CCCarla Contaldi

Carla Contaldi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Carla Contaldi has a total of 31 co-authors. Here are the top co-authors by number of shared publications:

  • A D’onofrio

    Department of Cardiology. AORN dei Colli–Monaldi Hospital Heart Failure Unit Napoli; , Cedars–Sinai, Los Angeles, USA; Electrophysiology Unit Napoli; Electrophysiology Unit Napoli; Heart Failure Unit Napoli; Cardiology Unit Napoli; Heart Failure Unit Napoli

    1 shared publication
  • Alessandra Giamundo

    Department of Clinical Medicine, Cardiovascular and Immunological Sciences University of Naples Federico II Naples Italy

    1 shared publication
  • Alessandra Scatteia

    Advanced Cardiovascular Imaging Unit, Clinica Villa dei Fiori, 80011 Acerra, Italy

    1 shared publication
  • Brigida Ranieri

    IRCCS SYNLAB SDN, Via Emanuele Gianturco 113, 80143 Naples, Italy

    1 shared publication
  • Carlo di Nardo

    Department of Clinical Medicine, Cardiovascular and Immunological Sciences University of Naples Federico II Naples Italy

    1 shared publication
  • Ciro Mauro

    A.O.R.N. “Antonio Cardarelli

    1 shared publication

Latest Publications

  • Open Access

    C53 EFFECTS OF CARDIAC CONTRACTILITY MODULATION THERAPY ON LEFT VENTRICLE GLOBAL LONGITUDINAL STRAIN AND MYOCARDIAL MECHANO–ENERGETIC EFFICIENCY IN PATIENTS WITH HEART FAILURE WITH REDUCED EJECTION FRACTION

    by M Martucci, M Kittleson, S De Vivo, A D’onofrio, E Ammendola, G Nigro, C Contaldi, V Errigo, G Pacileo, D Masarone

    Impairment of myocardial mechano–energetic efficiency (MEE) is present in virtually all patients with heart failure with reduced ejection fraction (HFrEF). Cardiac contractility modulation (CCM) improves the quality of life and functional capacity, reduces hospitalizations, and induces biventricular reverse remodeling in patients with HFrEF. However, the effects of this innovative therapy on mechano–energetics efficiency and global longitudinal strain (GLS) are still unknown; therefore, the aim of this study is to evaluate whether CCM therapy can improve the MEE of patients with HFrEF. We enrolled 25 patients with HFrEF who received an Optimizer Smart implant (the device that develops CCM therapy) between January 2018 and January 2021. Clinical and echocardiographic data were obtained from all patients 24 hours before and six months after CCM therapy. At six months, follow–up patients who underwent CCM therapy showed an increase of left ventricular ejection fraction (30.8+7.1 vs. 36.1+6.9%; p = 0.032) as well a rise of GLS 10.3+2.7 vs.–12.9+4.2; p = 0.018), of MME (32.2 + 10.1 vs. 38.6 + 7.6 mL/s; p = 0.013) and of MEE index (18.4 + 6.3 vs 24.3 + 6.7 mL/s/g; p = 0.022). CCM therapy increased left ventricular performance, improving left ventricular ejection fraction, GLS, as well as MEE and MEEi.

  • Open Access

    P1449 CMR-driven computational modeling of right ventricular flow dynamics

    by F Capuano, L Romano, Y H Loke, S Dellegrottaglie, M Notorio, R Cocchia, B Ranieri, F Ferrara, C Contaldi, G Mirto, et al.

    Introduction: The analysis of intracardiac blood flow patterns can significantly contribute to improve the understanding and treatment of cardiovascular disease. In contrast to the substantial literature on the left side of the heart, there is currently a significant lack of knowledge about the fluid mechanics of the right heart – pulmonary circulation unit (RH-PCU), both in healthy and diseased conditions. Purpose: It is conjectured that computational modeling can be a key element to enhance current imaging techniques and provide quantitative insights into the unique RH-PCU biomechanics. Here we present a novel methodology that allows personalized numerical simulations of right heart flows, through a proper combination of cardiac magnetic resonance (CMR) with computational fluid dynamics (CFD). Methods and results: We developed a patient-specific pipeline from medical images to computational models, as depicted in the figure. First, the RV geometry is reconstructed from time-resolved CMR cine images, comprising short-axis and longitudinal slices of the heart, where feature-tracking techniques are used to extract the motion of the RV endocardium contours. A time-continuous description of the moving geometry is obtained through an image-registration algorithm based on diffeomorphic mappings. The moving model of the RV, including the outflow tract and proximal pulmonary arteries, is finally fed to a dedicated CFD solver. The tool is able to provide a detailed description of the velocity and pressure fields inside the right ventricle and proximal pulmonary arteries during all phases of the cardiac cycle. From these fields, global hemodynamic quantities such as vortex properties, kinetic energy, pressure gradients and hemodynamic forces can be computed. Conclusions: CMR-driven computational modeling of intra-ventricular flow enables a promising approach for understanding and evaluating the biomechanical environment of the right heart. This high-fidelity framework can be applied to investigate the RV response and adaptation to abnormal pressure and/or volume load conditions. It can also be used to reproduce the virtual flow that would realize in hypothetical conditions, and therefore adds predictive capabilities to modern flow imaging. The analysis may allow to determine an association between blood flow patterns and disease progression, and ultimately lead to derive and validate imaging biomarkers of clinical significance. Abstract P1449 Figure. Pipeline for patient-specific modeling


  • Open Access

    Assessment of Myocardial Fibrosis in Hypertrophic Cardiomyopathy by Cardiac Magnetic Resonance: Modalities and Clinical Applications

    by Carla Contaldi

    Hypertrophic cardiomyopathy (HCM) is a primary myocardial disease caused by mutations in sarcomeric contractile proteins, characterized by cardiomyocytes disarray, interstitial fibrosis, increased arteriolar wall thickness and scarring.Fibrosis could represent a substrate for the generation of malignant ventricular tachyarrhythmias, which represent the current pathway for sudden cardiac death and is responsible for passive diastolic dysfunction, that is the leading cause of dyspnea.The aim of this review is to depict the increasingly role of cardiac magnetic resonance (CMR) for assessment of myocardial fibrosis in HCM. This article will briefly review the current status of the novel CMR techniques (the Late Gadolinium Enhancement and the emerging T1 mapping) for identification, characterization and quantization of myocardial fibrosis in HCM.In addition, this review will discuss the most recent acquisition techniques, the new parameters and their possible clinical utility in diagnosis, therapeutic management and prognosis in HCM.


  • Speckle‐tracking analysis based on 2D echocardiography does not reliably measure left ventricular torsion

    by Valentina Parisi, Maria Angela Losi, Carla Contaldi, Elena Chiacchio, Fabio Pastore, Alessandra Scatteia, Alessandra Giamundo, Carlo di Nardo, Raffaella Lombardi, Sandro Betocchi

    Summary: Purpose: Worldwide left ventricular (LV) twist is measured by 2D speckle tracking acquiring apical short axis at a LV level where papillary muscles are no longer visible; however, we hypothesized that this methodological recommendation is not enough accurate to obtain a reliable measurement of apical rotation.Methods: We measured twist and untwist rate in 30 healthy subjects by following the earlier method. By 3D echocardiography, we identified two LV apex levels: (i) 3D Apex, defined as the last apical slice at which LV cavity was visible; (ii) 2D Apex, defined as the level where diameters are equal to those of apical LV short axis used for twist analysis in the same subject. The ratio between the distance of 2D Apex and 3D Apex from LV base was calculated and expressed as percentage (2D Apex/3D Apex).Results: 2D Apex/3D Apex was strongly related to the magnitude of twist and untwisting rate (r = 0·82, Pr = −0·46, P = 0·015, respectively). The only determinant of twist was 2D Apex/3D Apex (r2 = 0·68; r = 0·82; F ratio: 52·6, Pr2 = 0·42; r = 0·65; F ratio: 7·7; P = 0·003 for 2D Apex/3D Apex; and P = 0·011 for age).Conclusions: Left ventricular apical level acquisition, even when recorded in a standard manner, determines variability of twist mechanics measurements. Thus, current anatomical markers used to identify LV apex for twist analysis are not reliable and need different standardization. 3D echocardiography may help in such standardization.