    Air monitoring system based on IoT

    by Maryna Malakhova, Vladlen Zhivaga, Dmytro Shevchenko

    A number of researches associated the level of the COVID-19 corona virus lethality with the air pollution level. Many people are quarantined and staying at home because of a pandemic. Therefore the research and development of the air quality monitoring systems for domestic, industrial, and municipal use are relevant. Air quality monitoring systems` data collection and processing are also actual. This work aims to develop a budget intuitive integrated Internet of Things (IoT) system "Smart House". The IoT system for monitor air quality and control its parameters has been designed. The analysis of scientific-technical information, design, hardware, and software development of IoT "Smart House" system and an appropriate web application has been done to achieve this goal. Mathematical modeling, system programming, computer and microprocessor architecture, robotics, and methods of computer systems communication have been used. The integrated IoT system evaluates and analyzes the node for measuring the parameters of the environment in the room and the rules of fuzzy control according to experimental data, conducts a questionnaire to summarize the work. The main focus of the research has been on system integration, the ability to connect a large number of sensors, air quality control, and effective control of load devices in the room so that people can feel comfortable in the room. The IoT system analyzes the data about the environment indoors and outdoors using a certain algorithm. And it determines the node for measurement, using the minimum change and the minimum mean deviation. This algorithm allows us to stabilize the system management, to reduce the impact of erroneous or pseudo-erroneous data, etc. The functionality of the Smart House system allows to ensure indoor comfort and safety, to increase its energy efficiency and simplify the management of various householding automated control systems. In the future, it is going to improve the system by creating a more user-friendly interface, improving algorithms, expanding the functionality of the system, and in-depth study of the measuring and controlling air quality parameters process.


  • Open Access

    Exploring dependence of the patints’ radiation dose on the form of power supply voltage of x-ray tube

    by Sergiy Reva, Maryna Malakhova

    A brief analysis was conducted of organizational and technical methods of reducing the patient’s dose during radiographic examinations that are used in contemporary medicine. The paper considers optimization of the form of power supply voltage of X-ray tube as one of the efficient, but not sufficiently explored, areas of solving this problem. For its analysis, we propose a method of numerical simulation of the process of X-ray screening based on the experimentally obtained data. The results of experimental research are presented. Authors described the methods and results of calculation of influence of the form of power supply voltage of X-ray emitter on the total radiation dose of patients during medical examinations. To model the performance of several types of power units that operate on different physical principles, we created mathematical models that made it possible to calculate the instantaneous and integral values of all electrical parameters of X-ray tube, to find the integral dose of radiation in the plane of patient's location and to simulate a generalized reaction of the X-ray receiver of images on the ray flow that runs through the object of examination. Comparative analysis of the obtained results demonstrated that the total dose of radiation is significantly affected by the design and principle of operation of the power supply unit of X-ray tube, which is a part of the X-ray device. At the equivalent diagnostic quality of images, the difference in the X-ray dose of received by the patient in some modes may exceed 20 %. The assessment we performed indicates the feasibility of modernization of the outdated X-ray equipment with low frequency power units for the purpose of reducing the radiation dose through the improvement in the form of high voltage.