SKSe-Hoon Kang

Se-Hoon Kang

*This is an algorithmically generated author record based on publicly available information.

Se-Hoon Kang has a total of 5 co-authors. Here are the top co-authors by number of shared publications:

  • Gi-Hong Ahn

    Department of Structural Engineering Research, Korea Institute of Civil Engineering and Building Technology, Goyang-si 10223, Republic of Korea

    2 shared publications
  • Gum-Sung Ryu

    Department of Structural Engineering Research, Korea Institute of Civil Engineering and Building Technology, Goyang-si 10223, Republic of Korea

    2 shared publications
  • Hyeong-Yeol Kim

    Structural Engineering Department, Korea Institute of Civil Engineering and Building Technology (KICT), Goyang-Si 10223, Korea

    2 shared publications
  • Kyung-Taek Koh

    Korean Peninsula Infrastructure Research Center, Department of Construction Policy Research, Korea Institute of Civil Engineering and Building Technology, Goyang-si 10223, Republic of Korea

    2 shared publications
  • Young-Jun You

    Structural Engineering Department, Korea Institute of Civil Engineering and Building Technology (KICT), Goyang-Si 10223, Korea

    2 shared publications

Latest Publications

  • Open Access

    Strengthening of Concrete Element with Precast Textile Reinforced Concrete Panel and Grouting Material

    by Young-Jun You, Hyeong-Yeol Kim, Gum-Sung Ryu, Kyung-Taek Koh, Gi-Hong Ahn, Se-Hoon Kang

    Textile reinforced concrete (TRC) has widely been used for strengthening work for deteriorated reinforced concrete (RC) structures. The structural strengthening often requires accelerated construction with the aid of precast or prefabricated elements. This study presents an innovative method to strengthen an RC slab-type element in flexure using a precast panel made of carbon TRC. A total of five RC slabs were fabricated to examine the flexural strengthening effect. Two of them were strengthened with the precast panel and grouting material and another set of two slabs was additionally strengthened by tensile steel reinforcement. The full-scale slab specimens were tested by a three-point bending test and the test results were compared with the theoretical solutions. The results revealed that the ultimate load of the specimens strengthened with the TRC panel increased by at least 1.5 times compared to that of the unstrengthened specimen. The application of the precast TRC panel and grouting material for the strengthening of a prototype RC structure verified its outstanding constructability.


  • Open Access

    Flexural Strengthening of Concrete Slab-Type Elements with Textile Reinforced Concrete

    by Hyeong-Yeol Kim, Young-Jun You, Gum-Sung Ryu, Kyung-Taek Koh, Gi-Hong Ahn, Se-Hoon Kang

    This paper deals with flexural strengthening of reinforced concrete (RC) slabs with a carbon textile reinforced concrete (TRC) system. The surface coating treatment was applied to a carbon grid-type textile to increase the bond strength. Short fibers were incorporated into the matrix to mitigate the formation of shrinkage-induced cracks. The tensile properties of the TRC system were evaluated by a direct tensile test with a dumbbell-type grip method. The tensile test results indicated that the effect of the surface coating treatment of the textile on the bonding behavior of the textile within the TRC system was significant. Furthermore, the incorporation of short fibers in the matrix was effective to mitigate shrinkage-induced crack formation and to improve the tensile properties of the TRC system. Six full-scale slab specimens were strengthened with the TRC system and, subsequently, failure tested. The ultimate load-carrying capacity of the strengthened slabs was compared with that of an unstrengthened slab as well as the theoretical solutions. The failure test results indicated that the stiffness and the ultimate flexural capacity of the strengthened slab were at least 112% and 165% greater, respectively, than that of the unstrengthened slab. The test results further indicated that the strengthening effect was not linearly proportional to the amount of textile reinforcement.