Heli Koskimäki
Heli Koskimäki has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Juha Röning
University of Oulu
26 shared publications - Pekka Siirtola
University of Oulu
16 shared publications Perttu Laurinen
Data Mining Group, Department of Electrical and Information Engineering, University of Oulu, Finland
6 shared publications- Hannu Kinnunen
Oura Health, Oulu, Finland
4 shared publications Pekka Siirtola
University of Oulu, Oulu, Finland
4 shared publicationsIlmari Juutilainen
Data Mining Group, University of Oulu
3 shared publications
Latest Publications
- Open Access
- 21 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 210, 148-154
The Impact of Smartphone Usage on Circadian Cycles: A Case Study with Wearable Ring
Smartphones are an integral part of our daily life, bringing both positive and negative impacts with them. Recent studies suggest that extensive and untimely smartphone usage directly affects circadian rhythm, i.e. alertness-sleepiness cycle. In this paper, we analyse sleep quality data collected through a wearable ring together with the smartphone interaction in bed just before falling asleep. First, we show that the sleep-tracking devices measuring sleep quality and quantity are also feasible to be used for researching circadian cycles. Second, we analyse the statistical relationships between in-bed smartphone interaction and different sleep metrics, out of which some are more prominent for future use and some present interesting negative results. Third, we present three baseline prediction models to predict sleep quality and circadian cycle based on smartphone app usage, with accuracy ranging from 31% to 67%.
- 21 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 210, 148-154
Open AccessThe Impact of Smartphone Usage on Circadian Cycles: A Case Study with Wearable Ring
Smartphones are an integral part of our daily life, bringing both positive and negative impacts with them. Recent studies suggest that extensive and untimely smartphone usage directly affects circadian rhythm, i.e. alertness-sleepiness cycle. In this paper, we analyse sleep quality data collected through a wearable ring together with the smartphone interaction in bed just before falling asleep. First, we show that the sleep-tracking devices measuring sleep quality and quantity are also feasible to be used for researching circadian cycles. Second, we analyse the statistical relationships between in-bed smartphone interaction and different sleep metrics, out of which some are more prominent for future use and some present interesting negative results. Third, we present three baseline prediction models to predict sleep quality and circadian cycle based on smartphone app usage, with accuracy ranging from 31% to 67%.
- Top Cited PapersOpen Access
- 1 April 2020
- Published by IOP Publishing in Physiological Measurement
- Vol. 41 (4) , 04NT01
Feasible assessment of recovery and cardiovascular health: accuracy of nocturnal HR and HRV assessed via ring PPG in comparison to medical grade ECG
Objective: To validate the accuracy of the Oura ring in the quantification of resting heart rate (HR) and heart rate variability (HRV). Background: Wearable devices have become comfortable, lightweight, and technologically advanced for assessing health behavior. As an example, the novel Oura ring integrates daily physical activity and nocturnal cardiovascular measurements. Ring users can follow their autonomic nervous system responses to their daily behavior based on nightly changes in HR and HRV, and adjust their behavior accordingly after self-reflection. As wearable photoplethysmogram (PPG) can be disrupted by several confounding influences, it is crucial to demonstrate the accuracy of ring measurements. Approach: Nocturnal HR and HRV were assessed in 49 adults with simultaneous measurements from the Oura ring and the gold standard ECG measurement. Female and male participants with a wide age range (15–72 years) and physical activity status were included. Regression analysis between ECG and the ring outcomes was performed. Main results: Very high agreement between the ring and ECG was observed for nightly average HR and HRV (r2 = 0.996 and 0.980, respectively) with a mean bias of −0.63 bpm and −1.2 ms. High agreement was also observed across 5 min segments within individual nights in (r2 = 0.869 ± 0.098 and 0.765 ± 0.178 in HR and HRV, respectively). Significance: Present findings indicate high validity of the Oura ring in the assessment of nocturnal HR and HRV in healthy adults. The results show the utility of this miniaturised device as a lifestyle management tool in long-term settings. High quality PPG signal results prompt future studies utilizing ring PPG towards clinically relevant health outcomes.
- 1 April 2020
- Published by IOP Publishing in Physiological Measurement
- Vol. 41 (4) , 04NT01
Top Cited PapersOpen AccessFeasible assessment of recovery and cardiovascular health: accuracy of nocturnal HR and HRV assessed via ring PPG in comparison to medical grade ECG
Objective: To validate the accuracy of the Oura ring in the quantification of resting heart rate (HR) and heart rate variability (HRV). Background: Wearable devices have become comfortable, lightweight, and technologically advanced for assessing health behavior. As an example, the novel Oura ring integrates daily physical activity and nocturnal cardiovascular measurements. Ring users can follow their autonomic nervous system responses to their daily behavior based on nightly changes in HR and HRV, and adjust their behavior accordingly after self-reflection. As wearable photoplethysmogram (PPG) can be disrupted by several confounding influences, it is crucial to demonstrate the accuracy of ring measurements. Approach: Nocturnal HR and HRV were assessed in 49 adults with simultaneous measurements from the Oura ring and the gold standard ECG measurement. Female and male participants with a wide age range (15–72 years) and physical activity status were included. Regression analysis between ECG and the ring outcomes was performed. Main results: Very high agreement between the ring and ECG was observed for nightly average HR and HRV (r2 = 0.996 and 0.980, respectively) with a mean bias of −0.63 bpm and −1.2 ms. High agreement was also observed across 5 min segments within individual nights in (r2 = 0.869 ± 0.098 and 0.765 ± 0.178 in HR and HRV, respectively). Significance: Present findings indicate high validity of the Oura ring in the assessment of nocturnal HR and HRV in healthy adults. The results show the utility of this miniaturised device as a lifestyle management tool in long-term settings. High quality PPG signal results prompt future studies utilizing ring PPG towards clinically relevant health outcomes.
- Open Access
- 29 November 2019
- Published by Springer Nature in BMC Women's Health
- Vol. 19 (1) , 1-10
Nocturnal finger skin temperature in menstrual cycle tracking: ambulatory pilot study using a wearable Oura ring
Background: Body temperature is a common method in menstrual cycle phase tracking because of its biphasic form. In ambulatory studies, different skin temperatures have proven to follow a similar pattern. The aim of this pilot study was to assess the applicability of nocturnal finger skin temperature based on a wearable Oura ring to monitor menstrual cycle and predict menstruations and ovulations in real life. Methods: Volunteer women (n = 22) wore the Oura ring, measured ovulation through urine tests, and kept diaries on menstruations at an average of 114.7 days (SD 20.6), of which oral temperature was measured immediately after wake-up at an average of 1.9 cycles (SD 1.2). Skin and oral temperatures were compared by assessing daily values using repeated measures correlation and phase mean values and differences between phases using dependent t-test. Developed algorithms using skin temperature were tested to predict the start of menstruation and ovulation. The performance of algorithms was assessed with sensitivity and positive predictive values (true positive defined with different windows around the reported day). Results: Nocturnal skin temperatures and oral temperatures differed between follicular and luteal phases with higher temperatures in the luteal phase, with a difference of 0.30 °C (SD 0.12) for skin and 0.23 °C (SD 0.09) for oral temperature (p < 0.001). Correlation between skin and oral temperatures was found using daily temperatures (r = 0.563, p < 0.001) and differences between phases (r = 0.589, p = 0.004). Menstruations were detected with a sensitivity of 71.9–86.5% in window lengths of ±2 to ±4 days. Ovulations were detected with the best-performing algorithm with a sensitivity of 83.3% in fertile window from − 3 to + 2 days around the verified ovulation. Positive predictive values had similar percentages to those of sensitivities. The mean offset for estimations were 0.4 days (SD 1.8) for menstruations and 0.6 days (SD 1.5) for ovulations with the best-performing algorithm. Conclusions: Nocturnal skin temperature based on wearable ring showed potential for menstrual cycle monitoring in real life conditions.
- 29 November 2019
- Published by Springer Nature in BMC Women's Health
- Vol. 19 (1) , 1-10
Open AccessNocturnal finger skin temperature in menstrual cycle tracking: ambulatory pilot study using a wearable Oura ring
Background: Body temperature is a common method in menstrual cycle phase tracking because of its biphasic form. In ambulatory studies, different skin temperatures have proven to follow a similar pattern. The aim of this pilot study was to assess the applicability of nocturnal finger skin temperature based on a wearable Oura ring to monitor menstrual cycle and predict menstruations and ovulations in real life. Methods: Volunteer women (n = 22) wore the Oura ring, measured ovulation through urine tests, and kept diaries on menstruations at an average of 114.7 days (SD 20.6), of which oral temperature was measured immediately after wake-up at an average of 1.9 cycles (SD 1.2). Skin and oral temperatures were compared by assessing daily values using repeated measures correlation and phase mean values and differences between phases using dependent t-test. Developed algorithms using skin temperature were tested to predict the start of menstruation and ovulation. The performance of algorithms was assessed with sensitivity and positive predictive values (true positive defined with different windows around the reported day). Results: Nocturnal skin temperatures and oral temperatures differed between follicular and luteal phases with higher temperatures in the luteal phase, with a difference of 0.30 °C (SD 0.12) for skin and 0.23 °C (SD 0.09) for oral temperature (p < 0.001). Correlation between skin and oral temperatures was found using daily temperatures (r = 0.563, p < 0.001) and differences between phases (r = 0.589, p = 0.004). Menstruations were detected with a sensitivity of 71.9–86.5% in window lengths of ±2 to ±4 days. Ovulations were detected with the best-performing algorithm with a sensitivity of 83.3% in fertile window from − 3 to + 2 days around the verified ovulation. Positive predictive values had similar percentages to those of sensitivities. The mean offset for estimations were 0.4 days (SD 1.8) for menstruations and 0.6 days (SD 1.5) for ovulations with the best-performing algorithm. Conclusions: Nocturnal skin temperature based on wearable ring showed potential for menstrual cycle monitoring in real life conditions.
- Open Access
- 9 September 2019
- Published by Association for Computing Machinery (ACM)
- p. 1178-1181
Following the heart
- 9 September 2019
- Published by Association for Computing Machinery (ACM)
- p. 1178-1181
Open AccessFollowing the heart
- Open Access
- 12 June 2019
- Published by Association for Computing Machinery (ACM)
- p. 17-21
Wrist-worn Wearable Sensors to Understand Insides of the Human Body
- 12 June 2019
- Published by Association for Computing Machinery (ACM)
- p. 17-21
Open AccessWrist-worn Wearable Sensors to Understand Insides of the Human Body
- 12 April 2019
- Published by Oxford University Press (OUP) in SLEEP
- Vol. 42 (Supplement) , A407-A408
1013 Population Study Of Sleep Duration And Quality Using Data From Commercially Available Wearable Ring
Sleep is one of the main pillars of our health and wellbeing. Both short and long duration of sleep has been associated with obesity, diabetes, hypertension and cardiovascular diseases and even with greater risk of death. Nevertheless, the duration of the sleep is not the only quantity affecting the perceived quality of sleep but it can be divided into dimensions of quantity, continuity and timing. While continuity and timing are not well studied possibly due the difficulty of assessing them with questionnaires, the recent development of wearable and environmental sleep trackers can enable more versatile analysis of all these three dimensions. Thus, in this study sleep duration as well as the role of sleep consistency as contributor of sleep quality, are assessed in real-life settings. The data set consists of sleep data from the first Oura ring users where the studied metrics included overall sleep duration, long-term consistency vs sleep efficiency, and long-term consistency vs total sleep. To be included into this population a user needed at least 10 recorded nights available constituting a population of 9333 persons and including approximately 1.8 million nights. 50% of the population slept, on average, less than 7.0 hours per night. Moreover, lack of long-term sleep consistency was found to correlate with shorter sleep duration and lower sleep efficiency. It was shown that wearable Oura ring can be utilized in large population studies to reveal facts related to sleep duration. The link between the consistency of sleep timing could be studied. On average, half of the Oura users were observed to accumulate insufficient amount of sleep compared to NSF recommendations. Moreover, lack of consistency in sleep timing was found to correlate with shorter sleep duration and lower sleep efficiency. We therefore conclude that further experimentation to explore the potential of the Oura ring for tracking human sleep in large scale studies is justified. This work was supported by Oura Health Ltd.
- 12 April 2019
- Published by Oxford University Press (OUP) in SLEEP
- Vol. 42 (Supplement) , A407-A408
1013 Population Study Of Sleep Duration And Quality Using Data From Commercially Available Wearable Ring
Sleep is one of the main pillars of our health and wellbeing. Both short and long duration of sleep has been associated with obesity, diabetes, hypertension and cardiovascular diseases and even with greater risk of death. Nevertheless, the duration of the sleep is not the only quantity affecting the perceived quality of sleep but it can be divided into dimensions of quantity, continuity and timing. While continuity and timing are not well studied possibly due the difficulty of assessing them with questionnaires, the recent development of wearable and environmental sleep trackers can enable more versatile analysis of all these three dimensions. Thus, in this study sleep duration as well as the role of sleep consistency as contributor of sleep quality, are assessed in real-life settings. The data set consists of sleep data from the first Oura ring users where the studied metrics included overall sleep duration, long-term consistency vs sleep efficiency, and long-term consistency vs total sleep. To be included into this population a user needed at least 10 recorded nights available constituting a population of 9333 persons and including approximately 1.8 million nights. 50% of the population slept, on average, less than 7.0 hours per night. Moreover, lack of long-term sleep consistency was found to correlate with shorter sleep duration and lower sleep efficiency. It was shown that wearable Oura ring can be utilized in large population studies to reveal facts related to sleep duration. The link between the consistency of sleep timing could be studied. On average, half of the Oura users were observed to accumulate insufficient amount of sleep compared to NSF recommendations. Moreover, lack of consistency in sleep timing was found to correlate with shorter sleep duration and lower sleep efficiency. We therefore conclude that further experimentation to explore the potential of the Oura ring for tracking human sleep in large scale studies is justified. This work was supported by Oura Health Ltd.
- 8 October 2018
- Published by Association for Computing Machinery (ACM)
- p. 1396-1403
Open AccessOpenHAR
- Open Access
- 8 October 2018
- Published by Association for Computing Machinery (ACM)
- p. 714-717
How Do We Sleep
- 8 October 2018
- Published by Association for Computing Machinery (ACM)
- p. 714-717
Open AccessHow Do We Sleep
- Open Access
Using Sleep Time Data from Wearable Sensors for Early Detection of Migraine Attacks
The migraine is a chronic, incapacitating neurovascular disorder, characterized by attacks of severe headache and autonomic nervous system dysfunction. Among the working age population, the costs of migraine are 111 billion euros in Europe alone. The early detection of migraine attacks would reduce these costs, as it would shorten the migraine attack by enabling correct timing when taking preventive medication. In this article, whether it is possible to detect migraine attacks beforehand using wearable sensors is studied, and t preliminary results about how accurate the recognition can be are provided. The data for the study were collected from seven study subjects using a wrist-worn Empatica E4 sensor, which measures acceleration, galvanic skin response, blood volume pulse, heart rate and heart rate variability, and temperature. Only sleep time data were used in this study. A novel method to increase the number of training samples is introduced, and the results show that, using personal recognition models and quadratic discriminant analysis as a classifier, balanced accuracy for detecting attacks one night prior is over 84%. While this detection rate is high, the results also show that balance accuracy varies greatly between study subjects, which shows how complicated the problem actually is. However, at this point, the results are preliminary as the data set contains only seven study subjects, so these do not cover all migraine types. If the findings of this article can be confirmed in a larger population, it may potentially contribute to early diagnosis of migraine attacks.
Open AccessUsing Sleep Time Data from Wearable Sensors for Early Detection of Migraine Attacks
The migraine is a chronic, incapacitating neurovascular disorder, characterized by attacks of severe headache and autonomic nervous system dysfunction. Among the working age population, the costs of migraine are 111 billion euros in Europe alone. The early detection of migraine attacks would reduce these costs, as it would shorten the migraine attack by enabling correct timing when taking preventive medication. In this article, whether it is possible to detect migraine attacks beforehand using wearable sensors is studied, and t preliminary results about how accurate the recognition can be are provided. The data for the study were collected from seven study subjects using a wrist-worn Empatica E4 sensor, which measures acceleration, galvanic skin response, blood volume pulse, heart rate and heart rate variability, and temperature. Only sleep time data were used in this study. A novel method to increase the number of training samples is introduced, and the results show that, using personal recognition models and quadratic discriminant analysis as a classifier, balanced accuracy for detecting attacks one night prior is over 84%. While this detection rate is high, the results also show that balance accuracy varies greatly between study subjects, which shows how complicated the problem actually is. However, at this point, the results are preliminary as the data set contains only seven study subjects, so these do not cover all migraine types. If the findings of this article can be confirmed in a larger population, it may potentially contribute to early diagnosis of migraine attacks.
- 27 April 2018
- Published by Oxford University Press (OUP) in SLEEP
- Vol. 41 (suppl_1) , A120
0312 The HRV Of The Ring - Comparison Of Nocturnal HR And HRV Between A Commercially Available Wearable Ring And ECG
The beat of a healthy heart shows significant variation among the time intervals between heartbeats. Heart rate variability (HRV) consists of periodic and aperiodic changes in the duration of the cardiac “QRS-wave” cycle. Greater nocturnal HRV has been linked with better sleep quality in healthy and clinical populations. Measurement of HRV during sleep might therefore have applications for sleep related maladies, but to collect long term data there is a strong need for comfortable measurement devices that do not disturb rest. Here we assess the Oura ring’s (Ring) ability to fill this need. We measured nocturnal photopletysmogram (PPG) based inter-beat interval (IBI) data with the Ring (Oura Health Ltd, Oulu, Finland) and simultaneous R-R interval data with Faros 360 electrocardiogram (ECG) device (Mega Electronics, Kuopio, Finland) in 10 healthy individuals (3 female, 7 male). All subjects had the Ring on both hands, resulting in 20 nightly recordings for analysis. Root mean square of successive differences (rMSSD) was used as the HRV measurement. We determined heart rate HR and HRV as nightly averages for the Ring using only the normal IBI values (HRRing and rMSSDRing) and for ECG using Kubios software with automatic filter having medium setting (HRECG and rMSSDECG). The agreement between the methods was assessed by correlation analysis using Matlab software. High correlation was observed between HRRing and HRECG (r2 = .998) with a bias of -0.53 bpm (p<.001). Moreover, high correlation was found between rMSSDRing and rMSSDECG (r2 = .967) with a bias of -0.47 (p<.001). The observed HR range was 48 to 66 bpm, and rMSSD range was 21 to 78 ms. As a ring provides high wearing comfort for the measurement of nocturnal HR and HRV, the present confirmation about the reliability of the HR and HRV numbers is welcome for sleep and recovery related long-term studies. High correlation observed in rMSSD encourage comparing other parameters of HRV, too. This work was supported by Oura Health Ltd.
- 27 April 2018
- Published by Oxford University Press (OUP) in SLEEP
- Vol. 41 (suppl_1) , A120
0312 The HRV Of The Ring - Comparison Of Nocturnal HR And HRV Between A Commercially Available Wearable Ring And ECG
The beat of a healthy heart shows significant variation among the time intervals between heartbeats. Heart rate variability (HRV) consists of periodic and aperiodic changes in the duration of the cardiac “QRS-wave” cycle. Greater nocturnal HRV has been linked with better sleep quality in healthy and clinical populations. Measurement of HRV during sleep might therefore have applications for sleep related maladies, but to collect long term data there is a strong need for comfortable measurement devices that do not disturb rest. Here we assess the Oura ring’s (Ring) ability to fill this need. We measured nocturnal photopletysmogram (PPG) based inter-beat interval (IBI) data with the Ring (Oura Health Ltd, Oulu, Finland) and simultaneous R-R interval data with Faros 360 electrocardiogram (ECG) device (Mega Electronics, Kuopio, Finland) in 10 healthy individuals (3 female, 7 male). All subjects had the Ring on both hands, resulting in 20 nightly recordings for analysis. Root mean square of successive differences (rMSSD) was used as the HRV measurement. We determined heart rate HR and HRV as nightly averages for the Ring using only the normal IBI values (HRRing and rMSSDRing) and for ECG using Kubios software with automatic filter having medium setting (HRECG and rMSSDECG). The agreement between the methods was assessed by correlation analysis using Matlab software. High correlation was observed between HRRing and HRECG (r2 = .998) with a bias of -0.53 bpm (p<.001). Moreover, high correlation was found between rMSSDRing and rMSSDECG (r2 = .967) with a bias of -0.47 (p<.001). The observed HR range was 48 to 66 bpm, and rMSSD range was 21 to 78 ms. As a ring provides high wearing comfort for the measurement of nocturnal HR and HRV, the present confirmation about the reliability of the HR and HRV numbers is welcome for sleep and recovery related long-term studies. High correlation observed in rMSSD encourage comparing other parameters of HRV, too. This work was supported by Oura Health Ltd.