are adiabatic and impermeable. The transfer equations are solved using the finite volume method and the Gauss method. The link between the pressure and velocity fields is assumed by the SIMPLE algorithm. The numerical code, developed and written in FORTRAN 95, was validated by applying it to experimental and numerical studies of the literature. We analyze the influence of Dufour and Soret effects on heat storage and the efficiency of the SGSP. Simulations of the functioning of the SGSP were performed using meteorological data of Tangier (Morocco). Results show that the Dufour effect on the thermal performance of the SGSP is more pronounced than that the Soret effect.
- 1 January 2020
- Published by Elsevier in Materials Today: Proceedings
- Vol. 30, 883-888
Modeling of a salt gradient solar pond under Moroccan climate taking into account double-diffusive convection
- 1 January 2020
- Published by Elsevier in Materials Today: Proceedings
- Vol. 30, 883-888
Modeling of a salt gradient solar pond under Moroccan climate taking into account double-diffusive convection