Tobias Zech
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tobias Zech has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
- Johannes Will
Institute of Micro‐ and Nanostructure Research and Center for Nanoanalysis and Electron Microscopy (CENEM) IZNF Friedrich‐Alexander‐Universität Erlangen‐Nürnberg Erlangen Germany
4 shared publications Tobias Unruh
4 shared publications- Tobias Unruh
Institute for Crystallography and Structural Physics Department of Physics Friedrich‐Alexander‐Universität Erlangen‐Nürnberg Erlangen Germany
4 shared publications - Erdmann Spiecker
Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Institute of Micro- and Nanostructure Research (IMN) & Center for Nanoanalysis and Electron Microscopy (CENEM), IZNF, Cauerstr. 3, 91058 Erlangen, Germany
3 shared publications - Martin Dierner
Institute of Micro‐ and Nanostructure Research and Center for Nanoanalysis and Electron Microscopy (CENEM) IZNF Friedrich‐Alexander‐Universität Erlangen‐Nürnberg Erlangen Germany
3 shared publications - Michael Landes3 shared publications
Latest Publications
- Open Access
- 24 June 2025
- Published by Elsevier in Acta Materialia
- Vol. 297
Mismatch design of AuxNi1-x(111)/α-Al2O3(0001) interfaces and their correlative investigation by X-ray diffraction and electron microscopy
- 24 June 2025
- Published by Elsevier in Acta Materialia
- Vol. 297
Open AccessMismatch design of AuxNi1-x(111)/α-Al2O3(0001) interfaces and their correlative investigation by X-ray diffraction and electron microscopy
- Open Access
- 3 November 2024
- Published by Elsevier in Acta Materialia
- Vol. 284
Influence of substrate polarity on thermal stability, grain growth and atomic interface structure of Au thin films on ZnO surfaces
- 3 November 2024
- Published by Elsevier in Acta Materialia
- Vol. 284
Open AccessInfluence of substrate polarity on thermal stability, grain growth and atomic interface structure of Au thin films on ZnO surfaces
- Open Access
- 30 January 2024
- Published by Elsevier in Surfaces and Interfaces
- Vol. 46
Influence of Au alloying on solid state dewetting kinetics and texture evolution of Ag and Ni thin films
- 30 January 2024
- Published by Elsevier in Surfaces and Interfaces
- Vol. 46
Open AccessInfluence of Au alloying on solid state dewetting kinetics and texture evolution of Ag and Ni thin films
- Open Access
- 3 July 2022
- Published by Wiley in Advanced Science
- Vol. 9 (25) , e2202803
Radiolysis‐Driven Evolution of Gold Nanostructures – Model Verification by Scale Bridging In Situ Liquid‐Phase Transmission Electron Microscopy and X‐Ray Diffraction
Utilizing ionizing radiation for in situ studies in liquid media enables unique insights into nanostructure formation dynamics. As radiolysis interferes with observations, kinetic simulations are employed to understand and exploit beam‐liquid interactions. By introducing an intuitive tool to simulate arbitrary kinetic models for radiation chemistry, it is demonstrated that these models provide a holistic understanding of reaction mechanisms. This is shown for irradiated HAuCl4 solutions allowing for quantitative prediction and tailoring of redox processes in liquid‐phase transmission electron microscopy (LP‐TEM). Moreover, it is demonstrated that kinetic modeling of radiation chemistry is applicable to investigations utilizing X‐rays such as X‐ray diffraction (XRD). This emphasizes that beam‐sample interactions must be considered during XRD in liquid media and shows that reaction kinetics do not provide a threshold dose rate for gold nucleation relevant to LP‐TEM and XRD. Furthermore, it is unveiled that oxidative etching of gold nanoparticles depends on both, precursor concentration, and dose rate. This dependency is exploited to probe the electron beam‐induced shift in Gibbs free energy landscape by analyzing critical radii of gold nanoparticles.
- 3 July 2022
- Published by Wiley in Advanced Science
- Vol. 9 (25) , e2202803
Open AccessRadiolysis‐Driven Evolution of Gold Nanostructures – Model Verification by Scale Bridging In Situ Liquid‐Phase Transmission Electron Microscopy and X‐Ray Diffraction
Utilizing ionizing radiation for in situ studies in liquid media enables unique insights into nanostructure formation dynamics. As radiolysis interferes with observations, kinetic simulations are employed to understand and exploit beam‐liquid interactions. By introducing an intuitive tool to simulate arbitrary kinetic models for radiation chemistry, it is demonstrated that these models provide a holistic understanding of reaction mechanisms. This is shown for irradiated HAuCl4 solutions allowing for quantitative prediction and tailoring of redox processes in liquid‐phase transmission electron microscopy (LP‐TEM). Moreover, it is demonstrated that kinetic modeling of radiation chemistry is applicable to investigations utilizing X‐rays such as X‐ray diffraction (XRD). This emphasizes that beam‐sample interactions must be considered during XRD in liquid media and shows that reaction kinetics do not provide a threshold dose rate for gold nucleation relevant to LP‐TEM and XRD. Furthermore, it is unveiled that oxidative etching of gold nanoparticles depends on both, precursor concentration, and dose rate. This dependency is exploited to probe the electron beam‐induced shift in Gibbs free energy landscape by analyzing critical radii of gold nanoparticles.
- Open Access
- 7 February 2022
- Published by Wiley in Particle & Particle Systems Characterization
- Vol. 39 (3) , 2100172
Investigating Growth of Gold Nanorods by Simultaneous Small‐Angle X‐Ray and Neutron Scattering
Increased usage of gold nanorods (AuNRs) in various biosensing and medical applications requires tight size and morphology control. This is often achieved by tuning the aggregation behavior of the stabilizing ligand cetrimonium bromide (CTAB). Because the role of CTAB during AuNR growth is still a matter of debate, simultaneous small‐angle X‐ray and neutron scattering experiments (SAXS/SANS) and measurements are performed. The SAXS/SANS measurements have enabled an instantaneous correlation between the size of evolving AuNR and the nanostructure of guiding CTAB moieties. Upon modifying the aggregation behavior of CTAB micelles by adding hexanol or pentanol as inert additives in the precursor solution, a marked change in reaction kinetics is observed. Alcohol‐modified CTAB nanostructures have improved AuNR size uniformity compared to those prepared in alcohol‐free CTAB solutions, which are attributed to different growth modes. The change in reaction kinetics is linked to a changed stabilization mechanism of reactants and nascent AuNR facilitated by CTAB micelles.
- 7 February 2022
- Published by Wiley in Particle & Particle Systems Characterization
- Vol. 39 (3) , 2100172
Open AccessInvestigating Growth of Gold Nanorods by Simultaneous Small‐Angle X‐Ray and Neutron Scattering
Increased usage of gold nanorods (AuNRs) in various biosensing and medical applications requires tight size and morphology control. This is often achieved by tuning the aggregation behavior of the stabilizing ligand cetrimonium bromide (CTAB). Because the role of CTAB during AuNR growth is still a matter of debate, simultaneous small‐angle X‐ray and neutron scattering experiments (SAXS/SANS) and measurements are performed. The SAXS/SANS measurements have enabled an instantaneous correlation between the size of evolving AuNR and the nanostructure of guiding CTAB moieties. Upon modifying the aggregation behavior of CTAB micelles by adding hexanol or pentanol as inert additives in the precursor solution, a marked change in reaction kinetics is observed. Alcohol‐modified CTAB nanostructures have improved AuNR size uniformity compared to those prepared in alcohol‐free CTAB solutions, which are attributed to different growth modes. The change in reaction kinetics is linked to a changed stabilization mechanism of reactants and nascent AuNR facilitated by CTAB micelles.
- 3 February 2022
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 38 (7) , 2227-2237
Effect of Bromide on the Surfactant Stabilization Layer Density of Gold Nanorods
Some studies have speculated that the concentration of bromide ions plays a crucial role in the surfactant density surrounding gold nanorods (AuNRs). Small-angle X-ray and neutron scattering (SAXS and SANS) experiments were conducted to analyze any influence the bromide ions might have on the stabilization layer and the aggregation behavior of the ligand CTAB molecules in general. The AuNR were immersed in solutions containing a fixed CTA+ concentration of 2 mM and varying bromide ion concentrations from 0 to 22 mM. A patchy AuNR stabilization shell at low bromide ion concentrations was found, contrary to previously published SANS studies on the AuNR stabilization shell. However, with increasing bromide ion concentration, the density of the stabilization shell increases asymptotically toward a closed/collapsed bilayer configuration. AuNR grown under similar conditions show higher anisotropy with larger bromide ion concentrations. Both results indicate that anisotropic growth strongly depends on a sufficiently dense stabilization layer established by high bromide ion concentrations.
- 3 February 2022
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 38 (7) , 2227-2237
Effect of Bromide on the Surfactant Stabilization Layer Density of Gold Nanorods
Some studies have speculated that the concentration of bromide ions plays a crucial role in the surfactant density surrounding gold nanorods (AuNRs). Small-angle X-ray and neutron scattering (SAXS and SANS) experiments were conducted to analyze any influence the bromide ions might have on the stabilization layer and the aggregation behavior of the ligand CTAB molecules in general. The AuNR were immersed in solutions containing a fixed CTA+ concentration of 2 mM and varying bromide ion concentrations from 0 to 22 mM. A patchy AuNR stabilization shell at low bromide ion concentrations was found, contrary to previously published SANS studies on the AuNR stabilization shell. However, with increasing bromide ion concentration, the density of the stabilization shell increases asymptotically toward a closed/collapsed bilayer configuration. AuNR grown under similar conditions show higher anisotropy with larger bromide ion concentrations. Both results indicate that anisotropic growth strongly depends on a sufficiently dense stabilization layer established by high bromide ion concentrations.
- Open Access
- 1 November 2021
- Published by Elsevier in Acta Materialia
- Vol. 220
Rapid fabrication and interface structure of highly faceted epitaxial Ni-Au solid solution nanoparticles on sapphire
- 1 November 2021
- Published by Elsevier in Acta Materialia
- Vol. 220
Open AccessRapid fabrication and interface structure of highly faceted epitaxial Ni-Au solid solution nanoparticles on sapphire
- Open Access
- 25 June 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (13) , 5925
Simultaneous SAXS/SANS Method at D22 of ILL: Instrument Upgrade
A customized portable SAXS instrument has recently been constructed, installed, and tested at the D22 SANS instrument at ILL. Technical characteristics of this newly established plug-and-play SAXS system have recently been reported (J. Appl. Cryst. 2020, 53, 722). An optimized lead shielding arrangement on the SAXS system and a double energy threshold X-ray detector have been further implemented to substantially suppress the unavoidable high-energy gamma radiation background on the X-ray detector. The performance of the upgraded SAXS instrument has been examined systematically by determining background suppression factors (SFs) at various experimental conditions, including different neutron beam collimation lengths and X-ray sample-to-detector distances (SDDX-ray). Improved signal-to-noise ratio SAXS data enables combined SAXS and SANS measurements for all possible experimental conditions at the D22 instrument. Both SAXS and SANS data from the same sample volume can be fitted simultaneously using a common structural model, allowing unambiguous interpretation of the scattering data. Importantly, advanced in situ/real time investigations are possible, where both the SAXS and the SANS data can reveal time-resolved complementary nanoscale structural information.
- 25 June 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (13) , 5925
Open AccessSimultaneous SAXS/SANS Method at D22 of ILL: Instrument Upgrade
A customized portable SAXS instrument has recently been constructed, installed, and tested at the D22 SANS instrument at ILL. Technical characteristics of this newly established plug-and-play SAXS system have recently been reported (J. Appl. Cryst. 2020, 53, 722). An optimized lead shielding arrangement on the SAXS system and a double energy threshold X-ray detector have been further implemented to substantially suppress the unavoidable high-energy gamma radiation background on the X-ray detector. The performance of the upgraded SAXS instrument has been examined systematically by determining background suppression factors (SFs) at various experimental conditions, including different neutron beam collimation lengths and X-ray sample-to-detector distances (SDDX-ray). Improved signal-to-noise ratio SAXS data enables combined SAXS and SANS measurements for all possible experimental conditions at the D22 instrument. Both SAXS and SANS data from the same sample volume can be fitted simultaneously using a common structural model, allowing unambiguous interpretation of the scattering data. Importantly, advanced in situ/real time investigations are possible, where both the SAXS and the SANS data can reveal time-resolved complementary nanoscale structural information.
- Open Access
- 13 May 2020
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 53 (3) , 722-733
A novel experimental approach for nanostructure analysis: simultaneous small-angle X-ray and neutron scattering
Exploiting small-angle X-ray and neutron scattering (SAXS/SANS) on the same sample volume at the same time provides complementary nanoscale structural information in two different contrast situations. Unlike an independent experimental approach, the truly combined SAXS/SANS experimental approach ensures the exactness of the probed samples, particularly forin situstudies. Here, an advanced portable SAXS system that is dimensionally suitable for installation in the D22 zone of ILL is introduced. The SAXS apparatus is based on a Rigaku switchable copper/molybdenum microfocus rotating-anode X-ray generator and a DECTRIS detector with a changeable sample-to-detector distance of up to 1.6 m in a vacuum chamber. A case study is presented to demonstrate the uniqueness of the newly established method. Temporal structural rearrangements of both the organic stabilizing agent and organically capped gold colloidal particles during gold nanoparticle growth are simultaneously probed, enabling the immediate acquisition of correlated structural information. The new nano-analytical method will open the way for real-time investigations of a wide range of innovative nanomaterials and will enable comprehensivein situstudies on biological systems. The potential development of a fully automated SAXS/SANS system with a common control environment and additional sample environments, permitting a continual and efficient operation of the system by ILL users, is also introduced.
- 13 May 2020
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 53 (3) , 722-733
Open AccessA novel experimental approach for nanostructure analysis: simultaneous small-angle X-ray and neutron scattering
Exploiting small-angle X-ray and neutron scattering (SAXS/SANS) on the same sample volume at the same time provides complementary nanoscale structural information in two different contrast situations. Unlike an independent experimental approach, the truly combined SAXS/SANS experimental approach ensures the exactness of the probed samples, particularly forin situstudies. Here, an advanced portable SAXS system that is dimensionally suitable for installation in the D22 zone of ILL is introduced. The SAXS apparatus is based on a Rigaku switchable copper/molybdenum microfocus rotating-anode X-ray generator and a DECTRIS detector with a changeable sample-to-detector distance of up to 1.6 m in a vacuum chamber. A case study is presented to demonstrate the uniqueness of the newly established method. Temporal structural rearrangements of both the organic stabilizing agent and organically capped gold colloidal particles during gold nanoparticle growth are simultaneously probed, enabling the immediate acquisition of correlated structural information. The new nano-analytical method will open the way for real-time investigations of a wide range of innovative nanomaterials and will enable comprehensivein situstudies on biological systems. The potential development of a fully automated SAXS/SANS system with a common control environment and additional sample environments, permitting a continual and efficient operation of the system by ILL users, is also introduced.