Rajat Kumar

Rajat Kumar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Rajat Kumar has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Computationally Efficient Swin Transformer with Enhanced Time‐Frequency Representation for Robust Classification of Complex Power Quality Disturbances

    by Sonvir Singh, Rajat Kumar, D. Bhagwan Das, Abhinav Saxena, Amevi Acakpovi

    The precise identification of power quality disturbances (PQDs) reduces economic losses by adopting the appropriate mitigation strategies. However, due to the integration of renewable energy resources, nonlinear loads and switching processes in the system, the disturbances are becoming complicated. To this end, a novel approach combining a modified digital prolate spheroidal window (DPSW)‐based Stockwell transform (S‐transform) and optimised Swin Transformer (OST) for the spontaneous identification of single‐stage and complex PQDs is proposed in this paper. This modified S‐transform is employed to evaluate the time‐frequency representation (TFR) of PQDs by optimising the parameter of DPSW to maximise the energy concentration. Subsequently, the computationally efficient OST is employed to recognise PQDs from the global and local features extracted from the TFR, where standard linear layers are replaced by convolutional stems to achieve less computational complexity. The higher value of parameters like precision, recall and F1 score, averaging above 99%, shows the exceptional ability of the proposed algorithm. The comparison with other state‐of‐the‐art techniques shows the highest 99.56% accuracy of the proposed algorithm across 16 distinct PQDs, at a 20 dB signal‐to‐noise ratio. The simulation and OPAL‐RT‐based hardware validation verify the accuracy and practical applicability of the proposed algorithm.

  • Savonius Vertical-Axis Wind Turbine: Optimal Design and Fabrication for Small-Scale Energy Applications

    by Mohan Bukya, Rajat Kumar, Abhinav Saxena, Mohammad Amir, Hasmat Malik, Shahrin Md Ayob, Mohd Rodhi Bin Sahid, Nik Din B. Muhamad

  • Design and Dynamic Framework of Solar-Based Electric Vehicle Charging Station Through Optimal Sizing Approach

    by Abhinav Saxena, Mohd. Majid, Rajat Kumar, Mohammad Amir, Hasmat Malik, Shahrin Md Ayob, Mohd Rodhi Bin Sahid, Nik Din B. Muhamad

  • Open Access

    Abnormal Health Monitoring and Assessment of a Three‐Phase Induction Motor Using a Supervised CNN‐RNN‐Based Machine Learning Algorithm

    by Abhinav Saxena, Rajat Kumar, Arun Kumar Rawat, Mohd Majid, Jay Singh, S. Devakirubakaran, Gyanendra Kumar Singh

    This paper shows the health monitoring and assessment of a three‐phase induction motor in abnormal conditions using a machine learning algorithm. The convolutional neural network (CNN) and recurrent neural network (RNN) algorithms are the prominent methods used in machine learning algorithms, and the combined method is known as the CRNN method. The abnormal conditions of a three phase‐induction motor are represented by three‐phase faults, line‐to‐ground faults, etc. The pattern of fault current is traced, and key features are extracted by the CRNN algorithm. The performance parameters like THD (%), accuracy, and reliability of abnormal conditions are measured with the CRNN algorithm. The assessment of abnormal conditions is being realized at the terminals of a three‐phase induction motor. A fuzzy logic controller (FLC) is also used to assess such abnormalities. It is observed that performance parameters are found to be better with the CRNN method in comparison to CNN, RNN, ANN, and other methods. Such a realization makes the system more compatible with abnormality recognition.


  • Open Access

    An Invasive Weed Optimization for Sensor Less Control of Grid Integrated Wind Driven Doubly Fed Induction Generator

    by Abhinav Saxena, Rajat Kumar, Jay Singh, Gyanendra Kumar Singh, V. Sampath Kumar, J. P. Pandey

    The article presents the design and development of invasive weed optimization (IWO) for the sensor less speed control of doubly fed induction generator (DFIG) under balanced and unbalanced conditions. A healthy condition represents the balanced condition while unbalancing condition is characterized by unhealthy conditions like three-phase fault, single line to ground fault, the line-to-line fault, and double line to ground fault. The DFIG is driven by wind and integrated with the grid. The advantages associated with IWO technique are a simple mathematical approach and less data computation. Normally, DFIG consists of two back-to-back converters namely grid side converter (GSC) and rotor side converter (RSC). The GSC is an uncontrolled converter while the RSC is a controlled converter. The existing methods have poor performance parameters like settling time, peak overshoot for balanced conditions, and poor power quality parameters like total harmonic distortion (THD) for unbalanced conditions. An IWO technique has been applied to overcome such limitations. The effectiveness of the sensor less speed control is also analyzed with other techniques like Adaptive Neuro-Fuzzy Interference System (AN-FIS) & artificial neural network (ANN). The design of ANN is based on the feed-forward method using back propagation delay and the design of ANFIS is based on adaptive control and state space control strategy. It is observed that performance parameters like peak overshoot and settling time for the sensor less speed of DFIG are found to be more profound with IWO in comparison to ANFIS, ANN, and other existing techniques for balanced conditions. Similarly in the unbalanced condition, faulty current approaches are quite closer to their healthy state with the IWO method in comparison to other methods. In addition to this, minimum distortion (%THD) for the grid current under unbalanced conditions is also attained with IWO in comparison to ANFIS, ANN, and other existing techniques. Such application of IWO makes the system highly efficient and robust.


  • Open Access

    A Comprehensive Overview on Modified Versions of Stockwell Transform For Power Quality Monitoring

    by Rajat Kumar, Abhinav Saxena, Raj Kumar, Sanjay Marwaha, Jay Singh, Gyanendra Kumar Singh

    The increasing trends toward the accurate identification of power quality disturbances (PQD) via power quality (PQ) monitoring require an appropriate digital signal processing (DSP) technique and a robust classifier. To this end, Stockwell transform (ST), one of the most efficient feature extraction DSP tools, and its several variants play an utmost role in PQ assessment framework. Its time-varying spectral characteristics generally extract the local instantaneous frequency spectrum from the global temporary behavior of PQD signal. However, the Standard ST suffers from thepoor time-frequency resolution because of its frequency-dependent Gaussian window (GW). While the analysis of the statistically time-varying signals requires a suitable balance between time and frequency resolution. To this end, this paper provides a comprehensive literature review on several modified versions of Standard ST for the first time to reduce the computational complexity of the algorithm as well as maximize the energy concentration of the time-frequency plane. A comparative analysis of all the modified STs has been presented in tabular form to provide the key characteristics of each technique. Additionally, a case study has been presented to substantiate the highest accuracy of the proposed algorithm over the other ST variants. Apart from the PQD classification, miscellaneous applications of Standard ST and its modified variants have been indicated. This review paper may provide a valuable resource to the researchers for further improvement of the time-frequency resolution of ST not only in classifying PQD but also for its other wide applications.


  • Online Identification of Underlying Causes for Multiple and Multi-Stage Power Quality Disturbances Using S-Transform

    by Rajat Kumar, Bhim Singh, Raj Kumar, Sanjay Marwaha

    The proposed methodology aims at the identification of multiple and multi-stage power quality (PQ) disturbances along with their underlying causes. To this end, a computationally efficient S-Transform with decision tree (DT) based online PQ monitoring algorithm has been presented in this paper. This online algorithm provides a sample-based analysis of 40-dB noisy multiple and multi-stage PQ disturbance signals simulated in MATLAB environment with the different combinations of underlying causes as per the IEEE-1159 standard. The features like residual voltage, instantaneous phase-angle jump (IPAJ), and number of zero crossings (NZC) have been extracted from the transformed contours, viz., maximum voltage amplitude versus time (MVAVT) and phase-angle versus time (PAVT). Henceforth, the accurate recognition of most common underlying causes like three-phase fault, induction motor starting, and capacitor bank energizing has been achieved. For the first time, an online PQ monitoring algorithm is effectively assessing the type and underlying cause of a multiple or multi-stage disturbance simultaneously. The proposed methodology has also been experimentally validated with real-time PQ disturbance signals acquired in the laboratory.


  • Recognition of Underlying Causes of Power Quality Disturbances Using Stockwell Transform

    by Rajat Kumar, Bhim Singh, Raj Kumar, Sanjay Marwaha

    This paper presents an effective and intelligent methodology for the recognition of several underlying causes responsible for power quality (PQ) disturbances. The disturbance signals at 40 dB signal to noise ratio (SNR) from the various locations of the power distribution system have been analyzed with computationally efficient stockwell transform (ST). Besides residual voltage and the duration, characteristic like automatic segmented phase angle jump (PAJ) has been extracted and proposed for linking the PQ disturbance with the respective underlying cause. PQ disturbances have been simulated in a MATLAB environment as per IEEE-1159 standard with the five causes namely symmetrical fault, unsymmetrical fault, induction motor starting, capacitor bank energizing and transformer energizing. A block scheme has been devised and presented here for the effective recognition of the underlying cause in a power distribution network so that the corrective measures can be proposed for the trouble-free operation of the equipment. The performance of the proposed method has also been evaluated with the real time PQ data to judge the effectiveness of the algorithm in the real environment.