TBTyson R. Baird

Tyson R. Baird

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Tyson R. Baird has a total of 33 co-authors. Here are the top co-authors by number of shared publications:

  • Alphonse Poklis

    Department of Forensic Science, Virginia Commonwealth University, Richmond, VA, USA

    2 shared publications
  • Michelle R. Peace

    Department of Forensic Science, Virginia Commonwealth University , Richmond, VA 23284

    2 shared publications
  • Alaina K Friedrich

    Department of Forensic Science, Virginia Commonwealth University, Richmond, VA, USA

    1 shared publication
  • Carl E. Wolf

    Department of Forensic Science, Virginia Commonwealth University, 1015 Floyd Avenue, Room 2015, PO Box 843079, Richmond, VA 23284, USA Department of Pathology, Virginia Commonwealth University, PO Box 980165, Richmond, VA 23298-0165, USA

    1 shared publication
  • Carson Nuss

    Kansas Highway Patrol, Wichita, Kansas, USA

    1 shared publication
  • Christine Moore

    Immunalysis Corporation, Pomona, CA 91767, USA

    1 shared publication

Latest Publications

  • Driving Impairment Cases Involving Etizolam and Flubromazolam

    by Timothy P Rohrig, Kei A Osawa, Tyson R Baird, Kimberly B Youso

    This study describes 12 cases of drivers stopped for impaired driving, where a designer benzodiazepine was detected, specifically etizolam or flubromazolam. Etizolam was detected in three cases, with blood concentrations ranging from 40 to 330 ng/mL. Two of these cases had low concentrations of methamphetamine and/or amphetamine, and in the third case tetrahydrocannabinol (THC) was detected. Flubromazolam was detected in nine cases; in all cases, at least one other drug was detected, with THC being the most prevalent. The mean blood concentration of flubromazolam was 16.3 ng/mL and had a median concentration of 17.0 ng/mL, ranging from 7.0 to 31 ng/mL. The low concentrations of designer benzodiazepines that produce pharmacological effects may allow many of these drugs to go undetected using routine testing in laboratories; therefore, it is necessary to include these novel compounds within validated analytical methods to reduce the chance of reporting false negative results. The prevalence in which laboratories are detecting the presence of novel benzodiazepines in impaired drivers illustrates the increased threat to public safety. These case studies demonstrate the importance of investigating agencies and forensic laboratories to be vigilant in monitoring the emerging novel psychoactive substances in their region.


  • Open Access

    Evaluation of Nicotine and the Components of e-Liquids Generated from e-Cigarette Aerosols

    by Michelle R Peace, Haley A Mulder, Tyson R Baird, Karen E Butler, Alaina K Friedrich, Joseph W Stone, Joseph B McGee Turner, Alphonse Poklis, Justin L Poklis

    Electronic cigarettes (e-cigs) deliver nicotine in an aerosol to the user that simulates the smoke of traditional cigarettes purportedly without the pathology of inhaling tobacco smoke due to the absence of combustion. Advanced versions of e-cigs enable the user to potentially moderate the concentration of drug in the aerosol by selecting from a range of voltages on the power supply. A method was developed to trap the aerosol produced by a KangerTech AeroTank, 1.8 Ω preassembled atomizer in order to analyze the concentration of nicotine and to evaluate the constituents of the aerosol at various voltages on the power supply. A 12-mg/mL formulation of nicotine in 50:50 propylene glycol (PG):vegetable glycerin (VG) was used to produce aerosol at 3.9, 4.3 and 4.7 V. The aerosol was trapped in a simple glass assemblage and analyzed by a 3200 Q Trap HPLC–MS-MS. The dose of nicotine delivered in the aerosol at 3.9, 4.3 and 4.7 V was determined to be 88 ± 12 μg, 91 ± 15 μg and 125 ± 22 μg. The average recovery of nicotine in the trap across the voltages was 99.8%. The glass trap system was an effective device for collecting the aerosol for analysis and an increase in drug yield was observed with increasing voltage from the power supply on the e-cig. The glass trap system was also used in combination with a 100-μm solid-phase microextraction fiber to capture the aerosol and analyze it via DART–MS and GC–MS. Four commercial e-liquids labeled to contain nicotine were aerosolized at 4.3 V. The pharmacologically active ingredient, nicotine, as well as PG, VG and a number of flavoring agents found in these formulations were identified.


  • Roadside drug testing: An evaluation of the Alere DDS®2 mobile test system

    by Timothy P. Rohrig, Christine M. Moore, Kimberly Stephens, Kelsey Cooper, Cynthia Coulter, Tyson Baird, Margaux Garnier, Samuel Miller, James Tuyay, Kei Osawa, et al.

    The number of drivers using drugs has increased over the last few years, and is likely to continue its upward trend. Testing drivers for alcohol use is routine and standardized, but the same is not true for the identification of driving under the influence of drugs (DUID). The Drug Evaluation and Classification Program (DECP) was developed to train police officers to recognize the signs and symptoms of recent drug use and remains an invaluable program; however, there are insufficient numbers of these highly trained drug recognition experts (DREs) available to attend every potential drug involved traffic incident. While blood and urine samples are used to test for drugs in a driver, both have disadvantages, particularly as they pertain to the length of time required after a traffic stop to sample collection. Therefore, the development of oral fluid testing devices which can be operated at the roadside and have the potential to assist officers in the identification of drug use is a major advancement in DUID cases. This project evaluated the performance of one instrumental oral fluid roadside testing device (Alere DDS®2) compared to DRE opinion, oral fluid laboratory‐based analysis, and routine blood testing. The results showed that there was a good correlation with DRE observations and the device performance was >80% in all drug categories compared to laboratory‐based analytical testing, both in oral fluid and blood, with few exceptions. The instrument can be considered a useful tool to assist law enforcement in identifying a drugged driver. Because the device does not test for all potentially impairing drugs, the opinion of the police officer regarding the condition of the driver should still be considered the most important aspect for arrest and further action.


  • U-47700: A Not So New Opioid

    by Timothy P Rohrig, Samuel A Miller, Tyson R Baird

    U-47700 was developed by the Upjohn Co. in the 1970s as part of their search for a selective μ-opioid agonist with similar potency as morphine. U-47700 has re-emerged recently in the illicit drug market and is easily and cheaply obtained via the internet as well as on the street, many times falsely sold as another drug. Several fatalities from U-47700 have been reported in scientific literature, often in combination with other intoxicants. This case report describes the first death in south-central Kansas resulting solely from U-47700 intoxication: a 26-year-old white male found dead in his bedroom with apparent drug paraphernalia. Autopsy findings were consistent with opioid overdose, but toxicological examination, utilizing immunoassay and instrumental techniques, was negative for opioids. U-47700 was detected in a comprehensive alkaloid screen by GC/MS and GC-NPD, and quantitation was performed using GC-NPD on a variety of specimens to provide a full tissue distribution. Quantitation of U-47700 in this individual revealed the following: heart blood 0.26 mg/L, femoral blood 0.40 mg/L, vitreous fluid 0.09 mg/L, brain 0.38 mg/kg, liver 0.28 mg/kg and urine 4.6 mg/L.


  • Open Access

    Concentration of Nicotine and Glycols in 27 Electronic Cigarette Formulations

    by Michelle R. Peace, Tyson R. Baird, Nathaniel Smith, Carl E. Wolf, Justin L. Poklis, Alphonse Poklis

    Personal battery-powered vaporizers or electronic cigarettes were developed to deliver a nicotine vapor such that smokers could simulate smoking tobacco without the inherent pathology of inhaled tobacco smoke. Electronic cigarettes and their e-cigarette liquid formulations are virtually unregulated. These formulations are typically composed of propylene glycol and/or glycerin, flavoring components and an active drug, such as nicotine. Twenty-seven e-cigarette liquid formulations that contain nicotine between 6 and 22 mg/L were acquired within the USA and analyzed by various methods to determine their contents. They were screened by Direct Analysis in Real Time™ Mass Spectrometry (DART-MS). Nicotine was confirmed and quantitated by high-performance liquid chromatography–tandem mass spectrometry, and the glycol composition was confirmed and quantitated by gas chromatography–mass spectrometry. The DART-MS screening method was able to consistently identify the exact mass peaks resulting from the protonated molecular ion of nicotine, glycol and a number of flavor additives within 5 mmu. Nicotine concentrations were determined to range from 45 to 131% of the stated label concentration, with 18 of the 27 have >10% variance. Glycol composition was generally accurate to the product description, with only one exception where the propylene glycol to glycerin percentage ratio was stated as 50:50 and the determined concentration of propylene glycol to glycerin was 81:19 (% v/v). No unlabeled glycols were detected in these formulations.