Carl Flink
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Carl Flink has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Eric England
Department of Radiology, University of Cincinnati Medical Center, Cincinnati, USA
2 shared publications Achala Vagal
University of Cincinnati, 234, Goodman Street, Cincinnati, OH, 45267
1 shared publication- Adam J. Dugan
Department of Biostatistics, University of Kentucky, Lexington, USA
1 shared publication Alisa Kanfi
University of Cincinnati, 234, Goodman Street, Cincinnati, OH, 45267
1 shared publication- Alvin I. Mushlin
Departments of Population Health Sciences and Medicine, Weill Cornell Medical College, New York, New York (A.I.M.)
1 shared publication - Armonde A. Baghdanian
University of Southern California, Los Angeles, United States of America
1 shared publication
Latest Publications
- Open Access
- 24 July 2024
- Published by Springer Nature in Emergency Radiology
- Vol. 31 (5) , 725-731
Effects of night-float shifts on cognitive function among radiology residents
Background: Many radiology programs utilize a night-float system to mitigate the effects of fatigue, improve patient care, and provide faster report turnaround times. Prior studies have demonstrated an increase in discrepancy rates during night-float shifts. Objectives: This study was performed to examine the effects of night-float shift work on radiology resident cognition. We hypothesized that there would be diminished cognitive function on testing following night-float shifts when compared to testing following day shifts. Methods: Diagnostic radiology residents in their second to fifth years of residency at a single institution were recruited to participate in this pilot study. Cognitive function was evaluated using the Lumosity Neurocognitive Performance Tests (NCPT), standardized performance tests that provide real-time, objective measurements of cognitive function. Study participants completed the NCPT in 5 sessions following 5 consecutive day shifts to evaluate their baseline cognitive function. The tests were re-administered at the end of consecutive night-float shifts to assess for any changes. Sleep was objectively monitored using actigraphy devices worn around the wrist during all study weeks. Descriptive and summary statistics were performed. Results: 23 prospectively recruited diagnostic radiology residents working night-float shifts took a mean 13.6 (± 5.1) neurocognitive performance tests during the study period. There was a statistically significant decline in 2 of the 6 cognitive tests administered, signifying a decrease in attention, speed, and complex reasoning ability. Night-float shifts were significantly longer than the day shifts and associated with a significantly higher study volume and cross-sectional study volume. Fitbit data demonstrated that there were no significant differences in level of activity while awake. However, participants slept significantly longer during day shifts. Conclusions: A sample of 23 radiology residents working night-float shifts demonstrated declines in attention, speed, and complex reasoning ability following sequential administration of standardized neurocognitive performance tests. While the sample size is small, these findings demonstrate the potential deleterious effects of night-float shift work and provide evidence to support further inquiry into this phenomenon.
- 24 July 2024
- Published by Springer Nature in Emergency Radiology
- Vol. 31 (5) , 725-731
Open AccessEffects of night-float shifts on cognitive function among radiology residents
Background: Many radiology programs utilize a night-float system to mitigate the effects of fatigue, improve patient care, and provide faster report turnaround times. Prior studies have demonstrated an increase in discrepancy rates during night-float shifts. Objectives: This study was performed to examine the effects of night-float shift work on radiology resident cognition. We hypothesized that there would be diminished cognitive function on testing following night-float shifts when compared to testing following day shifts. Methods: Diagnostic radiology residents in their second to fifth years of residency at a single institution were recruited to participate in this pilot study. Cognitive function was evaluated using the Lumosity Neurocognitive Performance Tests (NCPT), standardized performance tests that provide real-time, objective measurements of cognitive function. Study participants completed the NCPT in 5 sessions following 5 consecutive day shifts to evaluate their baseline cognitive function. The tests were re-administered at the end of consecutive night-float shifts to assess for any changes. Sleep was objectively monitored using actigraphy devices worn around the wrist during all study weeks. Descriptive and summary statistics were performed. Results: 23 prospectively recruited diagnostic radiology residents working night-float shifts took a mean 13.6 (± 5.1) neurocognitive performance tests during the study period. There was a statistically significant decline in 2 of the 6 cognitive tests administered, signifying a decrease in attention, speed, and complex reasoning ability. Night-float shifts were significantly longer than the day shifts and associated with a significantly higher study volume and cross-sectional study volume. Fitbit data demonstrated that there were no significant differences in level of activity while awake. However, participants slept significantly longer during day shifts. Conclusions: A sample of 23 radiology residents working night-float shifts demonstrated declines in attention, speed, and complex reasoning ability following sequential administration of standardized neurocognitive performance tests. While the sample size is small, these findings demonstrate the potential deleterious effects of night-float shift work and provide evidence to support further inquiry into this phenomenon.
- 1 October 2021
- Published by Springer Nature in Emergency Radiology
- Vol. 29 (1) , 147-159
Imaging review of penile pathologies encountered in the emergency department
While penile pathology is uncommon, prompt diagnosis and treatment of emergent and urgent penile pathology are necessary to prevent complications. This paper will review the imaging findings of the most common critical penile pathologies, including traumatic, vascular, infectious, foreign body-related, and urethral pathology, in addition to penile prosthesis complications. Each entity will be discussed in the context of presentation and treatment and complications of each pathology will be discussed.
- 1 October 2021
- Published by Springer Nature in Emergency Radiology
- Vol. 29 (1) , 147-159
Imaging review of penile pathologies encountered in the emergency department
While penile pathology is uncommon, prompt diagnosis and treatment of emergent and urgent penile pathology are necessary to prevent complications. This paper will review the imaging findings of the most common critical penile pathologies, including traumatic, vascular, infectious, foreign body-related, and urethral pathology, in addition to penile prosthesis complications. Each entity will be discussed in the context of presentation and treatment and complications of each pathology will be discussed.
- 1 March 2021
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 298 (3) , E165
Reflection on the Evaluation of Radiologists' Performance during Off-Hours Shifts
- 1 March 2021
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 298 (3) , E165
Reflection on the Evaluation of Radiologists' Performance during Off-Hours Shifts
- 2 February 2021
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 299 (1) , 122-130
American Society of Emergency Radiology Multicenter Blunt Splenic Trauma Study: CT and Clinical Findings
An increase in interventional radiologic (IR) management of blunt splenic trauma was observed during the study period. Vascular injuries were identified at CT more frequently than previously report... Background Treatment of blunt splenic trauma (BST) continues to evolve with improved imaging for detection of splenic vascular injuries. Purpose To report on treatments for BST from 11 trauma cente...
- 2 February 2021
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 299 (1) , 122-130
American Society of Emergency Radiology Multicenter Blunt Splenic Trauma Study: CT and Clinical Findings
An increase in interventional radiologic (IR) management of blunt splenic trauma was observed during the study period. Vascular injuries were identified at CT more frequently than previously report... Background Treatment of blunt splenic trauma (BST) continues to evolve with improved imaging for detection of splenic vascular injuries. Purpose To report on treatments for BST from 11 trauma cente...
- 1 August 2020
- Published by Elsevier in Academic Radiology
- Vol. 27 (8) , 1140-1146
Radiology Residency Program Management in the COVID Era – Strategy and Reality
- 1 August 2020
- Published by Elsevier in Academic Radiology
- Vol. 27 (8) , 1140-1146
Radiology Residency Program Management in the COVID Era – Strategy and Reality
- 18 March 2020
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 102 (6) , 468-476
Examining Timeliness of Total Knee Replacement Among Patients with Knee Osteoarthritis in the U.S.
Background: Patients with knee osteoarthritis may undergo total knee replacement too early or may delay or underuse this procedure. We quantified these categories of total knee replacement utilization in 2 cohorts of participants with knee osteoarthritis and investigated factors associated with each category. Methods: Data were pooled from 2 multicenter cohort studies that collected demographic, patient-reported, radiographic, clinical examination, and total knee replacement utilization information longitudinally on 8,002 participants who had or were at risk for knee osteoarthritis and were followed for up to 8 years. Validated total knee replacement appropriateness criteria were longitudinally applied to classify participants as either potentially appropriate or likely inappropriate for total knee replacement. Participants were further classified on the basis of total knee replacement utilization into 3 categories: timely (indicating that the patient had total knee replacement within 2 years after the procedure had become potentially appropriate), potentially appropriate but knee not replaced (indicating that the knee had remained unreplaced for >2 years after the procedure had become potentially appropriate), and premature (indicating that the procedure was likely inappropriate but had been performed). Utilization rates were calculated, and factors associated with each category were identified. Results: Among 8,002 participants, 3,417 knees fulfilled our inclusion and exclusion criteria and were classified into 1 of 3 utilization categories as follows: 290 knees (8% of the total and 9% of the knees for which replacement was potentially appropriate) were classified as “timely”, 2,833 knees (83% of the total and 91% of those for which replacement was potentially appropriate) were classified as “potentially appropriate but not replaced”, and 294 knees (comprising 9% of the total and 26% of the 1,114 total knee replacements performed) were considered to be “likely inappropriate” yet underwent total knee replacement and were classified as “premature”. Of the knees that were potentially appropriate but were not replaced, 1,204 (42.5%) had severe symptoms. Compared with the patients who underwent timely total knee replacement, the likelihood of being classified as potentially appropriate but not undergoing total knee replacement was greater for black participants and the likelihood of having premature total knee replacement was lower among participants with a body mass index of >25 kg/m2 and those with depression. Conclusions: In 2 multicenter cohorts of patients with knee osteoarthritis, we observed substantial numbers of patients who had premature total knee replacement as well as of patients for whom total knee replacement was potentially appropriate but had not been performed >2 years after it had become potentially appropriate. Further understanding of these observations is needed, especially among the latter group. Clinical Relevance: Undergoing total knee replacement too early may result in little or no benefit while exposing the patient to the risks of a major operation, whereas waiting too long may cause limitations in physical activity that in turn increase the risk of additional disability and chronic disease; however, little is known about timing of this surgery. We quantified the extent of premature, timely, and delayed use, and found a high prevalence of both premature and delayed use.
- 18 March 2020
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 102 (6) , 468-476
Examining Timeliness of Total Knee Replacement Among Patients with Knee Osteoarthritis in the U.S.
Background: Patients with knee osteoarthritis may undergo total knee replacement too early or may delay or underuse this procedure. We quantified these categories of total knee replacement utilization in 2 cohorts of participants with knee osteoarthritis and investigated factors associated with each category. Methods: Data were pooled from 2 multicenter cohort studies that collected demographic, patient-reported, radiographic, clinical examination, and total knee replacement utilization information longitudinally on 8,002 participants who had or were at risk for knee osteoarthritis and were followed for up to 8 years. Validated total knee replacement appropriateness criteria were longitudinally applied to classify participants as either potentially appropriate or likely inappropriate for total knee replacement. Participants were further classified on the basis of total knee replacement utilization into 3 categories: timely (indicating that the patient had total knee replacement within 2 years after the procedure had become potentially appropriate), potentially appropriate but knee not replaced (indicating that the knee had remained unreplaced for >2 years after the procedure had become potentially appropriate), and premature (indicating that the procedure was likely inappropriate but had been performed). Utilization rates were calculated, and factors associated with each category were identified. Results: Among 8,002 participants, 3,417 knees fulfilled our inclusion and exclusion criteria and were classified into 1 of 3 utilization categories as follows: 290 knees (8% of the total and 9% of the knees for which replacement was potentially appropriate) were classified as “timely”, 2,833 knees (83% of the total and 91% of those for which replacement was potentially appropriate) were classified as “potentially appropriate but not replaced”, and 294 knees (comprising 9% of the total and 26% of the 1,114 total knee replacements performed) were considered to be “likely inappropriate” yet underwent total knee replacement and were classified as “premature”. Of the knees that were potentially appropriate but were not replaced, 1,204 (42.5%) had severe symptoms. Compared with the patients who underwent timely total knee replacement, the likelihood of being classified as potentially appropriate but not undergoing total knee replacement was greater for black participants and the likelihood of having premature total knee replacement was lower among participants with a body mass index of >25 kg/m2 and those with depression. Conclusions: In 2 multicenter cohorts of patients with knee osteoarthritis, we observed substantial numbers of patients who had premature total knee replacement as well as of patients for whom total knee replacement was potentially appropriate but had not been performed >2 years after it had become potentially appropriate. Further understanding of these observations is needed, especially among the latter group. Clinical Relevance: Undergoing total knee replacement too early may result in little or no benefit while exposing the patient to the risks of a major operation, whereas waiting too long may cause limitations in physical activity that in turn increase the risk of additional disability and chronic disease; however, little is known about timing of this surgery. We quantified the extent of premature, timely, and delayed use, and found a high prevalence of both premature and delayed use.